Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
HVAC Load Calculations
f Morris Residence HVAC Load Calculations for Morris Lot 49 Nettles Island Fort Pierce, Florida FZuSIDICHMAL FNI71VAC SAC L oADs Prepared By: Residential Energy Calc's Thursday, October 24, 2013 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac Residential $-Light Commercial HVAC Loads, ` Elite Software Development,, Inc. Residential Energy dales Morris Residence Port•Saint Lucie, FL 34.983' .. - Page 2` Pro eC-t Report " General Project Information Project Title: Morris Residence Designed By: QEA Associates Project Date: Monday, October 07, 2013 Client Name: Morris Client Address: Lot 49 Nettles Island Client City: Fort Pierce, Florida Company Name: Residential Energy Calc's Design Data Reference City: Fort Pierce; Florida Building Orientation: Front door faces South Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hurn Rel.Hum Dry Bulb Difference Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75 61 CheckFigures:, Total Building Supply CFM: 1,174 CFM Per Square "ft.: 0.870 Square ft. of Room Area: 1,349 Square ft. Per Ton: 460 Volume (ft) of Cond. Space: 10,791 Build 44 Loads. " Total Heating Required Including Ventilation Air: 28,276 Btuh 28.276 MBH Total Sensible Gain: 27,122 Btuh 77 % Total Latent Gain: 8,058 Btuh 23 % Total Cooling Required Including Ventilation Air: 35,180 Btuh 2.93 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac Residential &-LightCommercial HVAC Loads- Elite Software Development, lnc:_' . ;e Residential Energy CAl s Morris Residence" a Port Saint Lucie, FL 34983 Page 3 Miscellaneous 'Report 1 <Rheem Or Equivalent ', :Outdoor; � Outdoor ; Outdoor Indoor ;: Indoor Grains [System InputData, K Qry.Bulb Wet Bulb, Rel.HumRel. Hum Dry Bulb Difference Winter: 42 39.4 80% n/a. 70 n/a Summer: 90 78 59% 50% 75 61.09 System 2 Rheem-Or Equivalent Outdoor:.; } Outdoor Outdoor', Indoor Indoor' Grains Input -Data >DryBulb Wet,Bulb.. •Rel.Hum Rel.Hum;: Dry Bulb," Difference' Winter: 42 39.4 80% n/a 70 n/a Summer: 90 78 59% 50% 75_ 61.09 J,b6ct$izi�nd inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./l00 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside AirData Winter Summer Infiltration Specified: 0.610 AC/hr 0.320 AC/hr 110 CFM 58 CFM Infiltration Actual: 0.415 AC/hr 0.000 AC/hr Above Grade Volume: X 10,791 Cu.ft. X 10,791 Cu.ft. 4,477 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 75 CFM 0 CFM Total Building Ventilation: 80 CFM 80 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 " = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.610 AC/hr (51 CFM), Construction: Average Summer Infiltration Specified: 0.320 AC/hr (27 CFM), Construction: Average ---System 2--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.610 AC/hr (59 CFM), Construction: Average Summer -Infiltration Specified: 0.320 AC/hr (31 CFM), Construction: Average Duct Load; Factor Scenarios, for System 1 Attic Duct Duct i Surface". From [Nq.' .T e: ' , Description; . Location Ceiling ,, Leakage - Insulation ti Area [T]MDD' 1 Supply Attic 16B 0.12 6 169 No 1 Return Attic 16B 0.12 6 94 No Duct Load Factor' Scenarios for System 2 ' Attic Duct Duct:' Surface ' From No. T pe., Description-' Location Ceilin Leakage Insulation - Area [T]MDD- 1 Supply Attic 16B 0.12 6 195 No 1 Return Attic 16B 0.12 6 36 No C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM 0 Knvac Kesrgenna1t Ugnt c.ommercrai nV �oaas CIIRVQUILWdLC WavulU�JIIICIII� 1114. Residential' Energy Cal" s Morns Residence: PortSamt Lucie. FL 34983 Page 4 Load Preview Scope Ton /Toni Areal Gain Gain) Gain) Lossl CM FNet M CFMM Act CFMI Duct Size ff Building 2.93 ' 460 ' 1,3491 27,122 8,058 , 35,180 28,276 ' 336 1,174 1,174 System 1 ... 1.47' 426 627 ..... 13,424 , -- -- 4,220 17 644 , 116,475, --_-. 185 s8 I 581 Ox0* ---------- -- - Duct Latent - ------ 760 - _ ._. _ . _-_ -- Zone_ 1 _ _ -. 627 ; �- . � _ 12,764 _ _ ' _ 14 244 , 4 --- 185 ®_ 581 — .. 1-Foyer - - _ 96; 1,245; _1,800_ ...14,564- 400• 1 645 -- 1 46 • -- 16 ---�®-- 57 1-0* 2-Stairway 68� 5081 01 ...w'___..2 508' _ 2,652 34 23' 1-0" 3-Laundry _ 321 1,479 4001 1,879 746. 10 67 1-0" 4-Bedroom 3 165 , 400 5,368 . 4,423 57 226 , 2-0* .. . --_._, ._._ _ 5-Bedroom2 ..- .__. _.-.-..._ -- _ —4,968 - _., ._ 400; . _ .... , 3,496; - _..._.. 3,969 - 52 ---- 141 _ 1-0* 6-Bath 1 _ _176'_3,096 90 1,468Y -200. 1,668 `-1,209 16,® 67 1-0* System 2 1 46' 494, 722 13 699 I 3 838 17 537 ' 12 801 T 150 5 593 OXO' Ventilation 6591 11660_ 2,320 ! 