Loading...
HomeMy WebLinkAboutProject Informationr *wrightsofto Project Summary Enure House, QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 77246M799 Fax 772-466-�796 Email: QUICKCALCS@AOL.COM For: WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL Notes: Job: Date: By: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18188 Btuh Structure 17877 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh . Central vent (0 cfm) 0 Btuh e) Humnone idification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling Area (none) (ft2) 1474 1474 Equipment latent load 5277 Btuh Volume (ft3) .12227 12227 Air changes/hour 0.45 0.23 Equipment total load 30370 Btuh Equiv. AVF (cfm) 92 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 470F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual air flow 1160 cfm Actual air flow 1160 cfm Airflow factor 0.040 cfm/Btuh Airflow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 33 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft` 2017-Apr-1017:14:53 Right -Suite® Universal 2017 17.0.14 RSU08101 page 1 ��` ...Wrightsoft HVAC%WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N - wrilghtsoftRight-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a,OL.COM 1 Room name Entire House BEDROOM 2 Exposed wall 156.2 'ft 52.0 ft 3 Room height 8.3 ft d 8.0 ft heal/cool 4 5 Room dimensions Room area 1473.5 ft' 1.0 x 329.0 ft 329.0 ft2 Ty Construction Ll-value Or HTM Area z (ft-) Load number (Btuh/ft2 °F) (Btuh/ftx) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 s \�/ r� 13A44ocs 1Aclom- . 13A-4ocs 0:;143 .1.270 0.143 ne:: . ne" se 4:00 35 56' 4.00. 2.55 70.43 2.55 > 479 .. < 88 128 -. 442 , • " 0 83 .1766 1344 331 1124 �"2662 210 '86 : 0> 0 . ; 80 0 0 320 p 0 204 0 0 W 11 L_- {p 1A-c1om 11DO 1.270 0.390 se se 35.56 10.92 34.77 11.31 24 22 48 22 848 236 829 244 0 0 0 0 0 0 0 0 W V+l 13A4ocs 13AAms 1Aclom 13A4ocs. IA-c1orn 0.143 0.143 1.270 0.143 1.270 s sw sw, nw. nw' .4.00 4.00 35.56 400 35.56 2.55 2.55 42.91 2.55 . 45.24 34 360 7 290 :. 33 34 353 11 217 0 136 1414 247 867 1162 86 899 298 '651 ". 1478 0 224 0 112 = 33 0." 224 0 79 ' :0 0 897 0 318 1162 0 570 0 202 " 1478. -a P C; 4A5 tom . " 12C-0sw .16A30md .6.770 0.091 .,0.032 nvu - •. - 21.56 2.55 ::0.90 ;. 27:54 1.28 > 2.32 41 192 1474 . 0 1.92 1474. 880 489 : 1320 1124. 246 3419 0 0 329 0 0 329 : 0 0 295 ' . 0 0 " 763 F 22A-tpl 0.989 27.66 0.00 1474 156 4325 0 329 52 1440 0 6 c)AED excursion 784 680 Envelope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 2 460 Appliances/other 2000 0 Subtotal pines 6 to 13) 18188 17877 5341 4606 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18188 17877 5341 4606 15 Duct loads 31% 48% 5654 8536 31% 48%1 1660 2199 Total room load 23842 26413 7001 6805 Air required (cfm) 1160 1160 341 299 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ti 411- wrightsoft' 2017-Apr-1017:14:53 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Cale = W8 Front Door faces: N - wJob: rightsoft° Right40 Worksheet Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name WIC M. BATH 2 Exposed wall 0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 ft 5 Room area 63.0 ft2 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) . Load Area (ft2) Load number (Btuh1ft2-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/PIS Heat Cool 6 yJ 13A4ocs.- . " 0.14'3 ne: 4 &i 2.55 ; .01 ". 0 ". " ' 0 0 0 ," 0 0 Lam' ;1A 1om 1,270 . 06 35.56 70 43 '. ` -'0 0 " : 0 0 " 0 ' " 0 "0 p 13A4ocs 0.143 se 4.00 Z55 0 0 0 0 0 0 0 0 1Aclom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13A40os 0.143 • s 4.00 2.65 0 0 0 0 0 0 0 0 VtJ 13A-4ocs 0.143 sw 4.00 255 0 0 0 0 64 57 228 145 -a IA-clom 1.270 sw 35.56 42.91 0 0 0 0 7 5 247 298 13A-4ocs 0.143 nw 4.00 2:55 0 0 0 0 0 0 0. 0 1A�c-1orn .1:270 -,mv 35.56, 45.24 0 ' : "0 0 0 - 0 ` 0 . " • 0 " 0 '4A5-tom- . -.0:770 :nw' - 21..56; 27.54 0. 