HomeMy WebLinkAboutMeadowood Lot 2-dsUES Project No: Workorder No: Report Date: 3310.1500002.0000 263857-1 03/14/2022 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:GHO HOMES CORPORATION UES Technician:Anthony Acevedo 590 NW Mercantile Place Port St. Lucie, FL 34986 Date Tested:03/14/2022 Project:MEADOWOOD SUBDIVISION (FDC) Meadowood Dr. Various Lots, Fort Pierce, Indian River County, FL 34951 Type of Test: Area Tested:Lot 2 - 9629 Knollwood Lane, Ft. Pierce Field:ASTM D-6938 Nuclear Gauge Method Material:Fill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Fill The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 NW CORNER FOOTING 0-1 ft 117.8 11.1 115.9 10.3 98 Pass 2 SE CORNER FOOTING 0-1 ft 117.8 11.1 116.2 9.4 99 Pass 3 CENTER OF PAD 0-1 ft 117.8 11.1 116.8 9.6 99 Pass Remarks:Permit: 211-00693 Reviewed By GFA International, Inc FBPE Registry No.4930 Alex Albandoz, P.E. STATE OF FLORIDA Professional Engineer No. 92555 This item has been digitally signed and sealed by Alex Albandoz, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1