HomeMy WebLinkAboutFl2569-R20 shingle underlayment114I2021 Florida Building Code Online
QF
'Professional Re' lation
i1CtS Home [ Log In User Registratlon `, Hot Topics Submit Surcharge ', Stets & Facts Publications i Contact Us'.. BCIS Site Map ',, Links Search
�i*
# Product Approval
1�-' USER: public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
Ft #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL2569-R20
Revision
2020
Approved
Soprema, Inc. (Canada)
1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400
memathieu@soprema.ca
Marc -Etienne Mathieu
m e math ieu @soprern a , ca
Marc -Etienne Mathieu
1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext 3327
memathieu@soprema.ca
Jean -Francois Cote, Ph.D.
1640 rue Haggarty
Drummondville
(SSS) 811-3145
jfcote@soprema.ca
Roofing
Underlayments
�4
aX,
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert 1. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/10/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R20 COI 2020 01 COI NIEMINEN.pdf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D4798
2011
ASTM D6163
2015
FM 4474
2011
FRSA/TRI Sixth Edition
2018
UL1897
2012
https:/lfloridabuilding.org/pr/pr, app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBlO8ErxlUd3xYlmjfmBrpDan9H30QGunUKXA%3d%3d V2
1/4/2021
Florida Building Code Online
Equivalence of Product Standards
Certlffed By
Sections from the Code
Product Approval Method Method 1 Option D
Date
Submitted
09/19/2020
Date
Validated
09/22/2020
Date
Pending FBC Approval
09/29/2020
Date
Approved
12/15/2020
Date
Revised
12/16/2020
Summary of Products
FL # Model, Number or Name
_. .,...._....... _..................................... _._...._._._._
Description
2569.1 Soprema Roof Underlayments
Self adhering roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2569 R20 II 2020 09 17 FINAL ER FL2569-R2Q.pdf
Verified By: Robert Nieminen, P.E, PE-59166
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-150
Evaluation Reports
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The
FL2569 R20 AF 2020 09 17 FINAL ER F1_2569-R20 pdf
design pressure noted herein pertains to underlayment systems
Created by Independent Third Party: Yes
used beneath adhesive -set tile systems. Refer to ER Section
5.6.4 for details.
-- -� -- .._.,,,-,_ _ _.._-_ .......—...,..,. _..
__. .......................... .._........ ......-
hark rdrkx:.
Contact Us :: 2601 Blair Stone Road Tallahassee FL 323,39 Phone: 850-4B7-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessiblllty Statement :: Refund statement
Under Florida law, email addresses are public records. If you do not want your e-mail address rclea5ed in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditionaf mail. If you have any questions, please contact 650.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address Pf they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can he made available to the public. To determine if you are a licensee under Chapter 455, F,S., please click here .
Product Approval Accepts:
® `i
Credit Card
Safe
https:llfloridabuildii)g.org/prlpr_app dtl.aspx?param=wGEVXQwIbgsKQFEnckBI08ErxlUd3xYlmjtmBrpi7an9H30QGunUKXAo/03d%3d 2/2
NEmo I etc.
14 Certificate of Authorization #32455
353 Christian Street, Unit 1413
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE 'TEST CONSULT
EVALUATION O.
Soprema, Inc. Evaluation Report S18010.06.09-R18
1640 rue Haggerty FL2569-R20
Drummondville, Quebec.12C 5P$ Canada Date of Issuance: 06/15/2009
(819) 478-2400 Revision 18: 09/17/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.F. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7t' Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle,
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMDIetc, Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: 'Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official,
This Evaluation Report consists of pages 1 through S.
Prepared by:
Robertl.M. Nieminen, P.E,
The facsimile
sea[ appearing was authorized by Robert
Florida Registration No. 59156, Florida DCR ANEI9$3
"•.;Ss�;;�"_ `F �;?
Nieminen, P.E- on 09117/2020. This does notserve as
., ,� .,
an electronically signed document
CERTIFICATION OF INDEPENDENCE:
1. NEIVlO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any Company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC, LLC
N
ROOFING COMPONENT EVALUATION: NEMO I etc.
SCOPE,1.
