HomeMy WebLinkAboutAPPROVED, ICP Adhesives - Polyset211512021 Florida Building Code Online
►'ProfessionalRegulation
Bps Home I Lop In I User Registration Hot Topics I Submit Surcharge ' Slats & Facts Publications contact Us 13cls Site Map LirkS Search
db
d
a0ii—to)
Product Approval
IUSER: Public User
Product Annroval Menu > Product or Application Search > gpolication List > Application Detail
FL # FL6332-R9
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer ICP Adhesives & Sealants, Inc.
Address/Phone/Email 12505 NW 44th Street
Coral Springs, FL 33065
(888) 774-1419 Ext201
rylipelkonen@icpadhesives.com
Authorized Signature Riku Yllpelkonen
rylipelkonen@icpadhesives.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roof Tile Adhesives
Compliance Method Evaluation Report from a Florida Registered Architect or a Utensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/21/2024
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
2 R9 COI 202I NIEMINEN Pdf
Standard
SSTD 11
Year
1997
Product Approval Method
Method 1 Option D
www.floridabuilding.org/pr/pr_app_dti-aspx?param=wGEVXQwtDquanCtKft6f%2fM%2b3ax6XpXuonHOZ5EILMrw°/a3d 1/2
2/15/2021
Florida Building Code Online
Date Submitted 09/29/2020
Date Validated 10/04/2020
Date Pending FBC Approval 10/11/2020
Date Approved 12/15/2020
Summary of Products
FL #
Model, Number or Name
Description
6332.1
POLYSET AH-I60
Dual component expanding polyurethane roof tile adhesive
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6332 R9 II 2020 09 29 FINAL ER POLYSET
Approved for use outside HVHZ: Yes
AH160 FL6332-R9 odf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +n/a/-178
Created by Independent Third Party: Yes
Other: 1.) The design pressure limitation in this application
Evaluation Reports
refers to hip and ridge tiles in one configuration. Refer to Table
FL6332 R9 AE 2020 09 29 FINAL ER POLYSET
2 of ER for all hip and ridge the limitations. 2.) Feld tiles are
AH160 FL6332-R9.pd
deslgned based on overturning moment resistance. Refer to
Created by Independent Third Party: Yes
Table 1 of ER for field the limitations. 3.) Refer to ER Sections 5
for other Limitations of Use.
ME=
Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EED employer. $$0vdaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :; Refund Statement
Under Florida law, emall addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact Me office by phone or by taditional mall. If you have any questions, please Nntact 850.487.1395. *Pursuant to section 455.275(1)
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish ro supply a personal address, please
provide the Department with an email address which can be made available to Me public. To determine If you are a licensee under chapter 455, fi5., please click ham.
Product Approval Accepts:
®IFF] FOREl
Credit Card
Safe
www.floridabuilding.orglprlpr_app d0.aspx?param--wGEVXQvADquanCtKft6fa/a2fM%2b3ax6XpXuonHOZ5EfLMrw%3d 2t2
NEMO l etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION REPORT
ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-R9
12505 NW 4411 Street FL6332-R9
Coral Springs, FL 33065 Date of Issuance: 08/08/2008
(888) 774-1419 Revision 9: 09/29/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 71h Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: POLYSETO AH-160
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
y:
Robert J.M. Nieminen, P.E.
' 0Ts = _ •. ;9 a-3'. The facsimile seal appearing was authorized by Robert
Florida Registration No. 59166, Florida DCA ANE1983
'Jiin4 u8,F,. Meminen,P.E on 09/29/2020. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018, NEMO ETC, LLC
ROOFING COMPONENT EVALUATION: NNEMO I etc.
Product Category: Roofing
Sub -Category:
Roof Tile Adhesives
Compliance Statement:
POLYSETO AH-160, as produced
by ICP Adhesives and Sealants, Inc., has demonstrated
compliance with the following
sections of the 7"' Edition (2020) Florida Building Code through testing in accordance
with the Standards set
forth herein. Compliance is subject to the Installation Requirements
and Limitations /
Conditions of Use set forth
herein.
