Loading...
HomeMy WebLinkAboutEnergy Efficiency Codei RM R405-2020 OFfDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method �r p 9 Project Name: 269A RH - FP260056 Street: 8407 Deland ave. City, State. Zip: Fort Pierce, FL, 34951 - Owner: FOCUS HOMES ,'Design Location: FL, ST LUCIE_CO_INTL Builder Name: FOCUS HOMES Permit Office: Permit Number: Jurisdiction: County: St. Lucie (Florida Climate Zone 2 ) V -New construction or existing New (From Plans) 10. Wall Type42480.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Frame -Wood, Exterior R=13.0 1312.00 ft' b. Concrete Block - Int Insul, Exterior R=4.1 928.00 ft' 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 240.00 ft' 4. Number of Bedrooms 4 d. N/A R=. ftZ 11. Ceiling Types (1573.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1573.00 ft 6. Conditioned floor area above grade (ft') 2657 b. N/A R= ft-2 Conditioned floor area below grade (ft') 0 c. N/A R= ftZ 7. Windows(205.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft' 6 315 a. U-Factor. Dbl, U=0.60 205.00 ft' SHGC: SHGC=0.32 b. U-Factor. NIA ft' 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.4 SEER:16.00 c. U-Factor: N/A ft' SHGC: Area Weighted Average Overhang Depth: 1.000 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.320 a. Electric Heat Pump 34.4 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) NIA ft' 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1573.0 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 1119.00 ft' b. Conservation features b. Floor over Garage R=19.0 454.00 ft' None c. N/A R= ft' 16. Credits Pstat Glass/Floor Area: 0.077 Total Proposed Modified Loads: 65.31 PASS Total Baseline Loads: 74.14 I hereby certify that the plans and sp cations covered by this calculation are in compliance i the Flo$' nergy Code. PREPAR D DATE: _ Z! I hereby certify that this building, as designed, is in compliance with the Florida Ener OWNER/AGENT: waL DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: SxA���.� fr nrur• `fin.,, ``.` „c n O L4.. ...... st*: iio lance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as ':factory -sealed in accordance with R403.3.2.1. - C6rr.,._.'1nce requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 On for whole house. I 6/11/2021 3:32 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4 1. Y• .4, F "405-2020 INPUT SUMMARY.CHECKLIST REPORT PROJECT 269A RH - FP260056 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2657 Lot # Owner Name: FOCUS HOMES Total Stories: 2 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: FOCUS HOMES Rotate Angle: 0 Street: 8407 Deland ave. Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: Fort Pierce , " Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2657 22053.1 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2657 22053.1 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulalio Main 148 ft 0 1119 ft2 ---- 0 0.25 0.75 2 Floor over Garage Main ---- --- 454 ft2 19 0 0 1 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1759 ft2 0 ft2 Medium N 0.85 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1573 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1573 ft2 0.11 Wood K 6/11/2021 3:32 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below 1/ #-Omt To WalLTYpP Space R-value Ft In Ft In Area R-yalue-Fraction-Absor_GradeJ� 1 N Exterior Concrete Block - Int Insul Main 4.0999 10 0 8 0 80.0 ft2 0 0 0.75 0 2 E Exterior Concrete Block - Int Insul Main 4.0999 44 0 8 0 352.0 ft2 0 0 0.75 0 3 S Exterior Concrete Block - Int Insul Main 4.0999 30 0 8 0 240.0 ft2 0 0 0.75 0 4 W Exterior Concrete Block - Int Insul Main 4.0999 32 0 8 0 256.0 ft2 0 0 0.75 0 5 N Exterior Frame - Wood Main 13 30 0 8 0 240.0 ft2 0 0.23 0.75 0 6 E Exterior Frame - Wood Main 13 52 0 8 0 416.0 ft2 0 0.23 0.75 0 -7 S Exterior Frame - Wood Main 13 30 0 8 0 240.0 ft2 0 0.23 0.75 0 8 W Exterior Frame - Wood Main 13 52 0 8 0 416.0 ft2 0 0.23 0.75 0 9 N Garage Frame - Wood Main 13 30 0 8 0 240.0 ft2 0.23 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .4 2.7 6 8 18 ft2 2 N Insulated Main None .4 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation (=>) changed to Worst Case. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Double Yes 0.6 0.32 N 20.0 ft2 1 ft 0 in 12 ft 0 in Drapes/blinds None 2 E 2 Metal Low-E Double Yes 0.6 0.32 N 15.0 ft2 1 ft 0 in 12 ft 0 in Drapes/blinds None 3 S 3 Metal Low-E Double Yes 0.6 0.32 N 30.0 ft2 1 ft 0 in 12 ft 0 in Drapes/blinds None 4 S 3 Metal Low-E Double Yes 0.6 0.32 N 40.0 ft2 1 ft 0 in 12 ft 0 in Drapes/blinds None 5 N 5 Metal Low-E Double Yes 0.6 0.32 N 30.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 6 N 5 Metal Low-E Double Yes 0.6 0.32 N 20.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 7 S 7 Metal Low-E Double Yes 0.6 0.32 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 8 W 8 Metal Low-E Double Yes 0.6 0.32 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 W 8 Metal Low-E Double Yes 0.6 0.32 N 20.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 454 ft2 454 ft2 32 ft 8 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA Eq A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000369 2572.9 141.15 265 .1692 7 6/11/2021 3:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singl HSPF:8.5 34.4 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Singl SEER: 16 34.4 kBtu/hr 1200 cfm 0.73 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 59 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS --- Supply ---- V # Location R-Value Area --- Return --- Air Location Area Leakage Type Handler CFM 25 TOT CFM25 OUT QN RLF HVAC # Heat Cool 1 Attic 6 315 ft2 Main 20 ft2 Proposed Qn Main — cfm 0.0 cfm 0.00 0.30 1 1 TEMPERATURES Programable Thermostat: Y Cooling[Xi Jan [[X]] Feb jXj] Mar Heatin[X] Jan IXI Feb [X] Mac Venting [[XJJ Jan [X Feb [X] Mar Ceiling Fans: jjXjj A r FX]I May X]] Jun [[Xjj Jul FXJ Au [X]Apr l�1 May EX] Jun IX] Jul Aug [[X]] Apr [X] May [[X]] Jun [[X]] Jul Aug Xjj Se ] Sep X]] Sep IX Xjj Oct ] Oct Xjj Oct IX Xjj Nov ] Nov X]] Nov IX �XXJ Dec Dec XDec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 Cooling (WEH) AM 78 PM 78 Heating (WD) AM 66 PM 68 Heating (WEH) AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 68 68 66 66 68 68 68 68 68 68 78 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 0 1 - Electric Heat Pump 0% 1 -Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Main 6/11/2021 3:32 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 88 The lower the EnergyPerformance Index, the more efficient the home. 8407 Deland ave. , Fort Pierce, FL, 34951 I. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Frame - Wood, Exterior R=13.0 1312.00 ft2 b. Concrete Block - Int Insul, Exterior R=4.1 928.00 ft 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 240.00 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1573.00 ft2 6. Conditioned floor area (ft2) 2657 b. N/A R= ft2 7. Windows- Description Area c. NIA R= ft a. U-Factor. Dbl, U=0.60 205.00 ft2 12. Ducts, location & insulation level 2 R ft a. Sup: Attic, Ret: Main, AH: Main 6 315 SHGC: SHGC=0.32 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.4 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 34.4 HSPF:8.50 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.320 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.95 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1119.00 ft2 Credits (Performance method) Pstat b. Floor over Garage R=19.0 454.00 ft2 c. N/A R= ft2 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. A'/ Builder Signature: Date: Address of New Home: ` - City/FL Zip: OF -T14E S: 1 D Wr- *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. ' 6/11/2021 3:32 PM EnergyGauge® USA 7.0.00- FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT .CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 269A RH - FP260056 Builder Name: FOCUS HOMES Street: 8407 Deland ave. Permit Office: City, State, Zip: Fort Pierce ; FL, 34951 Permit Number: Y U Owner: FOCUS HOMES Jurisdiction: _ Design Location: FL, ST_LUCIE_CO_INTL U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee walldoors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace.wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind 6pingwiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilincis. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/11/2021 3:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1