HomeMy WebLinkAboutEnergy Efficiency CodeFILE COpy FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performa , e Method Project Name: 186A LH - FP010153 Builder Name: FOCUS HOMES Street: 5602 SHANNON DRIVE Permit Office: City, State, Zip: Fort Pierce , FL, 34950 Permit Number. Owner: FOCUS HOMES Jurisdiction: Design Location: FL, ST_LUCIE_CO_INTL County:. St. Lucie (Florida Clunate Zone 2 ) f 1. New construction or existing New (From Plans) 10. Wall Type41646.7 sqft.)/7 Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul/Exterior R=4.1 1473.30 ft2 b. Frame - Wood, Adj cei`( R=13.0 173.33 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? es Wo 11. Ceiling Types ( -8�6.0 sgft.) a. Under Attic (Vented) Insulation Area 2 R=30.0 1876.00 ft 6. - Conditioned floor area above grade (ft2) 1876 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 C. NIA R= ft2 7. Windows(140.0 sgft.) Description Area 12. Ducts ttic, Ret: Main, AH: Main R ft2 6 320 a. U-Factor. Dbl, U=0.34 100.00 ft2 SHGC: SHGC=0.23 b. U-Factor. Dbl, U=0.5540. 0 ft2 SHGC: SHGC=0.25 ng systems /�,'a/.CentralUnit kBtu/hr Efficiency 29.2 SEER:16.00 c. U-Factor. NIA 1' 2 SHGC:Area Weighted Average Overhang Depth: t.000'ft.14. Area Weighted Average SHGC: 0 Heating systems a. Electric Heat Pump kBtu/hr Efficiency 29.2 HSPF:9.00 8. Skylights `Area c. U-Factor(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (18,76.0 sgft.) Insulation Area . R EF:0.950 a. Slab -On -Grade Edge Insulation 0 01 1876.00, 2 b. Conservation features b. N/A ft2 ` None c. N/A ' R'--- ft2 16. Credits Pstat Glass/Floor Area: 0.075 Total oposed Modified Loads: 52.56 Total Baseline Loads: 57.16 PASS 1 hereby certify that the plans and speci if -cations covered by Review of the plans and D��IiE STA�� this calculation are in compliance wit F 'e Florida Energy Code. / specifications covered by this calculation indicates compliance ti � y�,,, ''% `` ' ��,�� yis I Energy Code. !r '`% with the Florida rrrrrr. •: N PREPARED Y: DATE: ri✓ Before construction is completed this building will be inspected for compliance with Section 553.908 * ° I hereby certify that this building, as designed, is in compliance °. Florida Statutes. COD with the Florida Ener r� yyET�� OWNER/AGENT: --T BUILDING OFFICIAL: DATE: DATE: - Compliance reqes certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance quires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope le,page test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Complia%ce with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested iAlcordance with ANSI/RESNET/ICC 380, is not greater than 0.070 Qn for whole house. 7/14/2021 7:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FnRM Ranr_gron INPUT Sl1MMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: 186A LH - FP010153 User FOCUS HOMES 1 I FOCUS HOMES Detached New (From Plans) Bedrooms: 4 Conditioned Area: 1876 Total Stories: 1 Worst Case: Yes Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 5602 SHANNON DRIV County: St. Lucie City, State, Zip: Fort Pierce , FL, 34950 CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1676 16884 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1876 16884 Yes 4 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 164 ft 0 1876 ft2 -_-_ 0 0.3 0.7 ROOF # Type Roof Gable Roof Materials Area Area Color Rad Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) • 1 Hip Composition shingles 2098 ft2 0 ft2 Medium N 0.85 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1.876 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1876 ft2 0.07 Wood 7/14/2021 7:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below t To wall Type R-\/atue_ Ft In Ft in Ara;; R-Vawa Fraction Ahso 1 N Exterior Concrete Block - Int Insul Main 4.1 20 0 8 8 173.3 ft2 0 0.6 0 2 E Exterior Concrete Block - Int Insul Main 4.1 65 0 8 8 563.3 ft2 0 0.6 0 3 S Exterior Concrete Block - Int Insul Main 4.1 39 8 8 338.0 ft2 0 0.6 0 4 W Exterior Concrete Block - Int Insul Main 4.1 46 8 8 398.7 ft2 0 0.6 0 _ 5 N Garage Frame - Wood Main 13 20 8 8 173.3 ft2 0.19 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .16 3 8 24 ft2 2 N Insulated Main None .16 2 6 6, 8 16.7 ft2 WINDOWS Orientation shown is the entered orientation (=>) changed to. Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.34 0.23 N 30.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 2 W 4 Vinyl Low-E Double Yes 0.34 0.23 N 15.0 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None 3 E 2 Vinyl Low-E Double Yes 0.34 0.23 N 20.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None 4 S 3 Metal Low-E Double Yes 0.55 0.25 N 40.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 S 3 Vinyl Low-E Double Yes 0.34 0.23 N 15.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None 6 W 4 Vinyl Low-E Double Yes 0.34 0.23 N 20.0 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 408 ft2 408 ft2 45 ft 9 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1969.8 108.07 202.89 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singl HSPF:9 29.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Singl SEER: 16 29.2 kBtu/hr 876 cfm 0.73 1 sys#1 7/14/2021 7:32'AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 47 gal 120 deg None SOLAR HOT WATER.SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS J ---- Supply --- -- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic. 6 320 ftz Main 20 ft' Proposed Qn Main — elm 131.3 cfm 0.07 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[[X Jan X.] Feb Mar X A r X]] Ma [[XX]] Jun [[X Jul [Xj Au X]] Se X] Oct X Nov Dec X Heatin[X� Jan XI Feb rX Mar X Apr May X] Jun X� Jul X] Aug Sep IX] Oct Nov Dec Venting [X Jan X]] Feb Mar lX] X Apr [X]) May XXll Jun X Jul Xl Aug lX] [[X]] Sep [X, Oct [X Nov lX� [X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 0 1 - Electric Heat Pump 0% 1 - Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 Main 7/14/2021 7:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX` = 92 The lower the EnergyPerformance Index, the more efficient the home. 5602 SHANNON DRIVE, Fort Pierce, FL, 34950 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1473.30 ft2 b. Frame - Wood, Adjacent R=13.0 173.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1876.00 ft 6. Conditioned floor area (ft2) 1876 b. N/A R= _ ft2 c. N/A R= ft2 7. Windows** Description Area 12. Ducts, location & insulation level R ft a. U-Factor. Dbl, U=0.34 100.00 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 320 SHGC: SHGC=0.23 b. U-Factor. Dbl, U=0.55 40.00 ft2 SHGC: SHGC=0.25 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 29.2 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems - kBtu/hr Efficiency SHGC: a. Electric Heat Pump 29.2 HSPF:9.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.236 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A 2 ft2 a. Electric EF:0.95 SHGC(AVG): NIA b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1876.00 ft2 Credits (Performance method) Pstat b. NIA R= ft2 c. NIA R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code com t featur s / \ Builder Signature: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/14/2021 7:32 AM EnergyGauge RO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 186A LH - FP010153 Builder Name: FOCUS HOMES Street: 5602 SHANNON DRIVE Permit Office: City, State, Zip: Fort Pierce , FL, 34950 Permit Number: Y U Owner: FOCUS HOMES Jurisdiction: w x Design Location: FL, ST_LUCIE_CO_INTL v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as, Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be.sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire surinkler cover plates and walls or ceiloncis. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 7/14/2021 7:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1