1231 Duct Latent 878 ;..... 878 Zone 2 722 13,039 1,300 ; ; .., 14,339 ' ..... .._... 11,570 _ .._ 150 I 593 7-Master Bedroom 143 3,6.85' 400 4,085 2,975 39! 168 270" 8-Walk In Closet 56 _ 2451 01 245 718 9 ® 11 1-0" 9-Master Bath 91— 202'�-- 0 202 570-7'= 9 1-0' 10 Kitchen - ...._ . - - -... - 168 , 4263 ; 600 4,863 ; 1 761 ! 2311 _ 194 2-0" _ 11-Living .. 200 i 3,6761300 3 976 ` T 4 637 60�® 167 2-0' 12-Stairway -- 64� 967 0. 967 • 909 • 121 --, 44 1-0* C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM 1;R11vac - Residential -4-Light Commercial HVAC,Loads'.:,.. Elite Software Development, Inc. Norris Residence 'Residential Ener&'Calds illo - I Pa66'5 Port ain ude, FL'349�3. Room or Source Minimum] Maximuml Rough.] Design j SPI Duct Duct Htg CIg Act. Duct Duct Name Velocity l Velocity Factorl, U1001 Loss l Velocity Flow Flow Flow Size System 1 Supply Ru nouts Zone 1 1 -Foyer Bu It -In 450 750 O 0.1 01 161 67 1-0 2-Stairway Built-in 450 750 0; 0.11, 0 34 23 1 3-Laundry Built-in 450 750 0, 0.11 0 10 67 1-0 --- - ----- -- 4-Bedroom 3 Built In 450 . ...... 750 0 . . . ........ . 0.11 0 57 . ..... 226, 2-0 5-Bedroom 2 Built-in 450' 750 0: 0.1 0 5 141 1-0 6-Bath I Built In 450 750 01 0.1 - ------ ----- -__- 0 M 67 1-0 Other Ducts In System I Supply Main Trunk 'Built -In 650, 900, 01 0.11 0i 185_M 581 OxO System 2 Su pply Ru-nouts-, ------ -- - ------ Zone 2 7-Master Bedroom Built -In 450 750' 0 0.1 0 39 168 2-0 ......... .. . . .... ...... 8-Walk In Closet Built In 450. 750 0 0.1. 0, 9 11 1-0 9-Master Bath Built-in 450 750, 0 0.1 0, 7 9 1-0 1 0-Kitchen Built -In . 460 ...... ....... 750 01 0.11 0. 23 194' 2-0 1 I -Living Built-in 4501 750 0, 0.1 0, 60 167 2-0 12-Stairway Built -In 450 7501 - ------ --------- 0 - - 0.11 01 12 44 1-0 Other Ducts in System 2 Supply Main Trunk Built-in 650. 900 0E 0.1 0, 150 593 OX0 System 1 Heating Flow: 185 Cooling Flow: 581 System 2 Heating Flow: 150 Cooling Flow: 593 Q\ ... Worris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac Residential &, Light Commercial HVAC Loads Residential Energy Calc's Port, Saint• Lucie, k 34983 ... _, � .: = = � Elite Software Development, Inc. _ _ Morris Residence_ Page 11. Total Building, Summary Loads , = Component` ' Area Description ; . ;, ,Quan Sen Loss .. Lat., Gain ,' ; Sen, '; Gain Total" Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 60 1,815 0 3,284 3,284 metal frame withbreak, u-value 1.08, SHGC 0.75 1A-cm-o: Glazing -Single pane, operable window, clear, 35 1,244 0 1,220 1,220 metal frame no break, u-value 1.27, SHGC 0.75 1A-cb-o: Glazing -Single pane, operable window, clear, 69 1,140 _ 0 3,940 3,940 metal frame with break, u-value 0.59, SHGC 0.6 1A-cm-o: Glazing -Single pane,.operable window, clear, 150.5 2,487 0 .3,290 3,290 metal frame no break, u-value 0.59, SHGC 0.6 11 D: Door -Wood-- Solid Core 21 229 0 213 213 13A-5fcs: Wall -Block, board insulation only, R-5 board 1298 3,817 0 2,085 2,085 insulation, filled core, siding finish 1213-0sw: Part -Frame, R-11 insulation in 2 x 4 stud cavity,' 24 35 0 35 35 no, board insulation, siding finish, wood studs 12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud . 182.5 466 0 358 358 cavity, no board insulation, siding finish, wood studs 16F-30: Roof/Ceiling-Under Attic with Insulation on Attic 1348.9 1,211 0 648 648 Floor (also use for Knee Walls and. Partition Ceilings), Vented Attic, No Radiant Barrier, White Tile, Slate or Concrete, White Metal or White Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 112 4,259 0 0 0 insulation below floor, any floor cover, passive, heavy ' moist soil 20P-30: Floor -Over open crawl space or garage, Passive, 721.9 708 0 254 254 • R-30 blanket insulation, any cover Subtotals for structure: 17,411 0 15,327 15,327 People: 11 2,200 2,530 4,730 Equipment: 900 3,000 3,900 Lighting: 0 0 0 Ductwork: 6,109 1,638 4,947 6,584 Infiltration: Winter CFM: 75, Summer CFM: 0 2,294 0 0 0 Ventilation: Winter CFM: 80, Summer CFM: 80 _ 2,462_ _ 3,320 _ 1,319 _T 4,639 Total Building Load Totals: 28,276 8,058 27,122 35,180 ,Check Figures Total Building Supply CFM: 1,174 CFM Per Square ft.: 0.870 Square ft. of Room Area: 1,349 Square ft. Per Ton: 460 Volume (ft3) of Cond. Space: 10,791 Building Loads . Total Heating Required Including Ventilation Air: 28,276 Btuh 28.276 MBH Total Sensible Gain: 27,122 Btuh 77 % Total Latent Gain: 8,058 Btuh 23 % Total Cooling Required Including