4 1 SLOPE
r3eiliira�l
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #IIL51.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9
wood screws with self sealing washer at 12" o.c. max spacing over
(type 2) 30 lb felt underlayment installed with min. 4' side laps
laps fastened with corrosion resistant tin caps and with 5" ring
spaced L" o.c. at all laps and two staggered rows 12" o.c. fie
deck to trusses using attachment detail on this sheet
,M D
2"
2„
O O c thick light textured
stucco on typical concrete
block construction
or
- - - - --- - - - - - - - - - - - 4 - - - -- - - - - - - - - - - - - - - - - - - ;;&
5/8" thick x 8"W cut
coral finished stucco bands
LEFT ELEVAT10N
I2" 5/8" thick x 8"W cut
H. coral finished stucco bands
3 /
SCALE: 1/4' = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood7 screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced b" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
L�� 3
�5/8" thick light textured
stucco on tgpical concrete
block construction
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Finish Columns with
5/8" thick cut coral
finished stucco bands
=L=VATIOkl k10
5/8" thick x 8"w cut
coral finished stucco bands
TES:
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max tkpacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6" end
laps Fastened with corrosion resistant tin caps and with 1.25" ring shank nails
in spaced 6" o.c. at all laps and two staggered rows 12" OA;z field. Attach
deck to trusses using attachment detail on this sheet
0
C
5/8" thick light textured
stucco on tgpical concrete
block construction
REAR ELEVATiON
Overhangs at 1'-O" unless otherwise noted on Roof Flan
Roof pitch at -{:12 unless otherwise noted
Arc changes to this plan shall be submitted to the architect
for approval in writing prior to starting construction.
Return ALL Stucco Bands Into Window or Door.
12
SLOPE 4
RIGHT ELEVA710N
SCALE: 1/4" = 1'-0"
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, 1Pmdows & Skylights
Opening
Type
NOA/FL
NUMBER
Product
Model #
Manufacturer
Glass
Attachment method
' ation
Date
Design Pressure
of Approved Tests
1.2.3
t4
FLU 11499.2
Single Hung
Series 185
MI Windows
and doors
L ia. x gpcans W me. ggne2rptlon at mqX
tom each corner end L o.c. t area ter Lhrou h PT Buck Into solid
filled CMU wall maintaining min 2.5" edge distance In strict adherence
to the product approval.
± 60 psf
A
16-0330.02
Overhead
Garage Door
Model 824/811
9'-4" max width
I6'-o" max height
DAB
mta x uc to canerete ec m , • ce m,t
n 45 bar Ve t. atop 3/e' x R' H114 HLC sleeve anthem at Al' ax-
h 1.15' Me. was era wink mia 1' edes dntanes. Install track to buck
N (1) 5156•edpI 5/r ci threadiao awrous in eachtoackst maepprwel
ranee vie• nut washer an raller shMes
10-9-21
50.0/-60.0 psf
B
PL# ILL14.1
Fiberglass
Design Pro/
Smooth Pro
Jeld-Wen
Elco 1/4" dia. tapcon with min 1.25" embedment at 3" max
from corners and 11.5" o.c. max thereafter In head and jambs.
+ 50.0 PSF
C
FLU 15332.2
Sliding Glass
Door
Series 420
Mt Windows
and doors
'f G iq. x cone a{ mi^. Renetration at � max.
tom each corner end o.c. a EaCle row t ereafter throug
PT Buck into solid filled CMU wall maintaimng in 2.5" edge distance
m strict adherence to the product a royal.
+ 48.2 PSF
-
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
TEST
Expiration
Date
Design Pressure
B
of Approved Tests
Mullions
FLU 15353.8
CM-18531
vertical mullion
MI Windows
and doors
For CMU use (2) 1/4" x 2 3/4" tapeons with min 1 1/4" embedment
penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25"
self tapping screws per clip as shown in product approval.
+ 118.9 P$F
_
Roof
FLU 11L51.12
5V Crimp
Metal RooFing
Gulf Coast Supply
and manufacturing
26 ga. 5v crimp metal roofing attached to plywood deck using R9 x I.5"
wood screws with self sealing washer at 12" o.c. max a acing over ASTM D
(t a 2) 3o lb felt underla ment installed with min. 4p side laps and 6" end
eP s p
laps Fastened with corrosion resistant tin cape and with 1.25" ring shank nails
spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to true". using attachment detail on roof plan
- 108.5 P$F
Siding
Stucco on Block
Soffit
FLU 12198.3
Model T4 12" vented
Vinyl Soffit
y
Kaycan
Install using 2" x 2" battens at 6" c.c. screwed to soffit framing using
Its x 3" wood screws at each truss. Install soffit to battens using
O. 2" dia. x 1,5" lcma rina shank n 8" dia. head.
+55.0/-35.0 PSF
Hurricane 24 Gauge Global P; otectlon
Panels Fin 15014.2 Storm Panels Products LLC
I have reviewed the above and appro led it
Install using 1/2" dia. solid set lead anchors with 1/4" dia.-20 x 1.5"
long SS screw head combo. with Neoprene washer at 12 1/2" o.c. + 45
along the bottom and 13" o.c. at the top O PSF
by my seal below. ( Architect or Engineer of Record
12
SLOPE 4
Finish Columns with
5/8" thick cut coral
finished stucco bands
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x LS"
wood screws with self sealing washer at 12" o.cmax spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.26" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
2" I
8'-1" T.O.B.
