Loading...
HomeMy WebLinkAboutProject InformationJob: wrightsoft° Project Summary Date: Enure House By: QUICK CALCS, INC. 317 St..LUCIE LN., FT. PI FL 34946 Phone: 771466$799 Fax Email: OU10KCALCS9A0L.0 OM. For. THE GRAND.CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: Design Information Weather: Winter.Design-Conditions Outside db 42 OF Inside db 70. OF Design TD 28 OF Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 . Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 He 1446 Cool'46 Area ft Volume (ft3) 12511 12511 Air changeslhour 0.45 0.23 Equiv. AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A" 030 AHRI ref 7914585 Efficiency Heating 'input Heating output Temperature rise Actual air flow Airflow factor Static pressure Space thermostat Capacity balance point = 32 OF Backup: 8.5 HSPF 34600 ,Btuh @ 47°F 27 OF 1160 cfm . 0.049. cfm/Btuh 0.50 in H2O Input = 7 kW, Output 23009 Btuh, 100 AFUE Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 dfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Ratelswing multiplier 0.95 Equipment sensible load 24753 Btuh Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh (none). Equipment -latent load 5521 Btuh Equipment total load 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load. sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft` 2017-Apr-11 09:29:38 ACC Right -Suite® Universal 2.017 17.0.14 RSU08101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N + wA4htsoft- Right-M Workshieet Job: Enike House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772A66-6796 Email: QUICKCALCS@,AOL.COM 1 Room name Entire House BEDROOM 2 E)qmed wall 166.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heal/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2 Ty Construction LI-value Or HTM Area (ft-) Load Area (ft2) Load number (Btuh1ft2 °F) (BtutVft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat cool Gross N/P/S Heat cool Gross N/PIS Heat Cool 6 48AAc6s, ,14 00. :2 65 -50 *5 -�1184 72 -72 - - - - .286 .183 0. 770 815 730: 0:.-. 1.: - .7. :0 - •'-o 13AAocs 0.143 e 4.00 2.55 128 83 333 212 6 0 0 0 1A-tom 1270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 11DO 0:390 e 10.92 11.31 21 21 229 238 0 0 0 0 VV .13A4ocs 0:143 se 4.00 2.55 .34 34 136 86 0 0. -0 0 t-G 13A4ocs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 650 1A-clorn 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 VAt -i� 134446cs -0.143 w' 4.00 '2.55 310 237 949 609 104 .72 :288 183 1.270 w 3.6A 55�21 '32 2- 1140- 17-70- 32 2 1140 177.0. r' -4 b.-7�6"W .41 All 880' 788 D - A 0 13 12 C -Osw 0.09 1 2.55 1.28 192 192 489 246 0 0 0 0 :C:- A�Qbmd M q)7 * 03� 496 ;'Z32::�� I _ -1446 , _ -1446 1295 -.3354 ':,-297 - 267 689, F. 22A-tpl 0.989 27.69 % - 0.00 1446 156 4325 0 297 49 .-266 1357 0 6 c)AED emursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 6 13801 3 .690 Appliances/other 2000 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less e)demal load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 2.3503 26056 66M 7325 Air required (cfm) 11601 11601 328 326 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. RigWSu lte@-) Universal 201117.0.14 RSU08101- .2017-Apr-11 09:29:38 Page 1 uIck CalcskDocuments\THE GRAND CARLTON-1446.rup* CaIc.= MJ8 Front Door fades: N J. 1- wrightsoft° RighW@ Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM Job: Date: By: 1 Room name WIC KITCHEN 2 3 Exposed wall Room height O ft 8.0 ft heat/cool O ft 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 9.0 ft 64.0 ft2 1.0 x 1720 ft 172.0 ft2 Ty Construction number U-value (Btuhlft2-'F). Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) . Area (ft2) or perimeter. (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NMS Heat Cool 6 13A4ocs 13AAocs 0.143 0.143 n` a 4 U0' 4.00. 255 2.55 0 0 :. 0 0 0 0 0 0 0 0 ':. 0 ' 0 0 '0 ' ' .10.. 