Loading...
HomeMy WebLinkAboutProject InformationPro'ect Summary Job: : - wrightsoft& Entire House BY: Quick Calcs, Inc. 317 St Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com For: Alford Family LLC TBD N. 45th Street - 1431-801-0073-000-8, Fort Pierce, FL 34946 Notes: Weather: Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 22391 Btuh Ducts 4323 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 0 Btuh 0 Btuh 26715 Btuh Fort Pierce, FL, US Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17411 Btuh Ducts 5444 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 21712 Btuh Simplified Latent Cooling Equipment Load Sizing Average 0 Structure 3378 Btuh Ducts 1695 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cooling Area (ft2) 1511 1511 Volume (f?) 14203 14203 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 90 47 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.7 kW 26223 Btuh 24 OF 1000 cfm 0.037 cfm/Btu h 0.50 in H2O (none) Equipment latent load 5073 Btuh Equipment Total Load (Sen+Lat) 26785 Btuh Req. total capacity at 0.70 SHR 2.6 ton Cooling Equipment Summary Make Rheem Trade RHEEM Cond RA1630AJlNA Coil RH1T3621HTANAA AHRI ref 8080143 Efficiency 13.0 EER, 16 SEER Sensible cooling 21000 Btuh Latent cooling 9000 Btuh Total cooling 30000 Btuh Actual air flow 1000 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -oe*- wrightspft- 2020-Dec-2912:34:02 !+- » . .. .. RlghtSuite@UnivermI2019 19.0.21 RSU08101 Page l /�l,t� ...Documents\Wrightsoft HVAC1AIford Family LLC.rup Cale= MJ8 Front Door faces: W - - wrightsoft- Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Entire House Dining 2 Exposed wall 152.0 ft 22.0 ft 3 Room height 9.4 ft 9.4 ft heat(cool 4 Room dimensions 1.0 x 119.0 ft 5 Room area 1511.0 ft' 119.0 fi' Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft') Load number (Btuh/Ft"F) (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 13A4ocs 0.143 n 4.00 2.19 385 274. 1096 699 113 98 392 214 10A-m 1.670 n 46.76 25.31 48 0 2244 1215 0 0 0 0 10A-m 1.670 n 46.76 25.31 49 0 2276 1232 0 0 0. 0 1A-r1om 1,270 n 35.56 . , 26.39 15 0 _ 633 , 396 15 0, 533 396 VII 11 13A-4ocs 0.143 a 4.00 2.19 432 371 1484 811 0 0 0 0 lam; 1A-riom 1.270 a 35.56 50.79 62 9 2193 3132 0 0 0 0 13A4ocs 0.143 s 4:00 '- 2.19 179 100 402 220 0 0 0 0 1'A-r1om 1.270 s 35.56 26.39 31 62 1096 814 0 0 0 0 • D 11DO 0.390 s 1OM 10.34 47 47 517 489 0 0 0 0 y! G 13A-4ocs 0.143 w 4.00 2.19 432 417 1670 912 94 79 315 172 1A-riom 1.270 w 35.66 60.79 15 2 548 _ 783 15 1 548 783 C 1613S0ad 0.032 0.90. 1.60 1511 1511 1354 2418 119 119 107 190 F 22A tpl 0.989 - 27.69 0.00 1511 152 4209 0 119 22 609 0 61 c) AED excursion 01 1 1 1 237 Envelope loss/gain 1 19623 13020 1 1 2504 1992 12 a) Infiltration 2768 780 401 113 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 7 1610 1 230 Appliances/other 2000 0 Subtotal (lines 6 to 13) 22391 17411 2904 2335 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22391 17411 2904 2335 15 Duct loads 19% 31% 4323 5444 19% 31% 561 730 oad al roomrequi 26000I 21000I 4653130 3134 A066 ir dl (c m) I I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrighesaft�^ 2020-Dec-2912:34:02 �-, w-dd RightSuite®UnhermI201919.0.21 RSU08101 Pagel DocumentslWrightsoft HVAC1AIford Family LLC.rup Calc = MJ8 Front Door faces: W - wrightsott• Right-M Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Kitchen Bedroom 3 2 Exposedwall 13.0 ft 33.