H
a. ®® .
5/8" thick x cut
coral finished stuccoo bands
" = Finished Floor Finish Columns with 5/8" thick light textured
WOO, qv 5/8" thick cut coral stucco on tgpical concrete
finished stucco bands block construction
FRONT ELEVATiON
2" x 4" top plate 1/2" drywall ceiling on truss bottom cord
1/2" drgwall on
2" x 4" studs at W' o.c.
base -board 11 11 / 2" x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
L"xC 410/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
nterior Non-Bearine Fdrtition
Braden lit
Braden AIA, PA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
: (112) 287-8258
Fax
: (112) 281-8283
E-mail.
bradeneia5comcast.net
Stuart. FL
3499L #AAC000032
nts
UJynne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
8'-1" T.O.B
we L
0'-0" = Finished Floor
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" COX Plgwood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12
SLOPE 4
SCALE: 1/4" = 1'-0"
--- 5/8" thick x 8"w cut
coral finished stucco bands
-O'-V A.F.F.
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Categorg; II Wind Velocity: 165 mph ultimate
Mean Roof Height: ll'- " Roof Pitch: 4:12
Internal Pressure Coefr if c ent: ±0.18
SubJectabilitg to damage from: Weathering: Negligible Termites. -Very Heavy
Width of Roof End Zone: 3'-4" Wind Speed: 145 mph ultimate
Wind Exposure Classification: C 1.21 x O.6 = 0.126
Adjustment factor for Exposure Height: ASO design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+0.6WL; O.6DL+O.4WL
Components t Cladding Wind Pressure (NET) Roof Zone: 1. +20.4/-32.6 psf
Roof Zone: 2. +20.6/-51.0 par
Roof Zone: S. +20.4/-84.0 psf
Components t Cladding Wall End Zone Width: 3'_4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 psf
Wall Zone: 5. +35.8/-41.8 par
Components ( Cladding Wind Pressure (NET) on Garage Door. +32.0/-40.3 par
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? `(es
Are Components an Cladding Details Provided? Yes
Minimum Soil Bearing Pressure:2,500 psi. Presumptive: X By Test: psl
This Building Shall Have the Following:
APPROVED SHATTERS: X IMPACT GLASS: BOTH: NEITHER:
ROOF LIVE LOAD: _3'1 psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: J5 psf FLOOR DEAD LOAD: 10 oaf
JOB ADDRESS: V)\��.Q �2
MODEL: Date Drawn Revisions
GARAGE Drawn bg:
RIGHT C.C.U.
Checked bg:
C..IR.B.
ITCH
F-1 = Roof Zone I
Walla Zone 4
= Roof Zone 2
Walls Zone 5
END ZONE
Corner Zones
Roof Zone 3
Sheet
OF 5
Comm #
12-27
rFL•OOR FLAN
CRASH POST DETAIL
TYPICAL NOTES: SCALE 1/4" = 1'-0" N.T.S.
I. Contractor to verif ALL notes and dimensions rior to high by 4° diameter
y p ssteteel crash post. Floor
proceeding with work. Flange with 4 - 3/8"
2. Contractor to STRICTLY enforce ALL OSHA Requirements. expansionab boltsinto
ks� steel plate)
3. ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress. `'"
4. No dissimilar metals to touch. 2'/S.
S.
ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
A
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
6.
Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws per FBC R102.3.5.
1.
ALL wood in contact with concrete shall be pressure treated.
8.
ALL wall dimensions are nominal and not finished wall or stud dimensions.
9.
ALL plumbing fixtures to be low flow.
10.
Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11.
Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements. y;
12.
Lowest finished floor to be set by Governing Building Department
`
surveyor to set in field.
13.
Separation between residence and garage shall be per FBC R302.6
14.
Door between garage and residence shall be 1-3/4"t 20 min. rated door
w.H. = Water Heater
15.
Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC
R302.9.1
16.
Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC
R302.9.2
11.
All exposed attic insulation materials installed on attic floors shall have a critical radiant
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
I" x 6" P.T. Buck nails
block with case hardens
materials exposed on the underside of the roof deck or on the attic walls shall comply
prior to door attachmer
with F.B.C. R316 - see permit info box of code edition
18.
Gypsum board material shall conform to ASTM C36, C19, C415, C514, C630, C931
C40, C1002, C1041,C117-1, C1118, C1218, C1395, or C1396 and shall be installed
according to the following: (FBC R102.3.5)
Drywall
Thickness
Location
Orientation
Framing
Member
Max. spacing
of fasteners
Nail sizing options for
drywall
Spacing
Maximum
installation of Into
wood framin members
Nails
Screws
2" x min. thickness
Ceding
Perpendicular
24"
11.
12"
13ga 1 3/8" long with 19/64" head
OR
0.098" diameter x 1 1/4" long
annular -ringed or 5d cooler nail
0.080" dia. x 1 5/8" long with
Walls
Either
16"
8"
16 "
Direction
15/6 4" head
OR
Gypsum board nail 0.086" din.
x 15/8" with 9/32" head.
Ceding
Perpendicular
24"
1"
121,
i3ga 1 5/8" long with 19/64" head
OR
0.098" diameter x 1 3/8" long
annular -ringed or 6d cooler nail
e
OR
Walls
Either
16"
all
16"
0.092" dia. xx 1 1/8" long with
Direction
1/4" head
OR
Gypsum board nail 0.0915" dia.
x I I/8" with 19/64" head.
