HomeMy WebLinkAboutNOA NOA No.: 17-0606.03
Expiration Date: 06/22/22
Approval Date: 06/22/17
Page 1 of 3
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Franklin International.
2020 Bruck St.
Columbus, OH. 43207
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purp oses. If this product
or material fails to perform in the accepted manner, the manufacturer will incur the expense of such
testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material
within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Titebond WeatherMaster Ultimate MP Sealant,
Titebond WeatherMaster Metal Roof Sealant.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this
NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 3.
The submitted documentation was reviewed by Freddy Semino.
NOA No.: 17-0606.03
Expiration Date: 06/22/22
Approval Date: 06/22/17
Page 2 of 3
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Cement-Adhesive-Coatings
Materials: Silane Terminated Polyether
SCOPE:
This approves Titebond WeatherMaster Ultimate MP Sealant, and Titebond WeatherMaster Metal
Roof Sealant as manufactured by Franklin International as described in this Notice of Acceptance. This
product has been designed to comply with the Florida Building Code, including the High Velocity
Hurricane Zone of the Florida Building Code.
PRODUCT DESCRIPTION:
Titebond WeatherMaster Ultimate MP Sealant, and Titebond WeatherMaster Metal Roof Sealant
Property Standard Results
Tensile Strength @ 73º ASTM D412 285.43 psi
Elongation @ 73º ASTM D412 550.09%
Modulus of Elongation ASTM D412 123.54 psi
Tear Strength ASTM D624 51.83 pli
Adhesion Peel ASTM C794 29.71–39.49 pli
Hardness (Shore A) ASTM C661 38.8
UV Resistance ASTM C793 Pass
Note: The physical properties listed above are presented at typical average values as determined
by accepted ASTM test methods and are subject to normal manufacturing variation.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Specification Date
RCMA GROUP RCMA-160137 TAS 132 04/12/17
MANUFACTURING LOCATION:
1. Columbus, Ohio
BUILDING PERMIT REQUIREMENTS:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable Building Code in order to
properly evaluate the installation of this system.
NOA No.: 17-0606.03
Expiration Date: 06/22/22
Approval Date: 06/22/17
Page 3 of 3
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire rating of this product.
2. Titebond WeatherMaster Ultimate MP Sealant, and Titebond WeatherMaster Metal Roof Sealant
shall not be applied in inclement weather conditions.
3. The products listed herein are components of roof assemblies and are approved for use with roof
assemblies that list the products listed herein as part of their roof assemblies Notice of Acceptance.
See roof system Notice of Acceptance (NOA) for application rates and uses.
4. All products listed herein shall have an unannounced follow-up quality control program from an
approved listing agency. Follow up test results shall be made available to Miami-Dade County
Product Control upon request.
5. Change in materials, use, or manufacture of any products listed herein shall be cause for termination
of this Notice of Acceptance.
6. Titebond WeatherMaster Ultimate MP Sealant, and Titebond WeatherMaster Metal Roof Sealant
shall be applied in accordance with manufacturer’s published application instructions unless
specified otherwise within the NOA approvals.
7. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61G20-3 of the Florida Administrative Code.
8. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear the
imprint or identifiable marking of the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product
Control Seal as shown below.
END OF THIS ACCEPTANCE