FORMf/R405-2014
File . C®pv
:FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method -
Project Name: WYNNE THE WINDSOR
Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERC�F , L , ` Permit Number:
Owner: ��r�i1�-C�j` R�eQ Jurisdiction:
Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1432.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1224.00 ft2
b. Frame = Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1753.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2) 1753
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sgl, U=0.54 111.36 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00,
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1753.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 53.74
Glass/Floor Area: 0.086
PASS
Total Baseline Loads: 53.87
I hereby certify that the plans and specifications covered by
Review of the plans and
�'tf1E SPq?,
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
4'OD yak
OWNER/ T
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
4/3/2017 1:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
'*
PROJECT
•Title: WYNNE THE WINDSOR
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT
Rotate Angle: 225
Street:
THE WINDSOR
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location TMY Site
Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1753
14024
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 MASTER BEDROO 224
1792 No
0
1
1
Yes
Yes
Yes
2 WIC 63
504 No
0
1
No
Yes
Yes
3 MASTER BATH 56
448 No
0
1
Yes
Yes
Yes
4 M.BATH 61
488 No
0
1
Yes
Yes
Yes
5 LAUDRY 36
288 No
0
1
No
Yes
Yes
6 BEDROOM 2 180
1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R 588
4704 No
2
1
Yes
Yes
Yes
8 KITCHEN 209
1672 Yes
0
1
Yes
Yes
Yes
9 BATH 50
400 No
0
1
Yes
Yes
Yes
10 HALL 25
200 No
0
1
No
Yes
Yes
11 FOYER 92
736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3 169
1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER
BEDRO 37 ft 0
224 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0
56 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0
61 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0
36 ft2
----
0 1
0
4/3/2017 1:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
^'
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft2
0
1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 ft
0
588 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN 11 ft
0
209 ft2
---
0
1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
HALL 1 ft
0
25 ft2
----
0
1
0
11SIab-On-Grade Edge Insulatio
FOYER 9 ft
0
92 ft2
----
0
1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft2
----
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials
Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed
Metal 1847 ft2
292 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V # Type
Ventilation
Vent Ratio (1 inj
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type.
Area
Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1 .
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0:1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0:1
Wood
WALLS
Adjacent
In JAJn11 Typepace
Cavity Width
SOrnt life Et In
Height
Et In
Area
Sheathing Framing
R-Nlahle.�action
Solar
Absor
Below
Grade%
_ 1 NE=>W Exterior Concrete Block - Ext InsMASTER BE
4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
2 SW=>E Exterior Concrete Block - Ext IndMWSTER BE
4.1 7
0 8
0
56.0 ft2
0
-0
0.5
0
_ 3 NW=>S Exterior Concrete Block - Ext Ind ASTER BE
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
4 NE=>W Exterior Concrete Block - Ext InddASTER BA
4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
4/3/2017 1:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WALLS
F
Adjacent Space
nrnt 10 Wall up,5
Cavity Width
Height
Sheathing Framing Solar Below
NE=>W Exterior
Concrete Block - Ext InsuM. BATH
4.1 7
0
8
0
56.0 ft2
0
0
0.5
0
6
NE=>W Exterior
Concrete Block - Ext InJ3EDROOM 2
4.1 12
0
8
0
96.0 ft2
0
0
0.5
0
7
SW=>E Exterior
Concrete Block - Ext InadNING/GRE
4.1 30
0
8
0
240.0 ft2
0
0
0.5
0
8
NW=>S Exterior
Concrete Block - Ext InQJNING/GRE
4.1 20
0
8
0
160.0 ft2
0
0
0.5
0
9
SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8
0
88.0 ft2
0
0
0.5
0
10
NE=>W Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8
0
40.0 ft2
0
0
0.5
0
11
SE=>N Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8
0
64.0 ft2
0
0
0.5
0
12
SW=>E Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8
0
8.0 ft2
0
0
0.5
0
13
NE=>W Exterior
Concrete Block - Ext InQEDROOM 3
4.1 13
0
8
0
104.0 ft2
0
0
0.5
0
14
SW=>E Exterior
Concrete Block - Ext InfiEDROOM 3
4.1 1
0
8
0
8.0 ft2
0
0
0.5
0
15
N=>SW Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.5
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>N Insulated FOYER
None
.39
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V
# Ornt ID
Frame Panes NFRC U-Factor
SHGC
Area
Depth
Separation
Int Shade
Screening
1 NW=>S 3
Metal Low-E Single Yes
0.54 0.25
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5
Metal Low-E Single Yes
0.54 0.25
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
3 NE=>W 6
Metal Low-E Single Yes
0.54 0.25
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
4 SW=>E 7
Metal Low-E Single Yes
0.54 0.25
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5 NW=>S 8
Metal Low-E Single Yes
0.55 0.25
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6 NE=>W 13
Metal Low-E Single Yes
0.54 0.25
16.2 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
GARAGE
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82
168.92
.2598
7
4/3/2017 1:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit
Split
SEER: 15 34.8 kBtu/hr drn
0.85
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftZ
DUCTS
— Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 325 ftZ
Attic
95 ftZ Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
Venting HJan
Jan Feb
Feb
Mar
Mar
Apr
Apr I
Ma X Jun �Xj Jul
I May i Jun Jul
rl Aug
Aug
Se
rl Sep
Oct
Oct
Nov
HX Nov
Dec
H Dec
txl
L
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
4/3/2017 1:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
1
FORM,R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: , WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
4/3/2017 1:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1