HomeMy WebLinkAboutInspection Cardk-
..
Inspection Card
PlanningA Development 5ervlces
Permit # : 1401-0220
Online address:
Building &.Code.Regulation D(vlsion
http://www.stlucieco.org/planning/permitting.htm
23i}0 Virginia Avenge:
Quick Links:
FortPierce,•FL. 34982
Phone:(772)462 2172: Fax (772)462-6443
Permit Status Lookup
Online Building Inspection System
Permit#
Issued:
Job Location:
Jurisdiction:
Subdivision:
Flood:
Set backs:
Job Description
Contractor
Property Owner
Property Owner
SLC-1401-0220 #Confirmation 833 Status ISS
1/28/2014 Type: BUILDING (MISCELLANEOUS)
8232 S Ocean Dr City: Jensen Beach
SAINT LUCIE COUNTY Parcel: 3527-501-0038-000/0
DIAMOND SANDS PLAT 2 Lot: 37 Block:
AE Elev: Flood Map: 303G
Left:7.57 Right: 7.50 Front:21.26 Rear: 18.00
Installation Of Pilings And Grade Beams For A Single Family Residence Permit 1310-0077. (Rear Setback To
Easement)*** Contractor Revised Scope Of Work On This Permit To Include Constructing Stemwalls, Plumbing
Rough And Pour Slab * No Vertical Work Will Be Performed Under This Permit **
Mario P Arbucci -- Cert # 27063
3462 Se Dixie Hwy
Peter F Apanovitch
% Christopher Twohey, Pa
Virginia B Apanovitch
Christopher Twohey, Pa
Oceanfront Builders Of The Treasure Coast Llc (772) 219-2180
Stuart, FL 34997
(305) 745-2762
Stuart, FL 34984
Stuart, FL 34984
(305) 745-2762
SUB -PERMITS
Permit No Status Permit Tvue Cert # DBA Owner/Builder Job Desc.
1401-0220-01 Pending PLUMBING - 27366 Masters Plumbing Inc Of Martin.
RESIDENTIAL County
For the automated inspection system call (866) 284-1280. To schedule an inspection online go to
http://codeinspectionpublic.stiucieco.gov. All inspections requested prior to 9:00 PM will be scheduled for the next business
day. Inspection requests between 9:00 PM Friday and 9:00 PM Monday will be scheduled for the following Tuesday. If you
require any assistance please contact the Building Department at (772) 462-2172.
Inspection Notes: 1-16-2014 CONTRACTOR WILL NEED ENGINEERING REPORTS ON PILINGS- REPORT HAVE TO BE
DONE BEFORE HOUSE PERMIT CAN BE ISSUED- A HUMPHREY *** ALL PILING AND GRADE BEAM
INSPECTIONS ARE TO BE PERFORMED BY ROBERT AGSTEN P.E.# 43205 AND RAISED SEAL REPORTS
SUBMITTED TO THIS OFFICE FOR FILING PRIOR TO FINAL INSPECTIONS * JMC
Permit # Code Description Prialft Sched. Date Res Description Inspector Insp. Date
1401-0220 103 EUFER GROUND 1 3/18/2014 90 Approved Gary Scheigner 3/1812014
COMPACTION TEST -
1401-0220 104 ORIGINAL - TURN INTO 1
OFFICE
ENGINEERS REPORT- Accepted as
1401-0220 106 ORIGINAL -TURN INTO 1 2/21/2014 92 noted Private Provider 2/21/2014
OFFICE
NEED ENGINEERS REPORT FOR THE PILING INSTALLATION AND THE GRADE BEAM INSTALLATION PER THE ENGINEERS PLANS BYAGSTEN
ENGINEERING PE#43205 * CONTRACTOR USED DONALD MOLER P.E.# 60675 OF GFA INTERNATIONAL
Report prepared on 4/2/2014 1:27:13 PM
,
Inspection Card
Planning& Development Serv►c s
Permit # : 14
Online address:
Building & Code Regulatlon Division
http://ww�nrstlucieco.org/planning/permitting.htm
23l}O Virgihia Avenge
Quick Links:
Fort Pierce, FL 34982
Permit Status Lookup
Phone:(772)462.2172 'Fax:(772)4824443
Online Building Inspection System
ENGINEERS REPORT-
Engineer,
1401-0220 106 ORIGINAL -TURN INTO
1 3/12/2014 50 Approval Joe Cicio 3/12/2014
OFFICE
Accepted
SUBMIT AN ORIGINAL SIGNED, SEALED AND DATED LETTER FROM AGSTEN ENGINEERING FOR THE ELIMINATION OR EXPLAINATION OF
NOTE 11 ON SHEET S-5 ** RE -SUBMITTED PLANS FROM ROBERT AGSTEN P.E. HAS NOTE #11 AND #18 REMOVED FROM THE REVISED
PLANS * JMC
ENGINEERS REPORT-
Engineer
1401-0220 106 ORIGINAL -TURN INTO
1 3/13/2014 50 Approval Private Provider 3/13/2014
OFFICE
Accepted
NEED ENGINEERS REPORT FOR THE GRADE BEAMS IF COMPLETED ON THIS PERMIT * RECEIVED REPORT FROM GFA 03/13/2014
ENGINEERS REPORT-
1401-0220 106 ORIGINAL -TURN INTO
1 3/17/2014 91 Partial Approval Joe Cicio 3/17/2014
OFFICE
NEED ORIGINAL S.S.D BREAK REPORTS FROM GFA / E-MAILS SUBMITTED 03/14/2014 * JMC
ENGINEERS REPORT-
1401-0220 106 ORIGINAL -TURN INTO
1
OFFICE
AGAIN FAXED COPIES SUBMITTED * NEED ORIGINAL
CONCRETE BREAK REPORTS FROM GFA INTERN. * JMC
1401-0220 119 STEM WALL
1 3/18/2014 90 Approved Gary Scheigner 3/18/2014
1401-0220 129 PILE CAP
1 2/21/2014 92 Accepted as Private Provider 2/21/2014
noted
INSPECTION COMPLETED BY DONALD MOLER OF GFA INTERNATIONAL
1401-0220 232 UNDERGROUND
1
ELECTRIC
1401-0220 420 PLUMBING ROUGH
1 3/25/2014
90 Approved GaryScheigner 3/25/2014
UNDERGROUND
BATCH TICKETS
1401-0220 906 (CONCRETE) - TURN
1 3/11/2014
90 Approved Deanna Givens 3/11/2014
INTO OFFICE
COMPRESSIVE STRENGTH FOR PILING CONCRETE 5,000 PSI * RECEIVED THE
PROPER REPORTS 03/14/2014 * JMC
BATCH TICKETS
Accepted as
1401-0220 906 (CONCRETE) - TURN
1 3/14/2014
92 noted Joe Cicio 3/14/2014
INTO OFFICE
GRADE BEAMS ARE 4,000 PSI
1401=0220 115 SLAB
2
1401-0220 121 TERMITE SPRAY
2
BATCH TICKETS
1401-0220 906 (CONCRETE) - TURN
2
INTO OFFICE
ALL FOUNDATION CONCRETE TO BE 4,000 P.S.I.
1401-0220 999 FINAL INSPECTION
3
Total Inspections:
17
0
Report prepared on 4/2/2014 1:27:13 PM