Install SGD thru buck Into
block with 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product appre
19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C11�18 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas_
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanying smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal rooring FL #11661.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.26" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Simpson HETA. 20 or
equal
hurricane anchor at each
truss
12
With (10) lod x 1 1/2"
( 24" o.c.) supporting
nails
Max.
4 �-
PRE-ENGINEERED TRUSSES
24"o.c. TYPICAL
1810lbs. upift
at
(shop drawings by manufacturer)
Aluminum Drip \R-30 blown fiberglass
Edge t Fascia in bottom chord of trusses
1/2' drywall with smooth finish
2" x 6" Sub-Fas;la�7
Two rows of beam block filled with concrete
and (1) #5 bar Cont. in each row. Substitute
Kagcan full o vent viagl soffit installed precast lintel filled with concrete and (1) #5
using 1/8" din shank x 15" long galv. bar cont. for bottom row over openings
roofing nails with 3/8" dia. head per
product approval - see chart sheet #1 1/2" drywall over I" x furringg
strips at 14" o.c. with R4.1 fr-fod
nsulation on typical 8" Block walls
5/8" thick light textured = All drywall to be Installed per FBC R102.3,1
stucco on typical concrete T and shall meet all pertainin ASTM codes.
block construction Mortar to be Type "M" only proportioned per FBC R601.1
and Mortar Jonts shall comply with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
#5 bar Vert. w/
30" overlap Fill cell with concrete and
at each filled cell (1) #5 bar Vert. (typical).
Max. spacing shall not exceed
Wood 48' unless otherwise noted
Base see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
6"xG" 910/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Grade `+ ...'_....,..:..
-'��I IIII = _ III IIII=IIII= "'I
=IIII=IIII=III=III=III
-IIII i 11. 14" x 14" Concrete footing
�/ 7 f� 14" with (2) #5 bars cont. and #5
TI I C A L. S E C T ION transverse bars at 48" o.c.
Scale : 1/2" = I'-O"
�2"
O
2'/,°
2
0 0
to
Masonry Beam
/
nails
C
Head
fixed door
sliding door
1/2"
Bottom Track T
Sill
Sliding Door Detail
At Masonry Wall NTS
AREA CALCULATIONS
Living A/C =
14,46
sq.
ft.
Front Porch =
1,41
sq.
ft.
Rear Porch =
200
sq.
ft.
Garage =
321
sq.
ft.
Total Under Roof=
2108
sq.
ft.
2' VTR
JIL
I
I
I
I
21' VTR
Masterrx� JIL
Bath i
i 2•hrl
2• Lr I
Lev.
,• 2' VTR
w.c. JIL
3' i
2.
Sher. 3" ' I
Kit. sink I
I
Kitchen 2 i
I
Lay.
3"
W.C.
Bath #2 Sher,
3•
c.o- TC septic
PLUMBING RISER
I" x 6" P.T. Buck nailed to
block with case hardened nails
prior to door attachment ,
Masonry Wall
ypical Flooring _
Install SGD thru buck into
block with 3/14" tap -con with
1 1/2" penetration at 6 o.c. max.
from each corner and 20." o.c. max
thereafter at Jambs per product approval Jamb
Window
Schedule
Mark
Size
Rou h O en.
Window Description
PRESSURE ZONE
I.
4'-5%"x 5'-3%"
5'08"x 63%4"
Single Hung
ZONE 4
2,
6'-2%s"x 5'-3 %s"
Is" x 63 114"
Single Hung
ZONE 4
3.
2'-2" x 3'-2 1/2"
21%2"x 38%"
Single Hung
ZONE 4
4.
4'-5%"x 4`2%a"
54%a"x 54N'
Single Hung
ZONE 4
ALL
Windows to be aluminum
Windows w/ tint
and mullions per
elevations.
ALL
windows to withstand
pressures in permit info box on
sheet I
ALL
windows in bathrooms to
be tempered
All
rough opening
dimensions
to be verified by contractor
with
manufacturer s specs prior to construction
Door Schedule
Mark
Size
Rough Opening
Door Description
PRESSURE ZONE
A
9'-0,, X 1'-O"
108" x 84"
Overhead Garage Door
ZONE 4
B
3'-0" X 6'-8"
41 %i"x 83%"
Fiberglass Panel - Inswing
ZONE 4
C
6'-0" X 6'-8"
l4" x 81 %;' ; ;;bot;a"
Sliding Glass Door
L ZONE 4
D
2'-0" X 6'-8"
Solid Core - Wood
- 6-Panel -Bi-Fold
Finished 24" x 811/2"
E
2'-6" X 6'-8"
Solid Core - Wood
- 6-Panel
F
5'-0" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
G
2'-8" x 6'-8" x I %;'
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X 6'-8"
Solid Core - Wood
- 6-11anel
1
2'-6" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
K
2'-8" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 1*1
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO 60X ON SHEET 41
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
Ir
Install windows thru buck Into
block with 3/I6" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at jambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall -\ / \ Buck to be I" x 4" PT
__-_-block
P.T. Buck nailed to
t-., blocck with case hardened Wads
JJ & t a l l a t w I n d OW S prior to window attachment
Braden I Braden ,AIA, PA
Architects - Planners
411 S.E. Coconut Avenue
Tel : (712) 281-8258
Fax : (172) 281-8283
E-mail: bradenaia8comcast.net
Stuart. FL 34994 #AAC000032
NTS
wynne Bulldlnca Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
12"
Attach buck to block wall with
1/4" dia. Elco conic screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2" x V PT Buck
of wall
Varies
71:J
INSTALL VULKEM BLOCK SEALANT #8 Wood screws thru jamb into buck
ON ALL JAMB, HEADER, AND at each hinge and 15" o.c. max and
SILL BLOCK PRIOR TO BUCK Detail at Door prior to door attachment
INSTALLATION
- NTS
MODEL: Onto Drawn : Revisions Sheet Comm #
GARAGE 5-9-11
RIGHT Orawn by: I l
2-27
C.C.LI..
