Y -- wrightsoft® Project Sulrnllnalry DatJoe: Enure House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT PIERCE, FL 34946 For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: —Design In• • Weather Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 . OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 %. Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18467 Btuh Structure 17655 Btuh Ducts 6190 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none e) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Use manufacturer's data n Rate/swing multi tier 0.95 Infiltration Equipmenf sensible load 25645 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh Area Heating Coolin�gg (none) 'Equipment (ft2) 1753 1753 latent load 5007 Btuh Volume (ft3) 14741 14741 Air changes/hour 0.38 0.20 Equipment total load 30652 Btuh Equiv. (cfm) 93 49 Req. total capacity at.0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 27 °F 1160 cfm 0.047. cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15-SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total coolin 34800, Btuh Actual air flog. w 1160 cfm Air flow factor 0.043 cfm/Bfuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. " wrightsoft` 2017 Apr-10 17:19:28 14CCA Right-Suitee Universal 201717.0.14 RSU08101 Page 1 ...k CalcslDocuments%WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front.Doorfaces: N ' -- wrightsoft Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name Entire House MASTER BEDROOM 2 E)(posed wall 163.0 ft 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4 5 Room dimensions Room area 1753.0 ft2 1.0 x 280.0 ft 280.0 ft2 Ty Construction number U-value (Btuh/ft2m°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 A4 13AAbes 1A c1om ' 1Aclom :. ;1A-c1om •: 13AAocs 0.143 1:270 1.270 1:270 0.143 ne...4.00., rie :. ne . ne . se 35 56 3556 35.56 4.00 2.55 . 7043 7043 • 45.24. 2.55 488 7 16 16 64 448 0 0 p 41 179.5 347 581 581 165 1141 488 1151 .. _ 739 105 192 0 0 p 0 192 ' 0 0: 0 0 769 ; 0 0 p 0 489 :,0 0' 0. 0 T—D 11D0 13A-0oi " ` ;4A52om' .. 0.390 0.143 0:770' se sw., 10.92 " "4:00 21.56 11.31 255 (:• 27:53' 23 ' i437 41 ,- - 23 .396 45 20 ' :15M 893.= 257 1007, 1140 0 `. 56 .• `.. 0 0 : 56 • . 0' 0 ; 224 0. 0 . 143 - 0 V�J 13AAocs 1A-clom 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 290 33 217 0 867 1162 551 1478 112 33 79 0 318 1162 202 1478 4A5�29md :12C-0sw• 16A30md 0.770 0.091 0.032 nw '.- - 21.56 . 2:55 0.90 36.90 + 128 2.32 41 : 308 1753 0 .308 1753 880 `' :784' 1571 1505 •-395 409 0 .:. ;0 280 0 :- " 0 280 0 . 0 251 0 . 0 650 .P . '; C 'F ', ; ; 22A-tpl : W. 0:989 - :. _ 27A 0:00 1753 153 4237 '' 0 280 . 45 1246 - 0 6 c)AED erxursion 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 a) infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Interne! gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 0 Subtotal (lines 6 to 13) 18467 17655 4779 3789 Less a demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal' 18467 17655 4779 3789 15 Duct loads 34% 53%1 6190 9340 34% 53%1 1602 2005 7 Total room load 24657 269951 1 6380 5794 Air required (cfm) 1160 11601 1 300 249 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. c 4j4- wrightsoft• 2017-Apr-10 17:19:28 . COCA Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJB Front Door faces: N - - wrightsoft° RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name WIC M. BATH 2 Exposed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 ft2 1.0 x 61.0 ft 61.