Loading...
HomeMy WebLinkAboutAPPROVED, ICP Adhesives - Polyset211512021 Florida Building Code Online ►'ProfessionalRegulation Bps Home I Lop In I User Registration Hot Topics I Submit Surcharge ' Slats & Facts Publications contact Us 13cls Site Map LirkS Search db d a0ii—to) Product Approval IUSER: Public User Product Annroval Menu > Product or Application Search > gpolication List > Application Detail FL # FL6332-R9 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer ICP Adhesives & Sealants, Inc. Address/Phone/Email 12505 NW 44th Street Coral Springs, FL 33065 (888) 774-1419 Ext201 rylipelkonen@icpadhesives.com Authorized Signature Riku Yllpelkonen rylipelkonen@icpadhesives.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roof Tile Adhesives Compliance Method Evaluation Report from a Florida Registered Architect or a Utensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 01/21/2024 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 2 R9 COI 202I NIEMINEN Pdf Standard SSTD 11 Year 1997 Product Approval Method Method 1 Option D www.floridabuilding.org/pr/pr_app_dti-aspx?param=wGEVXQwtDquanCtKft6f%2fM%2b3ax6XpXuonHOZ5EILMrw°/a3d 1/2 2/15/2021 Florida Building Code Online Date Submitted 09/29/2020 Date Validated 10/04/2020 Date Pending FBC Approval 10/11/2020 Date Approved 12/15/2020 Summary of Products FL # Model, Number or Name Description 6332.1 POLYSET AH-I60 Dual component expanding polyurethane roof tile adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL6332 R9 II 2020 09 29 FINAL ER POLYSET Approved for use outside HVHZ: Yes AH160 FL6332-R9 odf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +n/a/-178 Created by Independent Third Party: Yes Other: 1.) The design pressure limitation in this application Evaluation Reports refers to hip and ridge tiles in one configuration. Refer to Table FL6332 R9 AE 2020 09 29 FINAL ER POLYSET 2 of ER for all hip and ridge the limitations. 2.) Feld tiles are AH160 FL6332-R9.pd deslgned based on overturning moment resistance. Refer to Created by Independent Third Party: Yes Table 1 of ER for field the limitations. 3.) Refer to ER Sections 5 for other Limitations of Use. ME= Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EED employer. $$0vdaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :; Refund Statement Under Florida law, emall addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact Me office by phone or by taditional mall. If you have any questions, please Nntact 850.487.1395. *Pursuant to section 455.275(1) Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish ro supply a personal address, please provide the Department with an email address which can be made available to Me public. To determine If you are a licensee under chapter 455, fi5., please click ham. Product Approval Accepts: ®IFF] FOREl Credit Card Safe www.floridabuilding.orglprlpr_app d0.aspx?param--wGEVXQvADquanCtKft6fa/a2fM%2b3ax6XpXuonHOZ5EfLMrw%3d 2t2 NEMO l etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-R9 12505 NW 4411 Street FL6332-R9 Coral Springs, FL 33065 Date of Issuance: 08/08/2008 (888) 774-1419 Revision 9: 09/29/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: POLYSETO AH-160 LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: y: Robert J.M. Nieminen, P.E. ' 0Ts = _ •. ;9 a-3'. The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 'Jiin4 u8,F,. Meminen,P.E on 09/29/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02018, NEMO ETC, LLC ROOFING COMPONENT EVALUATION: NNEMO I etc. Product Category: Roofing Sub -Category: Roof Tile Adhesives Compliance Statement: POLYSETO AH-160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the following sections of the 7"' Edition (2020) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Sections Pro a Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 3. REFERENCES: Entity Examination Reference Date ERD (TST 6049) Static Uplift —SSTD 11 P39740.02.12 02/20/2012 ERD (TST 6049) Static Uplift —SSTD 11 P39740.11.13-R1 01/02/2015 ICC-ES(EVL2396) 20121BC Compliance ESR-1709 12/01/2018 Miami -Dade (CER 1592) HVHZ compliance 17-0322.03 04/27/2017 NEMO (TST6049) Tensile Adhesion (ridge metal) 41-ECM-20-SSCRT-03 09/29/2020 NEMO(TST6049) Tensile Adhesion 4p-ICP-20-SSLAP-01 09/29/2020 PRI (TST 5878) Static Uplift —SSTD 11 ECM-001-02-01 09/21/2001 PRI (TST 5878) static Uplift —SSTD 11 PFI-006-02-01 05/09/2005 PRI (TST 5878) Static Uplift —SSTD 11 PFI-006-02-02 05/09/2005 PRI (TST 5878) Static Uplift —SSTD 11 PFI-007-02-01 10/11/2005 PRI (TST 5878) Static Uplift —SSTD 11 PFI-008-02-04 02/21/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFI-009-02-03 02/21/2006 PRI (TST 5878) Static Uplift —SSTD 11 TGRI.001-02-03 10/30/2006 PRI (TST 5878) Static Uplift —SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFPI-010-02-01 12/07/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFPI-011-02-01 12/07/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFPI-012-02-01 12/07/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFPI-013-02-01 12/07/2006 PRI (TST 5878) Static Uplift —SSTD 11 PFPI-014-02-01 12/07/2006 PRI (TST 5878) Static Uplift —SSTD 11 ECM-003-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD 11 ECM-004-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-005-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD 11 ECM-006-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD 11 ECM-007-02-01 06/13/2008 PRI (TST 5878) Static Uplift —SSTD 11 ECM-008-02-01 06/13/2008 UL LLC (QUA 9625) Quality Assurance Service Confirmation 02/07/2018 UL, LLC. (QUA 9625) Quality Assurance Florida BCIS Current POLYSET® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available In refillable tanks or disposable cylinders. NEMO ETC, LLC Evaluation Report 02766.03.06-R9 Certificate of Authorization#32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSET' AH-160 Revision 9: 09/29/2020 Page 2 of 20 NEnno I etc. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or R902 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. 5.6 POLYSETO AH-160 may be used with flat, low and high profile tiles having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.7 Field tiles, meeting the limitations of FBC 1609.5.3, using POLYSET• AH-160 are limited to projects having an Aerodynamic Uplift Moment (Ma), determined in accordance with Table 2HB, 2HC, 2HD, 2GB, 2GC or 2GD of FRSA/TRI Florida High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition or FBC 1609.5.3, not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 1: FIELD TILES IN POLYSETO AH-160 ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA (MARGINS OFSAFETYALREADYAPPUED) Tile (FBC 1609.5.3) Adhesive Paddy Placement (Section 10) Allowable Overturning Type Profile Placement Paddy Details Moment Detail (ft-lbf) #1 Independent; Single Paddy, Medium (20-inch, ^30 gram) 60 #2 Independent; Single Paddy, Large (WO -inch, -45 gram) 112 Clay or Concrete Flat / Low Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at the 54 #3 overlap) #1 Independent; Single Paddy, Medium (20-inch, -30 gram) 39 #2 Independent; Single Paddy, Large (2x10-inch, -54 gram) 67 Clay or Concrete Medium Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at the 58 #3 overlap) Clay High #3 Independent; Single Paddy, Large (2x10-inch, -45 gram) 134 #1 Independent; Single Paddy, Medium (W-inch, - 0 gram) 65 Clay or #2 Independent; Single Paddy, Large (WO -inch, -63 gram) 109 Concrete High Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at tile 40 #3 overlap) Clay Barrel #4 2x10-inch x ^35 gram for pans; 2 @ WO -inch