Loading...
HomeMy WebLinkAboutDESIGN PRESSURE REPORT Property Information Building Information Owner: ANDREW&NATALIE BOULAY Wind Zone: 160 MPH. Address: 7003 CITRUS PARK BLVD Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 50 ft. Mean Roof Height: 20 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 36 49.25 7 35.1 -38.1 2 End 36 49.25 7 35.1 -46.7 3 End 52 37.25 7 34.9 -46.3 4 End 52 37.25 7 34.9 -46.3 5 End 36 49.25 7 35.1 -46.7 6 Int 25.25 24.5 7 35.6 -38.6 7 End 47 47 7 34.6 -45.6 8 End 47 47 7 34.6 -45.6 9 End 47 47 7 34.6 -45.6 10 Int 47 47 7 34.6 -37.6 11 Int 52 49.5 7 34.2 -37.2 12 End 52 25 7 35.6 -47.6 Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code. Page I of I