Project Information
i +-wriightsoft' Project Summary pat Entire House. By: QUICK.CALCS, INC. 317 ST.. LUCIE LN., FT. PIERCE, FL 34946 Phone: 77246"799 Fax 772.466-6796 For: WYNNE DEVELOPMENT, THE CARLTON 299, FT. PIERCE, FL \-'-z' �c csz\a Notes: Design • • Weather. Fort Pierce, FL, US .Winter Design Conditions Summer Design Conditions Outside db ' 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18188 Btuh Structure 17877 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh . Central vent (0 cfm) 0 Btuh none e) Humidification 0 Btuh Blower 0 Btuh . Piping 0 Btuh Equipment load 23842 Btuh Use manufacturer's data n Rate/swing multiplier Equipment 0.95 Infiltration sensible load 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh Heatingg coolin�gg (none) Area (ft2) 1474 1474 Equipment latent load 5277 Btuh Volume (W) 12227 12227 Air changes/hour 0.45 0.23 Equipment total load 30370 Btuh Equiv. AVF (cfm) 92 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 470F Latent cooling 10440 Btuh Temperature rise 27 °F Total cooling. 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static .pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 33 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations -approved byACCA to meet all requirements of Manual J 8th Ed. -- wrightsoft` 2017-Apr-10 17:14:53 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Cale = MJ8 Front Door faces: N - - wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS !AOL.COM 1 Room name Entire House BEDROOM 2 Bposed wall 156.2 ft 52.0 ft 3 Room height 8.3 ft d 8.0 ft heat/cool 4 . Room dimensions 1.0 x 329.0 ft 5 Room area 1473.5 ftz 329.0 W. Ty Construction U-value Or HTM Area (ft-) Load Area (ft.) Load number (Btuh/ft2L-°F) (Btu 1) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WKS Heat Cool ' 6 : 13A4ocs 0.143 ne; 4 06 ; 255: : 479 442 :1768 1124 80 80 320 204 1Ac1om- 1:270 ,ne 35:56' 70.43 ' 38 A 1344 ``2662 ' : " 0 . 0 : 0 0 W 13A-4ocs 0.143 se 4.00. 2.55 128 83 331 210 0 0 0 0 ;�Cp IA-c1om 1.270 se 35.56 34.77 24 48 848 829 0 0 0 0 11 11DO 0.390 se 10.92 11.31 22 22 236 244 0 0 0 0 W 13A4ocs 0143 s .4.00 2.55 34 '34 136 86 0 0.' 0 0 V�! 13AAocs 0.143 sw 4.00 255 360 353 1414 899 224 224 897 570 Y GC IA-c1om 1.270 sw 35.56 42.91 7 11 247 298 0 0 0 0 13AAocs 0.143 nw 4.00 255 290 217 867 551 112 79 .. 318 202 1A clom .1.270 ` nw 35.56 .. 4524 is - 33 , 0 1162 ' 1478 ': W0 .; 1162 1478 4A5 tom 0:770 ,nw 24:56 '; . 27.54 - - 41 .: 0 ..: -- 880 : 1124 0 . ... 0 : 0 '0 P 12C-0sw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 0 C . , ; .16A=30md 0:032 ;.: - . :, 0 90' 2:32 1474 1474 _ -A 320 : 3419 329 329 2.95, 763 F 22A-tpl 0.989 - 27.69 0.00 1474 156 4325 0 329 52 1440 0 6 c)AED excursion 784 680 Envelope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 2 460 Appliances/other 2000 0 Subtotal (lines 6 to 13) 18188 17877 5341 4606 Less aAemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18188 17877 5341 4606 15 Duct loads 31% 48% 5654.. 8536 31% 48% 1660 2199 Total room load 23842 26413 7001 6805 Air required (cfm) 1160 1160 341 299 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 1 ...Wrightsoft WAC%WYNNE-THE GRAND CARLTON-299.rup Cale = MJ8 . Front Door faces: N wrightsoft• RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 !=ad wall 0 ft 8.0 ft 3 Roam height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 ft 5 Room area 63.0 ft2 56.0 ft2 TY Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft;°F) (Btuh/ft2 ) ft or () (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat cool Gross WP/S Heat Cool 6 V►/ 13A4ocs, 0:143 ne`_' 4 0d 2 55 = 0 0 0 • .. .0 O r : 0 0 0' L-C( 1Ac1om :1.270 `-ne 35.56 .. 70:43 . 0 . .0 '0 0 0 ' 0 ; ;0 `: 0. 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 1 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W_ . 