HomeMy WebLinkAboutEnergy Efficiency Code 2-2-22FILE COPY
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
T Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 144A RH - FPt40030
Builder Name: FOCUS HOMES
Street: 7704 SEBASTIAN ROAD
Permit Office:
City, State, Zip: Fort Pierce, FL, 34951
Permit Number.
Owner: FOCUS HOMES
Jurisdiction:
'Design Location: FL, ST LUCIE CO INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type$1642.7 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1325.30 ft'
b. Frame - Wood, Adjacent
R=13.0 317.33 ft'
3. Number of units, if multiple family 1
c, N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
11. Ceiling Types (1443.0 sgft.)
Insulation Area
5. [s this a worst case? No
a. Under Attic (Vented)
R=30.0 1443.00 ft
6_ Conditioned floor area above grade (ft') 1443
b. N/A
R= fI2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
7. Windows(130.0 sgft.) Description Area
12. Ducts
a. Sup: Attic, ReL Main, AH: Main
R ft2
6 300
a. U-Factor. Dbl, U434 90.00 ft2
SHGC: SHGC=0.23
b. U-Factor. Dbl, U=0.55 40.00 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
22.8 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
14. Heating systems
kBtulhr Efficiency
Area Weighted Average SHGC: 0.236
a. Electric Heat Pump
22.8 HSPF:9.00
8. Skylights Area
c. U-Factor.(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 50 gallons
9. Floor Types (1443.0 sgft.) Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation R=0.0 1443.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. NIA R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 43.68
PASS
Total Baseline Loads: 47.42
�.I hereby certify that the plans and specifications covered by
Review of the plans and
;'-this calculation are in compliance the Florida Energy
specifications covered by this
.y = 0�,
ode. �'
calculation indicates compliance
,I
with the Florida Energy Code.
PREPARED BY:
DATE:
Before construction is completed
this building will b
compliance 'th Sec io 1.1 D F
I hereby certify that this building, as designed, i 'a compliance
Florida Stat DE COMPLI
'�
with the Florida Energy Code_
STD LUCIE COUNTY ® D
OWNER/AGENT. -
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
1/18/2022 1:02 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 .
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
144A RH - FP140030
User
FOCUS HOMES
1
FOCUS HOMES
Detached
New (From Plans)
Bedrooms: 3
Conditioned Area: 1443
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
1
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 7704 SEBASTIAN ROA
County: St. Lucie
City, State, Zip: -Fort Pierce ,
FL, 34951
CLIMATE
r
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days .Moisture Range
FL, ST LUCIE CO_INTL FL VERO BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1443 12987
SPACES
Number
Name
Area Volume Kdchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1443 12987 Yes 4
3
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 179 ft 0
1443 ft2
0.3 0 0.7
ROOF
/
#
Type
Roof Gable Roof
Materials Area Area Color
Rad
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip Composition shingles 1614ft2 0 ft2 Medium
N
0.85 No 0.9 'No 0 26.6
ATTIC
V) #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1443 ft2
N N
- CEILING
• i�
#
Ceiiing Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1443 ft2 0.07 Wood
1/18120221:02 PM 7.0.00 - FlaRes2026 FBC 7th Edition (2020) Compliant Software Page 2 of 4
�J
r:nphn RdnK_9n9n IhIP1IT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height Sheathing Framing Solar
Below
"
mt
To Wall type Space
RA alue-Et-ln Ft in Area R_ualuP
Frantinn Ahcnr
fora o
i 1
N
Exterior Concrete Block - Int Insul Main
4.1 20 9 4 186.7 ft2
0 0.6
0
2
E
Exterior Concrete Block- Int Insul Main
4.1 48 9 4 448.0 ft2
0 0.6
0
3
S
Exterior Concrete Block- Int Insul Main
4.1 40 9 4 -373.3 112
0 0.6
0
4
W
Exterior Concrete Block - Int Insul Main
4.1 34 9 4 317.3 ft2
0 0.6
0
5
S
Garage Frame - Wood Main
13 34 9 4 317.3 ft2
0.19 0.01
0
DOORS
#
Omt Door Type Space
Storms U-Value Width
Height
Area
Ft In
Ft In
1
S Insulated Main
None .16 3
8
24 ft2
2
N Insulated Main
None .16 2 6
6 8 16.7 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1
S 3 Vinyl Low-E Double Yes
-0.34 0.23 N 20.0 ft2 1 it 0 in 2 ft 0 in
Drapes/blinds
None
2
N 1 Vinyl Low-E Double Yes
0.34' 0.23 N 30.0 ft2 1 ft 0 in 2 ft 0 in
Drapes/blinds
None
3
E 2 Vinyl Low-E Double Yes
0.34 0.23 N 20.0 ft2 1 ft 0 in 2 It 0 in
Drapes/blinds
None
4
W 4 Vinyl Low-E Double Yes
0.34 0.23 N 20.0 ft2 1 R 0 in 2 It 0 in
Drapes/blinds
None
5
N 1 Metal Low-E Double Yes
0.55 0.26 N 40.0 ft2 1 ft 0 in 1 ft 0 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