Product Category: Roofing
Sub -Category: U nderlayment
Compliance Statement: Roof Underlayments, as produced by SOprema, have demonstrated compliance with the
fallowing sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2012
1507.1.1, 1507.2.4, 1507.2.9.2 Material standard ASTM D1970 2015
/ R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018
1507.11.2 / R905.11.2 Material standard ASTM D6163 2015
TAS 110 Accelerated Weathering ASTM D4799 2011
3. REFERENCES:
En_ tits Examination Reference Date
ERD (TS16049) Wind Resistance 2778.07.05 07/15/2005
ERD (TST6049) ASTM D1970/TAS 110 (QC) S31370.03.10-1-131 04/07/2010
ERD (TST6049) FRSA/TRl 04-12 (OH) S11150.05.09-R2 10/05/2010
ERD (TST6049) ASTM D1970 (OH) 537210.11.11 11/09/2011
ERD (T5T6049) ASTM D1970 (M5) S37210.12.11 12/01/2011
ERD (TST6049) ASTM D1970 (MS) 540540.02.13-1 02/19/2013
ERD (TST6049) FRSA/TRI 04-12 (MS) S43530.02.14-1-111 02/21/2014
FRD (TST6049) ASTM D1970 (BC) S44870,04.14-2 04/02/2014
ERD (TST6049) ASTM D1970 (QC) S44870.04.14-3 04/02/2014
ERD (TST5049) ASTM D1970 (OH) S44870,04.14-1 04/10/2014
ERD (TST6049) ASTM D1970 (MS) 544870.04.14-4 04/10/2014
ERD (TST6049) ASTM D1970 (OH) S40540.10.14 10/31/2014
ERD [TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD (TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-RI 06/07/2017
M-D (CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES (EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
MEMO (TST5049) ASTM D1970 / TAS 110 (QC) SOPC-SC8970.08.15-R1 04/25/2018
NEMO (TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO (TST6049) ASTM D4798/D1970 (OH & MS) 45-SOPC-18-002.05.19.A 05/31/2019
NEMO (TST6049) Tensile Adhesion / Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020
NEMO (T5T6049) Peel adhesion (existing underlayments) 4j-S0PC-19-S5UDL-04.A 03/12/2020
PRI (TST5878) ASTM D1970 (MS) SOP-064-02-01 12/03/2013
Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL, LLC (QUA9625) Quality Control MLA File No. R27605 05/08/2019
UL, LLC (QUA9625) Quality Control Service Confirmation 06/29/2020
NEMO ETC, LLC Evaluation Report 518010.06.09-R18
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R20
Snprema Roof Underlayments Revision 18:09117/2020
Page 2 of 8
NNEMOjetc.
Product
Material
Standard
Plants)
Description
4.1
Lastobond TU HT
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
FRSA/TRi 09-18
surfaced, SAS modified bitumen roof
underlayment
4.2
Lastobond Shield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SAS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
4.3
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
4.4
Lastobond Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
4.5
Lastobond Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
4.6
Lastobond Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
4.7
EnviroShield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
4.8
Lastobond 195
ASTM D1970
Gulfport, M5
self -adhering, glass -mat reinforced, sand -
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
4.9
Lastobond Eaves
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Protection Sheet
Wadsworth, OH
surfaced, 585 modified bitumen roof
underlayment
4.10
Lastobond Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, aand-
Gulfport, MS
surfaced, SR5 modified bitumen roof
Wadsworth, OH
underlayment
4.11
Lastobond Smooth Seal
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
4.12
PrimeSource Grip -Rite
ASTM D1970
Gulfport, M5
self -adhering, glass -mat reinforced, film -
Smooth Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
4.13
RESISTO LB1236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
4.14
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Eave & Valley Protector
Gulfport, MS
surfaced, 5135 modified bitumen roof
Wadsworth, OH
underlayment
4.15
SRS TopShield ICE &
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
WATER DEFENDER
Gulfport, MS
surfaced, 513S modified bitumen roof
Wadsworth, OH
underlayment
4.16
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS. modified bitumen roof
Wadsworth, OH
underlayment
NEMO ETC, LLC Evaluation Report 518010.06.09-R18
Certificote ofAurhorizarion #32455 7T" EDITION i20201 F8C NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 18: 09/17/2020
Page 3 of 8
NNEMO j etc.
