HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFBCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
b
a
Product Approval
P
USER: Public User
Product Approval Menu > Application Detail
FL # FL17796-R2
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Atlantic Metal II of Vero Beach, Inc.
Address/Phone/Email 4310 45th Street
Vero Beach, FL 32967
f772) 257-5730
Kim.lasky@atlanticmetal2.com
Authorized Signature Kimberly Lasky
Kim.lasky@atlanticmetal2.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed David Eng
the Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 06/11/2025
Validated By James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL17796 R2 CCI_24ga 1.5 Nailstri� p»y od.odf
Standard
Year
TAS 100
1995
TAS 125
2003
UL 580
2006
jvvviv;.floridahuiidinq.orgiPrlPr_aPp_del.aspx?param-vfGEV--- ",2bbt231iiLSHoiIKv7zYVGsdnivgNcviv79awg.JHDssgog7.- 3d9;,3d
Sections from the Code
Product Approval Method Method 1 Option 0
Date Submitted
10/06/2020
Date Validated
10/15/2020
Date Pending FBC Approval
10/25/2020
Date Approved
12/15/2020
Summary of Products
FL # Model, Number or Name
17796.1 01: 24ga 1.5" Nail Strip over
Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116
Other: Refer to evaluation report
17796.2 02: 24ga 1.5" Snap Lock over
Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116
Other: Refer to evaluation report
Description
24ga (min) 1.5" nail strip standing seam panel over 15/32
(min) plywood
Installation Instructions
11_5s iyod.o1—ldf _
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17796_R2_AE_24aa 1_5_Nailstrip_pi.ywood.pdf
Created by Independent Third Party: Yes
24ga (min) 1.5" snap lock standing seam panel over 15/32"
(min) plywood
Installation Instructions
EL17796 B2_I_I_24ga_1 5 S, napLock_plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17796_R2_AE_2Aga_i_5_Sna L c _plywood.p�f
Created by Independent Third Party: Yes
17796.3 i 03: 032 Aluminum 1" Mechanical Nominally 0.032" aluminum (or thicker) 1" mechanical lock
I Lock on Plywood standing seam panel on 15/32" (min) plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL17796 R2_1:1_032_1 Q_Mechanical_plywood.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-101 Evaluation Reports
Other: Refer to evaluation report FL17796_R2_AE_CCU?_1.0_Mechanical_plyEgod.pdf
Created by Independent Third Party: Yes
17796.4 04: 24ga 1.0" Nail Strip on Plywool 24ga (min) 1.0" nail strip standing seam panel over 15/32"
\_ (min) plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +N/A/-153.5
Other: Refer to evaluation report
17796.5 05: 24ga 1.0" Snap Lock over
Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131
Other: Refer to evaluation report
17796.6 06: 26ga 5V Crimp on Plywood
i FL17796_R2_II_24ga_1_0_ ailst ip_plywood_nonHVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL17796_R2_AE_�4g�_7�. _Nailstrio pl w o nonHVHZ.odf
Created by Independent Third Party: Yes
24ga (min) 1.0" snap lock standing seam panel over 15/32"
(min) plywood
Installation Instructions
FL17796_R_II_24ga_1.Q. of _SnapLock—plywoodf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports j
FL17796_R2 AE_24ga_1_0_SrapLcck_plywood.odf
Created by Independent Third Party: Yes
26ga (min) 5V Crimp exposed fastener panel on 15/32" (min)
plywood
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param-wGEV_.°/2bbt23mL8HofjKv7zYVGsdnivgNcyly79aw9JHDssgpg%3d%3d 2/23/22, 2:24 PM
Page 2 of 3
24ga 1.0" Nail Strip
24 gauge (min) 16" Nail Strip over 15/32" plywood
Florida Product Approval Number 17796.04-R2
Manufacturer:
Atlantic Metal II of Vero Beach, Inc
4310 45th Street, Vero Beach, FL
www.atianticmetal2.com
(772) 257-5730
A T, r1A
T
ETAL
of Vero Beach, Inc.
�T r
k,
Metal Roofing Panels - Metal Roofing
Accessories • Custom Metal Fabrication
Product: Nail strip standing seam panel with nominal rib height of 1.0" and max panel width of 16".
