HomeMy WebLinkAboutEnergy Efficiency Code 1-8-14FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Morris Residence
Builder Name:
Street: Lot 49 Nettles Island
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL ,
Permit Number
Owner. Morris
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (1776.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0 1328.00 ft2
b. Frame - Wood, Exterior
R=13.0 448.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (722.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 722.00 ft2
6. Conditioned floor area above grade (ft2) 1349
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
R= ft2
11. Ducts
R ft?
7. Windowst3W sqft.) I Description Area
a. Sup: Attic, Ret: Attic, AH: RoomslnBlockl 6 250
a. U-Factor. Sgl, U=J0.29 302.00 ft2
b. Sup: Attic, Ret: Attic, AH: RoomslnBlockl 6 250
SHGC: SHGC=0.30
b. U-Factor. N/A ft2
12. Cooling systems
kBtu/hr .Efficiency
SHGC:
a. Central Unit
19.0 SEER:16.00
b. Central Unit
19.0SEER:16.00
c. U-Factor. N/A ft2
.SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
28.8 COP:1.00
SHGC:
b. Electric Strip Heat
20.0 COP:1.00
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average' SHGC: 0.300
14. Hot water systems
a. Electric Tankless
Cap: 1 gallons
8. Floor Types (722.0 sqft.) Insulation Area
EF: 0.990
a. Slab -On -Grade Edge Insulation R=0.0 722.00 ft2
b. Conservation features
b. N/A R= ft2
-Add-on Dedicated HeatPump:COP=3.5
c._N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.224 Total Proposed Modified Loads: 23.42
PASS
Tot 1 Standard Reference Loads: 33.96
I hereby certify that the plans and specifi rtriton7cc�ed
Review of the plans and
0
this calculation are in compliance -with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
�220
f
�-'
with the Florida Energy Code.
PREPARED BY: ie�,il�l
DATE: tojAcc,"
Before construction is completed
this building will be inspected for
9 P
compliance with Section 553.908
W
, �
I hereby certify that this b ' ing, as designed, is in compliance
Florida Statutes.,
�4,
COD
with the Florida Energy e.
WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
-
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
1
10/24/2013 9:16 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
a� t..
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX` = 69
The lower the EnergyPerformance Index, the more efficient the home.
Lot 49 Nettles Island, Fort Pierce, FL,
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor. Sgl, U=0.29
SHGC: SHGC=0.30
b. U-Factor. N/A
SHGC:
c. U-Factor: N/A
SHGC:
d. U-Factor. N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
New (From Plans)
Single-family
1
3
No
1349
Area
302.00 ft2
Insdlation
R=0.0
R=
R=
ft2
ft2
ft2
0.000 ft.
0.300
Area
722.00 ft2
ft2
ft2
9. Wall Types
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=5.0
1328.00 ft2
b. Frame -Wood, Exterior
R=13.0
448.00 ft2
c. NIA
R=
ft2
d. WA
R=
ft2
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
722.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: RoomslnBlockl
6 250
b. Sup: Attic, Ret: Attic, AH: RoomslnBlockl
6 250
12. Cooling systems
kBtu/hr
Efficiency
a. Central Unit
19.0 SEER:16.00
b. Central Unit
19.0 SEER:16.00
13. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
28.8
COP:1.00
b. Electric Strip Heat
20.0
COPA.00
14. Hot water systems
a. Electric
Cap: 1 gallons
EF: 0.91
b. Conservation features
Add -on Dedicated HeatPump:COP=3.5
15. Credits
CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code mpliant features.
Builder Signature: Date: /
Address of New Ho ' :�E /��s� City/FL Zip:
9
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
0
PROJECT
Title:
Morris Residence
Bedrooms: 3
Address Type:
Street Address
Building Type:
FLProp2010
Conditioned Area: 1349
Lot #
Owner.
