Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 1-8-14FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Morris Residence Builder Name: Street: Lot 49 Nettles Island Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , Permit Number Owner. Morris Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1776.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1328.00 ft2 b. Frame - Wood, Exterior R=13.0 448.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (722.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 722.00 ft2 6. Conditioned floor area above grade (ft2) 1349 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft? 7. Windowst3W sqft.) I Description Area a. Sup: Attic, Ret: Attic, AH: RoomslnBlockl 6 250 a. U-Factor. Sgl, U=J0.29 302.00 ft2 b. Sup: Attic, Ret: Attic, AH: RoomslnBlockl 6 250 SHGC: SHGC=0.30 b. U-Factor. N/A ft2 12. Cooling systems kBtu/hr .Efficiency SHGC: a. Central Unit 19.0 SEER:16.00 b. Central Unit 19.0SEER:16.00 c. U-Factor. N/A ft2 .SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 28.8 COP:1.00 SHGC: b. Electric Strip Heat 20.0 COP:1.00 Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average' SHGC: 0.300 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (722.0 sqft.) Insulation Area EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 722.00 ft2 b. Conservation features b. N/A R= ft2 -Add-on Dedicated HeatPump:COP=3.5 c._N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.224 Total Proposed Modified Loads: 23.42 PASS Tot 1 Standard Reference Loads: 33.96 I hereby certify that the plans and specifi rtriton7cc�ed Review of the plans and 0 this calculation are in compliance -with the Florida Energy specifications covered by this Code. calculation indicates compliance �220 f �-' with the Florida Energy Code. PREPARED BY: ie�,il�l DATE: tojAcc," Before construction is completed this building will be inspected for 9 P compliance with Section 553.908 W , � I hereby certify that this b ' ing, as designed, is in compliance Florida Statutes., �4, COD with the Florida Energy e. WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 1 10/24/2013 9:16 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 a� t.. ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX` = 69 The lower the EnergyPerformance Index, the more efficient the home. Lot 49 Nettles Island, Fort Pierce, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor. Sgl, U=0.29 SHGC: SHGC=0.30 b. U-Factor. N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A New (From Plans) Single-family 1 3 No 1349 Area 302.00 ft2 Insdlation R=0.0 R= R= ft2 ft2 ft2 0.000 ft. 0.300 Area 722.00 ft2 ft2 ft2 9. Wall Types Insulation Area a. Concrete Block - Int Insul, Exterior R=5.0 1328.00 ft2 b. Frame -Wood, Exterior R=13.0 448.00 ft2 c. NIA R= ft2 d. WA R= ft2 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=30.0 722.00 ft2 b. N/A R= ft2 c. N/A R= ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: RoomslnBlockl 6 250 b. Sup: Attic, Ret: Attic, AH: RoomslnBlockl 6 250 12. Cooling systems kBtu/hr Efficiency a. Central Unit 19.0 SEER:16.00 b. Central Unit 19.0 SEER:16.00 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 28.8 COP:1.00 b. Electric Strip Heat 20.0 COPA.00 14. Hot water systems a. Electric Cap: 1 gallons EF: 0.91 b. Conservation features Add -on Dedicated HeatPump:COP=3.5 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code mpliant features. Builder Signature: Date: / Address of New Ho ' :�E /��s� City/FL Zip: 9 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software 0 PROJECT Title: Morris Residence Bedrooms: 3 Address Type: Street Address Building Type: FLProp2010 Conditioned Area: 1349 Lot # Owner. Morris Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 225 Street: Lot 49 Nettles Island Permit Office: St. Lucie County Cross Ventilation: County: ST. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Fort Pierce, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp lnt Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % -Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST LUCIE CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 627 5016 2 Block2 722 5776 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 RoomslnBlock1 627 5016 No 1.39436619 2 1 Yes Yes Yes 2 RoomslnBlock2 722 5776 Yes 1.60563380 1 2 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio RoomslnBlockl 627 ft 0 722 ft2 ____ 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 782 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 722 ft2 N N 10/24/2013 9:18 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) RoomslnBlock2 30 722 ft2 0.11 Wood WALLS Adjacent OrntTo Wall -Type Space Cavity R-value Width Et In Height Sheathing Framing Solar Below Et_ln Area R value__Eraction._Mso"rad ° 1 N Exterior Frame - Wood RoomslnBloc 13 11 8 88 ft2 0.23 0.75 0 2 N Exterior Frame - Wood RoomslnBloc 13 21 8 168 ft2 0.23 0.75 0 3, N Exterior Concrete Block - Int InsRoomsInBloc 5 13 8 104 ft2 0 0.75 0 4 E Exterior Concrete Block - Int Ins8l00mSlnBloc 5 23 8 184 ft2 0 0.75 0 5 E Exterior Concrete Block - Int Insl3lOomsInBloc 5 36 8 288 ft2 0 0.75 0 6 S Exterior Frame - Wood RoomslnBloc 13 14 8 112 ft2 0.23 0.75 0 7 S Exterior Concrete Block - Int Ins610omSlnBloc 5 11 8 88 ft2 0 0.75 0 8 S Exterior Frame - Wood RoomslnBloc 13 10 8 80 ft2 0.23 0.75 0 9 S Exterior Concrete Block - Int Ins5loomslnBlor, 5 14 8 112 ft2 0 0.75 0 10 W Exterior Concrete Block - Int Ins6loomslnBloc 5 33 8 264 ft2 0 0.75 0 11 W Exterior Concrete Block - Int Ins6loomslnBloc 5 36 8 288 ft2 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood RoomslnBloc None 0.460000 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 0.29 0.3 N 35 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 2 N 2 Metal Single (Tinted) Yes 0.29 0.3 N 56 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 3 N 2 Metal Single (Tinted) Yes 0.29 0.3 N 42 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 4 N 3 Metal Single (Tinted) Yes 0.29 0.3 N 30 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 5 E 4 , Metal Single (Tinted) Yes 0.29 0.3 N 9 ft2 0 It 0 in 0 ft 0 in HERS 2006 None 6 E 5 Metal Single (Tinted) Yes 0.29 0.3 N 12 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 7 E 5 Metal Single (Tinted) Yes 0.29 0.3 N 15 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 8 S- 7 Metal Single (Tinted) Yes 0.29 0.3 N 12 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 9 S 8 Metal Single (Tinted) Yes 0.29 0.3 N 35 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 10 S 9 Metal Single (Tinted) Yes 0.29 0.3 N 15 ft2 ,0 ft 0 in 0 ft 0 in HERS 2006 None 11 W 10 Metal Single (Tinted) Yes 0.29 0.3 N 15 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 12 W 11 Metal Single (Tinted) Yes 0.29 0.3 N 18 ft2 0 ft 0 in 0 It 0 in HERS 2006 None 13 W 11 Metal Single (Tinted) Yes 0.29 0.3 N 8 ft2 0 ft 0 in 0 It 0 in HERS 2006 None 10/24/2013 9:16 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 1 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 BySpaces 2 BySpaces Proposed SLA Proposed SLA 0.000360 0.000360 592.06 32.503 61.127 0.3235 681.77 37.428 70.389 0.3235 7.0821 7.0821 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat Electric Strip Heat None None COP: 1 28.8 kBtu/hr COP: 1 20 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit None None SEER: 16 19 kBtu/hr 570 cfm 0.75 1 SEER: 16 19 kBtu/hr 570 cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.9108 1 gat 60 gal 120 deg Add -on HeatPump:COP=3.5 SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # = Supply — Location R-Value Area — Return — Air Location Area Leakage Type Handler CFM 25 Percent HVAC # Leakage QN RLF Heat Cool 1 2 Attic 6. 250 ft2 Attic 6 250 ft2 Attic Attic 67.45 ft DSE=0.88 RoomslnBI 0.0 cfm 67.45 ft DSE=0.88 RoomslnBI 0.0 cfm 0.00 % 0.00 0.60 0.00 % 0.00 0.60 1 1 2 2 10/24/2013 9:16 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Vent ng RjJan Feb [[XX]] (X) Mar XXJul Aug Sep Oct xX Nov xX DecVenting Jan Feb [[XXjj Mar Apr Xj May XJun X X X Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78, 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 '68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/24/2013 9:16 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: Lot 49 Nettles Island PERMIT #: Fort Pierce, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage ileport or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or capacity system. Electric heat >10kW must be divided into two Ivariable or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 10/24/2013 9:16 AM EnergyGauge® USA - F1aRes2010 Section 405.4.1 Compliant Software Page 6 of 6