x ^17 gram for cap 147 Concrete Barrel #4 2x10-inch x `35 gram for pans; 2 @ WO -inch x `17 gram for cap 107 Clay Cap atop 2x #5 Independent: Continuous Paddy (-34 gram/ft) 135 stringer Concrete Cap atop 2x #5 Independent: Continuous Paddy (` 34 gram/ft) 116 stringer Clay Cap atop 2x #6 Interdependent: 105 stringer Head: One (1) #SO x 2X" screw; Overlap: 1 x 6 inch (-10.5 gram) Concrete Cap atop 2x stringer #6 I Interdependent: Head: One (1) #SO x 2%" screw; Overlap: 1 x 6 inch (" 10.5 gram) 76 NEMO ETC, LLC Evaluation Report 02768.03.06-R9 CeaftWe of Authortzarlon#32455 7"' EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSET® AH-160 Revision 9: 09/29/2020 Page 3 of 10 ONEMOletc. 5.7.1 Data in Table 1 relates to installation over a TWO-PLY underlayment system, as detailed in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, using a hot -asphalt -applied, ASTM D6380, Class M cap sheet (commonly called a'30/90 system'). Alternate underlayment systems are those having a current Florida Statewide Product Approval and/or approved on a local -level by the Authority Having Jurisdiction, listed specifically for use with POLYSET° AH-160. 5.7.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with POLYSETO AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent multi -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the'allowable overturning moment. 5.8 Hip and ridge tiles using POLYSETO AH-160 are limited to projects having hip/ridge design pressure requirements, Table 1A of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or the applicable design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3, not greater than the following values. Refer tolCPAdhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 2: HIP & RIDGE TILES IN POLYSETO AH-160 ALLOWABLE UPLIFT RESISTANCE PERFORMANCE DATA (MARGINS OFSAFETYALREADYAPPLIED) Placement Allowable Tile Substrate Detail Attachment Details Design (Section 10) Pressure (psf) Clay 2x PT ridge board #5 Independent: Continuous Paddy (-34 116 gram/ft) Concrete 2x PT ridge board #5 Independent: Continuous Paddy (- 34 107 gram/ft) Clay 2x PT ridge board #6 Interdependent: Head: One (1) #10 x 2h" 90 screw; Overlap: 1 x 6 inch ("'10.5 gram) Concrete 2x PT ridge board #6 Interdependent: Head: One (1) #10 x 2Y." 56 screw; Overlap: i x 6 inch (-10.5 gram) Clay or East Coast Metals "Trim Lock""' (FL5374): #5 Independent: Continuous Paddy ("'34 173 Concrete aluminum, Galvalume°or stainless steel gram/ft) Clay or East Coast Metals 'Trim Lock"' Plus" Independent: Continuous Paddy (^' 34 Concrete (FL5374): aluminum, GalvalumeO or #5 gram/ft) 178 stainless steel Clay Ridged Systems "Fop Notch" (FL8095) #5 Independent: Continuous Paddy (^ 32 125 gram/ft) Concrete Ridged Systems "Top Notch" (FL8095) #6 Independent: Continuous Paddy (^' 32 146 gram/ft) NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate ofAuthodl&ion R32455 7- EDITION (2020) FBC NON.HVHZ EVALUATION FL6332-R9 POLYSETO AH-160 Revision 9: 09/29/2020 Page 4 of 10 ONEMOletc. 6.1 POLYSEr AH-160 and the tile roof assembly shall be installed in accordance with the manufacturers' current published instructions, but not less than the requirements of FBC 1507.3 and the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, subject to the limitations in Section 5. 6.1.1 Installation of POLYSETO AH-260 shall be performed by applicators that hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc. 6.2 Underlayment shall hold current Florida Product Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable use with POLYSETO AH-160. The underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. 6.3 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Tomball, TX UL, LLC.