Material: 24ga or thicker steel with yield strength of at least 50ksi, and corrosion resistance per FBC
1507.4.3.
Fastener: #10 x 1 " pancake -style fastener, compliant with FBC 1506.6
Substrate/Deck: Minimum 15/32" thick plywood.
Underlayment: Comply with FBC 1507.1.1 where required.
Slope: Comply with FBC 1507.4.2 where required.
Will
ax_A1tovvabfe,-E•oads & Installation Requirements:
Method A: 59.75psf I InstJ (1) #10 x 1" fastener in panel slot at 16"
O.C.
Method B: 101 psf I Install (1) #10 x 1 " fastener in panel slot at 6.75"
o.c
Method C: 153.5psf I Install (1) #10 x 1"fastener in panel slot at
6.75" o.c AND (2) #10x1" eclipse head fastener in pan of panel at
12" o.c.
Factor of Safety of 2.0 applied to calculate allowable loads.
Compliance statement: This product as described has demonstrated compliance with Florida Building
Code 2020, Section 1504.3.2 (non-HVHZ), as required by Rule 61 G20-3, method 1 D
Evaluated By:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ. Ave # 206, Gainesville FL 32607
PE Lic. No: 81377
E. F �.,%
David E Eng
2020,10.07 - No.81377 =_
00:22:54+01'00' * ;
CA Lic. No: 33344 This item has been digitally signed and �3� W
Wvvw. FimberLakeCove.com sealed by D.E Eng; PE. on the date ' STATE OF <41
indicated Printed copies of this document �'�� '•..FCORIOP. ' \G���
are not considered signed and sealed and , ts, \ �\
the signature
must be verified on any ��iies �� �`
ONAL � ���\
TUAWI
.TL
Technical Documentation: of Vero Beach, Inc.
This product has been tested to the UL 580 standard by Force Engineering
(TST-5328), report 72-0314T-06. As referenced in FL 17796.04-R1
Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor
will acquire a financial interest in any company manufacturing or distributing products under
this evaluation. The same entities do not have, nor will acquire, a financial interest in any
other entity involved in the approval process of the product.
Exclusions & Limitations: Design of deck and roof structure (to include deck attachment)
shall be completed by others. Fire classification and shear diaphragm design are outside the
scope of this evaluation. Accelerated weathering/salt spray is outside the scope of this
evaluation. Installation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2,
as required by Rule 61 G20-3. Neither Timberlake Cove nor the manufacturer shall be
responsible for any conclusions, interpretations, or designs made by others based on this
evaluation report. This report is limited solely to documenting compliance with Rule 61 G20-
3, and makes no express or implied warranty regarding performance of this product.
Design Process: The load tables in this report provide several prescriptive options for the
r� fastening requirement for the applicable wind loads for roofs within the parameters
described. For roofs outside of the listed parameters, design wind loads shall be determined
as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress.
These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a site
location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction
Load Tables: NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tables
below, the worst case was taken for each zone and reported using the standard zones 1-2-3:
Zone 1 includes zones 1 and 1'
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple scheme, at the expense of some design
efficiency. Contact the manufacturer for further information, or consult a licensed design
professional.
Ih� 1.25" 1.25"--1
ff-410FASIENER
FFr•,1n YAPSONTO k ALL=G
#10 FASTENER
(TYP), 12" O C MAX
6 75" O C MAX
11
i
3\
2
13
a—
----
1
2
1
1
2
2 1 22
2
1
2
a r3
a
2
HE ROOF - GABLE ROOF
ETAS, H
of Vero Beach, Inc.
Instructions:
Select the appropriate load table that applies to the
structure in question.
Determine the design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
' + ?' OFLEAST HOIZONTALDIMENSION OR011,_WHICHEVERISSMALLER, BUT NOT See Note on previous page.
LESS THAN EITHER d'+; OF LEAST HORIZONTAL DIMENSION OR 3FT IO 9MI
OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE CODE
ROOF ZONES FOR GENERIC BUILDING
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
FL17796.04: 24 a 1.0 Nail Strip on 16/32" Plywood
FL17796.04: 24cia 1.0 Nail Strip on 16/32" Plywood
Wind 106
110
120
130
140
160 160
170 180
190 200
Wind 106
110 120
130 140 160
160
170 180
190 200
Zone 1: A
A
A
A
A
A A
A 13
B B
Zone 1: A
A A
A B 9
B
B C'
}.
