HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MOBERG RES Builder Name:
Street: 245 BIMINI DRIVE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1715.7 sqft.)
Insulation Area
a. Concrete Block - Int Insul, Exterior
R=9.0 1435.70 ft2
2. Single family or multiple family Single-family
b. Frame - Wood, Adjacent
R=11.0 280.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
10. Ceiling Types (1407.0 sqft.)
R= ft2
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 1407.00 ft2
6. Conditioned floor area above grade (ft2) 1407
b. N/A
R= ft2
ft2
c. N/A
R=
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(169.8 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 275
a. U-Factor: Dbl, U=0.65 169.80 ft2
SHGC: SHGC=0.25
12. Cooling systems
kBtu/hr Efficiency
b. U-Factor: N/A ft2
a. Central Unit
24.0 SEER:16.00
SHGC:
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1407.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1407.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified
Loads: 49.78
PASS
Glass/Floor Area: 0.121
Total Baseline
Loads: 55.79
I hereby certify that the plans and specifications covered by
Review of the plans and
O�t$E Sr,4?�
this calculation are in c pliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
�'�
O
with the Florida Energy Code.
mu:. f•••. •;P=r .':•"° ,ti
PREPAR BY
DATE: --
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in c mpliance
Florida Statutes.
Qth the Florida Energy Code.
COD yvE•i�v
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: - 00
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
8/15/2017 8:42 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: MOBERG RES
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1407
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
245 BIMINI DRIVE
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1407 14962.6
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 MASTER BEDROO
221 2077.4 No
2
1
1 No
Yes
Yes
2 M BATH
66 620 No
0
1 No
Yes
Yes
3 WIC
58 545 No
0
1 No
Yes
Yes
4 BEDROOM 2
175 1645 No
1
1
1 No
Yes
Yes
5 DINING
143 1716 No
0
1 No
Yes
Yes
6. KITCHEN
143 1716 Yes
0
1 No
Yes
Yes
7 LIVING ROOM
382 4584 No
12
1 No
Yes
Yes
8 . BATH 2
45 423 No
0
1 No
Yes
Yes
9 BEDROOM 3
174 1635.6 No
1
1
1 No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 30 ft 0
221 ft2
_--_
0 1
0
2 Slab -On -Grade Edge Insulatio
M BATH 6 ft 0
66 ft2
----
0 1
0
' 3 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
58 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio
BEDROOM 2 14 ft 0
175 ft2
_---
0 1
0
5 Slab -On -Grade Edge Insulatio
DINING 11 ft 0
143 ft2
---_
0 1
0
6 Slab -On -Grade Edge Insulatio
KITCHEN 24 ft 0
143 ft2
----
0 1
0
7 Slab -On -Grade Edge Insulatio
LIVING ROOM 25 ft 0
382 ft2
__-_
0 1
0
8/15/2017 8:42 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software
Page 2 of 5
Gnann adnr,_':n1e
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio BATH 2 1 ft
0
45 ft2
-___
0
1
0
'
9 Slab -On -Grade Edge Insulatio BEDROOM 3 26 ft
0
174 ft2
____
0
1
0
ROOF
/
Roof ,
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Hip Metal 1483 ft2
0 ft2
Light
0.6
No
0.9
No
20
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Unvented
0
1407 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented) MASTER BEDRO
20
Blown
221 ft2
0.1
Wood
2
Under Attic (Unvented) M BATH
20
Blown
66 ft2
0.1
Wood
3
