HomeMy WebLinkAboutEPL Display CardFORM R405-2014
- ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows- Description
a. U-Factor: Dbl, U=0.54
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.25
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
WYNNE DEVELOPMENT, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1.
1250.00 ftz
b. Frame - Wood, Exterior
R=11.0
187.33 ft
1
c. N/A
R=
ftz
2
d. N/A
R=
ftz
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1446.00 ftZ
1446
b. N/A
R=
ft2
c. N/A
R=
ftz
Area
11. Ducts
R ftz
99.23 ftz
a. Sup: Attic, Ret: Attic, AH: Attic
6 320
40.00 ftz
12. Cooling systems
kBtu/hr
Efficiency
ftz
a. Central Unit
34.8 SEER:15.00
Insulation
R=0.0
R=
R=
ftz
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
34.8 HSPF:8.50
3.586 ft.
0.250
Area
14. Hot water systems
1446.00 ft z
a. Electric
Cap: 40 gallons
EF: 0.9.7
ftz
b. Conservation features
ftz
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building 4,�KE.gT
Construction through the above energy saving features which will be installed (or exceeded) .yo 80
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: �p �� �� o-i',�p- a�
Address of New Home: �a� l�c� S City/FL Zip:
r- op WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/31/2017 12:22 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1