Ventilation Air: 35,180 Btuh 2.93 , Tons (Based On Sensible + Latent) ••Notes '� '' Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary: Be sure'to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at .your design conditions. C:\ ... \Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac Residential& Light Commercial HVAC Loads] Residential Energy' Pont Lucie, FL 34983 .... _ ' „ . ,. rt Sai Elite Software Development, Inc: Morris Residence' Pa a 1,5 System 2 Rheem 'Or Equivalent Summary Loads Component;. Area -en �. , DescnQuan Loss .. . , Lat-` Gain f `. Sen ' Gam Total> Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 69 1,140 0 3,940 3,940 metal frame with break, u-value 0.59, SHGC 0.6 1A-cm-o: Glazing -Single pane, operable window, clear, 150.5 2,487 0 3,290 3,290 metal frame no break, u-value 0.59, SHGC 0.6 13A-5fcs: Wall -Block, board insulation only, R-5 board 627 1,844 0 1,007 1,007 insulation, filled core, siding finish 12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud 97.5 249 0 191 191 cavity, no board insulation, siding finish, wood studs 16F-30: Roof/Ceiling-Under Attic with Insulation on Attic 721.9 648 0 348 348 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White Tile, Slate,or Concrete, White Metal or White Membrane, R-30 insulation 20P-30: Floor -Over open crawl space or garage, Passive, 721.9 708 0 254 254 R-30 blanket insulation, any cover Subtotals for structure'. 7,076 0 9,030 9,030 People: 2 400 460 860 Equipment: 900 1,200 2,100 Lighting: 0 0 0 Ductwork: 3,173 878 2,349 3,227 Infiltration: Winter CFM: 43, Summer CFM: 0 1,321 0 . 0 0 Ventilation: Winter CFM: 40, Summer CFM: 40 1,231 1,660 659 2,320 System 2 Rheem Or Equivalent Load Totals: 12,801 3,838 13,699 17,537 Check Figures .; Supply CFM: 593 CFM Per Square ft.: 0.822 Square ft. of Room Area: 722 Square ft. Per Ton: 494 Volume (fP) of Cond. Space: 5,775 S stem, -Loads, Total.Heating Required Including Ventilation Air: 12,801 Btuh 12.801 MBH Total Sensible Gain: 13,699 Btuh 78 % Total Latent Gain: 3,838 Btuh 22 % Total Cooling Required Including Ventilation Air: 17,537 Btuh 1.46 Tons (Based On Sensible + Latent) Notes a Rhvac is an ACCA approved Manual J and Manual. D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac Residentiafmm 8� Llght,Coercia! HVAC Loads Elite Software Development, Inc: Residential Energy Calds . ,, 1_"001rt°§aln't,Cucie, MoResidence ms ; FL U983 , ', Page 14 System" 1.Rheem Or Equivaient'.Summ' aty Loads omponent Area ,Sen Lat Sen ;Total'' [Pqescription QoanGam < '..,:Gam_ ` Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 60 1,815 0 3,284 3,284 metal frame with break, u-value 1.08, .SHGC 0.75 1A-cm-o: Glazing -Single pane, operable window, clear, 35 1,244 0 1,220 1,220 metal frame no break, u-value 1.27, SHGC 0.75 11 D: Door -Wood - Solid Core 21 229 0 213 213 13A-5fcs: Wall -Block, board insulation only, R-5 board 671 1,973 0 1,078 1,078 insulation, filled core, siding finish 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity, 24 35 0 35 35 no board insulation, siding finish, wood studs 12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud 85 217 0 167 167 cavity, no board .insulation, siding finish, wood studs 16F-30: Roof/Ceiling-Under Attic with Insulation on Attic 627 563 0 300 300 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White Tile, Slate or Concrete, White Metal or White Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 112 4,259 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 10,335 0 6,297 6,297 People: 9 1,800 2,070 3,870 Equipment: 0 1,800 1,800 Lighting: 0 0 0 Ductwork: 2,936 760 2,597 3,357 Infiltration: Winter CFM: 32, Summer CFM: 0 973 0 0 0 Ventilation: Winter CFM: 40, Summer CFM: 40 1,231 1,660 659 2,320 System 1 Rheem Or Equivalent Load Totals: 15,475 4,220 13,424 17,644 Check'Fi vies -` y Supply CFM: 581 CFM Per Square ft.: 0.926 Square ft. of Room Area: 627 Square ft. Per Ton: 426 Volume,(ft3) of Cond. Space: 5,016 Total Heating Required Including Ventilation Air: 15,475 Btuh 15.475 MBH Total Sensible Gain: 13,424 Btuh 76 % Total Latent Gain: 4,220 Btuh 24 % Total Cooling Required Including Ventilation Air: 17,644 Btuh 1.47 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac - Resideo_tial ;,,Light Commercial HVAC Loads Elite Software Development, Inc:' Residential Energy. Calc's ; ! , ` Morris Residence: Port Sa'int,Lucie, FL 83 .349�! Page 24 System 1; Zone T, Summary,Loads. (Average Load Procedure for