HomeMy WebLinkAboutAPPROVED, DS1 2 3 4 5 6 7 8 9
RESIDENTIAL UNIVERSAL PV STRUCTURAL PLAN.
COMMON SOLAR COMPONENT EXAMPLES SHOWN,
APPEARANCE MAY VARY.
UNIRAC SOLARMOUNT UNIVERSAL INSTALLATION PLAN
CURRENT FBC 2020 (7TH EDITION) FLORIDA BUILDING
CODE & ALL REFERENCED STANDARDS
THIS UNIVERSAL PLAN IS INTENDED FOR RESIDENTIAL PV INSTALLATIONS
CONTRACTOR SHALL COMPLY WITH CURRENT NFPA 1 SOLAR PROVISIONS
ALLEN GEZELMAN
State of Florida, Professional
Engineer License No. PE 59180
16502 Hanna Rd,
Lutz, FL 33549
PH 813-909-1956
Allen@GezelmanPE.com
www.GezelmanPE.com
Plan Code:
UNIRAC DUO
rev11-04-2021 FLORIDA WIND ZONES ASCE 7-16FLASH LOC DUO ATTACHMENT
PZ1' : FIELD-OF-ROOF---- INTERIOR
PZ1 : FIELD-OF-ROOF---- EXTERIOR
PZ2 : ROOF PERIMETER
(MIN. 3' LEAST OF 40% EAVE HEIGHT OR 10% BUILDING L/W.
PZ3: OUTSIDE CORNERS
L & W =PZ2, a = PZ2 WIDTH., h = EAVE HEIGHT.
S5 PROTEA BRACKET
S5-U CLAMP
APPROVED METAL ROOF CLAMPS
DESIGNED FOR RISK II, V=ULT170 MPH.
EXPOSURE C, & V=ULT160 MPH. EXPOSURE D
PAPER PLANS SHALL BEAR
SIGNATURE & SEAL
If… This item has been electronically
signed and sealed by Allen Gezelman
on the date adjacent to the seal. Printed
copies of this document are not
considered signed and sealed and the
SHA authentication code must be
verified on any electronic copies
I CERTIFY THAT THE SHEETHING & FRAMING OF THIS STRUCTURE WILL SAFELY
ACCOMMODATE CALCULATED WIND UPIFT AND LATERAL FORCES AND EQUIPMENT
DEAD LOADS. THIS IS ATTESTED TO
MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.
1. THIS IS A SINGLE SHEET UNIVERSAL STRUCTURAL PLAN. ELECTRICAL PLAN IS
SEPARATELY SEALED DOCUMENT.
2. THIS PLAN OFFERS THREE INSTALLATION METHODS.
a. FRAMING METHOD. SEE DRAWING(s)
b. SHEATHING METHOD. SEE DRAWING(s)
c. STANDING SEAM METAL ROOF. USE CLAMP OF CHOICE;
ACE https://www.aceclamp.com/standing-seam-metal-roof-clamps
S-5 https://s-5.com/products/roof-clamps/
TRA http://trasnowandsun.com/product-category/solar-mounting/
3. CONTRACTOR SHALL MAKE CLEAR TO AHJ WHICH INSTALLATION DETAILS WILL BE
USED, AND PROVIDE OEM DATA SHEETS, MANUALS OR OTHER INFO REQUIRED BY AHJ
4. SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOAD TO STRUCTURE.
110
120
130
140
150
160
170
180
8. CONTRACTOR SHALL SUBMIT & ABIDE BY THE RAIL OEM INSTRUCTIONS.
FOLLOW OEM
INSTRUCTION SHEETS
FOR PROPER FLASHING
PLACEMENT
11 SITE SPECIFIC ADDRESS REQUIREDCONTRACTOR AKE SOLAR7006 Stapoint Court, Suite B, Winter Park, Florida 32792 407-819-4000 LIC# EC13009713Paulson Jolifils 622 Willows AvePort St. Lucie, FL 34952PART TABLE
P/N DESCRIPTION
004275M FLASHLOC DUO MILL, 20 PACK
004275D FLASHLOC DUO DARK, 20 PACK BND T-BOLT &
NUT 3/8”x1” SS
SS SERRATED
FLANGE NUT
FLASHLOC DTD
MILL OR DARK
#12-14 SCREW, HWH, SS, SELF-DR
W/ #12 EPDM WASHER
51 2"
31 2"
25 8"
43 8"