HomeMy WebLinkAboutEnergy Efficiency Codex He COPY
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING
CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE GRAND CARLTON 299
Builder Name: WYNNE DEVELOPMENT
Street: THE CARLTON 299
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: VX C_Q_Vo"-'mil
Jurisdiction:
Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ftz
b. Frame - Wood, Adjacent
R=11.0 192.00 ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1474.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1474.00 ftz
6. Conditioned floor area above grade (ftz) 1474
b. N/A
R= ftZ
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sgl, U=0.54 101.25 ftz
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallonsEF:
8. Floor Types (1473.5 sqft.) Insulation Area
0.970
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.42
PASS
Total Baseline Loads: 48.48
1 hereby certify that the plans and specifications covered by
Review of the plans and
j'ff1EST,q?,
this calculation are in compliance with the Florida Energy
specifications covered by this
�yQ�� '
Code.
calculation indicates compliance
�_
ri,, ��� -
with the Florida Energy Code.
PREPARED B
Before construction is completed
r `
DATE:
this building will be inspected for
�tkl ! a
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
COD WF
OWNER/ G T:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection
Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
4/3/2017 5:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
'Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1474
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street:
THE CARLTON
299
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1474 11792
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BEDROOM
329 2632 No
0
1
1 Yes
Yes
Yes
2 WIC
63 504 No
0
1 No
Yes
Yes
3 M.BATH
56 448 No
0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes
0
1 No
Yes
Yes
5 BATH
45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No
0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
329 ft2
____
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
____
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
____
0 1
0
4SIab-On-Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft2
_--_
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ft2
____
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 32.2 ft 0
203.5 ft2
____
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft2
____
0 1
0
4/3/2017 5:48 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FARM R405-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ftZ
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft
0
488 ftZ
----
0
1
0
ROOF
Roof
v
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1553 ft2
246 ftZ
Light
0.6
No
0.9
No
0
18.4
ATTIC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1474 ftZ
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
329 ftz
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ftZ
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ftz
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ftZ
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ftZ
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ftz
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ftZ
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ftZ
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ftZ
0.1
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing
Solar
Below
Space
Wall T�tpf-C)Ent ToPR_Va
1 NE=>SW Exterior Concrete Block - Ext InsdBEDROOM
4.1 10
0 8
0
80.0 ftZ
0
0
0.6
0
2 SW=>NE Exterior Concrete Block - Ext Insd3EDROOM
4.1 28
0 8
0
224.0 ftZ
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext InsdBEDROOM
4.1 14
0 8
0
112.0 ftZ
0
0
0.6
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ftZ
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ftZ
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext InREDROOM 2
4.1 16
0 8
0
128.0 ftZ
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext InEBEDROOM 2
4.1 10
0 8
0
80.0 ftZ
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext In-QffDROOM 2
4.1 4
3 8
0
34.0 ftZ
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2
4.1 2
0 8
0
16.0 ftZ
0
0
0.6
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ftZ
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ftZ
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InsLLAUNDRY
4.1 6
0 8
0
48.0 ftZ
0
0
0.6
0
13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI
4.1 26
0 8
0
208.0 ftZ
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1 20
0 8
0
160.0 ftZ
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ftZ
0.23
0.6
0
4/3/2017 5:48 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
DOORS
# Ornt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V # Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Area Depth Separation
Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
. Yes
Yes
0.54 0.25 32.9 ft2 1 ft 0 in 1 ft 4 in
0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in
0.54 0.25 24.0 ft2 6 ft 0 in 1 ft 4 in
0.54 0.25 37.5 ft2 1 ft 0 in 1 ft 4 in
0.55 0.25 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
315ft2
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .2598
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
None None
ft2
4/3/2017 5:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
DUCTS
V
---- Supply
--
---- Return ----
Air
CFM 25
CFM25
HVAC #
#
Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
325 ft2
Attic
85 ft2
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[
]Jan Feb
[ Mar
A r
j Ma
X Jun X Jul
Au
[X Se
[ ]Oct
[ ]Nov
Dec
HeatinX]
Jan XFeb
[X� Mar
f
Apr
] May
f Jun 4 Jul
AuE
rj
Sep
[ ]
Oct
[X] Nov
Dec
Ventin [
] Jan [ Feb
[X Mar
[X
A r [
] Ma
[ Jun [ Jul
Aug
Se
[X]
Oct
[X] Nov
[ Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
4/3/2017 5:48 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON 299 Builder Name: WYNNE DEVELOPMENT
Street: THE CARLTON 299 Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
I The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
FAnair barrier shall be installed on fireplace walls. Fireplaces shall have
eted doors