Rooms) Component;:_ { . Area Description ' W%' Quan Sen Lat; Loss "'' Gain i .. Sen Gairi fotaF Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 60 1,815 0 3,284 3,284 metal frame with break, u-value 1.08, SHGC 0.75 IA-cm-o: Glazing -Single pane, operable window, clear, 35 1,244 0 1,220 1,220 metal frame no break, u-value 1.27, SHGC 0.75 11 D: Door -Wood - Solid Core 21 229 0 213 213 13A-5fcs: Wall -Block, board insulation only, R-5 board 671 1,973' 0 1,078 1,078 insulation, filled core, siding finish 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity, 24 35 0 35 35 no board insulation, siding finish, wood studs 12C-Osw:. Wall -Frame, R-13 insulation in 2 x 4 stud 85 217 0 167 167 cavity, no board insulation, siding finish, wood studs 16F-30: Roof/Ceiling-Under Attic with Insulation on Attic 627 563 0 300 300 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White Tile, Slate or Concrete, White Metal or White Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 112 4,259 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 10,335 0 6,297 6,297 People: 9 1,800 2,070 3,870 Equipment: 0 1,800 1,800 Lighting: 0 0 0 Ductwork: 2,936 0 2,597 2,597 Infiltration: Winter CFM: 32, Summer CFM: 0 973 0 0 0 System 1, Zone 1 Load Totals: 14,244 1,800 12,764 14,564 Check Fi ures Supply CFM: 581 CFM Per Square ft.: 0.926 Square ft. of Room Area: 627 Square ft. Per Ton: 517 Volume (ft3) of Cond. Space: 5,016 Zone Loads Total Heating Required: 14,244 Btuh 14.244 MBH Total Sensible Gain: 12,764 Btuh 88 % Total Latent Gain: 1,800 Btuh 12 % Total Cooling Required: 14,564 Btuh 1.21 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:1... \Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac m Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Residential, Energy Calc's Morris Residence, Port Samt.Lucie, FL 34983 . • ' a Pa a 25 .Sysferh 2, Zone 2 Summary.:Loads,_(A,verage Load Procedure for Rooms) Component,; Area Sen Lat. Sen Totaf' DesenptioniQuan Loss' Gain Gain ` Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 69 1,140 0 3,940 3,940 metal frame with break, u-value 0.69, SHGC 0.6 1A-cm-o: Glazing -Single pane, operable window, clear, 150.5 2,487 0 3,290 3,290 . metal frame no break, u-value 0,59, SHGC 0.6 13A-5fcs: Wall -Block, board insulation only, R-5 board 627 1,844 0 1,007 1,007 insulation, filled core, siding finish 12C-Osw: Wall -Frame, R-13 insulation in 2 x 4 stud 97.5 249 0 191 191 cavity, no board insulation, siding finish, wood studs 16F-30: Roof/Ceiling-Under Attic with Insulation on Attic 721.9 648 0 348 348 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White Tile, Slate or Concrete, White Metal or White Membrane, R-30 insulation .20P-30: Floor -Over open crawl space or garage, Passive, 721.9 708 0 254 254 R-30 blanket insulation, any cover Subtotals'for structure: 7,076 0 9,030 9,030 People: .2 400 460 860 Equipment: 900 1,200 2,100 Lighting: 0 0 0 Ductwork: 3,173 0 2,349 2,349 Infiltration: Winter CFM: 43, Summer CFM: 0 1,321 0 0 0 System 2, Zone 2 Load Totals: 11,570 1,300 13,039 14,339 Check Figures Supply CFM: 593 CFM Per Square ft.: 0.822 Square ft. of Room Area: 722 Square ft. Per Ton: 604 Volume (ft3) of Cond. Space: 5,775 ,Zone Loads Total Heating Required: 11,570 Btuh 11.570 MBH Total Sensible Gain: 13,039 Btuh 91 % Total Latent Gain: 1,300 Btuh 9 % Total Cooling Required`. 14,339 Btuh 1.19 Tons (Based On Sensible + Latent) ;Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac Residentia_ I & Light Commercial HVAC Loads Elite Software Development,.lnc.' Residential Energy CaVs Morns Residence. ,Port Saint Lucie, FL 34983 .'Pap 30 Detailed Room, Loads -,Room 1.- Fo er (Average.Load Procedure) General 77 Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 8.0 ft. Zone Number: 1 Area: 96.0 sq.ft. Supply Air: 57 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.4 AC/hr Volume: 768.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 57 CFM Percent of Supply.: 6 % Runout Duct Size: 0 in. Actual Summer Vent.: 4 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 7 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM item- A Area , s, U Htglgx Lat Sen: Description,Quaht{ Val HTM.