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ftq Load number (Btuh/ftk-'F) (Btuhlftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A-0ocs . 0.143 ne 4.00 2.55 0 0 0 0 56 49 '196 125 -91om : 1A-c1om .. 1Ac1om . 1,270 1.270 1.270 he,: ne- ;ne 35.56 3556 35.56 70:43 70:43' 45 24 0 .0 .0'. 0 0,-.., 0.'. 0 0 0 0 0'.: -0 7 0 0 ''0. 0 6, 247 ; p 0 488 .0 0 W L-D 11 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11D0 13A-0ocs: ;4A5 tom 0.390 0;143 0:770 se sw ° sw.= 10.92 4:00' 21:56; 11.31 2 55 27 53 0 :0 ' - 0 0 , . 0 0 0 0 "0.- 0,- ', 0 0 0 0 .0 0 0 0 0 . . 0 ` _0 0 0 D ViJ 13AAocs 0:143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 ll-_GG p ?.:12C0sw= 4A572omd ,., 0.770 b:091'.:'- , nw 21.56 `255,'. 36.90 -1:28`. 0 _ 0 0 Or 0 .'• 0: 0 0 0 0 0. :0 0 ... 0 0 0 C 16A-30md 0.032 - 0.90 2.32 63 63 56 146 61 61 55 142 F A. 22A-tpl ` 6.M9 - 27.691 -" 0.'06 63 A -0 `• 0 - . '61 . , 7 194 0 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 56 141 817 764 Less a)demal load 0 0 0 0 Less transfer 0 0 0 0 14 15 Redistribution Subtotal Duct loads 34% 53%1 0 56 19 0 141 75 . MIA 53% 0 817 274 0 764 404 Total room load 75 216 1091 1168 Air required (cfm) 4 9 51 50 Calculations - wrightsoit' Right -Suite® Universal 201717.0.14 RSU08101 ... k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: J 8th Ed. 2017-Apr-10 17:19:28 Page 2 - - wrightsoft- Right,J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email:.QUICKCALCS a( AOL.COM 1 Room name LAUDRY BEDROOM 2 2 3 E)posed wall Room height 0 ft 8.0 ft heat/cool 12.0 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 ft2 15.0 x 12.0 ft 180.0 ft2 Ty Construction number U-value (Btuh/ft2�-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1Ac1oms 1.270 ne he~ 35 5�6 . 2.55. ; 70.43 70.43 0 ., 0 - 0 0 0, :. 0 0 U 0 0 0 0 96 .. 0 16 80 : 0 :: 0 . 319 0 . 561 203, 0 1151 11 1A�1orn: 13A-tocs 1.270 0.143 ne se 35.56. 4.00 ' 45:24 255 - 0 0 0 0 , 0 0 0 0 0 0 0 0 :.. 0 0 . 0 0 ... 1N 11DO 13A4ocs: ' .. • i4A5 tom ' ' 0.390 0.143 0:770 se sw :sw 10.92 4;00. 2156, 11.31 2.55 27 53 0 . 0 "- 0 0 0 0 0 - 0 0 0 0 0 0 `0 .. 0. 0 •10 .0 0 ,.. 0.. 0 0 0 :. A yJ L—G 13AAocs 1Aclom 4A5-2omd ;12G0sw 16A-30md 22A4pl . 0.143 1.270 0.770 ,0:091 0.0.32 0:989 nw nw nw '.= : - -. 4.00 35.56 21.56 , . ' 2: 5 0.90 `• ..27.69 2.55 45.24 36.90 ` -.1.28 2.32 ' 0.00 0 0 0 0 36 •. 36 0 0 0 0 36 0 0 0 0 0 32 0 0 0 0 0 84 A- 0 0 0 _ '0 180 - . 180 0 0 0 -. ' ..' 0 180 . 12 0 0 0 ,:. .. (Y 161 332 0 0 0 p, 418 : : ' 0 P . ; C F 6 c)AED emursion -3 30 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliancestother 0 0 Subtotal (lines 6 to 13) 32 811 1609 1772 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 34% 53%1 13 50 340/0 53% 541 945 Total room load 51 145 2156 2730 -Air required (cfm) 21 6 101 117 Calculations approved bYACCA to meet all requirements of Manual J 8th Ed. wrightsoft• 2017-Apr-10 1 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 3 k Calcs%Documents%WYNNE-THE WINDSOR-REVISED.rup Calc = MJBFront Door faces: N - - wriohtsoft' Right,J® Worksheet Job: Entire House Date: QUICK CALLS, INC. By- 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email:, OUICKCALCS AOL.COM 1 Room name DINING/GREAT ROOM KITCHEN 2 E)q)osed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 5 Room dimensions Room area 1.0 x 588.0 ft 588.0 ft2 19.0 x 11.0 ft 209.