0 " 0 0 0 " 0 . 0 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 C - ',16A30md 0 0$2 - "- 0.90, : Z.32 63 63 56 146 " . 56 66 50 : 130 F 22A-tpl 0.989 - 27.66 0.00 63 0 0 0 56 8 222 0 6 c)AED excursion -2 225 Envelope loss/gain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 56 145 887 836 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 145 887 836 15 Duct loads 31% 48% 18 69 31% 48% 276 399 Total room load 74 214 1162 1235 Air required (cfm) 4 91. 57 54 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -�- wcightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17P.age 2 A&� ...Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N - - wrightsofts Right-M Worksheet Job: Entire House -Date: QUICK CALCS, INC. By 317 ST,LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email; QUICKCALCS@AOL.COM 1 Room name KITCHEN BATH �sed l Oft 5.0 ft 3 m height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 192.0 ft 9.0 x 5.0 ft 5 Room area 192.0 ft2 45.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft= °F) (Btuh/ft2) or perimeter (ft) (Btuh or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/PIS Heat Cool 6 13A-0oCs':. 0143 rie 4.00.. . 2:55 .' 0 . 0 0 . :. 0 40 40 160, : 102 r. , G 1A-c1om • .. 1.270 no:: 35 56 . 70.43 p 0 .. .. p • .. p ..., • . p .. p 0 p 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 IA-clom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 W 13A4ocs 0-143. s 4.00 Z55 0 0. 0 0 0 0 .0 0 0 V►! 13A-4ocs 0.143 sw' 4.00 2.55 0 0 0 0 0 0 0 0 T_C IA-c1om 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 13A flocs ' 0 143 nw 4 00 255 0 0 0 0 0 0 A 0 1A clom; : 1 270 :nw- 35'56; '45.24 0 0 .0 0 0 p. p 0 4A5 tom 0.770 nW 21.56 , 27:54 0 0 ". 0 - 0 0 P _ 12C-0sw 0.091 - 2.55 1.28 64 64 163 82 0 0 0 0 C'. :16A Omd 0.032. ? - .:U.90 . 2.32 ! 192 192 172 ; 445 45 :.. 45 40 ; 104 F 22A tpl 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 a)AED excursion -27 -2 Envelope loss/gain 335 501 339 204 12 a) Infiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 p Subtotal (lines 6 to 13) 335 25011 426 228 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 335 2501 426 228 15 Duct loads 31% 48% 104 1194 31% 48% 133 109 Total room load 439 3695 559 336 Air required (cfm) 1 1 211 1621 271 15 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. * wrightsci t' 2017-Apr-.1017:14:53 .�A Right -Suite® Universal 2017 17.0.14 RSLI08107 Page 3 ..Wdghtsolt WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N - - WrightsoftRight-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: M-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name BEDROOM 2 ENTRY 2 3 4 5 Exposed wall Room height Room dimensions Room area 32.2 ft 8.0 ft heaticool 1.0 x 203.5 ft 203.5 ft2 7.0 ft 8.0 ft heat/cool 1.0 x 55.0 ft 55.0 ftx Ty Ccnstruction number U-value (Btuh/ft2 °F) Or HTM (Btuhlftz) Area or perimeter (ft) (Btuh) ors perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 11 '.yyJJ �--G 6 W V�! Y-G 13A4ocs 1Ac1om 13AAocs 1A-c1om 11D0 13A-0ocs 13A-4ocs IA-c1om 13A�dcs 1A�1om. :4A5 tom . 12C-0sw "16A:30md- 22A-tpl 0.143 1.270 0.143 1.270 0.390 0.143 0.143 1.270 0.143 1.270 0.7Z0 0.091 .0032 0.989 ne:= "Ni se se se - s sw sw nw : nw nw - - - : 4 00: 35.56' 4.00 35.56 10.92 4:00 4.00 35.56 4'00 3556 . 21:56 2.55 0;90' 27.69 2:55 70:43 2.55 34.77 11.31 2:55 2.55 42.91 2.55 : 45.24 27.54 1.28 -232 0.00 :• 128 ` U 80 24 0 34 16 0 0 0 0. 0 - . 204 204 128 ` 0 56 24 0 34 16 0 0 0 0 0 204 32 513 0 226 848 0 136 64 0 0 0 0 0 182 891 : 326 ". ,0 143 829 0 86 41 0 .0 0 .0 0 . 472 0 ' . 0 : 0 48 0 22 0 8 0 o 0 0 0 72 : 55 55 = 0 :0 26 0 22 0 8 0 0 0. - 0'. 72 55 7 ' ... • 0 .0 106 0 236 0 32 0 0 0 0 183. 