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 12.0 x 13.0 ft 12.0 x 14.0 ft 5 Room area 156.0 fF 168.0 ft' T y Construction U-va Or I HTM I Area ft' I Load I Area ft2 I Load number (Btuh/ftlue ° ' (Btuh/fN) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross I NIP/S j Heat Cool Gross N/P/S Heat Cool 6 Val 13A-4ocs 0.143 n 4.00 - 2.19 0 0 0 0 0 0 0 0 1OA-m 1.670 n 46.76 25.31 0 6 0 0 0 0 0 0 -G --G 10A-m 1.670 n 46.76 25.31 0 0 0 0 0 0 0 0 1A-r1om . 1.270 n 35.56 26.39 0 0 0, 0 0 0 0 0 Val 11 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 66 66 263 144 Imo; 1A-rtom 1.270 a 35.56 50.79 0 0 0 0 0 0 0 0 13A-4ccs 0.143 s 4.00 2.19 0 0 0 0 113 82 328 179 1 A-r1om 1270 s 35.56 26.39 - 0 0 0 0 31 31 1096 814 - .0 `D : LIDO - 0.390 s 10.92 10.34 - 0 0 0 0 0 0 0 0 Vjf L-G 13A-4ocs 0.143 w 4.00 2.19 122 122 489 267 132 132 527 288 1A-r1om 1.270 w 35.56 50.79 0 0 0 0 0 0 0 0 C 161330ad 0.032 0.90 1.60 , 156 156 140 250 . 168 168 151_ 269 F 22A-tpl 0.989 27.69 0.00 156 13 360 0 168 33 914 0 6 c) AED excursion -44 -29 Envelope loss/gain 1 989 4731 1 1 3279 1665 12 a) Infiltration 237 67 601 169 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 1226 2770 3880 1834 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1226 2770 3880 1834 15 Duct loads 19% 31% 237 866 19% 31% 749 574 rooml 145I 5 359I 4b7I 2Airreudfm) (c I I I 1 I I 3 105 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -% wrlgh.oYt' 2020-Dec-2912:34:02 RightSuiteG)Universa1201919.0.21RSU08101 Paget DocumentslWrightsoft HVAC%AIford Family LLC.rup Calc = MJB Front Door faces: W - }a- wrigntsoft- Right-M Worksheet Job: Entire House Date: Quick Calm, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Great Room Master Bedroom 2 Exposed wall 15.0 ft 29.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 1.0 x 307.0 ft 1.0 x 225.0 ft 5 Room area 307.0 fF 225.0 f? T y Construction U-value Or I HTM I Area ft' I Load I Area ft2 I Load number (Btuh/Ft�° (Btuhlft2 or perimeter (ft) (Btuh} or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V1 13A4ocs 0,143 n 4.00 2.19 141 93 372 203 132 83 332 181 10A-m 1.670 n 46.76 25.31 48 0 2244 1215 0 0 0 0 10A-m 1.670 n 46.76 25.31 0 0 0 0 49, 0 2276 1232 1Ar1om 1.270 n_ 35.56 26.39 0 0 0 _ 0 0 0 0 0 Val 11 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 141 110 441 241 I-G 1A-rlom 1.270 a 35.56 50.79 0 0 0 0 31 2 10.96 1566 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 A 0 0 0 1A-rlom 1.270 s 35.56 26.39 0 0 0 0 0 0 0 0 D 11 D0 0.390 s_ 10.92 10.34 _ 0 0 0 0. 0 0 0 0 1/y C 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 w 35.56 50.79 0 0 0 0 0 0 0 0 C 1613�30acl 0.032 _ - 0:90 . 