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft? °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Y)/ 13A flocs 1A-olbm 0.143 1:270 ne ne . 4 00 , 35 56 2.55 70 43 . 0 0 0 0 0 0 0 0 0 . 0 0 1 0 0 0 0 0 1Ac1om 1270 _he 3556' 7043 ` .: 0 ' 0 -.- 0 0 _ . 0 0 0 0 �I--CGG W 11 7Ac.1om 13A�4ocs 1.270. 0.143 ne.. se , 35,56 4.00 ` 45:24 Z55 0 0 0. 0 p 0 .. p 0 p 0 0: 0 A p 0 11DO -9A5' tom. 0.390 0:143 0 770 se, sw; sw. 1092 4 00' . 21 56 _ 11.31 2 55 ;: 27.53 .0 267 .. 41 0 226 - 22 0 . 903 893 0 :.. 574 1140 0 : 98 0 0 : 98 0 .0 0 . 392 = 0 0 249 0 L—D �13A�oes. . V)1 13A-4ocs 0.143 nw 4.00 Z65 178 137 549 349 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5.2omd a12C-0sw 0.770 -0 091 nw 21.56. ' 2:55 . 36.90 ' -.1:28 41 ' '0 0 0 880 " 0 1505 0 0 = 116 0 .: 116 0 ".. 295 0 148 P <: C 16A-30md 0.032 0.90 2.32 588 588 527 1364 209 209 187 485 F= , %-' ;22A='tpl. " ' 0:989 - : . 27.0 0.00. 668 56 ' 1385 " 0 209 .. 11, 305 - 0 6 c)AED eursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a)Infiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 1000 Subtotal (lines 6 to 13) 6136 6679 1399 1880 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 53% 2058 3541 34% 53% 469 go Total room load 8200 10234 1861 2875 Air required (cfm) 386 440 88 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk wcightsofY 2017-Apr-10 1 Right -Suite@ Universal 2017 17.0.14 RSU08101 Page 4 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup' Calc = MJ8 Front Door faces: N -�+ wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/\OL.COM 1 Room name BATH HALL 2 Exposed wall 5.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 5.0 ft 50.0 ft2 5.0 x 5.0 ft 25.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft2) Load number (Btuh/W�- °F) (Btuh(ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 13A-4ocs 1Ac1om 1Ac1om 1Ac1om= 0.143 1.270 15270 1:270 ne ne ne .: ..,ne 4 00 3556 3556 35.56 2.55 7043 7043' = .45.24 40 0 :0 0 . 40 0; '. 0- 0 160 0 -0 0 102 A p .. .6.: 0 0 0 0 0 0 - 0 ` 0: 0 0 ;,.. 0 0 0 .0 0' '. `0 L--D, 11 13AAocs 0A43 se 4.00 2.55 0 0 0 0 0 0 0 0 11.DO 13A4ocs . .4A5tom< .' 0.390 .0143 .0.770 se sw - :sw 10.92 4 00 21.5fi 11.31 2 55 n 27.53 0 ., : .: , 0 0 0 p 0 0 .: „ 0 0. 0 _ . p 0: 0 .. 0 0.. 0 . 0 0 0.:' 0 0 0 VI! 13A4ocs 1Aclom 0.143 1.270 nw nw 4.00 35.56 2.65 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5.2omd, ' 12C-0sw' . 0,770 0:091 nw =' 21.55 2.55' 36.90 .1.28 0 . 0 0_ .0 0 . 0 0 ` ...0 0 0 0. ' 0 0 0 0 0 : P:': :' C 16A-30md 0.032 - 0.90 Z32 50 50 45 116 25 25 22 58 F' j22lktpl 0:989 . - . .... 2T89 0:00 : : 50 . 5 138 : : 0 _ 125 :0 0 0. 6 c)AED excursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 433 235 22 56 i Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 15 Duct loads 34% 53% 147 132 34°/u 53% 0 0 Total room load 586 .3811 0 0 Air required (cfm) 1 28 16 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A -Fp- wrightsoft' 2017-Apr-10 17:19:28 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 .:k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8' Front Door faces: N - wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST LUCIE•LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email; QUICKCALCS AOL.COM 1 Room name FOYER BEDROOM-3 2 Eposed wall 9.0 ft . 