°'.Loss'.HTM Gain-. Gain` S -Wall-13A-5fcs 6 X 8 21 0.105 2.9 62 1.6 0 34 E -Part-15°/15°-12B-Osw 3 X 8 24 0.097 1.5 35 1.5 0 35 S-Door-11 D 3 X 7 21 0.390 10.9 229 10.1 0 213 S -GIs-1A-cb-o shgc-0.75 0%S 6 1.080 30.2 181 34.0 0 204 UP-Ceil-I6F-30 12 X 8 96 0.032 0.9 86 0.5 - 0 46 Floor-22A-ph 9 ft..Per. 9 1.358 38.0 342 _ 0.0 _ 0 0 _^^ ` — _ Subtotals for Structure: 935 0 532 Infil.: Win.: 1.7, Sum.: 0.0 48 1.125 54 0.000 0 0 Ductwork: 257 253 People: 200 lat/per, 230 sen/per: 2 400 460 Room Totals: 1,246 400 1,245 C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac Residential & Light Commercial HVAC LbAdsz Elite Software Development, Inc. ResidentiaFEnergy C`alc's Morns Residence Port Saint Lucie, FL 34983 ` ' . .. _ :. = Pa� a 31 Detailed Room Loads - :Rooms-2-;Stairway (Average Load Pro"cedure).. General77 Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 17.0 ft. System Number: 1 Room Width: 4.0 ft. Zone Number: 1 Area: 68.0 sq.ft. Supply.Air: 23 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.6 AC/hr Volume: 544.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 7 CFM Runout Air: 23 CFM Percent of Supply.: 32 % Runout Duct Size: 0 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 7 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 8 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM Area , U , 4 °Htg , Senn 45 Clg Lat ; ;Seri: Description-, ; , .,� .. Quantity , Value,,, ,' Gain — Gain , E -Wall-13A-5fcs 4 X 8 32 0.105 2:9 94 1.6 0 51 S -Wall-13A-5fcs 11 X 8 88 0.105 2.9 259 1.6 0 141 W -Wall-13A-5fcs 14 X 8 112 0.105 2.9 329 1.6 0 180 UP-Ceil-16F-30 17 X 4 68 0.032 0.9 61 0.5 0 33 Floor-22A-ph 29 ft.. Per. _ _ _29 _1.358 __. 38_0 _ 1,103 0.0 0 _ 0 Subtotals for Structure: 1,846 0 405 Infil.: Win.: 8.4, Sum.: 0.0 232 1.116 259 0.000 0 0 Ductwork: 547 103 'Room Totals: 2,652 0 508 C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac Residential'& Light Commercial HVAC Loads Elite Software Development, Inc., Residential'Ehergy Calc's MomsR sidence Port;Saint Lucie, FL 34983' , ,•. .:,i,,.. ,. „ Pa a 32 ,Detailed,Room Loads = Roo' 'M .3, Z.Laundty .(Average'Load Procedure) .General, Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 8.0 ft. System Number: 1 Room Width: 4.0 ft. Zone Number: 1 Area:. 32.0 sq.ft. Supply Air: 67 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 15.8 AC/hr Volume: 256.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 67 CFM Percent of Supply.: 3 % Runout Duct Size: 0 in. Actual Summer Vent.: 5 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 7 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 2 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item , Via, �t L , r Area USend s spa ,; Clg Latx Sen . • ...• ` t 3 , Descnpbon;; ,.x . r P Quantit .Value'.HTM .Loss, - HTM.,r. a Gain W -Wall-13A-5fcs 8 X 8 64 0.105 2.9 188 1.6 0 103 UP-Ceil-16F-30 8 X 4 32 0.032 0.9 29 0.5 0 15 Floor-22A-ph 8 ft..Per. 8 1.358 38.0 304 0.0 0 0 Subtotals for Structure: 521 0 118 Infil.: Win.: 2.3, Sum.: 0.0 64 1.109 71 0.000 0 0 Ductwork: 154 301 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 0 600 Room Totals: 746 400 1,479 C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac Residenfiah& Light Gommerc�al HVAC Loads Ehte Software Development; Inc.? Resid`entiahEnergy Calc's �, Morns Re s�dence , •e:33 PortSont Lucie; FL 34983 ,', G F f, �.� - Pa -Detailed Room Loads- Ro6m-4-:.Bedroorn 3. (Average Load Procedure) aGeneral Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 15.0 ft. System Number: 1 Room Width: 11.0. ft. Zone Number: 1 Area: 165.0 sq.ft. Supply Air: 226 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 10.3 AC/hr Volume: 1,320.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 12 CFM Runout Air: 113 CFM Percent of Supply.: 5 % Runout Duct Size: 0 in. Actual Summer Vent.: 16 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 7 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 8 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item' Area-, -U- Htg ; Sen Clg , Lat'. Se . Description`, Quantit ,. Value ;` „ NTM Loss' HTM';, . , Gain' Gain W -Wall-13A-5fcs 15 X 8 105 0.105 2.9 309 1.6 0 169 N -Wall-12C-Osw 11 X 8 53 0.091 2.5 135 2.0 0 104 W -GIs-1A-cb-o shgc-0.75 0%S 15 1.080 ' 30.2 454 88.3 0 1,325 N -GIs-1A-cm-o shgc-0.75 100%S 35 1.270 35.6 1,244 34.9 0 1,220 (2) UP-Ceil-16F-30 15 X 11 165 0.032 0.9 148 0.5 0 79 Floor-22A-ph 26 ft.. Per. 26 1.358 38.0 989 0.0 0 0 Subtotals for Structure: 3,279 0 2,897 Infil.: Win.: 7.5, Sum.: 0.0 208 1.115 232 0.000 0 0 Ductwork: 912 1,011 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment_ 0 600 Room Totals: 4,423 400 t 4,968 C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac-- Residential & Light Commercial HVAC Loads Elite Software Development, Inc: Residential Energy Calc s _ Morris esidence Port Saint Lucie, FL ,34983 ;` w ,Pa a 3 Detailed Poo, Loads•- Room 5;.