2. STANDARDS:
Sections
Pro a
Standard
Year
1504.2.1.1
Overturning resistance
SSTD 11
1997
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST 6049)
Static Uplift —SSTD 11
P39740.02.12
02/20/2012
ERD (TST 6049)
Static Uplift —SSTD 11
P39740.11.13-R1
01/02/2015
ICC-ES(EVL2396)
20121BC Compliance
ESR-1709
12/01/2018
Miami -Dade (CER 1592)
HVHZ compliance
17-0322.03
04/27/2017
NEMO (TST6049)
Tensile Adhesion (ridge metal)
41-ECM-20-SSCRT-03
09/29/2020
NEMO(TST6049)
Tensile Adhesion
4p-ICP-20-SSLAP-01
09/29/2020
PRI (TST 5878)
Static Uplift —SSTD 11
ECM-001-02-01
09/21/2001
PRI (TST 5878)
static Uplift —SSTD 11
PFI-006-02-01
05/09/2005
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-006-02-02
05/09/2005
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-007-02-01
10/11/2005
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-008-02-04
02/21/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFI-009-02-03
02/21/2006
PRI (TST 5878)
Static Uplift —SSTD 11
TGRI.001-02-03
10/30/2006
PRI (TST 5878)
Static Uplift —SSTD 11
TGRI-001-02-03
10/30/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFPI-010-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFPI-011-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFPI-012-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFPI-013-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD 11
PFPI-014-02-01
12/07/2006
PRI (TST 5878)
Static Uplift —SSTD 11
ECM-003-02-01
06/13/2008
PRI (TST 5878)
Static Uplift —SSTD 11
ECM-004-02-01
06/13/2008
PRI (TST 5878)
Static Uplift—SSTD 11
ECM-005-02-01
06/13/2008
PRI (TST 5878)
Static Uplift —SSTD 11
ECM-006-02-01
06/13/2008
PRI (TST 5878)
Static Uplift —SSTD 11
ECM-007-02-01
06/13/2008
PRI (TST 5878)
Static Uplift —SSTD 11
ECM-008-02-01
06/13/2008
UL LLC (QUA 9625)
Quality Assurance
Service Confirmation
02/07/2018
UL, LLC. (QUA 9625)
Quality Assurance
Florida BCIS
Current
POLYSET® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed and dispensed from a
dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available In refillable tanks or
disposable cylinders.
NEMO ETC, LLC Evaluation Report 02766.03.06-R9
Certificate of Authorization#32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9
POLYSET' AH-160 Revision 9: 09/29/2020
Page 2 of 20
NEnno I etc.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade
Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or R902 for requirements
and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 This Evaluation Report does not include evaluation of roof edge termination.
5.6 POLYSETO AH-160 may be used with flat, low and high profile tiles having a current Florida Statewide Product
Approval or approved on a local -level by the Authority Having Jurisdiction.
5.7 Field tiles, meeting the limitations of FBC 1609.5.3, using POLYSET• AH-160 are limited to projects having an
Aerodynamic Uplift Moment (Ma), determined in accordance with Table 2HB, 2HC, 2HD, 2GB, 2GC or 2GD of FRSA/TRI
Florida High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition or FBC 1609.5.3, not greater than the
following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published
installation instructions for Adhesive Paddy Placement details.
TABLE 1: FIELD TILES IN POLYSETO AH-160
ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA
(MARGINS OFSAFETYALREADYAPPUED)
Tile (FBC 1609.5.3)
Adhesive Paddy Placement (Section 10)
Allowable
Overturning
Type
Profile
Placement
Paddy Details
Moment
Detail
(ft-lbf)
#1
Independent; Single Paddy, Medium (20-inch, ^30 gram)
60
#2
Independent; Single Paddy, Large (WO -inch, -45 gram)
112
Clay or
Concrete
Flat / Low
Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at the
54
#3
overlap)
#1
Independent; Single Paddy, Medium (20-inch, -30 gram)
39
#2
Independent; Single Paddy, Large (2x10-inch, -54 gram)
67
Clay or
Concrete
Medium
Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at the
58
#3
overlap)
Clay
High
#3
Independent; Single Paddy, Large (2x10-inch, -45 gram)
134
#1
Independent; Single Paddy, Medium (W-inch, - 0 gram)
65
Clay or
#2
Independent; Single Paddy, Large (WO -inch, -63 gram)
109
Concrete
High
Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at tile
40
#3
overlap)
Clay
Barrel
#4
2x10-inch x ^35 gram for pans; 2 @ WO -inch x ^17 gram for cap
147
Concrete
Barrel
#4
2x10-inch x `35 gram for pans; 2 @ WO -inch x `17 gram for cap
107
Clay
Cap atop 2x
#5
Independent: Continuous Paddy (-34 gram/ft)
135
stringer
Concrete
Cap atop 2x
#5
Independent: Continuous Paddy (` 34 gram/ft)
116
stringer
Clay
Cap atop 2x
#6
Interdependent:
105
stringer
Head: One (1) #SO x 2X" screw; Overlap: 1 x 6 inch (-10.5 gram)
Concrete
Cap atop 2x
stringer
#6
I
Interdependent:
Head: One (1) #SO x 2%" screw; Overlap: 1 x 6 inch (" 10.5 gram)
76
NEMO ETC, LLC Evaluation Report 02768.03.06-R9
CeaftWe of Authortzarlon#32455 7"' EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9
POLYSET® AH-160 Revision 9: 09/29/2020
Page 3 of 10
ONEMOletc.