1.60 307 307 276 491 225 225 202 360 F 22A-tpl 0.989 27.69 0.00 307 15 415 0 225 29 803 0 61 c) AED excursion -38 -65 Envelope loss/gain 3307 1872 5150 3516 12 a) Infiltration 273 77 528 149 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 3580 2409 5678 4124 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3580 2409 5678 4124 15 Duct loads 19% 31% 691 753 19% 31% 1096 1290 Total room load 4272 3162 6774 5414 Air required (cfm) 160 138 1 1 254 237 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -r�+- wrlgf't .Mft- 2020-Dec-2912:34:02 µ RightSuite®Univarsa12019 19.0.21 RSU08101 Page �...Documents\WrightsoftHVAC\Alford Family LLC.rup CaIc=MJ8 FrontDoorfaces: W - - wrightsoft* Right-M Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466.6799 Email: quickcalcs@aol.com 1 Room name WIC 1 WIC 2 2 Exposedwall 5.0 ft 0 ft 3 Room height 9.4 ft heat/cool 9.4 it heat/cool 4 Room dimensions 6.0 x 5.0 ft 5.0 x 5.0 ft 5 Room area 30.0 ft, 25.0 ft' Ty Construction U-value Or HTM I Area (ft') Load Area (ft') Load number (Btuhlftz-F) (Btuh/Ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 10A-m. 1.670 n 46.76 25.31 0 0 0 0 0 0 0 0 10A-m 1.670 n 46.76 25.31 0 0 0 0 0 0 0 0 1A-r1om 1.270 n_ 35.56 26.39 0 0 0 0 0 0_ 0 0 Vjl I-C 11 13A-flocs 0.143 a 4.00 2.19 47 47 188 103 0 0 0 0 1A-riom 1.270 a 35.56 50.79 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 s 35.% 26.39 0 0 0 0 0 0 0 0 D 1.1 D0 0.390 's; 10.92 10.34 0 0 0 0 0 0 0. 0 yl L-G 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-riom 1.270 w 35.56 50.79 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 _ - 0.90 1.60 30 30 27 48 _ 25 25 22 40 F 22A-tpl 0.989 - 27.69 0.00 30 5 138 0 25 0 0 0 61 c) AED excursion -31 1 1 11 Envelope loss/gain 1 354 148 1 1 22 39 12 a) Infiltration 91 26 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 445 174 22 39 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 445 174 22 39 15 Duct loads 19% 31% 86 54 19% 31% 4 12 room 520301 210I 21 52 equi dal Air required(c m) I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �: "�' wrlghsott* 2020-Dec-2912:34:02 -mow RightSuite®Universal 2019 19.0.21 RSU08101 Page Documents\Wrightsoft l VAMAlford Family LLC.rup Calc = MJB Front Door faces: W �- wrightsoft• Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466.6799 Email: quickcalcs@aol.com 1 Room name M Bath Bedroom 2 2 Exposed wall 7.0 ft 12.0 ft 3 Room height 9.4 ft heat/cool 9.4 It heat/cool 4 Room dimensions 13.0 x 7.0 ft 1.0 x 177.0 ft 5 Room area 91.0 fP 177.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') I Load number (Btuh tft'°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6-G 13A-rn n 2.19 0 0 0 0 0 0, 0 0 10A-m 1.670 1.670 n 6.76 46.76 25.31 0 0 0 0 0 0 0 0 10A-m 1.670 n 46.76 25.31. 0 0 0 0 0 0 0 0 1 A-r1 om . 