HomeMy WebLinkAboutEnergy Efficiency Codei
RM R405-2020
OFfDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
�r p 9
Project Name:
269A RH - FP260056
Street:
8407 Deland ave.
City, State. Zip:
Fort Pierce, FL, 34951
- Owner:
FOCUS HOMES
,'Design Location:
FL, ST LUCIE_CO_INTL
Builder Name: FOCUS HOMES
Permit Office:
Permit Number:
Jurisdiction:
County: St. Lucie (Florida Climate Zone 2 )
V -New construction or existing
New (From Plans)
10. Wall Type42480.0 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Frame -Wood, Exterior
R=13.0 1312.00 ft'
b. Concrete Block - Int Insul, Exterior
R=4.1 928.00 ft'
3. Number of units, if multiple family
1
c. Frame - Wood, Adjacent
R=13.0 240.00 ft'
4. Number of Bedrooms
4
d. N/A
R=. ftZ
11. Ceiling Types (1573.0 sqft.)
Insulation Area
5. Is this a worst case?
Yes
a. Under Attic (Vented)
R=30.0 1573.00 ft
6. Conditioned floor area above grade (ft')
2657
b. N/A
R= ft-2
Conditioned floor area below grade (ft')
0
c. N/A
R= ftZ
7. Windows(205.0 sqft.) Description
Area
12. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft'
6 315
a. U-Factor. Dbl, U=0.60
205.00 ft'
SHGC: SHGC=0.32
b. U-Factor. NIA
ft'
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
34.4 SEER:16.00
c. U-Factor: N/A
ft'
SHGC:
Area Weighted Average Overhang Depth:
1.000 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.320
a. Electric Heat Pump
34.4 HSPF:8.50
8. Skylights
Area
c. U-Factor:(AVG) NIA
ft'
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1573.0 sqft.)
Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation
R=0.0 1119.00 ft'
b. Conservation features
b. Floor over Garage
R=19.0 454.00 ft'
None
c. N/A
R= ft'
16. Credits
Pstat
Glass/Floor Area: 0.077
Total Proposed Modified Loads: 65.31
PASS
Total Baseline
Loads: 74.14
I hereby certify that the plans and sp cations covered by
this calculation are in compliance i the Flo$' nergy
Code.
PREPAR D
DATE: _ Z!
I hereby certify that this building, as designed, is in compliance
with the Florida Ener
OWNER/AGENT:
waL
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
SxA���.�
fr nrur• `fin.,, ``.` „c n O
L4.. ...... st*:
iio lance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
':factory -sealed in accordance with R403.3.2.1.
- C6rr.,._.'1nce requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 On for whole house.
I
6/11/2021 3:32 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4
1.
Y•
.4,
F "405-2020 INPUT SUMMARY.CHECKLIST REPORT
PROJECT
269A RH - FP260056
Bedrooms: 4
Address Type: Street Address
Building Type:
User
Conditioned Area: 2657
Lot #
Owner Name:
FOCUS HOMES
Total Stories: 2
Block/Subdivision:
# of Units:
1
Worst Case: Yes
PlatBook:
Builder Name:
FOCUS HOMES
Rotate Angle: 0
Street: 8407 Deland ave.
Permit Office:
Cross Ventilation: No
County: St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip: Fort Pierce ,
" Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating Design Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2657 22053.1
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2657 22053.1 Yes 5
4
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood Carpet
1 Slab -On -Grade Edge Insulalio
Main 148 ft 0
1119 ft2
---- 0 0.25 0.75
2 Floor over Garage
Main ---- ---
454 ft2
19 0 0 1
ROOF
Roof Gable Roof
Rad
Solar SA Emitt Emitt Deck Pitch
#
Type Materials Area Area Color
Barr
Absor. Tested Tested Insul. (deg)
1
Hip Composition shingles 1759 ft2 0 ft2 Medium
N
0.85 No 0.9 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1573 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1573 ft2 0.11 Wood
K
6/11/2021 3:32 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
1/ #-Omt
To
WalLTYpP
Space
R-value Ft In
Ft In Area R-yalue-Fraction-Absor_GradeJ�
1
N
Exterior
Concrete Block - Int Insul
Main
4.0999 10 0
8 0
80.0 ft2
0
0 0.75
0
2
E
Exterior
Concrete Block - Int Insul
Main
4.0999 44 0
8 0
352.0 ft2
0
0 0.75
0
3
S
Exterior
Concrete Block - Int Insul
Main
4.0999 30 0
8 0
240.0 ft2
0
0 0.75
0
4
W
Exterior
Concrete Block - Int Insul
Main
4.0999 32 0
8 0
256.0 ft2
0
0 0.75
0
5
N
Exterior
Frame - Wood
Main
13 30 0
8 0
240.0 ft2
0
0.23 0.75
0
6
E
Exterior
Frame - Wood
Main
13 52 0
8 0
416.0 ft2
0
0.23 0.75
0
-7
S
Exterior
Frame - Wood
Main
13 30 0
8 0
240.0 ft2
0
0.23 0.75
0
8
W
Exterior
Frame - Wood
Main
13 52 0
8 0
416.0 ft2
0
0.23 0.75
0
9
N
Garage
Frame - Wood
Main
13 30 0
8 0
240.0 ft2
0.23 0.75
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated
Main
None
.4
2.7
6 8
18 ft2
2
N
Insulated
Main
None
.4
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation (=>) changed to Worst Case.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Metal Low-E Double
Yes
0.6 0.32 N
20.0 ft2
1 ft 0 in
12 ft 0 in