= 8edroom 2 (Average, Load Procedure): i ;General Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: 16.0 ft. System Number: 1 Room Width: 11.0 ft. Zone Number:: 1 Area- 176.0 sq.ft. Supply Air: 141 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 6.0 AC/hr Volume: 1,408.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual_ Winter, Vent.: 11 CFM Runout Air: 141 CFM' Percent of Supply.: 8 Runout Duct Size: 0 in. Actual Summer Vent.: 10. CFM. Runout Air Velocity: 0 ft./min. Percent of Supply: 7 Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 9 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM 1item: Area U `; Y Ht Sen „ '4, Clg b 1'Description= Lat ` Sen Gain Quantif` Value „' :HTM Loss, x HTM ; Gain N -Wall-I3A-5fcs 11 X 8. 58, 0.105 2.9 171 1.6 0 93 E -Wall-13A-5fcs 16 X 8 128 0.105 2.9 376 1.6 0 206 N -Wall-12C-Osw 4 X 8 32 0.091 2.5 82 2.0 0 63 N -GIs-1A-cb-o shgc-0.75 100%S 30 1.080 30.2 908 32.0 0 960 (2) UP-Ceil-16F-30 16 X 11 176 0.032 0.9 .158 0.5 0 84 Floor-22A-ph 31 ft.. Per. 31 1.358 38.0 1,179 0.,0 0 0 Subtotals for Structure: 2,874 0 1,406 Infil.:.Win.: 9.0, Sum.: 0.0 248 1.117 277 0.000 0 0 Ductwork: 818 630 People: 200 lat/per, 230 sen/per: 2 400 460 Equipment: 0 600 Room Totals: 3,969 400 3,096 C:\ ..:\Morris Residence.rh9 Thursday, October24, 2013, 9:06 AM Rhvac Residential 8< Light Commercial HVAC Loads Elite Software Development, lnc, Residential Energy Calc's 11,111-;P8rt18a'intiu'ciel, Mo�fis Residence �. FL '34983. `` "' Page 35 De. tailed .Room Loads - Room: 6 - lBath 1. (Average. Load Procedure) �.Gerieral ` ` Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 10.0 ft. System Number: 1 Room Width: 9.0 ft. Zone Number: 1 Area: 90.0 sq.ft. Supply Air: 67 CFM Ceiling Height: 8:0 ft. Supply Air Changes: 5.6 AC/hr Volume:. 720.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 67 CFM Percent of Supply.: 5 % Runout Duct Size: 0 in. Actual Summer Vent.: 5 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 7 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item' Area U Htg Ben , ,x La 9 , u, I ` Description r� Quantity ;Value:; HTM _ Loss `:HTM , Gain' Gain: E -Wall-13A-5fcs 9 X 8 63 0.105 2.9 185 1.6 0 101 E -GIs-1A-cb-o shgc-0.75 0%S 9 1.080 30.2 272 88.3 0 795 UP-Ceil-1617-30 10 X 9 90 0.032 0.9 81 0.5 0 43 Floor-22A-ph 9 ft..Per. 9 1.358 38.0 342 0.0 0 0 Subtotals for Structure: 880 0 939 Infil.: Win.: 2.6, Sum.: 0.0 72 1.111 80 0.000 0 0 Ductwork: 249 299 People: 200 lat/per, 230 sen/per: 1 200 230 Room Totals: 1,209 200 1,468 C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rlivac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc: Residential Energy Caic's _' ;. Morris Residence . Port Saint Lucie, FL 34983 Page 36•. Detailed Room Loads- Room: 7 = Master Bedroorn,(Alerage Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 2 Room Width: 11.0 ft. Zone Number: 2 Area: 143.0 sq.ft. Supply Air: 168 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 8.8 AC/hr Volume: 1,144.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 10 CFM Runout Air: 84 CFM Percent of Supply.: 6 % Runout Duct Size: 0 in. Actual Summer Vent.: 11 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 7 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 11 CFM Actual Loss: 0.000 in.wg./100 ft. Actual'Summer Infil.: 0 CFM Iitem " Area U besc"r' tion", Quanti Value,;' ,Htg `fix Sens Clg Lat ' Sen HTM..,' *,Loss, HTMr', Gain ;Gain, S -Wall-I3A-5fcs 6.5 X 8 37 0.105 2.9 109 1.6 0 59 S -Wall-12C-Osw 10 X 8 45 0.091 2.5 115 2.0 0 88 E -Wall-I3A-5fcs 13 X 8 89 0.105 2.9 262 1.6 0 143 .S -GIs-IA-cb-o shgc-0.6 0%S 15 0.590 16.5 248 23.1 0 346 E -GIs-IA-cb-o shgc-0.6 0%S 15 0.590 16.5 248 66.5 0 998 S -GIs-1A-cm-o shgc-0.6 0%S (2) 35 0.590 16.5 578 23.1 0 808 UP-Ceil-I6F-30 13 X 11 143 0.032 0.9 128 0.5 0 69 Floor-20P-30 11 X 13 143 0.035 1.0 140 0.4 0 50 Subtotals for Structure: 1,828 0 2,561 Infil.: Win.: 10.7, Sum.: 0.0 236 1.403 331 0.000 0 0 Ductwork: 816 664 People: 200 lat/per, 230 sen/per: 2 400 460 Room Totals: 2,975 400 3,685 C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac Residential -A. Light Commercial HVAC Loads Elite Software Development, Inc. Residential Energy Calcs .: ,. Morris Residence Port Saint' Lucie, FL 34983 ° ,� , . , , �I Pa a 37..' Detailed Room Loads - Room 8 --'.Walk In 'Closet. (Average Load Procedure) ,General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 8.0 . ft. System Number: 2 Room Width: 7.0 ft. Zone Number: 2 Area: 56.0 sq.ft. Supply Air: 11 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.5 AC/hr Volume: 448.