Material
aterial
Standard Plant(s) Description
4.17 Colphene FR GR ASTiVI D6163 Gulfport, MS self -adhering, fiberglass reinforced, granule -
Wadsworth, CIH surfaced, 5BS modified bitumen roof
underlayment
WITATIONS.-
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5,2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e„ Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components, Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.S Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Clay and Concrete Tile slate or
Asphalt (25073J Metal Wood
Underlayment Shingles Slate -Type
Mechanical Adhesive- Panels Shingles Shingles (1507.2) 8 8 Shingles Shakes (13a7.9)
Attach Set (1507.4) (t5075) (1507.7) (1507.8}
Yes Yes Yes
Lastohpnd TU HT Yes Yes
See 5.6.1 Yes Yes Yes (joint strips, 1507.1.1.3 (joint strips, 2507.1.1.3
R9051.1.3)
Lastobond Shield / Pro HT-N
/ RESISTO SA SMOOTH PLY Yes No No No No Yes Yes yes
(joint strips, 1507.1.13 (joint strips, 1507.1.1.3
40
J R905.1.1.3) / R905.1.1a]
Lastobund Shield HT / Pro Yes Yes
HT-5 Yes No No Yes Yes Yes (jointstrips,1507.1.1.3 point stops'
1s07.1.1.3
/ R905.1.1.3) / A905.1.1.3j
Yes Yes
LnviroShield Yes No No Yes Yes Yes
[j9int strips, 1507.1.13 (joint strips, 15117.1.1.3
/ R905.1.1..3] / i390SA.1,3]
Lastobond Eaves Protection Yes Yes
Sheet / Lastobond 195 Yes No
No R905.1.1.3) No No Yes (joint strips, ZS07.1.1.3 (joint strips, 1507.1.3.3
/ J R9pS.1.1.3]
Lasto6ond ECO / RESISTQ
LB1236, Grip -Rite Lave &
Yes Yes
Valley Protector /TopShield Yes No No No No Yes (iointstrip, 1507.1.1.3 (joint strips,1507.2.3A
ICE & WATER DEFENDER/ /R9os.1.1.3) /R905.1.1.3)
RESISTO LB1244
Lastohond Smooth Seal HT / Yes Yes
Grip -Rite Smooth Seal HT Yes No No Ycs Yes Yes(Joint strips, 1507.1.1.3 p (joint strips, 1507.1.1.3
/ R905.1.1.3) J R90SAA.3)
Col hene FR GR Yes Yes
P Yes Yes No No No Yes (joint strips, 1507.L (joint strips, 1507.1.1.3
/ R905.1.1.3) J R905.1.1.3)
NEMO ETC, LLC Evaluation Report 518010.06.09-R18
Certificate of Authoraction#32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.2569-1120
Soprema Roof Underlayrnents Revision 18; 09/17/2020
Page 4 of 8
ON EM o 1 etc.
5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations.
TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS'
Underlayment Adhesive Florida Product Approval
Lastobond TU HT Dupont "Tile Bondi" Roof Tile Adhesive" FL22525
ICP Adhesives and Sealants "Polyset'9 AH-160" FLG332
5.7 Allowable Substrates:
TABLE Z: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlaymen# Application Substrates (designed to meet wind loads for project)
Type Primer Material(s)
Lastobond Shield, Lastobond Pro (Optional) ASTM
HT-N, RESISTO SA SMOOTH PLY Deck / D41, Elastocol Stick, plywood, 05B or Southern Yellow Pine
40, Lastobond Shield HT, sheathing Elastocol Stick Zero (SYP)
Lastobond Pro HT-S, ASTM D41 structural concrete
EnviroShield, Lastobond TU HT,
Lastobond Eaves Protection Insulation (Optional) Elastocol Dens Deck Prime or SECUROCK Gypsum -
Sheet, Lastobond 195, Lastobond self- Stici<Zero Fiber Roof Board
ECO, RESISTO LB1236, Grip -Rite adhering
Eave & VaFey Protector,
TopShield ICE & WATER Base Sheet (Optional) Elastocol A5TM D226, Type II felt or Modified Sopra-
DEFENDER, RESISTO LB1244, Stick Zero G
Lastobond Smooth Seal HT or
Grip -Rite Smooth Seal HT
Deck/ Y (Optional) ASTM wood
sheathing D41 PI
self_ ASTM D41 structural concrete
Colphene FR GR (Optional) Elastocol Dens Deck Prime or SECUROCK Gypsum -
adhering Insulation Stick Zero Fiber Roof Board
Base Sheet (Optional) Elastocol ASTM D226, Type II felt or Modified Sopra-
Stick Zero G
RESISTO LB1236, Grip -Rite Eave Existing sand -surfaced, glass -fiber surfaced,
& Valley Protector or TopShield self- Existing RESISTO EXTERIOR
adheringsubstrate PRIMER mineral -surfaced or film -surfaced roof
ICE & WATER DEFENDER underlayment*
* Final acceptance of any existing substrate in a reroof (tear off) installation is at the discretion of the installerand the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave &
Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocoi Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or 0S13 prior to installation of the
self -adhering underlayment
' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval far Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report 518010.06.09-1118
Certificate of -Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-RZO
Soprema Roof Underlayments Revision 18: 0911712020
Page 5 of 8
5.$ Attachment Limitations: MEMO I etc.
