HomeMy WebLinkAboutAPPROVED-8.4kwSHEET NAMEPROJECT NAME & ADDRESS5810 TANGELO DR FORT PIERCE, FL 34982 ANDREW FUNSTON RESIDENCE Ph.#: (772) 501-7021 Email: andrewscottfunston@gmail.comREVDATEDESCRIPTIONREVISIONS ATLANTIC KEY ENERGY LLC+1 (407) 988-02737006 STAPOINT CTSTE BWINTER PARK, FL 32792Drawn by:N.R.Checked by:Date:2/23/22Sheet size:ANSI B 11" X 17"Scale:AS SHOWNSHEET NUMBERCS-0SIGNATURE WITH SEALO.T.SCOPE OF WORK:TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM ATTHE OWNER RESIDENCE LOCATED AT 5810 TANGELO DR, FORTPIERCE, FL 34982.SYSTEM DC RATING: 8.40 KWDCSYSTEM AC RATING: 6.10 KWACGENERAL NOTES:·THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELDINSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME.ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS INCONSTRUCTION DETAILS.·ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANYCONSTRUCTION OR INSTALLATION OF ANY EQUIPMENT AT SITE.·CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK ANDVERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. ANYDISCREPANCIES SHALL BE REPORTED TO THE ENGINEER BEFOREPROCEEDING WITH THE WORK. ANY WORK STARTED BEFORECONSULTATION AND ACCEPTANCE BY THE ENGINEER SHALL BE THESOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BESUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONALCOMPENSATION.·THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPERINSTALLATION AND COMPLETION OF THE WORK WITH APPROVEDMATERIALS.·THE CONTRACTOR SHALL PERFORM THE WORK IN STRICTCONFORMANCE WITH THE LOCAL LAWS, REGULATIONS AND THENATIONAL ELECTRIC CODE.ELECTRICAL NOTES:·THE EQUIPMENT AND ALL ASSOCIATED WIRING ANDINTERCONNECTION SHALL BE INSTALLED ONLY BY QUALIFIEDPEOPLE. A QUALIFIED PERSON IS ONE WHO HAS SKILLS ANDKNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OFTHE ELECTRICAL EQUIPMENT AND INSTALLATIONS AND HASRECEIVED SAFETY TRAINING TO RECOGNIZE AND AVOID THEHAZARDS INVOLVED. (NEC 690.4(C), NEC 2017).·NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC.SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONSAND THE COORDINATION REQUIREMENTS OF OTHER TRADES.·ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TOQUALIFIED PERSONNEL.·ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARELISTED AS UV RESISTANT.·ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITSPURPOSE AND APPROVED FOR THE SITE APPLICATIONS.PANEL LAYOUTCOVER SHEET &BOMPRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEAL, AND ALL SHA-1 AUTHENTICATION CODEMUST BE VERIFIED ON ANY ELECTRONIC COPIES.SHEET INDEXCS-0COVER SHEET & BOME-1STRING LAYOUT & SIGNAGEE-2ELECT. DIAGRAM & CALCS.E-3+EQUIPMENT SPECIFICATIONSBILL OF MATERIALSEQUIPMENT QTYDESCRIPTIONSOLAR PV MODULE21Q.PEAK DUO BLK ML-G10+ 400WMICROINVERTER21ENPHASE IQ7PLUS-72-2-USJUNCTION BOX1JUNCTION BOX, NEMA 3R, UL LISTEDCOMBINER