5.7.1 Data in Table 1 relates to installation over a TWO-PLY underlayment system, as detailed in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, using a hot -asphalt -applied, ASTM D6380, Class
M cap sheet (commonly called a'30/90 system').
Alternate underlayment systems are those having a current Florida Statewide Product Approval and/or approved on
a local -level by the Authority Having Jurisdiction, listed specifically for use with POLYSET° AH-160.
5.7.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with
POLYSETO AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the
interdependent multi -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or Testing
Application Standard TAS 101 shall be applied in determining the'allowable overturning moment.
5.8 Hip and ridge tiles using POLYSETO AH-160 are limited to projects having hip/ridge design pressure requirements,
Table 1A of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or the
applicable design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3, not greater than
the following values. Refer tolCPAdhesives and Sealants, Inc. published installation instructions for Adhesive Paddy
Placement details.
TABLE 2: HIP & RIDGE TILES IN POLYSETO AH-160
ALLOWABLE UPLIFT RESISTANCE PERFORMANCE DATA
(MARGINS OFSAFETYALREADYAPPLIED)
Placement
Allowable
Tile
Substrate
Detail
Attachment Details
Design
(Section 10)
Pressure (psf)
Clay
2x PT ridge board
#5
Independent: Continuous Paddy (-34
116
gram/ft)
Concrete
2x PT ridge board
#5
Independent: Continuous Paddy (- 34
107
gram/ft)
Clay
2x PT ridge board
#6
Interdependent: Head: One (1) #10 x 2h"
90
screw; Overlap: 1 x 6 inch ("'10.5 gram)
Concrete
2x PT ridge board
#6
Interdependent: Head: One (1) #10 x 2Y."
56
screw; Overlap: i x 6 inch (-10.5 gram)
Clay or
East Coast Metals "Trim Lock""' (FL5374):
#5
Independent: Continuous Paddy ("'34
173
Concrete
aluminum, Galvalume°or stainless steel
gram/ft)
Clay or
East Coast Metals 'Trim Lock"' Plus"
Independent: Continuous Paddy (^' 34
Concrete
(FL5374): aluminum, GalvalumeO or
#5
gram/ft)
178
stainless steel
Clay
Ridged Systems "Fop Notch" (FL8095)
#5
Independent: Continuous Paddy (^ 32
125
gram/ft)
Concrete
Ridged Systems "Top Notch" (FL8095)
#6
Independent: Continuous Paddy (^' 32
146
gram/ft)
NEMO ETC, LLC Evaluation Report 02768.03.06-R9
Certificate ofAuthodl&ion R32455 7- EDITION (2020) FBC NON.HVHZ EVALUATION FL6332-R9
POLYSETO AH-160 Revision 9: 09/29/2020
Page 4 of 10
ONEMOletc.
6.1 POLYSEr AH-160 and the tile roof assembly shall be installed in accordance with the manufacturers' current
published instructions, but not less than the requirements of FBC 1507.3 and the FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth Edition, subject to the limitations in Section 5.
6.1.1 Installation of POLYSETO AH-260 shall be performed by applicators that hold a valid Qualified Applicator Card
presented by ICP Adhesives and Sealants, Inc.
6.2 Underlayment shall hold current Florida Product Approval for use with tile roofing systems. The underlayment
Product Approval shall specify allowable use with POLYSETO AH-160. The underlayment Product Approval shall
specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table
1A of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or the critical
(highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
6.3 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI Florida High Wind Concrete
and Clay Roof Tile Installation Manual, Sixth Edition. Proprietary hip and ridge metal shall be installed in accordance
with the manufacturer's Florida Product Approval.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Tomball, TX
UL, LLC.—QUA9625; (414) 248-6409; Karen.buchmann@ul.COm
NEMO ETC, LLC Evaluation Report 02768.03.06-R9
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9
POLYSET- AH-160 Revision 9: 09/29/2020
Page 5 of 10
10.1 I DETAIL #1: Independent, Medium Paddy:
Nail through plastic cerner
(when required)
Underlayment °
o
W
®/t 7in. y—.�'2 in. -
Battens optional
Eave Course
''.•
10 in.4 cJ,
�i
Paddy (Beneath rile)
Flat/Low Profile Tile
ONEMOletc.