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 Vl/ 13A4ocs 0.143 sw 4.00 2.55 0 0 0 0 64 57 228 145 � G 1Aclom 1.270 sw 35.56 42.91 0 0 0 0 7 5 247 298 13A�acs 0.143 nw 4:00 2.55 0 0 0 .0 0 0 0 0 1.270 nw 35:56 45;24 0 0 0 . . 0 0 0 : 0 0 4A5 tom .. 0:770 21.515 27.- 4 = 0. 0 . 0 0 0 0 p 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0_ 0 0 6 0 0 C 16A-30md -'0.032., - -0:90. 2.32 63 63 56, 146 56 56 50 F 2?FWpl 0.989 - 27.69 0.00 63 6 0 0 56 .. 8 222 .130 0 6 c)AED excursion -2 .225 Envelope loss/gain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 56 145 887 836 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 145 887 836 15 Duct loads 31% 48% 18 69 31% 48% 276 399 17 Total room load 74 214 1162 1935 Air required (cfm) 41 91 57 54 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wright50Tt' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 2 ..Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup .Calc = MJ8 Front Door faces: N -- wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALLS, INC. 317 ST..LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email; QUICKCALCS@AOL.COM 1 Room name KrrCHEN BATH 2 F�osed wall 0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 192.0 ft 9.0 x 5.0 ft 5 R6om area 192.0 ft2 45.0 ft2 TY Construction U-value Or HTM Area (ft-) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Grass WP/S Heat Cool 6 V 13A-0oos - - 0143 ne': 4.00 2 95 :' 6 . 0 . 0 0 ' : .40 40 160 102 ^ 1A-c1om 1.270 - nv, . 35:56 70.43 ;- 0 :. 0 0 0 - 0 '. 0, `0 '0 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 IA-c1om 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W MA4ocs 0:143. s 4.00 255 0 0. 0 0 0 0 0 0 t13A-4ocs 0.143 sw' 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 -C� 13AAocs 0.143 nw 4.00 2.55 0 0 0 '0 0 0 .0 0 1Aclomi - 1.270 nw:. 35.56 45:24 0 io p p p 0' 0 -0. 4A5-2om ; ::_0.770 , nw 21:56 27.54 0 -0 0 `.. 0 . 0 .0 0 " 0 P 12C-Osw 0.091 - 2.55 1.28 64 64 163 82 0 0 0 0 C 16A-3Omd 0i032 ' - ;6.90 : '2.32 :: 192 192, 172 445 :. 45 .45 46, 104 F 22A-tpl 0.989 2.7.69. 0.00 192 6. 0 0 45 _ 5 138 0 6 c)AED excursion -27 -2 Envelope loss/gain 335 501 339 204 12 a) Infiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 p Subtotal (lines 6 to 13) 335 2501 426 228 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 .0 14 Subtotal 335 2501 426 228 151 Duct loads 1 31% 48% 104 1194 31% 48% 133 109 Total room load 439 3695 7 559 336 Air required (cfm) 21 162 27 15 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. A%= +4_ wrigFitsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 ' 2017-Apr-10 1AEUN Page 3 ..Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 . Front Door faces: N + wrightsoftRight-JO Worksheet Job: Entire House Date: By: QUICK CALLS, INC.' 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-46M796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 ENTRY 2 3 Exposed wall Room height 32.2 ft 8.0 ft heat/cool 7.0 ft 8.0 ft heaUcool 4 5 Room dimensions Room area 1.0 x 203.5 ft 203.5 ft2 1.0 x 55.0 ft 65.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter . (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 . 11��G 13A4ocs ;1A-c1om • 13A-flocs "' 0.143 1:270 0.143 ne' ne se 4 W .. 35 56: 4.00 `' 2'65 " 70.43 2.55 : ' _ 128 0 80 128 0 56 . 513 0 225 .. 326 .. -0. 143 0 ' 0 48 '0 0 26 : 0 , ' 0 106 : ' 0 : 0 67 11 1Ac1om 11DO 1.270 0.390 se se 35.56 10.92 34.77 11.31 24 0 24 0 848 0 829 0 0 22 0 22 0 236 0 244 W . VI/ 13A4ocs' 13A4ocs 1Aclom 13A-4ocs 1A-61om 4A5-2om . 12C-0sw 16A-30md- 0143 0.143 1.270 0:143 1.270 0:770 0.091 D U32 s sw sw nw : nw. nw _ 4:00 4.00 35.56 4.00. 35i56 21-56 2.55 ; 0.9Q 2.55 2.55 42.91 Z55 45.24 27-.54 _ 1.28 . 2.32 34 16 0 0 0 ' 0 0 204 34 16 0 0 0 . 0 0 204 136 64 0 0 0 0 0 . 162 86 41 0 0 0 .0 0 472 0 8 0 0 0 0 72 : - 55 0 8 0 0 0 ' 0 72 5$ 0 32 0 0 0 . 0 183 '. 49 0 20 0 0 0 0 92 128 -G P tC F 22A tpl 0.989 27.69 0.00 204 32 891 .. 