49. , 194 . ' -0 0 67 0 244 '0 20 0 -0 • 0 0 92 128 0 P :C F 6 c)AED excursion -24 -6 Envelope loss/gain 2859 1873 800 545 12 a) Infiltration 564 154 122 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 01 0 Subtotal (lines 6 to 13) 3422 2257 922 579 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 3422 0 0 2257 0 0 922 0 0 579 15 Duct loads 31% 489/6 1064 1078 31% 48% 287 276 Total room load Air required (cfm) 4486 218 3335 146 1209 59 855 3B Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �A wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Pg ae 4 ...Wrightsoft WVACIWYNNE-THE GRAND CARLTON-299.rup Cale = MJ8 Front Doorfaces: N 9 -- wrightsoft' Right-JO Worksheet Entire House • QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a( )AOL.COM Job: Date: By: 1 Room name LAUNDRY GREAT/DINING 2 E(posed wall 6.0 ft 46.0 ft 3 Room height 8.0 ft heat/cool 8.9 ft heat/cool 4. 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ftz 1.0 x 488.0 ft 488.0 ft' Ty Construction U-value Or HTM Area (ft-) s (ft') Load number (Btuh/ft2-°F) (Btuh1ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WKS Heat Cool 6 ,. 13A4ocs -` 0A43 ne ; . 4 00 2 55 0 0 0 .0 231 194 : 776 493 VLZ13A-4ocs `. 1Ac1om := : " 1270 0.143 ne se ": 35:56 4.00 = . 7043 2.55 • 0 0 0 0 0 0 0 0 38 0 0 0 _ 1344 0 '2662 0 11 IA-clom 11D0 1.270 0.390 se se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W Vi1 Y-G 13AAocs 13AAocs 1A-clom 0.143 0.143 1.270 s sw sw 4.00 4.00 35.56 255 2.55 42.91 0 48 0 0 48 0 0. 192 0 0 122 0 0 0 0 0 0 0 .0 0 0 0 0 0 13AAocs 1A=clom 0.143 1.270 nw ; nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 ' 178 0 . 137 0 . `549 - 0 _ 349 0 P C 4A5.2om. 12C-0sw 16A 30md :. 0.770 0.091 0032 " nw - ;. -; 21:56 2.55 0;90 . 27.54 1.28 232 0.. 56 42 0 56 - 42 0 143 , - 38 .0 72 97 41 0 488 0. 0 .' - 488 . 880. 0 : 437, 1124 0 :: 1132 F 22A tpI 0.989 - 27.69 0.00 42 6 166 0 488 . 46 1274 0 6 c)AED excursion -3 -56 Envelope loss/gain 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal pins 6 to 13) 644 317 6154 6409 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 317 6154 6409 15 Duct loads 31% 48%1 200 . 151 31% 48% 1913 3060 Total room load 1 844 468 8067 9469 Air required (cfm) 41121 3931 416 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk- wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page age 5 ...Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N Duct System Summary Job: -- wrightsoft' . y Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799 Fax 772-466-6796 . Email:. QUICKCALCS AOL.COM f-'roject Intormation For: WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL External static pressure Pressure losses Available.static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR(in) Diam H x W (In) Duct Matl Actual Ln (ft) . Rg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDROOM 2 h 4486 218 146 0.374 6.0 Ox0 VIFx 18.6 115.0 st1 BEDROOM -A h 3501 170 149 0.297 6.0 OxO VIFx 33.1 135.0 st2 BEDROOM-B h 3501 170 149 0.284 6.0 Ox0 VIFx 41.1 135.0 st2 ENTRY h 1209 59 38 0.510 4.0 Ox0 VIFx 3.0 95.0 GREAT/DINING c 4735 196 208 0.318 7.0 OxO VIFx 22.4 135.0 st2 GREAT/DINING-B c 4735 196 208 0.307 7.0 OxO VIFx 28.1 135.0 st2 KITCHEN c 3695 21 162 0.375 7.0 Ox0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 Ox 0 VIFx 21.6 115.0 st1 M. BATH h 1162 57 54 0.366 4.0 OxO VIFx 21.6 115.0 st1 WIC c 214 4 9 0.310 4.0 Ox 0 VIFx 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 737 724 0.284• 689 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx wri htsoft@ 2017-Apr-10 17:14:54 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 �� ...Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N :y Return Branch Detail Table Name Grille Size (in) Htg (cfm) clg (cfm) TEL (ft) Design FIR Veloc . (fpm). Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 ox0 1160 1160 0 0 0 0 ox 0 VIFx wri htsofta 2017-Apr-1017:14:54 9 Right -Suite® Universal 2017 17.M4 RSU08101 Page 2 ...Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N