Checked bg:
D.R_B. OF 5
�'i:NF? Et,✓��LKI
34,-G
I.
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
9,
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2,
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
10
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4,000 PSi GROUT MIX AT 28 DAYS
3-
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS, NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
II
4
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12.
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL TO BE SPREAD IN 12" LAYERS AND
MACHINE COMPACTED TO A MINIMUM OF 2500 PSI IN AREA OF
13.
BUILDING CONSTRUCTION
6•
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
14.
l•
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
15.
ATTENTION OF THE ARCHITECT.
I6.
8•
GARAGE FLOORS TO BE SMOOTH TROWEL FiNISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
IT
FOLAD,470N FL.4N
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-I6, t
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1400 PSI
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fib OF 1000
PSI OF NO.2 SOUTHERN FINE, UNLESS NOTED OTHERWISE,
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
I. Any changes to plans must be submitted to the architect
for approval before proceeding With construction.
2• Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in Writing for revision
4. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and I US bar Vert, at 48"
o.c. max. Provide (1) filled cell on each side of openings up to 5'—I1" wide.
Provide (2) filled cells on each side of openings from 6'—O" to 9'—II"
and Provide (3) filled cells on each side of openings from 10'—O" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" o.c, unless otherwise noted (see section)
6. Contractor to provide for Form Board Survey — Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing Steel shall be grade 40, meeting ASTM A-14 and
A-3S specifications. ALL Anchors to be A-30-1 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
SCALE: 114" = 1'-0"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic pipin penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
#5 bar vert. w/
Thicken edge to 8"x8"
30" overlap
SEE TYPICAL
ECTIONS
with concrete and 4" concrete slab with fibermesh OR
at each filled cell
one its bar continuous 6""" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
4" concrete slab with fibermesh OR
GRADE
Vxt" #10/10 WWM on 10 mil Visqueen over
.,;:;
clean compacted termite treated fill
- — —
Grade
1 III
_
—III i li l ,—IIII—
all
III —IIII
III IIII— ' 14"w x 14"d concrete monolithic
PORCH SLAB EDGE DETAIL
8
„ footing with (2) tt5 bars cont.
SCALE 1/2"
14"
TYPICAL FOOTING DETAIL
#5 bar vert. w/
30" overlap
SCALE 1/2" = I'-O°
at each filled cell
SEE TYPICAL
�ECTIONS
4" concrete
slab with fibermesh OR
Adjust curb height
6"x6" 410/10
WWM on 10 mil Visqueen over
based on gar_ floor 4" concrete slab with fibermesh OR
clean compacted termite treated fill
slope. VxC #10/10 WWM on 10 mrl Visqueen over
#5 bar Cont.
#5 bar in curb clean compacted termite treated fill
Step per
0'-0" s F.F.
foundation plan
Grade
-
IIII
101. (2) 45 bars cost. bottom steel
_-11111
14"w x 14"d concrete monolithic
IIII I i—i footing with (2) 45 bars Cont.
12"
14"
2 DETAIL
AT GARAGE STEPDOWN
SCALE 1/21, = 1'-0"
GARAGE CURB DETAIL
12" x 12' concrete column
SCALE 1/2"
block filled with concrete
and (2) 41 bars vert. ied
into hotels above
Verify house slab
height in field
Top of tooter
IL" below flrnshed floor
i
-IIII=IIII
�.::::.:. •
: , ,_
3p x30"xld" concrete
,;-:, :...;. eolimn footing with (4)
„
2 x 6 PT wood secured with
_
bars each wag
g
3/8"dia. x 6" anchor bolt at 18' o.c.
overhead door track sequred to wood
jamb per manufacturers product approval
30"
Garage Door Jamb Detail
Oj COLUMN
FOOTING DETAIL
GARAGE DOOR To WITHSTAND PRESSURES STATED
N T S
IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT
SCALE 1/2" = I'-O"
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Filled Cell Masonry Column With One
#5 From Footing To Tie Beam
Conc, Fill To Be 3000 PSI
See Floor Plan For Location
O
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
#5 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
Braden it Braden AIA, PA
Architects - Planners
411 S.E. Coconut Avenud
Tel : (112) 281-8258
Fax : (112) 281-8283
i1B E-mail: bradenaiaecomcast.net
Stuart. FL 34994 #AACO00032
a
20'-0"
L
— —
4 ° r---------�0
� L
1 �� _ �� 4 I FI
p Filled cell under - 1
girder above O I FI
4 I
—
Rear Patio/Slab
-7
—
I W o be poured separate L, I
CL From the house slab.