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 11 CFM Percent of Supply.: 22 % Runout Duct Size: 0 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 7 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item J M Area ; , U Htg'Y Sen „� k Clg , Lat Sen � Descry > pion �Qntit ua HTM Gain': S -Wall-13A-5fcs 8 X 8 64 0.105 2.9 188 1.6 0 103 W -Wall-13A-5fcs 4 X 8 32 0.105 2.9 94 1.6 0 51 UP-Ceil-16F-30 8 X 7 56 0.032 0.9 50 0.5 0 27 Floor-20P-30 7 X 8 56 0.035 1.0 55 0.4 0 20 _ Subtotals for Structure: 387 0 201 Infil.: Win.: 4.4, Sum.: 0.0 96 1.396 134 0.000 0 0 Ductwork: 197 44 Room Totals: 718 0 245 C:\ ...\Morris Residence.rh9 Thursday, .October 24, 2013, 9:06 AM "vac Residential'& Ught Commercial HVAG Loads „ �, Elite Software,Development, Inc. ° Residential Energy Calc's :. Morris Residence' Porf Saint Lucie, FL 34983 Pa a 38 Detailed Room., Loads - Room ,9 .- Master. Bath ;(Average Load Procedure) ;:General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 2 Room Width: 7.0 ft. Zone Number: 2 Area: 91.0 sq.ft. Supply Air: 9 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 0.8 AC/hr Volume: 728.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 2 CFM Runout Air: 9 CFM Percent of Supply.: 21 % Runout Duct Size: 0 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 7 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item Area U 4,'Htg� ;� ^ Sen Clg Lat k Sen , z 4R hx pescnption, , ', , Quahtit' Value ;, HTM Loss „ Gam ; Gain E -Wall-13A-5fcs 7 X 8 56 0.105 2.9 165 1.6 0 90 UP-Ceil-16F-30 13 X 7 91 0.032 0.9 82 0.5 0 44 Floor-20P-30 7 X 13 91 0.035 1.0 89 0.4 0 32 Subtotals for Structure: 336 0 166 Infil.: Win.: 2.5, Sum.: 0.0 56 1.393 78 0.000 0 0 Ductwork: 156 36 Room Totals: 570 0 202 C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhi ac Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Residential Energy Calc's Morris,Residence' Saint Lucie. FL 34983 . ,.., Port Page 39 Detailed Room.Loads.= Room 1.0 - Kitchen (Average Load Procedure) General ` Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 21.0 ft. System Number: 2 Room Width: 8.0 ft. Zone Number: 2 Area: 168.0 sq.ft. Supply Air: 194 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 8.7 AC/hr Volume: 1,344.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 6 CFM Runout Air: 97 CFM Percent of Supply.: 3 % Runout Duct Size: 0 in. Actual Summer Vent.: 13 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 7 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.000 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item; Area , } , U i Htg Seq �1 CIg Lat t „ Sen; Descn tion ; alue"",Gain:, Qtfuaniy ,V,, Gain E -Wall-13A-5fcs 8 X 8 46 0.105 2.9 135 1.6 0 74 W -Wall-13A-5fcs 8 X 8 52 0.105 2.9 153 1.6 , 0 84 E -GIs-1A-cb-o shgc-0.6 0%S 18 0.590 16.5 297 66:6 0 1,198 W -GIs-1A-cb-o shgc-0.6 0%S 12 0.590 16.5 198 66.6 0 799 UP-Ceil-16F-30 21 X 8 168 0.032 0.9 151 0.5 0 81 Floor-20P-30 8 X 21 168 0.035 1.0 165 0.4 0 59 Subtotals for Structure: 1,099 0 2,295 Infil.: Win.: 5.8,.Sum.: 0.0 128 1.398 179 0.000 0 0 Ductwork: 483 768 Equipment: 600 1,200 Room Totals: 1,761 600 4,263 C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac Residential & Light Commercial HVAC Loads ""y Elite Software Development, Inc., Residential t - Calc's Morris Residence by Port'Saint Lucie, FL- 34983 Page 40 Detailed Room. Loads, - Room, I I =- Living --(Average, Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 21.0 ft. System Number: 2 Room Width: 9.5 ft. Zone Number: 2 Area: 200.0 sq.ft. Supply Air: 167 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 6.3 'AC/hr Volume: 1,566.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 16 CFM Runout Air: 84 CFM Percent of Supply.: 10 % Runout Duct Size: 0 in. Actual Summer Vent.:. 11 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 7 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 15 CFM Actual Loss: 0.000 in.wg./l00 ft. Actual Summer Infil.: 0 CFM Item: - a Area U ; Htg sen Clg At, Sen Description Quanti x Value ,: , . HT M ', . N .Loss HTM . Gain Gain E -Wall-13A-5fcs 9.5 X 8 76 0.105.. 