Nal I through plastic cement
(when required)
Paddy lBeneath Tile)
Underlayment /
Y
71n\�
21n.
Battens optional
I
Eave Closure
Eave Course Fascia
Medium Profile Tile
Nall through plastic cease
(when required)
Paddy (Beneath Tile)
i
Underlayment
IF
71n�
2 in.
Battens optional
\'-..•
v Eave Course, _` _�
Fascia
-r
Weephoie
loin>� in
Eave closure
�2
�• ,f
Drip edge
High Profile Tile
NEW ETC, LLC Evaluation Report 02768.03.06-R9
Certificate of Authorization#32455 7"' EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-119
POLYSETe AH-160 Revision 9: 09/29/2020
Page 6 of 10
10.2 I DETAILM2: Independent, Large Paddy:
IUnder
o
ot0in. \
�i
Flat/Low Profile Tile
NNEMO I etc.
Nall through plastic cement
(when required)
Paddy (Beneath
Battensopticna! ,
10 in.
K—Fave Closure
Fascia
Medium Profile Tile
Na iI th rough plastic ce nt
(when required)
Paddy (Beneath Tile)
IUnderlayment
Minot
2 in.wide \\
Battens
optional
i Eave Course
Fascia
Weephole
t0 in. tin.
Eaveclosure
Drip edge
High ProfileTile
NEW ETC, LLC Evaluation Report 02768.03.06-R9
Certificate of Authorization e32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9
POLYSETe AH-160 Revision 9: 09/29/20ZO
Page 7 of 10
10.3 I DETAIL #3: Interdependent, Two Paddy:
Nail through plastic cement Paddy(betweentilm)
(when required I
Battens optional i
� r Paddy lundertilel
�A Single paddy ,
on top of rile
4 in.
2x4in.
loin.
Flat/Low Profile Tile
NNEMOIetc.
Nall through plastic cement Sing lepaddyundertile
(when required)
Paddy (between tiles)
Battens Paddy (under tile)
Iyoptional
Singlepaddy
on top of tile\ _
4x4in.
x4in.
Single paddy on
underlayment
— o
10 in. �_`" 2in.
Eave Closure
Eave Courze Fascia
Medium Profile Tile
Nall through plastkee
Single paddy under the
(when required)
Paddy lhetween tiles)
Battens
optional c'
Paddy (under tile)
,,.
(
'Y Singlapaddy
on underlayment
4 x4 in.
Single 2x4in.
paddy on
top of tile
Eavecoune
Fascia
Weephole
loin in
Eave closure
.�2
P
Drip edge
High Profile Tile
NEMO ETC, LLC Evaluation Report 02768.03.06-R9
Cer[i(cote ofAuthohzotlfon N32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-Rg
POLYSETe AH-160 Revision 9: 09/29/2020
Page 8 of 10
NNEMO I etc.
10.4 I DETAIL #4: Two Piece Barrel (Cap S. Pan) Tile:
11 Placeermugh adhesive to achieve 65 to 70
in contact with the pan File.
2) Turn Gwen upside down. Place adbealue
IQ in. to t indi in Imm outside saes J cuaerbe.
Instal cmer Ulu.
Ensure 20 to 25 sq. In. connect area
each alde of ..,Ulu
Ease closure
(motar shown)
Remove tap portion of the ease course cover Ills. Abut to second course of
Pan Files. Ensure save end of pan and cover tiles are flush at eave line.
Two Piece Barrel - High Profile Tile
10.5 I DETAIL #5: Hip and Ridge (independent placement):
Ahead oflCP Po4set2AH-140 nuy be eppYd ebwe ds&W To mach lapY*odes.. bed of ICFsPcvI%c1M lWwr T. Rpd4etleeskJ rf"PshwsnAR-ip.aefde sieiwsw
I&1=16c'a an bo,L sides ofOe biptidg, bond. Pphicued be appbed doss the<ma, of ae he.ndae board as pahmaed kydaedabede8l4.ggdueWadd:eiudrs syss.t4+klesm
saw ft. It pmvle wrabcd loclOn. tome bm. el.fi
NEMO ETC, LLC Evaluation Report 02768.03.06-R9
Certificate of Authorization #32455 7- EDITION (2020) FEIC NON-HVHZ EVALUATION FL6332-119
POLYSW AH-160 Revision 9: 09/29/2020
Page 9 of 10
NNEMOletc.
10.6 1 DETAIL #6: Hip and Ridge (interdependent placement):
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 02768.03.06-R9
CeMfirote of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9
POLYSEr AH-160 Revision 9: 09/29/2020
Page 10 of 10