I O ic,
to
Thicken footing to
24"w
x A"d x 24"L
a I under filled cell FI I
CpI I I I I I I I 1 31 1 Ela MA- Q Q ° under girder bearing.
r- — — — —— — — —— — — — J
Rear Patro/Slab to 1
0
°
I be Flush with bottom of
rut)
I sliding door recess.
Slope 1/2"
av
`nu=
i
I
I
FI I
32'-8"
I
I
concrete slab with fibermesh OR 1
H.S.
6"x6" 410/I WWM on 4 mil Visqueen over �O
1 clean compacted termite treated fill
I
I Fl l
_
1
°1
I
to
I
f—
I
cr
I
B.
I
,
°
O o EVA
_LA_
4, -0,.
°I
f
FI
i W @4"4 Steel Ballard
filled w/ Concrete
_ a
p^l >
\r�/I
u09
��m 1
ORE)
a
1 I I 1
1
u-
I I �
e�
J I E
N I
cV
o
/° UD 0
1
r
°
- �•� v O
I
00 `u
o
o
L— — — — --- —� 18N
I
C Q U
Oo Oo I I I I I 1 °O oO _ =W—
i I l vim, `F51
o
(nu�
I CL V' I
°
O za
X
r
L_—__ Recess for F5 I
°�----�---
° —JO
— — Garage Door ° O
°
3 F
�
'�\12" x 12" concrete column block filled
with concrete and (2) #1 bars vert. tied
into lintels above
l.U(ynne Building Corp.
The Grard Cdrlton
Spanish Lakes
St. Lucie County Florida
FOOTING
SCHEDULE
Mark
Size
Description
I
1411.1
x 14"D
MONOLITHIC FOOTING
WITH 2 tt5 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) #5 BARS CONTINUOUS
930,
x 30" x 14-r)
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
"Wx8"DTHICKEN
SLAB EDGE
WITH 1 #5 BAR CONTINUOUS
4"W:C)
tith
urb at Garage
ONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB s O'-0"
MODEL:
Date Drawn
Revisions
5-9-11
GARAGE
Drawn bg:
RIGHT
C.C.U_
Checked by:
D.R.B.
Sheet
Comm #
a -
12-27
OF 5
IN
ROOF SHEETING
�4TTACHNENT DE7AIL
I. Minimum Nall Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Slze = 48 x 2"
3. Minimum Sheathing Thickness 19/32" CDX Plywood
4. Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Ke
Area
Edge
Field
Fastener
Pressure
Zone I
(o
Bidring shank
45 psf
Zone 2
4"
�"
8d ring shank
16 psf
Zone 3
4"
4"
Sd ring shank
84 psf
** Zone 3a
6"
6"
48 wood screw
112.5 psf
** Use nails or screws based on pres§ure for roof stated
in permit info box on these plans ?or zone 3
Verify with Plan
Concrete 12 "x 12"
/Lintel Column Block
Rebar
Rebar 48 Bar Dia-
tom. Overlap
Column to Lintel Attachment
NTS
Provide 45 bars with min. 48 bar
diameters overlap into beam. Tie
filled cell steel Into continuous
beam block steel t\
Provide Cast -Crete
SUB-OB/OT precast
lintel set in mortar
Min. 8" Bearing -- --,- ---
Provide #5 bar set in pfe-cast
lintel into beam where length of
the opening calls for it.
Provide PT Buck
attached per jamb
ietads into filled c
4" Pre -cast
Sill
Yr_
Filled Cell
Provide #5 bars with min. 48 bar
diameters overlap in filled cell. Tie
filled cell steel into continuous
footer steel.
CBS WALL Scale. 1/2"
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blockinrq to Vert. leg of
truss with 10d x LS' nails at 4" o.c.
Install Simpson MGT Into wall using
5/8" dia. threaded rod set min. 12"
into wet beam and (22) IOd nails into truss
3LOCKiN G DI. TAIL
)ER 37RAPPiNG
TER BEARING POINT
1/8" thick fight textured stucco installed per
ASTM C 929 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Tgpe 2 felt paper using 8d nails. 5ubstrate
to be 19/32' COX Plywood nailed at 6" o.c. in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #11651.12
26 Sal, Sv crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 Ib Felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1-25" ring shank nails
spaced 6 o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet �\
Additional Precast Lintel
#5 bars
F
9 CLEAR
' •:'.+^r
Lintel
Length
Bar
Length
Clear
Span
u A n
Bars
u u
B
Bars
2'-10"
2'-8"
I'-6"
2,#3
none
1 1 1 1 1
3'-6"
3'-4"
2'-2"
2,43
none
8IP8-OBAT 8F8-IB/IT 8F8-IB/2T
Additional
4'-0"
3'-10"
2'-8"
2,#3
none
- tt5 bars
';,% "'
CLEAR ^%
4'-6"
4'-4"
3'-2"
2,43
none
;' ,•'.. ne Row of "H" ,
5'-4"
5'-2"
4'-O"
2 #3
none
Block Above .: %':
y.,'•;
Precast Lintel :"
5'-10"
5'-81,
4'-6"
2 #4
none
r ;.` 7
:'• i
Additional`"'' +
6'
2,#4
none
tt5 bars t____s
1'-6"
i'-O"
6'-2"
2#S
none
BfIL-IB/IT BFI6-IB/2T
8,-4"
T-10"
1'-0"
2,#S
none
NOTES:
ALL reinforcing steel is grade 60.