Morris
Total Stories: 2
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 225
Street:
Lot 49 Nettles Island
Permit Office:
St. Lucie County
Cross Ventilation:
County:
ST. Lucie
Jurisdiction:
Whole House Fan:
City, State, Zip:
Fort Pierce,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
lnt Design Temp Heating
Design Daily Temp
Design Location
TMY Site Zone 97.5 % 2.5 %
-Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_ST LUCIE CO_INTL 2 39 90
70
75 722
62
Low
BLOCKS
Number
Name
Area Volume
1
Block1
627 5016
2
Block2
722 5776
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
RoomslnBlock1
627 5016 No 1.39436619 2
1 Yes
Yes
Yes
2
RoomslnBlock2
722 5776 Yes 1.60563380 1
2 Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio RoomslnBlockl 627 ft 0
722 ft2
____
0 0
1
ROOF
/
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Hip
Metal 782 ft2 0 ft2 Medium
0.96
No 0.9
No 0
22.6
ATTIC
/
V
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 722 ft2
N N
10/24/2013 9:18 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
CEILING
#
Ceiling Type
Space
R-Value
Area
Framing Frac
Truss Type
1
Under Attic (Vented)
RoomslnBlock2 30
722 ft2
0.11
Wood
WALLS
Adjacent
OrntTo Wall -Type
Space
Cavity
R-value
Width
Et In
Height Sheathing Framing Solar Below
Et_ln Area R value__Eraction._Mso"rad °
1 N
Exterior
Frame - Wood
RoomslnBloc
13
11
8
88 ft2
0.23 0.75
0
2 N
Exterior
Frame - Wood
RoomslnBloc
13
21
8
168 ft2
0.23 0.75
0
3, N
Exterior
Concrete Block - Int
InsRoomsInBloc
5
13
8
104 ft2
0 0.75
0
4 E
Exterior
Concrete Block - Int
Ins8l00mSlnBloc
5
23
8
184 ft2
0 0.75
0
5 E
Exterior
Concrete Block - Int
Insl3lOomsInBloc
5
36
8
288 ft2
0 0.75
0
6 S
Exterior
Frame - Wood
RoomslnBloc
13
14
8
112 ft2
0.23 0.75
0
7 S
Exterior
Concrete Block - Int
Ins610omSlnBloc
5
11
8
88 ft2
0 0.75
0
8 S
Exterior
Frame - Wood
RoomslnBloc
13
10
8
80 ft2
0.23 0.75
0
9 S
Exterior
Concrete Block - Int
Ins5loomslnBlor,
5
14
8
112 ft2
0 0.75
0
10 W
Exterior
Concrete Block - Int
Ins6loomslnBloc
5
33
8
264 ft2
0 0.75
0
11 W
Exterior
Concrete Block - Int Ins6loomslnBloc
5
36
8
288 ft2
0 0.75
0
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
S
Wood
RoomslnBloc
None
0.460000 3
7
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
# Omt ID
Frame Panes
NFRC U-Factor SHGC
Storms
Area
Depth
Separation
Int Shade Screening
1 N
1
Metal Single (Tinted)
Yes
0.29
0.3
N
35 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
2 N
2
Metal Single (Tinted)
Yes
0.29
0.3
N
56 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
3 N
2
Metal Single (Tinted)
Yes
0.29
0.3
N
42 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
4 N
3
Metal Single (Tinted)
Yes
0.29
0.3
N
30 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
5 E
4 ,
Metal Single (Tinted)
Yes
0.29
0.3
N
9 ft2
0 It 0 in
0 ft 0 in
HERS 2006
None
6 E
5
Metal Single (Tinted)
Yes
0.29
0.3
N
12 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
7 E
5
Metal Single (Tinted)
Yes
0.29
0.3
N
15 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
8 S-
7
Metal Single (Tinted)
Yes
0.29
0.3
N
12 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
9 S
8
Metal Single (Tinted)
Yes
0.29
0.3
N
35 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
10 S
9
Metal Single (Tinted)
Yes
0.29
0.3
N
15 ft2
,0 ft 0 in
0 ft 0 in
HERS 2006
None
11 W
10
Metal Single (Tinted)
Yes
0.29
0.3
N
15 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
12 W
11
Metal Single (Tinted)
Yes
0.29
0.3
N
18 ft2
0 ft 0 in
0 It 0 in
HERS 2006
None
13 W
11
Metal Single (Tinted)
Yes
0.29
0.3
N
8 ft2
0 ft 0 in
0 It 0 in
HERS 2006
None
10/24/2013 9:16 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
382.8 ft2
382.8 ft2
1 64 ft 8 ft
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 BySpaces
2 BySpaces
Proposed SLA
Proposed SLA
0.000360
0.000360
592.06 32.503 61.127 0.3235
681.77 37.428 70.389 0.3235
7.0821
7.0821
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
2
Electric Strip Heat
Electric Strip Heat
None
None
COP: 1 28.8 kBtu/hr
COP: 1 20 kBtu/hr
1
2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit
Central Unit
None
None
SEER: 16 19 kBtu/hr 570 cfm 0.75 1
SEER: 16 19 kBtu/hr 570 cfm 0.75 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubTpe
Location
EF Cap Use SetPnt
Conservation
1
Electric Tankless
Garage
0.9108 1 gat 60 gal 120 deg
Add -on HeatPump:COP=3.5
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None
None
ft2
DUCTS
#
= Supply —
Location R-Value Area
— Return — Air
Location Area Leakage Type Handler CFM 25
Percent HVAC #
Leakage QN RLF Heat Cool
1
2
Attic 6. 250 ft2
Attic 6 250 ft2
Attic
Attic
67.45 ft DSE=0.88 RoomslnBI 0.0 cfm
67.45 ft DSE=0.88 RoomslnBI 0.0 cfm
0.00 % 0.00 0.60
0.00 % 0.00 0.60
1 1
2 2
10/24/2013 9:16 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Vent ng RjJan
Feb
[[XX]]
(X) Mar
XXJul
Aug
Sep
Oct
xX Nov
xX DecVenting
Jan
Feb
[[XXjj Mar
Apr
Xj May
XJun
X
X
X
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78,
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
'68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
10/24/2013 9:16 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: Lot 49 Nettles Island PERMIT #:
Fort Pierce, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage ileport or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
capacity system. Electric heat >10kW must be divided into two
Ivariable
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
10/24/2013 9:16 AM EnergyGauge® USA - F1aRes2010 Section 405.4.1 Compliant Software Page 6 of 6