2.9 223 1.6 0 122 N-Wa11712C-Osw 21 X 8 52.5 0.091 2.5 134 2.0 0 103 W -Wall-13A-5fcs 11 X 8 88 0.105 2.9 259 1.6 0 141 N -GIs-1A-cm-o shgc-0.6 100%S (2) 49 0.590 16.5 810 21.5 0 1,052 N -GIs-1A-cm-o shgc-0.6 100%S (2) 56 0.590 16.5 926 21.5 0 1,204 N-GIs-IA-cm-o shgc-0.6 100%S 10.5 0.590 16.5 173 21.5 0 226 UP-Ceil-1617-30 21 X 9.5 199.5 0.032 0.9 179 0.5 0 96 Floor-20P-30 9.5 X 21 . 199.5 0.035 1.0 196 0.4 0 70 Subtotals for Structure: 2,900 .0 3,014 Infil.: Win.: 15.1, Sum.: 0.0 332 1.401 -465 0.000 0 0 Ductwork: 1,272 662 Equipment: 300 0. Room Totals: 4,637 300 3,676 C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013; 9:06 AM Rhvac Residential &Light Commercial HYA_C Loads Elite Software Development, Inc. Residential Energy Calc's Morns Residence` ;.. Port Saint L' ucie, FL` 34983 , s Pa a 41 Detailed, Room -Loads. -,Room 12,-.Stair (Average Load Procedure) General 1 Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 16.1 ft. System Number: 2 Room Width: 4.0 ft. Zone=Number: 2 Area: 64.0 sq.ft. Supply Air: 44 CFM Ceiling. Height: 8.0 ft. Supply Air Changes: 5.1 AC/hr Volume: 515.0 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 44 CFM Percent of Supply.: 7 % Runout Duct Size: 0 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 7 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.000 in.wg./l00 ft. Actual Summer Infil.: 0 CFM Item' Area , U Ht';Sen CI s h 9 9 M F i r I.Ppscription.:: Lat Sen F h,$ i , ., . , ;`, , =.Quariti Value,; , . t ,HTM n .::.Loss HTM ; =Gam ": Gain W -Wall-13A-5fcs 12 X 8 87 0.105 2.9 256 1.6 0 140 W -GIs-lA-cb-o shgc-0.6 0%S 9 0.590 16.5 149 66.6 0 599 UP-Ceil-16F-30 16.1 X 4 64.4 0.032 0.9 58 0.5 0 31 Floor-20P-30 4 X 16.1 64.4 0.035 1.0 63 0.4 0 23 Subtotals'for Structure: 526 0 793 Infil.: Win.: 4.4, Sum.: 0.0 96 1.396 134 0.000 0 0 Ductwork: 249 174 Room Totals: 909 0 967 C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac.-Residential & Light Commercial HVAC Loads : ", _ ` , , Elite Software Development, Inc.' Residential_Energy Calcs Morris Re sidence Port Saint Lucie, FL' 34983 Pa a 46 System 1. Room Load Summary Htg Mm Run Run Clg Clg in Act Room Area Sens Htg Duct Duct Sens: ' Lat , Clg Sys No'Name, i:� . _.. _ . '`'SF Btuh` CFM Size', Yel. Btuti�;; Btuh -; ` : CFM _CFM`. ---Zone 1--- 1 Foyer 96 1,246 16 1-0 0 1,245 400 57 57' 2 Stairway 68 2,652 34 1-0 0 508 0 23 23 3 Laundry 32 746 10 1-0 0 1,479 400 67 6 4 Bedroom 3 165 4,423 57 2-0 0 4,968 400 226 226 5 Bedroom 2 176 3,969 52 1-0 0 '3,096 400 141 141 6 Bath 1 90 1,209 16 1-0 0 1,468 200 67 67 Ventilation 1,231 659 1,660 Duct Latent 760 _ System 1 total 627 15,475 185 _ 13,424 4,220 581 581 System 1 Main Trunk Size: OxO in. Velocity: 0 ft./min Loss per 100 ft.: 0.000 in.wg Coming, S stem "Summa . ` Cooling Sensible/Latent,. Sensible ..; f Latent Total Tons `' Split . ` Btuh , Btuh Btuh . Net Required: 1.47 76% / 24% 13,424 4,220 17,644 Actual: 1.58 76%./ 24% 14,400 4,600 19,000 Equipment Data Heating System Cooling System Type: Electric Resistance Standard Air Conditioner Model: 14AJM19 14AJM19 Indoor Model: RHKL-HM2417 Brand: Rheem 14AJM Series RHEEM 14AJM SERIES Description: 5KW CENTRAL AIR 16 SEER Efficiency: 0 0 Comment: 0 Sound: 0 0 Capacity: 19000 19000 Sensible Capacity: n/a 14,400 Btuh Latent Capacity: n/a _ 4,600 Btuh AHRI Reference No.: n/a 5550185 . V C:\ ...\Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM Rhvac Residential &Light Commercial HVAC Loads k 3, tine Sortware ueveiopment, mc. Residential Energy Calc's Morris Residencec PoifSaint Lucie FL .34983 Bade 47 System- 2':RoornIoad Summary ---zone 2-- 7 Master Bedroom 143 2,975 39 2-0 0 3,685 400 168 168E 8 Walk In Closet 56 718 9 1-0 0 245 0 11 11'' 9 Master Bath 91 570 7 1-0 0 202 0 9 9w 10 Kitchen 168 1,761 23 2-0 0 4,263 600 194 194 11 Living 200 4,637 60 2-0 0 3,676 300 167 167" 12 Stairway 64 909 12 1-0 0 967 0 44 44 t Ventilation 1,231 659 1,660 _Duct Latent 878 System 2 total 722 12,801 150 13,699 3,838 593 593 System 2'Main Trunk Size: Ox0 in. Velocity:. _ 0 ft./min Loss per 100 ft.: 0.000 in.wg Cooling S stem:Surnma ' Actual: 1.58 76% / 24% 14,400 4,600 19,000 Heating System Coolinq System Type: Electric Resistance Standard Air Conditioner Model: 14AJM19 RHKL=HM2417 Indoor Model: 14AJM19 Brand: RHEEM SERIES 14AJM SERIES Description: 5KW CENTRAL UNIT 16 SEER Efficiency: 0 Q. Comment: 0 Sound: 0 0 Capacity: 19000 19000 Sensible Capacity: n/a 14,400 Btuh Latent Capacity: n/a 4,600 Btuh AHRI Reference No.:. n/a 5550185 CQX� C:1... \Morris Residence.rh9 Thursday, October 24, 2013, 9:06 AM