I. min. coverage of steel-1.5"
2. min. bearing required 9 ea. end=8"
3. standard for reinr. steel=ASTM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
Window
or Door
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"H" Block
Above
Bottom
Steel
size
Top
steel
size
Max
Gravity
Load
(PLP)
Max
Uplift
Load
(PLF)
Max
Lateral
Load
IPLF)
L22
2'-2"
3'-V
8F8-015/IT
I
#5
3069
1569
1024
L31
T-L"
2'-8"
V-1"
4'-O"
8F8-OB/IT
I
tt5
250
130
143
L45
4'-5"
5'-10"
8F8-OB/IT
1
#5
1 1105
909
1 339
L50
5'-O"
C-L"
8f8-OBAT
1
#5
1238
835
1 121
L40
6'-8.
T-I'
8F8-OBAT
I
#5
1011
121
534
LBO
8'-0"
T-4"
SIPS-I13/2T
1
tt5
2
#5
152.
591
612
L90
9'-0"
10'-6"
BFS-IB/2T
i
#5
2
45
443
530
401
L90B
T-O"
10'-4"
81=I4-IB/2T
ONE
1
#5
2
#5
1533
1183
401
LI00
10'-0"
II'-4"
BF8-IB/2T
1
#5
2
#5
582
494
452
LIOOB
10'-0"
II'-4"
8FIL-IB/2T
ONE
I
tt5
2
#5
1366
1028
452
LI20
12'-O"
13'-4"
Or-IB/2T
1
#5
2
#5
411
128
324
L120B
12'-O"
13'-4"
8FI4-I5/2T
ONE
I
#5
2
#5
1 1015
110
324
L140
14'-O"
15'-4"
8FIL-I15/2T
ONE
1
#5
2
#5
1 1250
1.09
259
L160
I1'-0"
11'-4"
8F8-I15/2T
1
#5
2
#5 1
300
192
194
L160B 1
IL'-O" 1
IT-4"
SIP16-8/2T
ONE
1
#5
2
#5
950
500
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FiLLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AHO SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2" nails —
( 24" o.c.) supporting Max.
1810lbs. uplift
Aluminum Drip
Edge t Fascis
12"
2" x 6" Sub-Fascl
Kagcan full o vent vingl soffit installed
using 1/8" dia shank x 15" long gals.
roofing Haile with 3/8" dia. heed per
product approval - see chart sheet #1
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vent. tied_ ---
into lintels above
thicken edge to 8"x8"
with concrete and
one 95 bar continuous
BEYOND
Top of rooter
14" below finished floor
12
4
Aluminum Drip
Edge d Fascia
Poured Cc
concrete t
Poured Concret
concrete block i
Concrete ,
Manufacture
Flash and Counter
flash
Nail ledger to
gable end truQ11S\
with (2) 10d
at each web
1/2" thick stucco on 3/8" hi -rib lath
attached to horizontal and vertical wood
framing with nails or staples to provide
no less than 1-3/4" penetration into
horizontal wood framing and 3/4" penetration
into vertical wood framing members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#S bar Vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Step per foundation plan
a Slope per foundation plan
chore Per
Specs
lax.
Flush Mounted Shutter Detail
fl�I
Aluminum Panel
sizes per manufacturer
— Sae Tunica[ Stud Detail
1/8" x 3/52" Wing Nut w/
appropriate masher and spacing
`u per manufacturer's Details
!3 OL3"
V
� 099'
co
m
77I1�
Stud Detail
Stud w/ Die Cast Zinc NTa
Nickel Plated Wing Nut
v4'
nts
Brace Gable end
with 2" x 4" SYP #2
Slit back nailed to bottom
Of top chords using (2) IOd
nails at each truss
RE -ENGINEERED WOOD TRUSSES
® 24"o.c. TYPICAL
( shop drawings by manufacturer )
�R-30 blown fiberglass
in bottom chord of trusses
-1/2" drywall with smooth finish
Two rows of beam block filled with concrete
-and (1) #5 bar cont, in each row. Substitute
precast lintel filled with concrete and (1) #5
bar cont. for bottom row over openings
1/2" drgwall over 1" x furringg
strips at 14" o.c. with R4.1 fl-foll
-insulation on typical 8" Block walls
to UJI
h--
It-x
+u
r �
0 U1
N +-1 +J
F_ a ° a
a
LL
Ld L
0 u) wl
u
EO c U
E_ q : 00
uN
L
L �
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" only proportioned �pper FBC R601.1
and Mortar joints shall comply with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and O
(I) #5 bar Vert. (typicaU.
-Max. spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for — OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
spacing at openings — 4" concrete slab with flbarmesh OR GOOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THiS SHEET
VxV #10/10 WWM on 6 mil Visqueen over — TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
/clean compacted termite treated fill — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
5lmpson
Ht= I A 1U
Strap
truss to
wall using Simpson
MGT with
hurricane anchor at each truss
5/8" dia.
threaded
rod with min 12"
embedment
( 24" o.c.)
supporting Max.
into
beam either
wet set or in
epoxy with
1810
lbs. uplift ETA 2p�
(22)
IOd nails
truss
into truss. Add
leg per detail on
blocking to
this sheet
Q
W
•
N
L90
L90
BI
BI
BI
BI
0
I
L90 B 1
BI
LLO
W
d
I
~
^
I2
~ I
W ^
a3 I 0till�t-
tn n 4-
7
2"
BI
to
��
I I
WWI
I W [_ E
S OPE N
q- 1
I W
U] a
1
N
W
I
I W Lo
L31
'.
