HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONST UCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: THE GRAND CARLTON
Builder Name: WYNNE DEVELOPME"File dopy
Street: WYNNE DEVELOPMENT
Permit Office: ST. LUCIE COUNTY �31''
11��
City, State, Zip: FT. PIERCE, FL ,
Owner: \ 6 : �\ � �Jr- nCA
Permit Number:
Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1437.3 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 I 1250.00 ft2
b. Frame - Wood, Exterior
R=11.0 187.33 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1446.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30. 1446.00 ft
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(139.2 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 320
a. U-Factor: Dbl, U=0.54 99.23 ft2
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.55 40.00 ft2
12. Cooling systems
kBt /hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
? SHGC:
13. Heating systems
kB u/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
` Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1446.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1446.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 46.91
SS PASc
Total Baseline Loads: 48.19
I
I hereby certify that the plans and specifications covered by
Review of the plans and114E
S7,q?,
this calculation are in compliance with the Florida Energy
specifications covered by this
,y� __
Code.
calculation indicates compliance
with the Florida Energy Code.
Will
PREPARED BY:
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I0
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
c�D
with the Florida Energy Code.
yyB'1��
OWNER/AG T' A
BUILDING OFFICIAL:
DATE: LA
DATE:
I
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure! qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1 A and an envelope leakage
test report in accordance with R402.4.1.2.
6/16/2017 11:49 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
I
PROJECT
I
Title: THE GRAND CARLTON
Bedrooms: 2
Address Type:
Stree Address
Building Type: User
Conditioned Area: 1446
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT
Rotate Angle: 135
Street:
WYNNE DEVELOPME
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
ST. LIUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. IERCE ,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
I
/
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location TMY
Site Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39
90
70
75
299
I 58
Medium
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
I
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID
Finisheld Cooled
Heated
1 BEDROOM 234
1872 No
2
1
1
Yes
Yes
Yes
2 WIC 54
432 No
0
1
No
Yes
Yes
3 MASTER BATH 63
504 No
0
1
Yes
Yes
Yes
4 M.BATH 56
448 No
0
1
Yes
Yes
Yes
5 KITCHEN 172
1376 Yes
0
1
No
Yes
Yes
6 BATH 45
360 No
0
1
Yes
Yes
Yes
7 BEDROOM 2 204
1632 No
1
1
1
Yes
Yes
Yes
8 LAUNDRY 42
336 No
0
1
Yes
Yes
Yes
9 GREAT/DINING 526
4208 No
0
1
Yes
Yes
Yes
10 FOYER 50
400 No
0
1
Yes
Yes
Yes
FLOORS
I
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 40 ft 0
234 ftZ
----
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
54 ftz
----
0 1
0
3SIab-On-Grade Edge Insulatio MASTER BATH 9 ft 0
63 ftz
----
0 1
0
4 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
172 ftZ
----
0 1
0
6 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ftZ
----
0 1
0
7 Slab -On -Grade Edge Insulatio
BEDROOM 2 34.2 ft 0
204 ftz
----
0 1
0
6/16/2017 11:49 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM. R405-2014
FLOORS .
I
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 47 ft
0
526 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio FOYER 7 ft
0
50 ft2
----
0
1
0
ROOF
I
V
Roof
Gable
Roof
Solar SA Emitt
Emitt
Deck
Pitch
#
Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1
Gable or shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1446 ft2
N
N
CEILING
I
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Fra4 Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
234 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
54 ft2
0.1
Wood
3
Under Attic (Vented) MASTER BATH
30
Blown
63 ft2
0.1
Wood
4
Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
5
Under Attic (Vented) KITCHEN
30
Blown
172 ft2
0.1
Wood
6
Under Attic (Vented) BATH
30
Blown
-
45 ft2
0.1
Wood
7
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
'
9
Under Attic (Vented) GREAT/DINING
30
Blown
526 ft2
0.1
Wood
10
Under Attic (Vented) FOYER
30
Blown
50 ft2
0.1
Wood
WALLS
I
Adjacent Cavity Width
Height
Sheathingfile
raming
Solar
Below
f7irnt
Space
To Wall T4PP1
Et In
Et
In
Area
R-Nlahle
N=>SE
Exterior Concrete Block - Ext InsiHEDROOM
4.1 9
0 8
0
72.0 ft2.
