HomeMy WebLinkAboutEnergy Efficiency CodeFILE COpy
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performa , e Method
Project Name: 186A LH - FP010153
Builder Name: FOCUS HOMES
Street: 5602 SHANNON DRIVE
Permit Office:
City, State, Zip: Fort Pierce , FL, 34950
Permit Number.
Owner: FOCUS HOMES
Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
County:. St. Lucie (Florida Clunate
Zone 2 )
f
1. New construction or existing New (From Plans)
10. Wall Type41646.7 sqft.)/7
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul/Exterior
R=4.1 1473.30 ft2
b. Frame - Wood, Adj cei`(
R=13.0 173.33 ft2
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? es
Wo
11. Ceiling Types ( -8�6.0 sgft.)
a. Under Attic (Vented)
Insulation Area 2
R=30.0 1876.00 ft
6. - Conditioned floor area above grade (ft2) 1876
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
C. NIA
R= ft2
7. Windows(140.0 sgft.) Description Area
12. Ducts
ttic, Ret: Main, AH: Main
R ft2
6 320
a. U-Factor. Dbl, U=0.34 100.00 ft2
SHGC: SHGC=0.23
b. U-Factor. Dbl, U=0.5540. 0 ft2
SHGC: SHGC=0.25
ng systems
/�,'a/.CentralUnit
kBtu/hr Efficiency
29.2 SEER:16.00
c. U-Factor. NIA 1' 2
SHGC:Area Weighted Average Overhang Depth: t.000'ft.14.
Area Weighted Average SHGC: 0
Heating systems
a. Electric Heat Pump
kBtu/hr Efficiency
29.2 HSPF:9.00
8. Skylights `Area
c. U-Factor(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (18,76.0 sgft.) Insulation Area .
R
EF:0.950
a. Slab -On -Grade Edge Insulation 0 01 1876.00, 2
b. Conservation features
b. N/A ft2
`
None
c. N/A ' R'--- ft2
16. Credits
Pstat
Glass/Floor Area: 0.075 Total oposed Modified Loads: 52.56
Total Baseline Loads: 57.16
PASS
1 hereby certify that the plans and speci if -cations covered by
Review of the plans and
D��IiE STA��
this calculation are in compliance wit F 'e Florida Energy
Code. /
specifications covered by this
calculation indicates compliance
ti �
y�,,, ''% `` ' ��,�� yis
I
Energy Code.
!r '`%
with the Florida
rrrrrr. •: N
PREPARED Y:
DATE: ri✓
Before construction is completed
this building will be inspected for
compliance with Section 553.908
* °
I hereby certify that this building, as designed, is in compliance
°.
Florida Statutes.
COD
with the Florida Ener
r�
yyET��
OWNER/AGENT: --T
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance reqes certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance quires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope le,page test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Complia%ce with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested iAlcordance with ANSI/RESNET/ICC 380, is not greater than 0.070 Qn for whole house.
7/14/2021 7:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FnRM Ranr_gron INPUT Sl1MMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
186A LH - FP010153
User
FOCUS HOMES
1 I
FOCUS HOMES
Detached
New (From Plans)
Bedrooms: 4
Conditioned Area: 1876
Total Stories: 1
Worst Case: Yes
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 5602 SHANNON DRIV
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34950
CLIMATE
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1676 16884
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1876 16884 Yes 4
4
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 164 ft 0
1876 ft2
-_-_ 0 0.3 0.7
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Rad
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
• 1
Hip Composition shingles 2098 ft2 0 ft2 Medium
N
0.85 No 0.9 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1.876 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1876 ft2 0.07 Wood
7/14/2021 7:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
t
To wall Type R-\/atue_ Ft In Ft in Ara;; R-Vawa Fraction Ahso
1 N
Exterior Concrete Block - Int Insul Main
4.1 20 0 8
8 173.3 ft2
0 0.6
0
2 E
Exterior Concrete Block - Int Insul Main
4.1 65 0 8
8 563.3 ft2
0 0.6
0
3 S
Exterior Concrete Block - Int Insul Main
4.1 39 8
8 338.0 ft2
0 0.6
0
4 W
Exterior Concrete Block - Int Insul Main
4.1 46 8
8 398.7 ft2
0 0.6
0
_ 5 N
Garage Frame - Wood Main
13 20 8
8 173.3 ft2
0.19 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width Height
Area
Ft
In Ft In
1
N Insulated Main
None
.16 3
8
24 ft2
2
N Insulated Main
None
.16 2
6 6, 8
16.7 ft2
WINDOWS
Orientation shown is the entered orientation (=>) changed to. Worst Case.