Zone 2: A
A
A
A
A
B B
B B
C C
Zone 2:
;'. B
B S
C',
C N
R,
Zone 3: A
A
A
A
B
B B
B C
y C
Zone 3: B
B B
B C; 4 ;�
C
NR NR
NR INR.
Use this load table for structures which meet the following criteria:
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Are located in B, C, or D exposure area
Have either a flat roof less than 70, hip roof with
Have either a flat roof less than 7°, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less
Have a mean Roof Height of 30 feet or less
FL17796.04: 24 a 1.0 Nail Strip on 16/32" Plywood
FL17796.04: 24 a 1.0 Nail Stri2 on 16132" Plywood
Wind 106 110 120 130 140 160 160 170 180 190 200
Wind 106 110 120 130 140 160 160 170 180 190 200
Zone 1: A A A A A A a I' B'
Zone 1: A A A A A 6 B B B C
Zone 2: A A A A A A _ F, R
,Zone 2: A A A B B B C C N R
Zone 3: A A A A - J
one 3: A r° 8 C- C G mow: N
METHOD A METHOD
B METHOD C
—FEMALE LEG SNAPS
ONTO MALE LEG
T_V
#10FASTENER 16"OC i,'t,X.
FEMA__t , t SNAPS
ONTO MALE LEG
410 FASTENER 6 75" U C NIAX
V
NR: NOT RATED
CONSULT DESIGN
PROFESSIONAL AS NEEDED
1507.3.9 Flashing. At the juncture of the roof vertical surfaces, flashing and counterflashing
shall be provided in accordance with the manufacturer's installation instructions or the
recommendations of the FRSA/TRl 07320 Manual.
1507.4 Metal roof panels. The installation of metal roof panels shall comply with the provisions
of this section.
1507.4.1 Deck requirements. Metal roof panel roof coverings shall be applied to a solid or
closely fitted deck, except where the roof covering is specifically designed to be applied to
spaced supports.
1.507.4.2 Deck slope. Minimum slopes for metal roof panels shall comply with the following:
1. The minimum slope for lapped, nonsoldered seam metal roofs without applied lap sealant
shall be three units vertical in 12 units horizontal (257percent slope).
�. The minimum slope for lapped, nonsoldered seam metal roofs with applied lap sealant
s is I be one-half,,,,it vertical in 12 units horizontal (4-percent slope). Lap sealants shall be
applied in*accordancewith the approved manufacturer's installation instructions.
3. The minimum slope for standing seam of roof systems shall be one -quarter unit vertical
in 12 units horizontal (2-percent slope).
1 _507.4.3 Material standards. Metal -sheet roof covering systems that incorporate supporting
structural members shall be designed in accordance with Chapter 22. Metal -sheet roof coverings
installed over structural decking shall comply with Table 1507.4.3(1). The materials used for
metal -sheet roof coverings shall be naturally corrosion resistant or provided with corrosion
resistance in accordance with the standards and minimum thicknesses shown in Table
1507.4.3(2).
TABLE 1507.4.3(1) METAL ROOF COVERINGS
ROOF COVERINC.
STANDARD .APPLICATION
TYPE
STANDARD
RATUMICKNESS
Aluminum
AS FM 13 209
0.024 inch minimum thickness for roll -formed panels and 0.019 inch minimum
thickness for press -formed shingles.
Aluminum -zinc
AS'1'M A 792
0.013 inch mininutrn thicknes*. AL 50 (coated minimum application rate)
coated steel
Cold -rolled copper
AS I'M B 370
Minimum L 16 o'sq. ft. and 12 oz./sq. ft. high yield copper for metal -sheet roof
covering systems: 12 oz/sq. ft. for preformed metal shingle s%stems.
Copper
AS FM B 370
16 oz.-sq. ft. for metal -sheet roof -covering systems: 12 oz. sq. ft. for preformed
metal shingle systems.
Galvanized steel
AS I M A 653
0.013 inch minimum thickness. G-90 zinc-coate&.
Hard lead
2 lbs./sq. N.
Lead -coated copper
ASTM M B 101
Prepainted steel
AS'I M A 755