413 ft2 413 ft2
40 It 9 ft
1
INFILTRATION
#
Scope
Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .0004
1515.2 83.13 156.06 .1324
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/ None
Singl HSPF•:9 22.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/ None
Sing] SEER: 16 22.8 kBtuthr 684 cfm
0.73 1
sys#1
1/1812022 1:02 PM 7.0.00 - F1aRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKU IST RFpnRT
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use
SetPnt
Conservation
1
Electric None
Garage 0.95 50 gal 60 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume FEF
None
None
ft2
DUCTS
/
--- Supply—
— Return ---- Air
CFM 25
CFM25
HVAC #
Location R Value Area
Location Area Leakage Type Handler
TOT
OUT
ON RLF Heat Cool
1
Attic 6 300 ft2
Main 20 ft= Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling [[X Jan
[X� Jan
[X Jan
X Feb [X] Mar
f ?C Feb [X] Mar
[ Feb R1 Mar
j Apr May ] Jun JuI (X Aug
�X] AFr f X� Ma�X] Jun f X Jul [XI Aug
A
.Se
�X� Se�
?[ C�
Oct Nov
Oct Ix
X�Nov1X]Venting
X]Heating
[X] r [X Ma [X] Jun [X Jul [X Au
[X Se
[X
Oct X Nov
X] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3 4 5 6 7
a
9
10 11
12
Cooling (WD)
AM 78
PM 80
78 78 78 78 78 78
80 78 78
78
80
80 80
80
78 78 78
78
78
78 78
78
Cooling (WEH)
AM 78
PM 78
78 78* 78 78 78 78
78 78
78
78
78 78
78
78 78 78 78
78
78
78 78
78
Heating (WD)
AM 66
PM 68
66 66 66 fib 68 68
68 68 68
68
68
68 68
68
68 68 68
68
68
68 66
66
Heating (WEH)
AM 66
PM 68
66 66 66 66 68 68
68 68 68
68
68
68 68
68
68 68 68
68
68
68 66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run Time
Cooling System
None
0
0 0 0 1 - Electric Heat Pump
0%
1 - Central Unit
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 R2 Oft 0.3
Main
111812022 1:02 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the EnergyPerformance Index, the more efficient the home.
7704 SEBASTIAN ROAD, Fort Pierce, FL, 34951
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz}
7. Windows * Description
a. U-Factor. Dbl, U=0.34
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.25
c. U-Factor: N/A
SHGC:
d. U-Factor. NIA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-FactogAVG): NIA
SHGC(AVG): NIA
New (From Plans)
1.0. Wall Type and Insulation
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. NIA
3
d. N/A
11. Ceiling Type and insulation level
No
a. Under Attic (Vented)
1443
b. NIA
Area
c. N/A
90.00 ft2
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Main, AH: Main
40.00 ft2
13. Cooling systems
ftz
a. Central Unit
ft2
1.000 ft.
0.236
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1443.00 ftz
b. N/A R= ft2
c. NIA R= ft2
14. Heating systems
a. Electric Heat Pump
16. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
76 this home before final inspection. Otherwise, anew EPL Display Card will be completed
based on installed Code compliant features.y ..
Builder Signature: Date:��
Address of New Home: City/FL Zip:
Insulation Area
R=4.1 1325.30 ftz
R=13.0 317.33 ftz
R=
ftz
R=
ft2
Insulation
Area
R=30.0
1443.00 ft2
R=
ftz
R=
ftz .
R ft2
6 300
kBtu/hr
Efficiency
22.8
SEER:16.00
kBtu/hr Efficiency
22.8 HSPF:9.00
Cap: 50 gallons
EF: 0.95
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT_
1/18/2022 1:02 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a
Project Name: 144A RH - FP140030 Builder Name: FOCUS HOMES
Street: 7704 SEBASTIAN ROAD • Permit Office:
City, State, Zlp: Fort Pierce , FL, 34951 Permit Number:
Y
Owner. FOCUS HOMES Jurisdiction:
w
Design Location: FL, ST_LUCIE_Co INTL
_
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed In the building envelope.
Air -permeable Insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be seated.
Ceilinglattic
The air barrier in any dropped ceifinglsoffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps In the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be Insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim Joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity Insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace wall
.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed fight fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface_
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind i2loina and wirina.
Showerltub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electricallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
seated in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
�etween fire sprinkler cover plates and walls or ceilings -
a. in addition, inspection or log wails snail be in accordance with the provisions of ICG1100.
1/18/2022 1:03 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 71h Edition (2026) Compliant Software Page 1 of 1