W
ZZ ZZ
N
O_
E
Gulf Coast Su I and MFG 5
C im Metal roofin FL #11451.12
Q
- woo screws witfi self sealing w
sher at 12" o.c. max spacing over AS21
TM D
H
(type 2) 30 Ib felt uin erlagme
t installed with min. 4 side laps and 6" end
Is s fastened with corrosion re
ista t tin caps and with 1.25" findshank nails
eck to trusses using attachme
t detai on this sheet
O
twth
1
hctN I
� �
d
— — — - SLOPE
B1 I 1 I U up
1 1 ( P
tad
r
I
8'-0" MAX.
I
with 2" x
eft back
I ( T 5
5
of top chc
I
TI
I
I
n
I
z
I L
I
I
O I
I
I
I I BI L31
I
I
co I
I
BI I BI
I
I
B1 L45
2
I
Bl
N
` o
L50 on
HET4
2
H m
hurrica anc
r at
eacl
trus
to
BI
( c.)
uppo
ting
ax.
tr
y
1810
bs. u
ligqft
B1
BI
BI
L1b10
LLO11
L90B
to
IIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I kil_liii
=I e F1
IIII I4
"II�II� �iTi II11-IiII= F3 TQ)ical Section at Front Fora
Scale
: 1/2" = 1'-0"
Braden t
Braden AIA, P/
Architects
— Planners
411
S.E. Coconut Avenue
Tel
: (172) 287-8258
Fax
: (712) 287-8283
E—mail:
bradenaiascomcast.net
Stuart. FL
3499(. #AAC000032
FL/4N
e)
to
x
N is
c 5-
u rn
ro �
L 4—
(13 o LL
CL
L
O d) aj
c
16 O
o —
W pp
u ty
L
c
Brace Gable
4" SYP #2
nailed to bot
rds using (2)
ails at each ti
�1
ARCHITECT FOR APPROVAL iN WRITING PRIOR TO STARTING CONSTRUCTION.
ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRiOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION
Wgnne Building Corp. MODEL: Dade Drawn : Revisions : Sheet Comm tt
GARAGE-q—I1
The r d r d Carlton RIGHT drawn b,: 12-2�1
ct.C.0-
Spanlsh Lakes Checked bll:
St. Lucie County Florida Ej.R-g- OF 5
PANEL
"A"
circ# Description Wire Load BR Poles
2 AHU #10 3.5 kw 30 2
4
Poles
BR
Load
Wire
Description
circ#
2
40
1.0 kw
#8
A/C comp
1
3
6
Ranme
2
30
4.5 kw
#l0
40 gal. water HTR
5
46
12.0 kw
50
2
I
8
1
20
1.8 kw
U12
Pump
9
10
Dr er
#10
5.0 kw
30
2
11
12
1
20
1.5 kw
#12
13
14
Dishwasher
#12
1.2 kw
20
1
1
20
1.5 kw
412
Microwave
is
16
Refrigerator
#12
1.2 kw
20
1
I
20
1.5 kw
31:12
Kitchen S.A.C.
m
18
Recepts
tt12
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
19
20
Recepts
412
20
1
1
20
1.2 kw
#12
Clothes Washer
21
22
Recepts
#12
20
1
1
20
0.81 kw
#12
Garage Door opener
23
24
Recepts
412
20
1
1
20
1A kw
#12
25
26
Recepts
#12
20
1
1
20
1.92 kw
#12
21
28
Recepts
412
20
1
1
20
#12
General Lighting
29
30
Recepts
#12
20
1
1
20
#12
General Lighting
31
32
Recepts
#12
20
1
1
20
412
General Lighting
33
34
Exterior GFCI
#12
20
1
1
20
#12
General Lighting
35
36
Bathroom GFI
412
20
1
1
20
#12
Smoke Detectors
3"f
38
General Lighting
412
20
1
1
20
#12
Bathroom GFI
39
40
General Lighting
#12
20
1
spare
41
42
s are
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
General Lighting (3 Watts sq. ft.) . . . . .. . . . .. . .. . ..
Small. A.pphance. Circuit(s). _ . _ . _ ...... ..........
.Range
Refrigerator.
Microwave.....................................................
Dish Washer
Clothes,.W.a.sher...............................................
Clothes..Dryer................................................
Water Heater
.......I......
Water, .Pump ................................:..................
Garage Door Opener
1735
3
5,205
2
1,500
3,000
1
12,000
12'000
1
1,200
1,200
1
1,500
1,500
1
1,200
1,200
1
1,200
1,200
1
5,000
5,000
I
4.500
4,500
1
1,800
1,800
I
810
810
Total Watts 37,415
First 10000 Watts 5100% 1 10,000 10,000
Remainder 27,415 W40%
1
O
10,966
Electric Heat or A/C 10,000 845%
1
10,000
10,000
Calculated Load
Watts
30,964
Volta e
240
Calculated Wattage Divided bg Voltage = Total Amps 129.03
Panel Sac Required = 150 Amps
Electrical S mbol Legend
S
Single Pole Switch
®
Recessed Can Light
S3
Double Pole Switch
®
Eyeball Recessed
P5
Push Button Switch
Exhaust Fan
Duplex Outlet
¢
Ceiling Mounted Light
Special Receptacle
O-
Wall Mounted Light
J.P. QrQ
Waterproof ground fault circuit
interrupter
ft
Light with bull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
-cm- 1
Carbon Monoxide Detector
'V
Flood Light
(D
Thermostat
m
Electrical Panel
©
Central Vac
g
Electrical Meter
Q
Smoke Detector
Ceiling fan
©
Television Jack
JTtI
Telephone Jack
ncs c
A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
SPKR
Speaker Hook -Up
Intercom
H.B.