BOX1ENPHASE IQ COMBINER 3 W/ IQ ENVOY (X-IQ-AM1-240-3)AC DISCONNECT1NON-FUSED AC DISCONNECT, 240V, NEMA 3R, UL LISTEDGOVERNING CODES2018 NFPA 1 (FIRE CODE)2017 NATIONAL ELECTRICAL CODE2020 FLORIDA BUILDING CODE (7TH EDITION)AUTHORITY HAVING JURISDICTION (AHJ): CITY OF DEBARY 18" FIRE SETBACK1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 36" FIRE SETBACK 1 8 " F I R E S E T B A C K 18" FIRE SETBA C K 18" FIRE SETBACK18" FIRE SETBACK36" FIRE SETBACKACDM(E) MAIN SERVICE PANEL(E) UTILITY METER(N) COMBINER BOX(N) AC DISCONNECTABJBCBFRONT OF RESIDENCE BACK OF RESIDENCEAAAAAAAAABBBB BBBBBBMSPLABEL LOCATION:POINT-OF-INTERCONNECTION OR ATMAIN SERVICE DISCONNECT (MSP)PER CODE: NEC 705.12(B)(2)(3)(b)! WARNING !INVERTER OUTPUT CONNECTION. DO NOTRELOCATE THIS OVERCURRENT DEVICE.SHEET NAMEPROJECT NAME & ADDRESS5810 TANGELO DR FORT PIERCE, FL 34982 ANDREW FUNSTON RESIDENCE Ph.#: (772) 501-7021 Email: andrewscottfunston@gmail.comREVDATEDESCRIPTIONREVISIONS ATLANTIC KEY ENERGY LLC+1 (407) 988-02737006 STAPOINT CTSTE BWINTER PARK, FL 32792Drawn by:N.R.Checked by:Date:2/23/22Sheet size:ANSI B 11" X 17"Scale:AS SHOWNSHEET NUMBERE-1SIGNATURE WITH SEALO.T.STRING LAYOUT &SIGNAGEADHESIVE FASTENED SIGNS:·ANSI Z535.4-2011 PRODUCT SAFETY SIGNS AND LABELS, PROVIDESGUIDELINES FOR SUITABLE FONT SIZES, WORDS, COLORS, SYMBOLS,AND LOCATION REQUIREMENTS FOR LABELS. NEC 110.21(B)(1).·THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTANDTHE ENVIRONMENT INVOLVED. NEC 110.21(B)(3).·ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLYADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT.LABEL LOCATION:COMBINER BOX/ EMTENCLOSURES/ AC DISCONNECT/MAIN SERVICE PANELPER CODE: NEC 2017, 690.13(B)LABEL LOCATION:CONDUIT/ RACEWAY/ ENCLOSURES/COMBINER BOX/ AC DISCONNECTPER CODE: NEC2017, 690.31(G)(3)(4)WARNINGPHOTOVOLTAIC POWER SOURCELABEL LOCATION:AC DISCONNECT/ BREAKER/POINTS OF CONNECTIONPER CODE: NEC2017, 690.13(B)LABEL LOCATION:AC DISCONNECTPER CODE: NEC2017, 690.53RATED AC OUTPUT CURRENT25.4NOMINAL OPERATING AC VOLTAGE240PHOTOVOLTAIC AC DISCONNECTLABEL LOCATION:RAPID SHUTDOWN(AC DISCONNECT)PER CODE: NEC 690.58 (C)(3)LABEL LOCATION:RAPID SHUTDOWN(AC DISCONNECT)PER CODE: NEC 690.56 (C)(1) &NFPA1 11.12.2.1.1.1.1, 11.12.2.1.4- UTILITY METERLEGENDM- EXISTING- NEW(E)(N)- MODULE STRING IDX- MAIN SERVICE PANELMSP- SUBPANELSP- JUNCTION BOXJB- STRING CENTER TAPSCT- CONDUIT- LOAD CENTERLC- AC DISCONNECTACDROOF PLAN WITH STRING LAYOUTSCALE: NTS1E-1- ENERGY STORAGEBAT- INTERCONNECTION DEVICEICDAVLABEL LOCATION:POINT OF INTERCONNECTIONPER CODE: NEC 2017, 705.12(B)- COMBINER BOXCB- BACK UP LOADS PANELBULPRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEAL, AND ALL SHA-1 AUTHENTICATION CODEMUST BE VERIFIED ON ANY ELECTRONIC COPIES. L1L2NGL1L2(N) NON-FUSED ACDISCONNECT10 ENPHASE IQ7PLUS-72-2-US MICROINVERTERS(N) STRING