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 920 ft 92.0 ft2 13.0 x 13.0 ft 169.0 ft2 Ty Construction number U-value (Btuh/ft-°F) Or HTM (Btuh/ftz) Area (ft2) or perimeter (ft) Load (Btuh) Area -) or perimeter (ft) Load (13th) Heat Cool Gross N/P/S Heat Cool Gross WKS Heat Cool 6 13A4ocs 1Aclom 1Ac1om :` 0.143 1.270 1;270 ; no ne ne:, .4.00, 3556 3556; 2.65 7043. 7043. 0 0 0 0 0 0 0 0 0 0 0. -' 0. 104 0` 0 88 0,.010 .. 0 351 0 223 0 1A c1om 1:270 ne 35.56 . 45.24 0 . 0 • • 0 0 16' 0;, 561 Vy L-D 11 13AAocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 11DO 13A flocs 0.390 0;143 0770 se sw . sw.. 1092 ": 4 00 2t56' 1131 , s 2 55 27.53 23 . 8 ' ;o 23 ., 8 `. 0 248 32 . - 0 257 . • .. .20 0 0 ::. 8 :0 0 8 .. o 0 : 32 o: 0 :' 20 o 13A4ocs 1A-c1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5.2omd 12C-0sw;`. 16A30md ^22A-tpl 0.770 .0.091' 0.632 0.989 nw - .::- 21.56 2 5.5 0.90 27.69 36.90 1628 Z32 ,. 0.00 0 - - 88 92 92 0 88 92 9' 0 224 82 249:' 0 ; 113 213 0. 0 ' 104 169 .169. 0 `. 104, 169 ..14.. 0 . 265 151 ,: "388.% 0 ` 133' 392 0 P C iF • . 6 c)AED ecursion -25 -52 Envelope loss/gain 1002 684 1768 1456 12 a) infiltration 162 46 252 71 b) 'Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 11631 730 2020 1527 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 1527 15 Duct loads 340/c 53% 390 386 34% 53% 677 808 11 Total room load 1553 1116 2697 2335 Air required (cfm) 73 48 127 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk wrigotsoft- 2017-Apr-1017:19:28 A RightSuite@ Universal 2017 17.0.14 RSU08101 Page 6 k Calcs\DocumentslWYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N -+- wrightsoft° Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 7.72-466-6799 Fa)c 772466-6796 Email:, QUICKCALCS@AOL.COM For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Job: Date: 13,: Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O. 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.273 in/100ft 0.273 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length (TEL) 183 ft SupplyDetail Table Name Design (Btuh) Htg (cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox0 VIFx 19.5 115.6 st1 BEDROOM 2 C 2730 101 117 0.384 7.0 Ox 0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 Ox0 VIFx 26.8 115.0 st1 DINING/GREAT ROOM c 3411 129 147 0.292 7.0 Ox 0 VIFx 36.5 135.0 st2 DINING/GREAT ROOM-B C 3411 129 147 0.371 7.0 ox0 VIFx _ 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 OxO VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox 0 VIFx 7:0 95.0 KITCHEN C 2875 88 124 0:366 6.0 Ox0 VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 Ox 0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 Ox0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 Ox0 VIFx 40.9 135.0 st2 WIC c 216 4 9 0.292 4.0 OxO VIFx 36.0 135.0 st2 Supply Trunk Detail Table Trunk . Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx wrightsoft- Right -Suite® Universal 2017 17.0.14 RSUD8101 2017-Apr-10 17:1ge 1 ZiCA Page 1 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) . TEL (ft). Design FR Veloc ftm) Diam (in) H x W (in) Stud/Joist Opening (in) . Duct Matl' Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx WI'1 htsoft° 2017-Apr-1017:1g:2s ��� " 1� 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ..kCalcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N