0
0
0.5
0
_ 2
S=>NW
Exterior Concrete Block - Ext InsBEDROOM
4.1 18
0 8
0
144.0 ft2
0
0
0.5
0
3
W=>NE
Exterior Concrete Block - Ext InsfilEDROOM
4.1 13
0 8
0
104.0 ft2
0
0
0.5
0
4
S=>NW
Exterior Concrete Block - Ext In9MWSTER BA
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
5
S=>NW
Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
6
N=>SE
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.5
0
7
N=>SE
Exterior Concrete Block - Ext InSEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
8
E=>SW
Exterior Concrete Block - Ext InRffDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.5
0
9
SE=>W
Exterior Concrete Block - Ext IndIEDR00M 2
4.1 4
3 8
0
34.0 ft2
0
0
0.5
0
10
S=>NW
Exterior Concrete Block - Ext Ind3ffDROOM 2
4.1 4
0 8
0
32.0 ft2
0
0
0.5
0
11
S=>NW
Exterior Concrete Block - Ext InsillAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.5
0
12
N=>SE
Exterior Concrete Block - Ext InsGiREAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.5
0
5/31/2017 12:22 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WALLS
Adjacent Cavity Width
SpaceR_VahJPEt
Height
Sheathing Framing Solar
R-Vahle
Snr13
Below
W=>NE Exterior Concrete Block - Ext InsGREAT/DINT 4.1 21 0 8
14 N=>SE Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8
15 E=>SW Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 8
16 N=>SE Exterior . Frame - Wood GREAT/DIN[ 11 23 5 8
0 168.0 ft2
0 8.0 ft2
0 48.0 ft2
187.3 ft2
0 0 0.5
0 0 0.5
0 0 0.5
0.23 0.5
0
0
0
0
DOORS
# Ornt Door Type Space
Storms
U-Value Width Height
Ft In Ft In
Area
1 E=>SW Insulated FOYER
None
.28 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
v # Ornt ID Frame Panes NFRC
U-Factor SHGC
Overhang
Area Depth Separation Int Shade
Screening
1 W=>NE 3 Metal Low-E Double Yes
2 S=>NW 5 Metal Low-E Double Yes
3 E=>SW 8 Metal Low-E Double Yes
4 N=>SE 12 Metal Low-E Double Yes
5 W=>NE 13 Metal Low-E Double Yes
0.54 0.25
0.54 0.25
0.54 0.25
0.54 0.25
0.55 0.25
32.4 ft2 1 ft 0 in
6.9 ft2 1 ft 0 in
23.2 ft2 1 ft 0 in
36.8 ft2 1 ft 0 in
40.0 ft2 10 ft 0 in
1 ft 4 in Drapes/blinds
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
Exterior 5
None
None
None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 315ft2 315ft2
24ft
8ft
11
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2455
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit Split
SEER: 15 34.8 kBtu/hr
cfm 0.85 1
sys#1
5/31/2017 12:22 PM EnergyGaugeg) USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
HOT WATER SYSTEM
System Type
F1-1
SubType
Location
EF Cap Use
SetPnt
Conservation
Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model # Area
Volume
FEF
None
None
ft2
DUCTS
--- Supply —
- - Return ---
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 320 ftz
Attic
80 ftz Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
- Programable Thermostat: Y
Ceiling Fans:Cooling
Jan
H
Feb
H
Mar
Apr
My XJun Jul
rj
Aug
rj
rj Sep
Oct
[ ]Vent
Lt
Nov.
N
Dec
H Dec
Jan
Feb
txl Mar
Apr
May lJun Jul
Aug
Sep
lxl Oct
Nov
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5. 6
7
8
9
.10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
5/31/2017 12:22 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
17077iila, 1L8FKITIV,
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawispace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
6/16/2017 11:54 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1