Loading...
HomeMy WebLinkAboutEngineers615 SW Biltmore Street Port St. Lucie, Florida 34983 8-1050 Nutting Toll ee:877-NUTTING (688-8464) Toll Fr E Engineers 049 561-73 Palm Beach 561-736-4900 Palm Beach Broward 954-941-8700 of Florida inc. I Established 1967 Miami -Dade 305-557-3083 Your Project is our Commitment www.nutthigengineers.com January 24, 2017 Mr. Rich Barnes Bodax Foundations, Inc. v 1101 NW 551" Street E Ft. Lauderdale, Florida 33309 0 Subject: Report of Augercast Pile Installation Monitoring "' Proposed Residence and Pool 7900 South Ocean Drive ° Jensen Beach, Florida u a� ° Dear Mr. Barnes: c CNutting Engineers of Florida, Inc. (NE) has completed observation of augercast piling operations 0) for the proposed residence and pool at the subject site. Bodax Foundations, Inc. installed cast -in- place augured piles for support of the proposed construction. a, Bodax Foundations, Inc. installed a total of 60, 16-inch diameter augercast piles for the project. The piles were installed from January 18, 2017 to January 23, 2017. Please refer to the pile plan v for the numbering provided to our office. The pile size and depth recommendations were based upon our review of the Report of Geotechnical Exploration prepared by GFA International dated w June 24, 2016. The pile installation characteristics of each pile are presented in the attached Pile Installation W Data. Identification of each pile location followed by the pile number is shown on the Pile Location Plans attached. Each pile record in the attached summary tables shows the following c information: 0 ■ RECORD NUMBER IN CHRONOLOGICAL ORDER 'a THE PILE NUMBER (AS, FOUND ON .ATTACHED PLANS) o ■ THE DIAMETER OF THE PILE -0 THE LENGTH OF PILE FROM GROUND SURFACE TO TIP THE THEORETICAL VOLUME OF GROUT FOR THE PILE ■ THE NUMBER OF PUMP STROKES FOR THE PILE ■ THE ACTUAL VOLUME OF GROUT FOR THE PILE THE GROUT FACTOR ., ■ THE DATE OF INSTALLATION ■ THE REINFORCEMENT TYPES OFFICES Palm Beach nV Miami -Dade 1 CAL&GOS Copy St. Lucie ■ AND GENERAL COMMENTS AS NEEDED The drilling operations were monitored in the field by our field engineer and inspector in order to approximately determine the type of material being penetrated. This identification was done based on the augering time, the materials received during the drilling operations and the relative hardness of the soils/rocks as indicated by the vibration or "chattering" of the hydraulic lines. The augercast piles were installed to depths of thirty feet below the existing ground surface of approximately. The piles were designed for an allowable compressive capacity of 40 tons as required by the structural specifications and the recommendations made by our office. Generally, during the installation of the piles, easy drilling was observed from the ground level to approximately thirty-five feet. Below this depth range hard drilling was encountered to the final tip depth. All house and pool piles received steel reinforcement consisting of full length cage with 6, #6 reinforcing bars with #3 ties spaced 3-inch on center in the top and bottom two feet of the cage and 10-inches on center the remaining length of the pile as stated in the structural documents. We also note that four pool piles were battered 15-degrees as stated on the pile location plan. Upon completion of this inspection