Vent thru
S r1t---
I
I
GRg�AT
RoM
I
I
I
Center Registers
169 CFM on ceiling fan 169 CFM
IOXIOXi I O)IOX7
--
DINING
ROOM
11
232 CFM
12xdxl
W
A' I
?OA20
I CTI
I
1I6"
I
I
LJ6- _
SECOND
BEDROOM
12xl2xa
/ I
B/A
ICJ
12"
143 CFM
IOxIox4
MASTER
BEDROOM
143 CFM
IOxloxd
2xl2x9
B/A
r a r a
ICJ r' ICJ
12x12x9
LOSET B/A
- 8 CF
Z
i
-T
i 34 M
I
/
`o
I
KII
153 CFM
12x12x1
F-h�
a
W i
I
LU ' ----
> I 1��I
p Attic ccess
e th light
t �'�J
COVERED
PORCH
®= JUNCTION BOX TO SUPPORT A FAN � � C � � � f C � L L � C � T
O = THERMOSTAT LOCATION Y
B/A = BALANCED AiR
Electric Notes: SCALE: 1/4" = 1'-0"
I.
2.
Use copper were onlg, no aluminum.
Provide and wire all required smoke detectors.
11. It is not the intent of these plans to show ever minor detail
3.
Contractor to verify location of electrical
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
4.
service and provider.
ALL paddle fans shall be on a rheostat.
the requirements necessary for the equipment to be placed in
S.
ALL bath and kitchen receptacles to be GFI protected.
proper working order.
18, All work shall be done in accordance with the N.E.C. and
6.
L
ALL exterior outlets to be WP/GFI protected.
Recessed cans to be installed per NFPA requirements.
shall comply with all local codes and ordinances, and shall
8.
AFCI receptacles are required in all rooms except
meet all standard requirements of the local electric utility
Kitchen, Bathrooms, and Garage.
and telephone company.
9.
10.
A/C Return Air Balance Must comply w/ FBC RM1602
A/C RefrigBrant lines that are run thru slabs must be
9. The electrical s stem shall be coin letel and effective)
sleeved in PVC
ev
rounded as required b the latest edition of the N.E.C.
9 q y
11.
ALL A/C Equipment shall comply with energy calculation
20. All material shall be new and shall bear underwriters'
12.
All work shall be performed bg a licensed electrical
labels where applicable.
contractor, the completed system shall be fullg operative.
13.
Contractor shall pay for all fees, permits, testing, and
21. All equipment and panel sizes shall be verified before
inspections including blower testing where required,
ordering. The contractor shall provide circuit routings to
14,
All work shall be coordinated with other trades to avoid
suit the job conditions.
interference with the progress of construction.
15.
All required insurance shall be provided for protection
22. Furnish and install all fixtures as called for on the plans
against the public liability and property damage for the
or as selected bg others.
duration of the work.
16.
Contractor shall guarantee all materials and workmanship
23. All raceways and pipes placed in or through any concrete
free of defects for a period of not less than two years from
slab shall be spaced a minimum of three diameters of the
the date of acceptance or certificate of occupancy, or one
largest conduit or pipe from any other service.
year from closing sale of house.
Correction of defects shall be completed without additional
24. All exposed wire below 9'-I" shall be Installed in metal EIIT
charge and shall include replacements or repair of any
conduit.
other phase of installation that may have been dfimaged.
25. Dryer Vents to be installed per FBC RM1502
H.B
--- Vent-thru
Soffit
150 Amp Panel Id kMeter
GARAGE
I r----------------- i
I I
I I
I I
I I
I I
I I
I I
I I
I I
I
I I
A/C disc.
Go
it2/0 Aluminum feed
AMP
1 i/a° Conduit PCB
ANEL
f
AHu
2" PVC ( FPL
2" rigid service FPL Bare #4 copper
wirer in slab
r to
ELECTRICAL RISER
- Contractor shall use AL-CU Landing lugs. NITS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
Braden t
Braden AIA, PA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
: (112) 281-8258
Fax
: (112) 281-8283
E-mail:
bradenaias'comcaSt. net
Stuart, FL
34994 UAAC000032
H.B.
Exhaust Duct
Thru Soffit -
Wire For
Front Post
Light
PATIO/SLAB
E L E CT21CAL F_:N
W p
3::6�Post Light with
I Photo cell
Wgnne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
Install oulet
under disc.
t shown for
clarity
SCALE: 1/4" = 1'-0"
Attic Venting Calculations FBC 2309.1
Total Attic Space = 212� sq, ft.
Venting Ratio 1/150 = 14.16 sq. ft, required
Provide A Continuous Vented Soffit
MODEL: Date Drawn Revisions Sheet Comm #
GARAGE f)rawn rawn�
RIGHT by:
Q .C.U. E -1 12-27
Checked bg:
L.R.B. OF 5