Drapes/blinds
None
2
E 2
Metal Low-E Double
Yes
0.6 0.32 N
15.0 ft2
1 ft 0 in
12 ft 0 in
Drapes/blinds
None
3
S 3
Metal Low-E Double
Yes
0.6 0.32 N
30.0 ft2
1 ft 0 in
12 ft 0 in
Drapes/blinds
None
4
S 3
Metal Low-E Double
Yes
0.6 0.32 N
40.0 ft2
1 ft 0 in
12 ft 0 in
Drapes/blinds
None
5
N 5
Metal Low-E Double
Yes
0.6 0.32 N
30.0 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
6
N 5
Metal Low-E Double
Yes
0.6 0.32 N
20.0 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
7
S 7
Metal Low-E Double
Yes
0.6 0.32 N
15.0 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
8
W 8
Metal Low-E Double
Yes
0.6 0.32 N
15.0 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
9
W 8
Metal Low-E Double
Yes
0.6 0.32 N
20.0 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
454 ft2 454 ft2
32 ft
8 ft
13
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA Eq A
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000369
2572.9 141.15
265
.1692
7
6/11/2021 3:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
None
Singl HSPF:8.5 34.4 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
None
Singl SEER: 16 34.4 kBtu/hr 1200 cfm
0.73
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 59 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
--- Supply ----
V # Location R-Value Area
--- Return --- Air
Location Area Leakage Type Handler
CFM 25
TOT
CFM25
OUT QN
RLF
HVAC #
Heat Cool
1 Attic 6 315 ft2
Main
20 ft2 Proposed Qn Main
— cfm
0.0 cfm 0.00
0.30
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling[Xi Jan [[X]] Feb jXj] Mar
Heatin[X] Jan IXI Feb [X] Mac
Venting [[XJJ Jan [X Feb [X] Mar
Ceiling Fans:
jjXjj A r FX]I May X]] Jun [[Xjj Jul FXJ Au
[X]Apr l�1 May EX] Jun IX] Jul Aug
[[X]] Apr [X] May [[X]] Jun [[X]] Jul Aug
Xjj Se
] Sep
X]] Sep
IX
Xjj Oct
] Oct
Xjj Oct
IX
Xjj Nov
] Nov
X]] Nov
IX
�XXJ Dec
Dec
XDec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6 7
8
9
10
11
12
Cooling (WD) AM 78
PM 80
Cooling (WEH) AM 78
PM 78
Heating (WD) AM 66
PM 68
Heating (WEH) AM 66
PM 68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78 78
78 78 78 78
78 78 78 78
78 78 78 78
66 66 68 68
68 68 68 68
66 66 68 68
68 68 68 68
78
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MECHANICAL VENTILATION
Type Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run Time Cooling System
None 0
0
0 0 1 - Electric Heat Pump
0%
1 -Central Unit
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft 0.3
Main
6/11/2021 3:32 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 88
The lower the EnergyPerformance Index, the more efficient the home.
8407 Deland ave. , Fort Pierce, FL, 34951
I. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Frame - Wood, Exterior
R=13.0
1312.00 ft2
b. Concrete Block - Int Insul, Exterior
R=4.1
928.00 ft
3. Number of units, if multiple family
1
c. Frame - Wood, Adjacent
R=13.0
240.00 ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
5. Is this a worst case?
Yes
a. Under Attic (Vented)
R=30.0
1573.00 ft2
6. Conditioned floor area (ft2)
2657
b. N/A
R=
ft2
7. Windows- Description
Area
c. NIA
R=
ft
a. U-Factor. Dbl, U=0.60
205.00 ft2
12. Ducts, location & insulation level
2
R ft
a. Sup: Attic, Ret: Main, AH: Main
6 315
SHGC: SHGC=0.32
b. U-Factor: N/A
ft2
SHGC:
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
34.4
SEER:16.00
SHGC:
d. U-Factor: N/A
ft2
14. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump
34.4
HSPF:8.50
Area Weighted Average Overhang Depth:
1.000 ft.
Area Weighted Average SHGC:
0.320
8. Skylights Description
Area
15. Hot water systems
Cap:
50 gallons
a. U-Factor(AVG): N/A
ft2
a. Electric
EF: 0.95
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1119.00 ft2
Credits (Performance method)
Pstat
b. Floor over Garage
R=19.0
454.00 ft2
c. N/A
R=
ft2
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. A'/ Builder Signature: Date:
Address of New Home: ` - City/FL Zip:
OF -T14E S:
1
D Wr-
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
' 6/11/2021 3:32 PM EnergyGauge® USA 7.0.00- FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT .CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: 269A RH - FP260056 Builder Name: FOCUS HOMES
Street: 8407 Deland ave. Permit Office:
City, State, Zip: Fort Pierce ; FL, 34951 Permit Number:
Y
U
Owner: FOCUS HOMES Jurisdiction:
_
Design Location: FL, ST_LUCIE_CO_INTL
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee walldoors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace.wall
.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind 6pingwiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilincis.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/11/2021 3:32 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1