0 0 ;0 0 0 11 0 11 `D W': U)1 �--G IA-clom 11D0 A:1 k4ocs, 13A-4ocs 1A-clom 1.270 0.390 0%.143 0.143 1.270 a a . se . s s 35.56 10.92 4.00 4.00 35.56 87.29 11.31 2:55 2.55 34.77 0 0 ' 0 0 0 0 0 :0 0 0 0 0 . , 0.1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 : 0 0 0 0 0 . 0 0 0 0 0 0 0 0 13A-0ocs IA-c1om 4A5-2om : 12C-0sw 16A 30mtla ,. 22A tpl 0.143 1.270' 0.770 0.091 .032 0.989 ' iv" . w w - , ;- . - 4:00 35.56 21 % 2 55 0:90' 27.69 2.55 55.21. 19.31" 1.28 232 0.00 . 0 0 0 0 ,54 54 --0 0 :: 0 0 .: ` - 5q 0 0 0- 0 0 0 0 0 :. .0 0 125 0 0 0 0 64 :..' 172 172 0 p . U 64 ; ; . 772 . 0 A 0 . , 0 163 ..:. ..y54 0 0 0 0 82 ; . •..:39,9 0 —G P C F 6 c)AED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a)' Infiltration 0 6 0 0 b) 'Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 49% 15 57 32% 49% 100 1126 Total room load 64 174 418 3437 Air required(cfm)' 31 8 21 153 AMA wrightSOf#' . Right -Suite® Universal 2017 17.0.14 RSU08101 ...uick Calcs%DocumentslTHE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N 2017-Apr-11 09:29:38 Page 2 wrightsok RighW@ Worksheet • Entire House QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-166-6796 Email: QUICKCALCS AOL.COM Job: Date: By: 1 Room name BATH BEDROOM 2 2 E(posed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heaUcool 8.0 ft heat/cool 4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft 5 Room area 45.0 ft2 203.5 ft2. Ty Construction U-value Or HTM Area (ft2) Load Area . (ft2) Load number (Btuh/ft2i-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter . (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coal 6 13A flocs Z : 0143 rt " 4 00 2 55 40 40 . 160 902 128 ;: 128 513 i326 4A5 tom, i . 0 770 , rn.. 27:5fi 19,31' 0 0 ; l3 0 ` 0 . 13A4ocs 0.143 a 4.00 2.55 0 0 0 0 80 56 225 143 -G 1Ac1om 1.270 a 35.56 87.29 0 0 0 0 24 2. 848 2082 1 11DO 0.390 a 10.92 11.31. 0 0 0 0 0 0 0 0 W _ . 13A4acs 0:143 ` se 4.00 2:55 0 0 0 '. 0 - 34 34 136 86 V�I I-G 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A46cs 0.M w 400. Z55 0 0 0 0. 0' 0. 0 0 . A-c1om 1270 w 35 56; 55.21 0 0 0 0 0 0 4A5 tom 0:770 . w: 21 56. 19.3,1: ' 0 0 .. 0: 0 ` . Q 0 ... p ., 0: P 12C-0sw 0,091. - 2.55 1.28. 0 0 0 0 0 .:. 0_ 0 0 C 76A 30md- .. 0:032 =;-.. ..0.90 2,32 :. 45 _ . , ` . .`:45 : -: _ 40 104 ; .` ., .404 204 : :;182 472 F 22Atpl 0.989 - 27.69 0.cb 45 5 138 ., 0 204 34 946 0 6 c)AED excursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . 67 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 01 0 Subtotal (lines 6 to 13) 425 214 3571 3498 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 ' 0 0 0 14 .Subtotal 425 214 3571 3498 15 Duct loads 32%1 490/( 135 104 321/6 49% 1131 1704 Total room load I560 318 4702 5203 Air required (cfm) 28 14 232 232 Calculations approved byACCA to meet all requirements of. Manual J 8th Ed. . -�- wrightsoft� 2017-Apr-11 09:29:38 �LrA Right;suite® Universa1.2017 17.0.14 RSU08101 Page 3 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - wrightsoft' RighWO Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS , OLCOM 1 Room name LAUNDRY GREAT/DINING 2 =ed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 5 Room area 42.0 ft2 526.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area . (ftq Load number (Btuh/ft' °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 :V�/ 18A46cs • 0143 n :" 4 00 2;55 ;0 U 0 0 , :. 255 217 " 868 552 �C- 4A5 tom 0:770 . n :. 21:56 19,31 0 0 0 "" ' 0 38 • ' 0 815 730. L_GG 13A-4ocs 0.143 a 4.00 . 2.55 0 0 0 0 0 .0 0 0 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 `_W '.13A4ocs 0143 " se 4:00 2.55 0 0 0 0 0 ' 0 ' -0 0 V1J 13A4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 L-G 1Ao1om 1.270 s 35.66 34.77 0 0 0 0 0 0 0 0 yJ 13M= 0.143 w 4.00 2.55 0 0 0 0 206 165 661 420 1Ac1om 1 270 35 56 55 21 0 0 0 9A52om ".:. p770 ..0770j. w , , 21.56; 19.31 0 0 0 " 0 ;:. 