A10 Q.PEAK DUO BLK ML-G10+ 400W MODULES(N) STRING B11 ENPHASE IQ7PLUS-72-2-US MICROINVERTERS11 Q.PEAK DUO BLK ML-G10+ 400W MODULESL1L2(N) JUNCTIONBOXL1L2GG(N) IQ COMBINER BOXL2L1N20A/2P20A/2P10A/2P OR15A/2PENVOY124536AWG BARECOPPER( ) MAIN SERVICEPANEL, ANGL1L2L1L2L1L2L1L2L1L2L1L2(E) GROUNDELECTRODECONDUCTORL2L1NL2L1NTO UTILITYGRID(E) BI-DIRECTIONALUTILITY METERA/2P( ) MAIN BREAKERTO HOUSE, A(N) BACKFEEDBREAKER40225200EESHEET NAMEPROJECT NAME & ADDRESS5810 TANGELO DR FORT PIERCE, FL 34982 ANDREW FUNSTON RESIDENCE Ph.#: (772) 501-7021 Email: andrewscottfunston@gmail.comREVDATEDESCRIPTIONREVISIONS ATLANTIC KEY ENERGY LLC+1 (407) 988-02737006 STAPOINT CTSTE BWINTER PARK, FL 32792Drawn by:N.R.Checked by:Date:2/23/22Sheet size:ANSI B 11" X 17"Scale:AS SHOWNSHEET NUMBERE-2SIGNATURE WITH SEALO.T.STRING LAYOUT &SIGNAGE[NOTE]: LTNM OR EQUIVALENT TYPE CONDUITLEGEND- EXISTING- NEW(E)(N)ELECTRICAL LINE DIAGRAMSCALE: NTS1E-2DESIGN TEMPERATURE SPECIFICATIONSRECORD LOW TEMP-4°CAMBIENT TEMP (HIGH TEMP 2%)33°CCONDUIT HEIGHT1.0"CONDUCTOR TEMPERATURE RATE (ROOF)54°CIDTYPICALINITIALCONDUCTORLOCATIONFINALCONDUCTORLOCATIONCONDUCTOR (AWG)CONDUIT# OFPARALLELCIRCUITSCURRENT-CARRYINGCONDUCTORS IN CONDUITMAXOCPD(A)EGC (AWG)TEMP. CORR.FACTORCONDUIT FILLFACTORCONT.CURRENT(A)MAX.CURRENT(A)BASEAMP. (A)DERATEDAMP. (A)TERM.AMP.RATING(A)LENGTH(FT)VOLTAGEDROP (%)1 1STRING A JUNCTION BOX 12Q CABLE--12N/A6BARE COPPER0.7654°CN/A12.115.1 30N/A N/A52.0 0.432 1STRING B JUNCTION BOX 12Q CABLE--12N/A6BARE COPPER0.7654°CN/A13.316.630N/A N/A42.0 0.933 1 JUNCTION BOXIQ COMBINER BOX10 THWN-2 COPPERMN 0.75 DIALTNM2420 10 THWN-2 COPPER 0.76 54°C0.813.316.640 24.335 40.0 0.5741IQ COMBINERBOXAC DISCONNECT 8THWN-2COPPERMN 0.75 DIALTNM13N/A 10 THWN-2 COPPER 0.96 33°C125.431.855 52.850 5.0 0.0851ACDISCONNECTMSP8THWN-2 COPPERMN 0.75 DIALTNM1340 10THWN-2 COPPER0.9633°C125.431.855 52.850 5.0 0.08PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDEREDSIGNED AND SEAL, AND ALL SHA-1 AUTHENTICATION CODEMUST BE VERIFIED ON ANY ELECTRONIC COPIES. EQUIPMENTSPECIFICATIONSSHEET NAMEPROJECT NAME & ADDRESS5810 TANGELO DR FORT PIERCE, FL 34982 ANDREW FUNSTON RESIDENCE Ph.#: (772) 501-7021 Email: andrewscottfunston@gmail.comREVDATEDESCRIPTIONREVISIONS ATLANTIC KEY ENERGY LLC+1 (407) 988-02737006 STAPOINT CTSTE BWINTER PARK, FL 32792Drawn by:N.R.Checked by:Date:2/23/22Sheet size:ANSI B 11" X 17"Scale:AS SHOWNSHEET NUMBERE-3SIGNATURE WITH SEALO.T. SHEET NAMEPROJECT NAME & ADDRESS5810 TANGELO DR FORT PIERCE, FL 34982 ANDREW FUNSTON RESIDENCE Ph.#: (772) 501-7021 Email: andrewscottfunston@gmail.comREVDATEDESCRIPTIONREVISIONS ATLANTIC KEY ENERGY LLC+1 (407) 988-02737006 STAPOINT CTSTE BWINTER PARK, FL 32792Drawn by:N.R.Checked by:Date:2/23/22Sheet size:ANSI B 11" X 17"Scale:AS SHOWNSHEET NUMBERE-4SIGNATURE WITH SEALO.T.EQUIPMENTSPECIFICATIONS