—QUA9625; (414) 248-6409; Karen.buchmann@ul.COm NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSET- AH-160 Revision 9: 09/29/2020 Page 5 of 10 10.1 I DETAIL #1: Independent, Medium Paddy: Nail through plastic cerner (when required) Underlayment ° o W ®/t 7in. y—.�'2 in. - Battens optional Eave Course ''.• 10 in.4 cJ, �i Paddy (Beneath rile) Flat/Low Profile Tile ONEMOletc. Nal I through plastic cement (when required) Paddy lBeneath Tile) Underlayment / Y 71n\� 21n. Battens optional I Eave Closure Eave Course Fascia Medium Profile Tile Nall through plastic cease (when required) Paddy (Beneath Tile) i Underlayment IF 71n� 2 in. Battens optional \'-..• v Eave Course, _` _� Fascia -r Weephoie loin>� in Eave closure �2 �• ,f Drip edge High Profile Tile NEW ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization#32455 7"' EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-119 POLYSETe AH-160 Revision 9: 09/29/2020 Page 6 of 10 10.2 I DETAILM2: Independent, Large Paddy: IUnder o ot0in. \ �i Flat/Low Profile Tile NNEMO I etc. Nall through plastic cement (when required) Paddy (Beneath Battensopticna! , 10 in. K—Fave Closure Fascia Medium Profile Tile Na iI th rough plastic ce nt (when required) Paddy (Beneath Tile) IUnderlayment Minot 2 in.wide \\ Battens optional i Eave Course Fascia Weephole t0 in. tin. Eaveclosure Drip edge High ProfileTile NEW ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization e32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSETe AH-160 Revision 9: 09/29/20ZO Page 7 of 10 10.3 I DETAIL #3: Interdependent, Two Paddy: Nail through plastic cement Paddy(betweentilm) (when required I Battens optional i � r Paddy lundertilel �A Single paddy , on top of rile 4 in. 2x4in. loin. Flat/Low Profile Tile NNEMOIetc. Nall through plastic cement Sing lepaddyundertile (when required) Paddy (between tiles) Battens Paddy (under tile) Iyoptional Singlepaddy on top of tile\ _ 4x4in. x4in. Single paddy on underlayment — o 10 in. �_`" 2in. Eave Closure Eave Courze Fascia Medium Profile Tile Nall through plastkee Single paddy under the (when required) Paddy lhetween tiles) Battens optional c' Paddy (under tile) ,,. ( 'Y Singlapaddy on underlayment 4 x4 in. Single 2x4in. paddy on top of tile Eavecoune Fascia Weephole loin in Eave closure .�2 P Drip edge High Profile Tile NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Cer[i(cote ofAuthohzotlfon N32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-Rg POLYSETe AH-160 Revision 9: 09/29/2020 Page 8 of 10 NNEMO I etc. 10.4 I DETAIL #4: Two Piece Barrel (Cap S. Pan) Tile: 11 Placeermugh adhesive to achieve 65 to 70 in contact with the pan File. 2) Turn Gwen upside down. Place adbealue IQ in. to t indi in Imm outside saes J cuaerbe. Instal cmer Ulu. Ensure 20 to 25 sq. In. connect area each alde of ..,Ulu Ease closure (motar shown) Remove tap portion of the ease course cover Ills. Abut to second course of Pan Files. Ensure save end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile 10.5 I DETAIL #5: Hip and Ridge (independent placement): Ahead oflCP Po4set2AH-140 nuy be eppYd ebwe ds&W To mach lapY*odes.. bed of ICFsPcvI%c1M lWwr T. Rpd4etleeskJ rf"PshwsnAR-ip.aefde sieiwsw I&1=16c'a an bo,L sides ofOe biptidg, bond. Pphicued be appbed doss the<ma, of ae he.ndae board as pahmaed kydaedabede8l4.ggdueWadd:eiudrs syss.t4+klesm saw ft. It pmvle wrabcd loclOn. tome bm. el.fi NEMO ETC, LLC Evaluation Report 02768.03.06-R9 Certificate of Authorization #32455 7- EDITION (2020) FEIC NON-HVHZ EVALUATION FL6332-119 POLYSW AH-160 Revision 9: 09/29/2020 Page 9 of 10 NNEMOletc. 10.6 1 DETAIL #6: Hip and Ridge (interdependent placement): - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 02768.03.06-R9 CeMfirote of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL6332-R9 POLYSEr AH-160 Revision 9: 09/29/2020 Page 10 of 10