Under Attic (Unvented) WIC
20
Blown
58 ft2
0.1
Wood
4
Under Attic (Unvented) BEDROOM 2
20
Blown
175 ft2
0.1
Wood
5
Under Attic (Unvented) DINING
20
Blown
143 ft2
0.1
Wood
6
Under Attic (Unvented) KITCHEN
20
Blown
143 ft2
0.1
Wood
7
Under Attic (Unvented) LIVING ROOM
20
Blown
382 ft2
0.1
Wood
8
Under Attic (Unvented) BATH 2
20
Blown
45 ft2
0.1
Wood
9
Under Attic (Unvented) BEDROOM 3
20
Blown
174 ft2
0.1
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing
Solar
Below
()cot
TO MIMI TAgppSpace
_ 1
E
Exterior Concrete Block - Int InsWASTER BE
9 13
0 9
5
122.4 ft2
0
0
0.5
0
_ 2
S
Exterior Concrete Block - Int InsMASTER BE
9 17
0 9
5
160.1 ft2
0
0
0.5
0
3
E
Exterior Concrete Block - Int Insul M BATH
9 6
0 9
5
56.5 ft2
0
0
0.5
0
4
E
Exterior Concrete Block - Int InsBEDROOM 2
9 14
0 9
5
131.8 ft2
0
0
0.5
0
5
S
Exterior Concrete Block - Int Insul DINING
9 11
0 12
0
132.0 ft2
0
0
0.5
0
6
S
Exterior Concrete Block - Int InsulKITCHEN
9 11
0 12
0
132.0 ft2
0
0
0.5
0
7
W
Exterior Concrete Block - Int InsulKITCHEN
9 13
0 12
0
156.0 ft2
0
0
0.5
0
8
N
Exterior Concrete Block - Int InsWVING ROO
9 6
0 12
0
72.0 ft2
0
0
0.5
0
9
W
Exterior Concrete Block - Int InsiilVING ROO
9 19
0 12
0
228.0 ft2
0
0
0.5
0
10
N
Exterior Concrete Block - Int InsBEDROOM 3
9 13
0 9
5
122.4 ft2
0
0
0.5
0
11
W
Exterior Concrete Block - Int InsBEDROOM 3
9 13
0 9
5
122.4 ft2
0
0
0.5
0
12
N
Garage Frame - Wood BEDROOM 3
11 30
9
4
280.0 ft2
0.23
0.5
0
8/15/2017 8:42 AM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 /
FORM R405-2014
•
DOORS
#
Ornt
Door Type Space
Storms
U-Value Width
Ft In
Height
Ft In
Area
1
N
Insulated LIVING ROO None
.39 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
#
Wall
Ornt ID Frame
Panes NFRC
U-Factor SHGC
Overhang
Area Depth Separation Int Shade
Screening
1
2
3
4
5
6
7
8
E 1 Metal
S 2 Metal
E 3 Metal
E 4 Metal
S 5 Metal
S 6 Metal
W 9 Metal
N 10 Metal
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
0.65 0.25
15.0 ft2 2 ft 0 in 1 ft 4 in
24.0 ft2 2 ft 0 in 1 ft 4 in
6.0 ft2 2 ft 0 in 1 ft 4 in
15.0 ft2 2 ft 0 in 1 ft 4 in
40.8 ft2 2 ft 0 in 1 ft 4 in
9.0 ft2 2 ft 0 in 1 ft 4 in
30.0 ft2 2 ft 0 in 1 ft 4 in
30.0 ft2 2 ft 0 in 1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
400 ft2
400 ft2
30 ft
9.4 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000473
1745.6 95.83 180.22 .3453
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat None
COP:1
17 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit
Split
SEER: 16
24 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType Location
EF Cap
Use SetPnt
Conservation
1
Electric
None Garage
0.95 50 gal 60.9 gal 120 deg
None
8/15/2017 8:42 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft2
DUCTS
-- Supply --
--- Return ----
Air
CFM 25
CFM25
HVAC #
v #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 275 ft2
Attic
95 ft2 Default Leakage
Garage
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Heatng H Jan
H Feb
H Mar
Apr
I
May un f Xi Jul
ri J
I
4xi Aug
JXJSep
W
Nov
Venting Jan
Feb
X Mar
Apr
May Jun [ Jul
[ Aug
Sep
Oct
X�
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (VVEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
8/15/2017 8:42 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MOBERG RES Builder Name:
Street: 245 BIMINI DRIVE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
8/15/2017 8:42 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1