1.270 n 35:56 26.39 0 D 0 0 0 0 0 0 VIL am, 11 13A-4ocs 0.143 a 4.00 2.19 66 50 202 110 113 97 390 213 1A-r1om 1.270 a 35.56 50.79 15 1 548 783 15 1 548 783 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 s 35i56 26.39 0 0 0 0 0 0 0 0 D .11DQ 0.390 s 10.92 10.34 0 0 ._ 0 0 0 0 0 0, t-G 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 w 35.56 50.79 0 0 0 0 0 0 0 0 C 16B30ad 0.032 - 0.90 1.66 91, _ 91 82 146 _ 177 177, 159 283 F 22A-tpl 0.989 - 27.69 0.00 91 7 194 0 177 12 332 0 (3 c) AEC) excursion 1 1 -17 -24 Envelope loss/gain 1 1025 1022 1 1 1429 1255 12 a) Infiltration 127 36 219 62 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 1153 1058 1648 1547 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 3 5 7 12 14 Subtotal 1155 1063 1654 1558 15 Duct loads 19% 31% 223 332 19% 31% 319 487 room 1352I 136 1974I 20 Air required (c m) I I I 1 I I 90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. " wriI Ttttso!"" 2020-Dec-2912:34:02 RightSuiteeUniverm12019 19.0.21 RSU08101 Pages ...DocumentslWrightsoft HVAC\Alford Family LLC.rup Cale = MJ8 Front Door faces: W - ' wrightsofrt- Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Laundry Foyer 2 Exposed wall 9.0 ft 7.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 7.0 x 9.0 ft 5 Room area 63.0 ft' 63.0 ft2 T y Construction U-value Or HTM I I Area ft2 I Load Area ft2 Load number (Btuhfft2'F) (Btuh/Ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S j Heat Cool j Gross N/P/S Heat Cool 6 13A-0ocs 0,143 n; 4A0 2.19 0 0 D 0 0 0 0 0 10A m 1.670 n 46,76 25.31 0 0 0 0 0 0 0 0 T 10A-m 1.670., n 46.76, 25.31 0 0 0 0 0' 0 0 0 jArtom .,` 1270 n,_, 35.5e 26.39 0- 0 0 0 0 0 11 V)I 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 I—(3 1A-rlom 1.270 a 35.56 50.79 0 0 0 0 0 0 0 0 - 13A flocs . " 0.143 s 4.00, 2.19 0 0 0 0 66 ' 18 74 40 �fDV 1'A-rlom 1.270 s 35.56, 26.39 0 0 0 0 0 0 0 0 1,1 D0 0:390 ' ° 10,92: ,"' 10:34 , 0 :. - _ 0 0 _. 0 47 .. _. 47 51T 489 11� 13A-4ocs 0.143 w 4.00 2.19 85 85 339 185 0 0 0 0 ___o 1 A-rl om 1.270 w 35.56 50.79 0 0 0 0 0 0 0 0 166�Oad',, O.D32 0.90' , _ f;60 63 _ 63 56 101; 63 - 63 ; . 56; 101 F 22A-tpl 0.989 - 27.69 0.00 _ 63 9 249 0 63 7 194 0 61 c) AED excursion 1 -5 -10 Envelope loss/gain 644 281 841 620 12 a) Infiltration 164 46 127 36 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 808 327 969 656 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 9 17 7 12 14 Subtotal 818 344 975 668 15 Duct loads 19% 31% 158 107 19% 31% 188 209 al room load 976 51 420I 1164 77 838I Air required (c m) I I 37I I I 44I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Flawrig��trzta�t^ 2020-Dec-2912:34:02 • -^n RightSuite®Universal 2019 19,0,21 RSUD8101 Page DocumentslWrightsoft HVAC\Alford Family LLC.mp Cale = W8 Front Doorfaces: W - wrightsoft• Right-M Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bath 2 Hall 2 Exposedwall O ft O ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/cool 4 Room dimensions 9.0 x 5.0 ft 1.0 x 42.0 ft 5 Room area 45.0 ft' 42.0 ft' Ty Construction U-value Or I HTM I Area (ft') I Load Area (ft') I Load number (Btuhfft ` (Btuhfftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross MP/S Heat Cool Gross N/P/S Heat Cool 6 1 8A,4ocs 0:143 n 4.00 2.19 0 0 0 0 0 0 0 0 �G 10A-m 10A-m 1.670 1;670 h n 46.76 46.76 25.31 25.31 0 0 0 0 0 0 0' 0 0 0 6 0 0 0 0' 0 ---G 1A-r1om 1:270 n 35:56 26.39 0 0 0 0 0 0 0 0 V�/ 11 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 t-C 1 A-r1 om. 1.270 a 35.56 50.79 0_ 0 0 0 0 0 0 0 V)I 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 1A-rtom 1.270 s 35.56. 