0 4T .., .. p 41 . : ,0 880 .:0. :. 788 P 12C-0sw 0.091 - 2.55, 1.28 56 56 143 72 0 0 0 -, 0 C _ .:.16A 30md:. 0:032 °- 090 2:32 _ 42 ` : 42 _ :.. 38 : 97 : ;..: 526 _ - ; , . 526 .1220.' F 22A tpI 0.989 - 27.69 0.00 42 6 166 0 526. 47 1302 0 6 c)AED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 1 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 643 298 5994 5112 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 1 32% 49% 204 145 32% 49% 1899 2490 Total room load 846 443 7892 7602 Air required (cfm) 42 20 390 338 .Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. - wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 4 uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJB Front Door faces: N Wr ghtsoft- Right-JO Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER M. BATH 2 3 F�gwsed wall Room height 7.0 ft 8.0 ft heat/cool 8.0 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 50.0 ft 50.0 ft2 7.0 x 8.0 ft 56.0 ft2 Ty Construction number U-value Btuh/ft2-°F ( ) Or HTM (Btuhlft2) Area (ft)2 or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 N '13A- ocs . 13AAocs 0143 0.143 m : n,... a 4.00 2156 4.00 "2.55 19.31 255 8 =` 0 48 8 0 27 32 : '. 0 108 20 .0 69 0 0 0 0 ::: 0 0 :- 0 : p 0 :0 0 0 ..4A5 1 W W 1A-clom 11DO 1`13AAocs 13AAocs 1.270 0.390 0.143 0.143 a a se s 35.56 10.92 4.00 4.00 87.29 11.31 '2.55 2.55 0 21 0 0 0 21 0 0 0 229 . 0 0 0 238 . 0 0 0 0 0 64 0 0 0 57 0 0 . 0 226 0 0 0 145 1A-clom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 13AAocs 0.143 w 400 2.55 0 0 0 0 0 0 .0 0. 1A c1om - . 1.270 w ' 35.56 55:21 0 0 0 0 0 .0 0 • 0. 4A52om.. ;0:770 , .w;=' 2156 1931 0 . 0 :". 0 . , 0 ' " . 0:•' 0 ,0 0. P, 12C-0sw. 0.091. 2.55. 1.28 72 72 183 92 0 0 0 0 C 16A 30. dd . 0:032 .- .: -= Oi90 2 32 , 50 50 ' " ". 45 `. 116 " . 58 _ 55 50 :" -130. F 22A tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 " 222 0 6 c)AED excursion -39 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 913 529 885 516 Less extemal load 0 0 0 0 Less transfer 0. 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 1 32% 49% 289 258 32% 49% 280 251 Total room load F71202 781 1166 768 Air required (cfm) 59 35 58 34 Calculations approved byACCA to meet all requirements of Manual .J 8th Ed. EGA - wrightsoft- Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 5 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N *wrights.oift° Duct.System summalry Jae. Entire House By: QUICK CALCS,INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466.6799. Fax 772466-6796. Email: QUICKCALCS AOL.COM a For: THE GRAND CARLTON WYNNE DEVELOPMENT,. FT. PIERCE, FL External static pressure Pressure losses Available.static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating. 0.50 in H2O 0 in H2O .0.50 ,in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 _ 28 14 0.364 4.0 Ox0 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox 0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505_ 4.0 OxO VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8. 135.0 st2 GREAT/DINING-A h .3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox0 VIFx 17.0 115.0 SO LAUNDRY h 846 42 20 0.361° 4.0 Ox0 VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox 0 VIFx 0 0 wic c 174 3 8 0.309 4.0 Ox 0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 - 918 12.0 0 x 0 'VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx 9 wri htsoftg Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-1109:29:38Page 1 �'� ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Name Grille Size (in) Htg (cfm) Clg . (cfm) TEL (ft) Design FR Veloc (fpm). Diam. (in) . H x W (in) . Stud/Jdst . Opening (in) Duct Matl Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx wrightsoft@ :Right-Suite®'Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38Page 2 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N