Wall
Overhang
V #
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation Int Shade
Screening
1
N 1 Vinyl Low-E Double Yes
0.34 0.23 N
30.0 ft2 1 ft 0 in
1 ft 0 in Drapes/blinds
None
2
W 4 Vinyl Low-E Double Yes
0.34 0.23 N
15.0 ft' 1 ft 0 in
1 ft 0 in Drapes/blinds
None
3
E 2 Vinyl Low-E Double Yes
0.34 0.23 N
20.0 ft2 1 ft 0 in
2 ft 0 in Drapes/blinds
None
4
S 3 Metal Low-E Double Yes
0.55 0.25 N
40.0 ft2 1 ft 0 in
1 ft 0 in Drapes/blinds
None
5
S 3 Vinyl Low-E Double Yes
0.34 0.23 N
15.0 ft2 1 ft 0 in
2 ft 0 in Drapes/blinds
None
6
W 4 Vinyl Low-E Double Yes
0.34 0.23 N
20.0 ft2 1 ft 0 in
2 ft 0 in Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
408 ft2 408 ft2
45 ft
9 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .0004
1969.8 108.07 202.89 .1324
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ None
Singl HSPF:9
29.2 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/ None
Singl SEER: 16 29.2 kBtu/hr 876 cfm 0.73 1
sys#1
7/14/2021 7:32'AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use
SetPnt
Conservation
1
Electric None
Garage 0.95 50 gal 47 gal
120 deg
None
SOLAR HOT WATER.SYSTEM
FSEC
Collector Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft'
DUCTS
J
---- Supply ---
-- Return ----
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location Area Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1
Attic. 6 320 ftz
Main 20 ft' Proposed Qn
Main
— elm
131.3 cfm 0.07 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[[X Jan
X.] Feb Mar
X A r X]] Ma [[XX]] Jun [[X Jul
[Xj Au
X]] Se
X] Oct X Nov
Dec
X
Heatin[X� Jan
XI Feb rX Mar
X Apr May X] Jun X� Jul
X] Aug
Sep
IX] Oct Nov
Dec
Venting [X Jan
X]] Feb Mar
lX]
X Apr [X]) May XXll Jun X Jul
Xl Aug
lX]
[[X]] Sep
[X, Oct [X Nov
lX�
[X Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3 4 5 6
7
8
9
10 11
12
Cooling (WD)
AM 78
78 78 78 78 78
78
78
80
80 80
80
PM 80
80 78 78 78 78
78
78
78
78 78
78
Cooling (WEH)
AM 78
78 78 78 78 78
78
78
78
78 78
78
PM 78
78 78 78 78 78
78
78
78
78 78
78
Heating (WD)
AM 66
66 66 66 66 68
68
68
68
68 68
68
PM 68
68 68 68 68 68
68
68
68
68 66
66
Heating (WEH)
AM 66
66 66 66 66 68
68
68
68
68 68
68
PM 68
68 68 68 68 68
68
68
68
68 66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run Time Cooling System
None
0
0 0 0 1 - Electric Heat Pump
0%
1 - Central Unit
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft' 0 ft
0.3
Main
7/14/2021 7:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX` = 92
The lower the EnergyPerformance Index, the more efficient the home.
5602 SHANNON DRIVE, Fort Pierce, FL, 34950
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1473.30 ft2
b. Frame - Wood, Adjacent
R=13.0
173.33 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
5. Is this a worst case?
Yes
a. Under Attic (Vented)
R=30.0
1876.00 ft
6. Conditioned floor area (ft2)
1876
b. N/A
R=
_ ft2
c. N/A
R=
ft2
7. Windows** Description
Area
12. Ducts, location & insulation level
R ft
a. U-Factor. Dbl, U=0.34
100.00 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 320
SHGC: SHGC=0.23
b. U-Factor. Dbl, U=0.55
40.00 ft2
SHGC: SHGC=0.25
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
29.2
SEER:16.00
SHGC:
d. U-Factor: N/A
ft2
14. Heating systems -
kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump
29.2
HSPF:9.00
Area Weighted Average Overhang Depth:
1.000 ft.
Area Weighted Average SHGC:
0.236
8. Skylights Description
Area
15. Hot water systems
Cap:
50 gallons
a. U-Factor(AVG): N/A
2
ft2
a. Electric
EF:0.95
SHGC(AVG): NIA
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1876.00 ft2
Credits (Performance method)
Pstat
b. NIA
R=
ft2
c. NIA
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code com t featur s / \
Builder Signature: Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/14/2021 7:32 AM EnergyGauge RO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: 186A LH - FP010153 Builder Name: FOCUS HOMES
Street: 5602 SHANNON DRIVE Permit Office:
City, State, Zip: Fort Pierce , FL, 34950 Permit Number:
Y
U
Owner: FOCUS HOMES Jurisdiction:
w
x
Design Location: FL, ST_LUCIE_CO_INTL
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as,
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be.sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire surinkler cover plates and walls or ceiloncis.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
7/14/2021 7:32 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1