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but — for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1 (for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tiie Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -45.0 sf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self -adhered.
#2 Maximum Design
Pressure = -67.5 sf:
Deck:
Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer:
Elastocol Stick Zero
Underlayment:
Lastobond TU HT, self adhered.
#3 Maximum Design
Pressure = -120.0 psf:
Deck:
Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer:
(Optional) RESISTO EXTERIOR PRIMER
Base Ply:
RESISTO SA 5MOOTH PLY 40, self -adhered.
Underlayment:
Lastobond TU HT, self -adhered.
44 Maximum Design
Pressure = -150.0 sf:
Deck:
Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer:
(Optional) RESISTO EXTERIOR PRIMER
Underlayment:
Lastobond TU HT, self -adhered.
#5 All other direct
-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of -45 psf.
NEW ETC, LLC Evaluation Report 518010-06.09-R18
CerrificateofAuthwization#32455 7" EDITION (2020) FBC NON-HVHZ EVALUATION F1.2569-11120
Soprema Roof Underlayments Revision 18: 0911712020
Page 6 of 8
5.8.3.2 Mechanically -Attached Base Sheet: NNEMOJetc.
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida Nigh Wind Concrete and Clay Roof Tile Installation Monual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
(imitations set forth in Section 2.2,10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps f FBC 1517.5.2) spaced 6-
inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT, self -adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
5.10 Tile slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
ent
Lastobond TU HT
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Tile Profile Staging Method
Flat Max. 10-tile stack
Lugged Max. 10-tile stack
Max. 10-tile stack (bottom 2-tile stack shall be inverted,
followed by 8 tiles high on slope, as shown below)
Lugged
Maximum Sio
6:12
5:12
6:12
NEMO ETC, LLC Evaluation Report S18010.06.09-1118
£ertifrcoteofAuthorization#32455 77" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R20
50prema Roof Underlayments Revision 18: 09/17/2020
Page 7 of 8
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment I Tile Profile
MEMO I etc,
Maximum
LColphene FR GR Flat Max. 10-tile stack 5:12
Lugged Max. IC -tile stack 6:12
STALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
Staging Method
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -
adhering underlayment in a reroof (tear -off) application atop an existing underlayment (per Table 2) requires
priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a
reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a
question arise as to the suitability of an existing substrate to receive RESISTO L81236, Grip -Rite Eave & Valley
Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S, Enviro5hield, Lastobond laves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond
Smooth Seal HT, Grip -Rite Smooth Seal HT, RESISTO L131236, Grip -Rite Eave & Valley Protector, TopShield ICE &
WATER DEFENDER, RESISTO LB1244 or Colphene FR GR:
6.3.1 Non -Tile Applications.
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FEIC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type 11 felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or 11905.1.1.
6.3.2 Tile Applications:
Limited to Lastobond TU HT or Colphene FR GR.
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida
Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
Refer to7.8.2 for attachment limitations.
Refer to Table 4 for tile staging limitations.
7. BUILDING PERMIT REQUIREMENTS'
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. 'MANUFACTURING PLANTS.,
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALiTy ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k,chancellor@us.ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report S18010.06.09-1118
Certificate ofAuthorizatian #32455 7T" EDITION (2UZO) FBC NON-HVHZ EVALUATION FL2569-R20
Soprema Roof Underlayments Revision 19: 09/17/20ZO
Page 9 of 8