process, and review of the recorded data, it is our opinion that the augercast piles installed for the residence and pool attained the required design compressive capacity of 40 tons. The piles that were presently installed were constructed in substantial compliance with the plans and specifications. We note that it was monitored and ensured that the piles began installation at the survey locations provided in the field. If during drilling operations it was discovered that gross deviations from original locations have occurred, the deviation was attempted to be rectified. Nutting Engineers is not responsible for minor deviations which have occurred during drilling operations, along with incorrect surveyed pile locations during piling installation. We also note that some deviations may be due to the augerdrill shifting when attempting to drill through the hard rock or other encountered debris conditions. This condition is beyond the control of the site inspector and undersigned engineer. Our client for this project was: Mr. Rich Barnes Bodax Foundations, Inc. 1101 NW 55`h Street Ft. Lauderdale, Florida 33309 ON Nutting e) Engineers of Florida Inc I Established 1967 2 The contents of this report are for the exclusive use of the client, the client's design & construction team and governmental authorities for this specific project exclusively. Information conveyed in this report shall not be used or relied upon by other parties or for other projects without the expressed written consent of NE. We appreciate this opportunity to work with you on this project and look forward to completing this and future projects with you. Should you have any questions or if we can be of any further assistance, please contact us at your convenience. Respectfully Submitted, NUTTING ENGINEERS OF FLORIDA, INC. Richard C. Wohlfarth, P.E. Director of Engineering Attachments: Pile Location Plans Pile Installation Data LTR BODAX 7900 S-OCN DR JENSEN BEACH ACP CEG Nutting E Engineers of Florida Inca Established 1967 3 47 mo ::j� isle. - `- �_ WW z ono W W I — WN D ILO _. - x •.LnW W >, 270 -0 E,o N niZ Nod I �} I I �y I I =? i �sY I to -;DOm o u rnif I :. AN z�-ct . I �FF . I I lp W ;U my LU -o I •3 I jD 0 0 -0 o } [i I Jipo i u h+c i ,JI po j; �� I tt5 .tt I I r .la •ai � � I 0 :is -01' i V J �• } I N r p I • t� `j � W I I O is I.I W I'I W W Ln I 1'I V O W W if 0 N -NP W POOI by 0iHERS j o o 10, -a W �, p W Cw CD b � a aor g' is 1 t3 m v a' I Q v m. W W o i t UR 141 yyR 9.6� 0 9 (D RS 1 g pr $5 IN i£� R � m o = ajSs I sHs 73Qa b-R' R-ggg $ rL-� rii ' � � ! ' C F fig a gg> d8£ 'n°n fig l££ 14`_- 9. ? ra �oN dNo.ro 191. O � z gig l7 I p p a —1 $ii•�''iaa a>ROE afi t0l 9 ig II yv S Naa£:a e Q ga a �s d ago- 'a ii Y W � Y'+1 y Y I! •! Uj Brodock Residence Auger -Gast Piun HMGKP, Md;UMB & ASSOCIATES, INC. rg ooNMMG INGIMMS anv runNxs lu ; Diamond Sands Lot ] Layout & Death Jrnsen Br*IN S.M. �+munm,wuuana}wm,a•orw Im�19 49-10ll PILE TO BE PLACED ON 15% ANGLEOUTWARDFROA7 BOWOSIOFP0OLSHELL- 61-211 TYP 4 PLACES AS SHOWN 121 T 6' if CK POOL 12" TMCK ---- AND PAWALLS I POOLFLOOR 6141/ 13'OLLAUGERCAS uumm 10 TON OFSIGN CAP, I10 TON ULTDIATE C 11-811 tin 12' — — — 4'd1" DEPTH 6'-2" �P - 61-1011 6" WIDE HAUNCH FOR POOLDECK -491-611 BODAX FOUNDATIONS Proposed Residence and Pool 7900 South Ocean Drive Jensen Beach, Florida PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Record No. Pile No. Pile Dia. (in) Pile Length (ft) Theoretic. Pile Volume a (ft) Pump Strokes Total Volume of Grout Pumped ft3 Grout Factor Date Installed Remarks 1 60 16.0 30 1 41.9 63 58.0 1.38 1 01/18/17 Pool/Batter 2 59 16.0 30 41.9 63 58.0 1.38 01/18/17 Pool/Batter 3 56 16.0 30 41.9 68 62.6 1.49 01/18/17 Pool/Batter 4 57 16.0 30 41.9 82 75.4 1.80 01/18/17 Pool/Batter 5 54 16.0 30 41.9 56 51.5 1.23 01/18/17 6 53 16.0 30 41.9 54 49.7 1.19 01/18/17 7 52 16.0 30 41.9 59 54.3 1.30 01/18/17 8 30 16.0 30 41.9 58 53.4 1.27 01/18/17 9 37 16.0 30 41.9 92 84.6 2.02 01/18/17 10 29 16.0 30 41.9 63 58.0 1.38 01/18/17 11 28 16.0 30 41.9 65 59.8 1.43 01/18/17 12 27 16.0 30 41.9 73 67.2 1.60 01/18/17 13 40 16.0 30 41.9 52 47.8 1.14 01/18/17 14 21 16.0 30 41.9 63 58.0 1.38 01/18/17 15 23 16.0 30 41.9 66 60.7 1.45 01/18/17 16 34 16.0 30 41.9 57 52.4 1.25 01/19/17 17 32 16.0 30 41.9 63 58.0 1.38 01/19/17 18 12 16.0 30 41.9 70 64.4 1.54 01/19/17 19 38 16.0 30 41.9 93 85.6 2.04 01/19/17 20 15 16.0 30 41.9 57 52.4 1.25 01/19/17 21 16 16.0 30 41.9 53 48.8 1.16 01/19/17 22 11 16.0 30 41.9 60 55.2 1.32 01/19/17 23 58 16.0 30 41.9 93 85.6 2.04 01/19/17 Pool 24 55 16.0 30 41.9 81 74.5 1.78 01/19/17 Pool 25 24 16.0 30 41.9 63 58.0 1.38 01/19/17 26 61 16.0 30 41.9 62 57.0 1.36 01/19/17 27 42 16.0 30 41.9 53 48.8 1.16 01/19/17 28 26 16.0 30 41.9 59 54.3 1.30 01/19/17 29 41 16.0 30 41.9 97 89.2 2.13 01/19/17 30 35 16.0 30 41.9 57 52.4 1.25 01/23/17 31 51 16.0 30 41.9 55 50.6 1.21 01/23/17 32 50 16.0 30 41.9 63 58.0 1.38 01/23/17 33 49 16.0 30 41.9 60 55.2 1.32 01/23/17 34 33 16.0 30 41.9 54 49.7 1.19 01/23/17 35 2 16.0 30 1 41.9 54 49.7 1.19 01/23/17 36 3 16.0 30 41.9 56 51.5 1.23 01/23/17 37 4 16.0 30 41.9 53 48.8 1.16 01/23/17 38 5 16.0 30 41.9 62 57.0 1.36 01/23/17 39 6 16.0 30 41.9 58 53.4 1.27 01/23/17 40 7 16.0 30 41.9 71 65.3 1.56 01/23/17 41 45 16.0 30 1 41.9 60 55.2 1.32 01/23/17 Nutting Engineers of Florida Inc. I Established 1967 BODAX FOUNDATIONS Proposed Residence and Pool 7900 South Ocean Drive Jensen Beach, Florida PILE LOG DATA OF AUGERCAST PILE INSTALLATION NUTTING ENGINEERS OF FLORIDA, INC. Record No. Pile No. Pile Q1a. (In) Pile Length (ft) Theoretic. Pile Volume (ft) Pump Strokes Total Volume ofGrout Grout Pumped ft Factor Date Installed Remarks 42 43 16.0 30 41.9 55 ' 50.6 1.21 01/23/17 43 44 16.0 30 41.9 56 51.5 1.23 01/23117 44 48 16.0 30 41.9 58 53.4 1.27 01/23/17 45 10 16.0 30 41.9 88 81.0 1.93 01/23/17 46 25 16.0 30 41.9 50 46.0 1.10 01/23/17 47 39 16.0 30 41.9 51 46.9 1.12 01/23/17 48 1 16.0 30 41.9 50 46.0 1.10 01/23/17 49 8 16.0 30 41.9 65 59.8 1.43 01/23/17 50 9 16.0 30 41.9 58 53.4 1.27 01/23/17 51 46 16.0 30 41.9 60 55.2 1.32 01/23/17 52 47 16.0 30 41.9 82 75.4 1.80 01/23/17 53 36 16.0 30 1 41.9 72 66.2 1.58 01/23/17 54 22 16.0 30 41.9 83 76.4 1.82 01/23/17 55 18 16.0 30 41.9 78 71.8 1.71 01/23/17 56 20 16.0 30 41.9 80 73.6 1.76 01/23/17 57 19 16.0 30 41.9 75 69.0 1.65 01 /23117 58 13 16.0 30 41.9 60 55.2 1.32 01/23/17 59 14 16.0 30 41.9 55 50.6 1.21 01/23/17 60 17 16.0 30 41.9 97 89.2 2.13 01/23/17 Redrill Total linear feet drilled 1800 Total Grout VoL. (yd) 133 PILE LOG BODAX 7900 S-OCN DR JENSEN ACP CEG Minimum depth drilled 30 Maximum depth drilled 30 ON Nutting E Engineers of Florida Inc I Established 1967 Florida's Leading Engineering Source