26.39 0 0 0 0 0 0 0 0 14--G D 11 Do 0.390 _ Sr 10.92 .. 10.34 0 '.. 0 0_ 0 0 0 0 0 13A4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlom 1.270 w 35.56 50.79 0 0 0 0 0 _ 0 0 0 C 1.68-30ad 0.032 0.90 1.60 _ 45 45 40 72 42 42 38 67 F 22A-tpl 0.989 -, 27.69 0.00 45 0 0 0 42 0 0 0 Ll 61 c) AED excursion 1 -1 Envelope loss/gain 40 71 1 1 38 66 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 40 71 38 66 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 12 21 -38 -66 14 Subtotal 52 92 0 0 15 Duct loads 19% 31% 10 29 19% 31% 0 0 room 62I 12I 5 I (c m) I I I I IAirreui 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. "�' wr lghrx�af!- 2020-Dec-29 12:34:02 .�t i m•, �; -� RightSuite9univermI201919.0.21 RSU08101 Pagel DocumentslWrightsoft HVACIAlford Family LLC.rup Calc = MJ8 Front Doorfaces: W -- wrightsofty Duct System Summary J Entire House By: Quick Calm, Inc. 317 St Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Emait quickcalcs@aol.com For. Alford Family LLC TBD N. 45th Street - 1431-801-0073-000-8, Fort Pierce, FL 34946 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.312 in/100ft 1000 cfm 160 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.312 in/100ft 1000 cfm Name Design (Btu h) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath c 121 2 5 0.387 4.0 Ox0 VIFX 14.3 115.0 st3 Bedroom 2 c 2046 74 90 0.393 6.0 Ox 0 VIFX 12.4 115.0 st3 Bedroom 3 h 4630 173 105 0.365 8.0 OX 0 VIFX 21.9 115.0 st1 Dining c 3065 130 134 0.348 7.0 Ox 0 VIFX 28.7 115.0 st4 Foyer h 1164 44 38 0.381 6.0 Ox0 VIFx 16.2 115.0 st1 Great Room h 2136 80 69 0.375 6.0 Ox 0 VIFX 18.4 115.0 st1 Great Room -A h 2136 80 69 0.354 6.0 Ox 0 VIFx 26.1 115.0 st1 Kitchen c 3636 55 159 0.352 8.0 OX0 VIFX 27.2 115.0 st4 Laundry h 976 37 20 0.400 4.0 Ox 0 VIFX 10.1 115.0 st3 M Bath c 1395 52 61 0.371 6.0 Ox 0 VIFx 19.9 115.0 st2 Master Bedroom h 3387 127 118 0.312 7.0 Ox 0 VIFX 25.2 135.0 st5 Master Bedroom -A h 3387 127 118 0.312 7.0 Ox 0 VIFx 25.2 135.0 st5 wic 1 h 530 20 10 0.370 4.0 OX 0 VIFx 20.3 115.0 . st2 WIC 2 c 52 1 2 0.372 4.0 Ox 0 VIFx 19.3 115.0 st2 Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st4 Peak AVF 184 293 0.348 538 10.0 0 x 0 VinlFlx st1 Peak AVF 377 282 0.354 480 12.0 0 x 0 VinlFlx st5 Peak AVF 254 237 0.312 574 9.0 0 x 0 VinlFlx st2 st2 Peak AVF 326 310 0.312 598 10.0 0 x 0 VinlFlx st3 Peak AVF 113 115 0.387 429 7.0 0 x 0 VinlFlx �� wrightsoft- RightSuite@Universa12019 19.0.21 RSU08101 Z+ & ...DocumentslWrightsoft HVAC1Alford Family LLC.rup Calc = MJS Front Doorfaces: W 2020-Dec-29 12:34:03 Page 1 Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1000 1000 0 0 0 0 Ox 0 VIFx wrightsoft- 2020-Dec-2912:34:03 RightSuiteGUniversa12019 19.0.21 RSU08101 Page iit +Documents\Wrightsoft HVAC%Aiford Family LLC.rup Cale = MJ8 Front Door faces: W