0 55 7 194 0 6 c)AED excursion -24 -6 Envelope loss/gain 2859 1873 800 545 12 a) Infiltration 564 164 122 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 MO 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3422 2257 922 579 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3422 2257 922 579 151 Duct loads 31% 48% 1064 1078 31% 48% 287 276 Total room load 4486 3335 1209 855 Air required (cfm) 218 146 59 38 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .4CA A4- wrightsoft- 2017-Apr-10 1 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 ...Wrightsoft HVAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N ' - - wriglksoft° Right-J® Worksheet Job: Entire House date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 . Email: QUICKCALCS@J\OL.COM 1 Room name LAUNDRY GREAT/DINING 2 Fposed wall 6.0 ft 46.0 ft 3 Room height 8.0 ft heat/cool 8.9 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 488.0 ft 488.0 ft2 Ty . Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/f?;- F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�! IMA . - -s - ; 0.143 ne 4 00 "• 2 55 ' 0 0, 0 '0 231 194 ':' 775 -. • 493 I-C, i1'Ac1om = 1,:27D ne ' "35.56y 70.43 0 0 0 0 38 •' 0 i 134.4 2662 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1 -G 1A-c1om 11DO 1.270 0.390 se se 35.56 10..92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W t-G :1MA= 13AAocs 0.143 0.143 s sw 4.00 4.00 2:55 2.55 0 48 0 48 0. 192 .0 122 0 0 0 0 0 0 0 0 1A-c1om 13AA6cs _IA-clom 1.270 0.143 1.270 sw nw nw 35.56 4.00 35.56 42.91 2.55 45.24 0 0 0 0 0. 0 0 0 0 0 .0 0 0 178. 0 0 137. 0 0 `549 0 0 .349 0 4 4A5-20m:. 12C-0sw 16q=30md 0.770 0.091 0:032 ; nw . - '-, _ 21.56.: 2.55. &90' 27.54 1.28 - P:32 0.. 56 42 0 56 42 0 143 : 38 .0 72 . 97 - 41 0 ... 488 0 0 _ - . 488 880 0 > • 437: , - -1124 0 ; .1132 P ,C F 22A tpl 0.989 - 27.69 0.00 42 6 166 0 488 46 1274 0 6 c)AED excursion -3 -56 Envelope loss/gain 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 .460 Appliances/other 0 0 Subtotal (lines 6 to 13) 644 317 6154 6409 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 317 6154 6409 15 Duct loads 31% 480 200 151 31% 48% 1913 3060 Total room load a" 468 8067 9469 Air required (cfm) 41 21 393 416 Calculations approved bvACCA to meet all requirements of Manual .J 8th Ed. c -Fk wrightsoft- 2017-Apr-1017:14:53 I&A Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 ...Wdghtsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N - - weightsoft° Duct System Summary Jo Entire House By: QUICK CALCS,INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46M796 _ Email:, QUICKCALCS , OL.COM Project Intormation For. WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 .in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATE+ h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDROOM 2 h 4486 218 146 0.374 6.0 Ox 0 VIFx 18.6 115.0 SO BEDROOM -A h 3501 170 149 0.297 6.0 OxO VIFx 33.1 135.0 st2 BEDROOM-B h 3501 170 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 ENTRY h 1209 59 38 0.510 4.0 Ox 0 VIFx 3.0 95.0 GREAT/DINING c 4735 196 208 0.318 7.0 Ox0 VIFx 22.4 135.0 st2 GREAT/DINING-B c 4735 196 208 0.307 7.0 Ox0 VIFx 28:1 135.0 st2 KITCHEN C 3695 21 162 0.375 7.0 Ox 0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 Ox 0 VIFx 21.6 115.0 st1 M. BATH h 1162 57 54 0.366 4.0 Ox 0 VIFx 21.6 115.0 st1 wic C 214 4 9 0.310 4.0 Ox0 VIFx 26.3 1 135.0 1 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 737 724 0.284• 689 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx wri htsoft@ 2017-Apr-10 17:14:54 " 1� 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ... Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Doorfaces: IN Return Branch Detail Table Name Grille Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FIR Veloc (fpm). Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mati Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft` 2017-Apr-1017:14:54 ACA9 RightSuite® Universal 2017 17.0.14 RSU08101 page 2 ...Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N