Environmental o Geotechnical • Construction Materials Testing ^ Threshold & Special Inspections • Private Provider Services & Code Compliance Revised May 26, 2016 Phoenix Realty Homes Attn: Alan Tarpell 1760 N. Jog Road, Suite 140 West Palm Beach, Florida 33411 Phone: 561-799-5900 Email: fran@phoenixcompaniesfl.com Re: Proposal for Geotechnical Exploration for Proposed Residence 7900 S Ocean Dr (Lot 1 Diamond Sands) South Hutchinson Island, St. Lucie County, Florida Proposal No.16-1291.00 Dear Mr. Tarpell: Per our discussions, GFA International, Inc. is pleased to submit this proposal for performing a geotechnical exploration for the referenced project. We understand the project comprises a 3-level residential structure with a parking level and 2 living levels above, and swimming pool. The site is seaward of the 1987 Coastal. Construction Control Line (CCCL), and a piling foundation is required. Our proposal is based on the site being accessible to our truck -mounted drill rig. If there are underground utilities near the boring locations, we should be notified prior to our field work to take the necessary precautions. GFA cannot be responsible for underground utilities or structures not identified to us. Our report will include the results of our field exploration, recommendations for pile design, and a recommended site preparation procedure. Description Rate Est. Estimated Total Mobilization Mobilization/Demobilization $250.00 1 $250.00 Test Borings 1 x 45-foot Test Boring $13.00 ft 45 $585.00 Engineering Coordination Evaluation and Report Senior Project Engineer $105.00. hr 4 $420.00 Estimated Total $1,255.06 OFFICES THROUGHOUT FLORIDA 521 NW Enterprise Drive - Port St. Lucie, Florida 34986 a (772) 924.3575 - (772) 924-3580 (fax) o www.teamgfa.com Geotechnical Exploration — 7900 S Ocean Dr (Lot 1 Diamond Sands), Hutchinson Island 5/26/2016 Proposal No. 16-1291.00 Page 2 of 3 If there are difficult soil conditions encountered, the number of borings and/or boring depths will be increased to obtain sufficient data to provide you with foundation recommendations for the proposed construction. Additional drilling footage and/or engineering time required by the encountered soil conditions will be charged at the same unit rates. You would be notified prior to any work being performed that would result in additional cost. GFA terms are C.O.D. (credit cards are accepted) unless a credit application has been approved or credit has been previously established. If credit is established, our terms will be net-30 days. All GFA services must be paid in full, including final letter, prior to delivery of any Final Letters of Compliance. The pricing contained herein is subject to change if this proposal is not authorized within 90 days from the date of this proposal. If more than 90 days have passed since the date of this proposal, please contact us for an updated proposal. Additional items not listed in this proposal will be quoted upon request. GFA International has appreciated the opportunity to be considered for this project. If you have any questions, please call Craig Van Collie at (772) 924-3575. Respectfully submitted, GFA INTERNATIONAL, INC. Cra%W Va'V CaUt 1 Craig Van Collie Project Coordinator Attachments: GFA's Standard Terms and Conditions Attachments: GFA's Standard Terms and Conditions GFH