Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MOBERG RES Builder Name: Street: 245 BIMINI DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1715.7 sqft.) Insulation Area a. Concrete Block - Int Insul, Exterior R=9.0 1435.70 ft2 2. Single family or multiple family Single-family b. Frame - Wood, Adjacent R=11.0 280.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A 10. Ceiling Types (1407.0 sqft.) R= ft2 Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1407.00 ft2 6. Conditioned floor area above grade (ft2) 1407 b. N/A R= ft2 ft2 c. N/A R= Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(169.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 275 a. U-Factor: Dbl, U=0.65 169.80 ft2 SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency b. U-Factor: N/A ft2 a. Central Unit 24.0 SEER:16.00 SHGC: c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1407.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1407.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 49.78 PASS Glass/Floor Area: 0.121 Total Baseline Loads: 55.79 I hereby certify that the plans and specifications covered by Review of the plans and O�t$E Sr,4?� this calculation are in c pliance with the Florida Energy specifications covered by this Code. calculation indicates compliance �'� O with the Florida Energy Code. mu:. f•••. •;P=r .':•"° ,ti PREPAR BY DATE: -- Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in c mpliance Florida Statutes. Qth the Florida Energy Code. COD yvE•i�v OWNER/AGENT: BUILDING OFFICIAL: DATE: - 00 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 8/15/2017 8:42 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: MOBERG RES Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1407 Lot # Owner: Total Stories: 1 Block/SubDivision: of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 245 BIMINI DRIVE Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1407 14962.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 221 2077.4 No 2 1 1 No Yes Yes 2 M BATH 66 620 No 0 1 No Yes Yes 3 WIC 58 545 No 0 1 No Yes Yes 4 BEDROOM 2 175 1645 No 1 1 1 No Yes Yes 5 DINING 143 1716 No 0 1 No Yes Yes 6. KITCHEN 143 1716 Yes 0 1 No Yes Yes 7 LIVING ROOM 382 4584 No 12 1 No Yes Yes 8 . BATH 2 45 423 No 0 1 No Yes Yes 9 BEDROOM 3 174 1635.6 No 1 1 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 30 ft 0 221 ft2 _--_ 0 1 0 2 Slab -On -Grade Edge Insulatio M BATH 6 ft 0 66 ft2 ---- 0 1 0 ' 3 Slab -On -Grade Edge Insulatio WIC 1 ft 0 58 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio BEDROOM 2 14 ft 0 175 ft2 _--- 0 1 0 5 Slab -On -Grade Edge Insulatio DINING 11 ft 0 143 ft2 ---_ 0 1 0 6 Slab -On -Grade Edge Insulatio KITCHEN 24 ft 0 143 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio LIVING ROOM 25 ft 0 382 ft2 __-_ 0 1 0 8/15/2017 8:42 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 Gnann adnr,_':n1e FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio BATH 2 1 ft 0 45 ft2 -___ 0 1 0 ' 9 Slab -On -Grade Edge Insulatio BEDROOM 3 26 ft 0 174 ft2 ____ 0 1 0 ROOF / Roof , Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1483 ft2 0 ft2 Light 0.6 No 0.9 No 20 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1407 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BEDRO 20 Blown 221 ft2 0.1 Wood 2 Under Attic (Unvented) M BATH 20 Blown 66 ft2 0.1 Wood 3 Under Attic (Unvented) WIC 20 Blown 58 ft2 0.1 Wood 4 Under Attic (Unvented) BEDROOM 2 20 Blown 175 ft2 0.1 Wood 5 Under Attic (Unvented) DINING 20 Blown 143 ft2 0.1 Wood 6 Under Attic (Unvented) KITCHEN 20 Blown 143 ft2 0.1 Wood 7 Under Attic (Unvented) LIVING ROOM 20 Blown 382 ft2 0.1 Wood 8 Under Attic (Unvented) BATH 2 20 Blown 45 ft2 0.1 Wood 9 Under Attic (Unvented) BEDROOM 3 20 Blown 174 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below ()cot TO MIMI TAgppSpace _ 1 E Exterior Concrete Block - Int InsWASTER BE 9 13 0 9 5 122.4 ft2 0 0 0.5 0 _ 2 S Exterior Concrete Block - Int InsMASTER BE 9 17 0 9 5 160.1 ft2 0 0 0.5 0 3 E Exterior Concrete Block - Int Insul M BATH 9 6 0 9 5 56.5 ft2 0 0 0.5 0 4 E Exterior Concrete Block - Int InsBEDROOM 2 9 14 0 9 5 131.8 ft2 0 0 0.5 0 5 S Exterior Concrete Block - Int Insul DINING 9 11 0 12 0 132.0 ft2 0 0 0.5 0 6 S Exterior Concrete Block - Int InsulKITCHEN 9 11 0 12 0 132.0 ft2 0 0 0.5 0 7 W Exterior Concrete Block - Int InsulKITCHEN 9 13 0 12 0 156.0 ft2 0 0 0.5 0 8 N Exterior Concrete Block - Int InsWVING ROO 9 6 0 12 0 72.0 ft2 0 0 0.5 0 9 W Exterior Concrete Block - Int InsiilVING ROO 9 19 0 12 0 228.0 ft2 0 0 0.5 0 10 N Exterior Concrete Block - Int InsBEDROOM 3 9 13 0 9 5 122.4 ft2 0 0 0.5 0 11 W Exterior Concrete Block - Int InsBEDROOM 3 9 13 0 9 5 122.4 ft2 0 0 0.5 0 12 N Garage Frame - Wood BEDROOM 3 11 30 9 4 280.0 ft2 0.23 0.5 0 8/15/2017 8:42 AM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 / FORM R405-2014 • DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 N Insulated LIVING ROO None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 E 1 Metal S 2 Metal E 3 Metal E 4 Metal S 5 Metal S 6 Metal W 9 Metal N 10 Metal Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 0.65 0.25 15.0 ft2 2 ft 0 in 1 ft 4 in 24.0 ft2 2 ft 0 in 1 ft 4 in 6.0 ft2 2 ft 0 in 1 ft 4 in 15.0 ft2 2 ft 0 in 1 ft 4 in 40.8 ft2 2 ft 0 in 1 ft 4 in 9.0 ft2 2 ft 0 in 1 ft 4 in 30.0 ft2 2 ft 0 in 1 ft 4 in 30.0 ft2 2 ft 0 in 1 ft 4 in None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft2 400 ft2 30 ft 9.4 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000473 1745.6 95.83 180.22 .3453 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 24 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None 8/15/2017 8:42 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply -- --- Return ---- Air CFM 25 CFM25 HVAC # v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 275 ft2 Attic 95 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heatng H Jan H Feb H Mar Apr I May un f Xi Jul ri J I 4xi Aug JXJSep W Nov Venting Jan Feb X Mar Apr May Jun [ Jul [ Aug Sep Oct X� Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (VVEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 8/15/2017 8:42 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MOBERG RES Builder Name: Street: 245 BIMINI DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 8/15/2017 8:42 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1