Loading...
HomeMy WebLinkAboutAPPROVED,Verea Spanish S NOA - Type of tile Circled5/19/2021 Florida Building Code Online Business Professional Regulation 9CIS Home Log In U— Registration Hot Topics Submit Surcharge scats & Facts Publ—t—s Contact us 8= 5 t Mtq j LWAM I SGWO I (1 11Product Approval dbpr k USER Public User PrWjj Cl Aopr—al Menu > Product or Anpltcauon Search > Apphcatlon List Application Detail FL - FL17152-R4 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer CERAMICA VEREA, S.A. Address/Phone/Email 7035 SW 44 STREET Miami, FL 33155 (786) 641-9154 Ext 000000 rooftile@hotmail.com Authorized Signature Manuel 1. Menendez rooftile@hotmaii.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Tiles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2099 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL17152 R4 COI CV14001 4 2020 FBC Eval Tile final.pdf Referenced Standard and Year (of Standard) Standard ASTM C 1167 TAS 101 Equivalence of Product Standards Certified By Sections from the Code Year 2011 1995 Product Approval Method Method 1 Option D https://www.Roridabuilding.orgipr/pr_app_dti.aspx?param=wGEVXQwtDgvCo3EapillBWAmIsLrOzOHXIaBS5xCPcAa2jwxjG42tw%3dn/o3d 1r'2 5119/2021 Florida Building Code Online Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL tf Model, Number or Name 17152.1 VEREA Clay Roof Tiles Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use 08/28/2020 09/02/2020 09/18/2020 12/15/2020 Description Flat, Barrel, and Spanish S clay roof tiles Installation Instructions FL17152 R4 11 CV14 01.4 2020 FBC Evel Tile final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL17152 R4 AE CV14001.4 2020 FBC Eval Tilefinal.pdf Created by Independent Third Party: Yes Contact Us :: 2601 filair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 Tl:c State of Florida is an AA/EEO employer. Copyright 2007-2013 State o' 1 Will :: Privacy Statement :: A[cessibdiq-5jatement :: Relund Stalement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.139S. *Pursuant to Section 455.275(1). Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official Communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please Provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ®®®EI Credit Card Safe hops:/twww.iloridabuilding.org/pr/pr_app_dli.aspx?param=wGEVXQwtDgvCo3EapillBWAlnisLrOzOHX]aBS5xCPcAa2jwxjG42tw%3d%3d 2/2 CREEK TECHNICAL SERVICES, LLC Certificate of Authorization No, 29824 17520 Edinburgh Dr Tampa, FL 33647 (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7"' EDITION (2020) Manufacturer: VEREA CLAY TILE Issued August 12. 2020 7275 NW 61 Street Miami, FL (786)641-9154 www.VereaClayTile.com Manufacturing Plants: Mesia (La Coruna), Spain Quality Assurance: Keystone Certifications, Inc. (QUA1824) SCOPE Category: Roofing Subcategory: Roofing Tiles Code Edition: Florida Building Code, 7"' Edition (2020) including High -Velocity Hurricane Zones (HVHZ) Code Sections: 1507.3.4, 1507.3.8, 1523.6.5.2, 1523.6.5.2.2. 1523.6.5.2.3 Properties: Physical Properties REFERENCES Entity Report No. Standard Year American Test Lab of South Florida Inc (TST3782) RT0621.01-16 ASTM C 1167 2011 American Test Lab of South Florida Inc (TST3782) RT0621.01-16 Rev 1 ASTM C 1167 2011 American Test Lab of South Florida Inc (TST3782) RT0621.02-16 ASTM C 1167 2011 American Test Lab of South Florida Inc (TST3782) RT0621.02-16 Rev 1 ASTM C 1167 2011 American Test Lab of South Florida Inc (TST3782) RT0710.01-14 ASTM C 1167 2011 American Test Lab of South Florida Inc (TST3782) RT0710.02-14 ASTM C 1167 2011 American Test Lab of South Florida Inc (TST3782) RT1013.01-16 ASTM C 1167 2011 American Test Lab of South Florida Inc (TST3782) RT1013.02-16 ASTM C 1167 2011 American Test Lab of South Florida Inc (TST3782) RT1013.03-16 ASTM C 1167 2011 American Test Lab of South Florida Inc (TST3782) RT1220.01-13 ASTM C 1167 2011 American Test Lab of South Florida Inc ('TST3782) RT0131.01-14 TAS 101 1995 PRODUCT DESCRIPTION Clay Barrel Roof Tile ASTM C 1167, Type I -High Profile. Grade 1 two-piece clay roof tile. Clay Spanish "S" Roof Tile ASTM C 1167, Type I -High Profile, Grade 1 clay roof tile. Clay Flat Roof Tile ASTM C 1167, Type III -Flat Profile, Grade 1 clay roof tile. CV14001.4 FL17152-R4 Page 1 of 6 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein,. CREEK - TECHNICAL SERVICES, LLC CERAMICA VEREA S.A. Clay Roof Tiles Figure 1. Clay Barrel Roof Tile Figure 2. Clay Spanish "S" Roof Tile Figure 3. Clay Flat Roof Tile CV14001.4 FL17152-R4 Page 2 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES. LLC APPLICATION METHOD CERAMICA VEREA S.A. Clay Roof Tiles System #1 - Installation for Clay Barrel Roof Tile Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance Slope: with the recommendations of the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or RAS 120. Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction Roof Deck: at max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max. 24 in. span; Designed by others in accordance with FBC requirements. Installed in accordance with FBC requirements. For adhesive set attachment of tile with Underlayment: ICP Adhesives Polyset AH-160, the underlayment shall be Hot Mop 30/90 installed as described in RAS 118 Section 3.01. Attachment Installed in accordance with FBC requirements. For mortar set attachment of tile with Quikrele Roof Tile Mortar FL-15. the pan tiles shall be installed with a 8.5-inch o.c. spread set in a minimum 10-inch trowel of mortar placed under the center of the barrel. Cap tiles shall be installed with one-half of a 10" trowel of mortar placed on each inside edge of the pan tile where the cap overlaps. For adhesive set attachment of tile with ICP Adhesives Polyset AH-160. the pan tiles shall be installed with a 11-inch o.c. spread set in a full bed of foam adhesive placed under the center of the barrel. Cap tiles shall be installed with one-half of the foam placed on each inside edge of the pan tile where the cap overlaps. Data for Attachment Calculations Nominal Weight (W) and Aerodynamic Restoring Moments due to Gravity - MQ (ft-Ibf) Dimensions (I x w) Multipliers Direct Deck Roof Tile A (ft ) W (Ibf) L (ft) w (ft) Direct Deck 3":12" 4":12" 5":12" 6":12" >7":12" — Application Barrel I 5.5 1.63 1 0.68 0.26 4.11 4.01 3.87 I 3.69 3.47 Attachment Resistance Expressed as a Moment Pan Tiles Cap Tiles i Mt (ft-Ibf ) Roof Tile AdhesiveT Padd� Paddy Adhesive Paddy Size' Paddy Weight Size Weight - — ICP ICP Barrel Adhesives 2"x10" 34.6 Adhesives 1'x10 i 17.3g 118.3 Polyset Polyset AH-160 AH-160 Ouikrete Quikrete Barrel Roof Tile NA NA Roof Tile NA NA 45.4 Mortar, Mortar, FL-15 FL-15 Notes: 1) Minimum dimensions and weight for adhesive application CV14001.4 FL17152-R4 Page 3 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC CERAMICA VEREA S.A. Clay Roof Tiles System #2 - Installation for Clay Spanish "S" Roof Tile Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance Slope: with the recommendations of the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition or RAS 120. Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction Roof Deck: I at max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max. j 24 in. span; Designed by others in accordance with FBC requirements. Installed in accordance with FBC requirements. For adhesive set attachment of tile with Underlayment: ICP Adhesives Polyset AH-160, the underlayment shall be Hot Mop 30/90 installed as described in RAS 118 Section 3.01. Attachment Installed in accordance with FBC requirements. For adhesive set attachment of tile with ICP Adhesives Polyset AH-160, the tiles shall be set in a minimum 10-inch long x 2-inch wide adhesive paddy placed directly on the 90# underlayment, under the flange of the tile, starting between 2 and 3-inches from the head of the tile. Tiles shall be set with a minimum 3-inch headlap and 2-inch side lap. Data for Attachment Calculations Nominal Weight (W) and Aerodynamic Restoring Moments due to Gravity - M„ (ft-Ibf) Roof Tile Dimensions (I x w) Multipliers Direct Deck k Direct Dec W (Ibf) L (ft) w (ft) Dirit 3":12" 4":12" 5" 12" 6":12" >7":12„ Spanish "S" 8.0 ( 1.63 1 0.90 1 0.31 1 6.33 I 6.20 I 6.05 I 5.87 j 5.68 Attachment Resistance Expressed as a Moment Tile Attachment Mf Roof Tile — Adhesive Paddy Size'— Paddy Weight' (ft-Ibf) Spanish "S" ICP Adhesives Polyset AH-160 I 2"x10" 24.5g I 58.6 Notes: 1) Minimum dimensions ana weight for aonesive appucauon CV14001.4 FL17152-R4 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC CERAMICA VEREA S.A. Clay Roof Tiles System #3 - Installation for Clay Flat Roof Tile Limited to slopes 3:12 or greater in the HVHZ; Outside the HVHZ, shall be in accordance Slope: with the recommendations of the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition or RAS 120, Solid or closely fitted min. 15/32-inch plywood sheathing for new and existing construction Roof Deck: at max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max. 24 in. span; Designed by others in accordance with FBC requirements. Installed in accordance with FBC requirements. For adhesive set attachment of the with Underlayment: ICP Adhesives Polyset AH-160, the underlayment shall be Hot Mop 30/90 installed as described in RAS 118 Section 3.01. Installed in accordance with FBC requirements. For adhesive set attachment of the with ICP Adhesives Polyset AH-160, the tiles shall be set in a minimum 10-inch long x 2-inch Attachment. wide adhesive paddy placed directly on the 90# underayment, underneath the right half of the tile. Tiles shall be set with a minimum 2.125-inch headlap. Data for Attachment Calculations Nominal Weight (W) and Aerodynamic Restoring Moments due to Gravity - Mg (ft-lbf) Dimensions (I x w) Multipliers Direct Deck Roof Tile \ (ft') W (lbf) L (ft) w (ft) Direct Deck 3":12" 4":12" 5":12" 6":12" >7":12" Application I - Flat 6.4 1.29 0.82 0.21 3.77 3.71 3.63 1 3.54 3.44 Attachment Resistance Expressed as a Moment Tile Attachment Roof Tile ---- --.. __ .__-_ - - --..-- Mr (ft-lbf) Adhesive Paddy Size' Paddy Weight' Flat ICP Adhesives Polyset AH-160 2"x10" 24.2g 38.7 Notes: 1) minimum dimensions and weight for adhesive appucation CV14001.4 FL17152-R4 Page 5 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES. LLC LIMITATIONS CERAMICA VERSA S.A. Clay Roof Tiles i ) Fire Classification is not within the scope of this evaluation. 2) Installation of the evaluated products shall comply with FBC Section 1507.3, FRSA/TRl Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's published application instructions. Installations in the HVHZ shall comply with RAS 120. Where discrepancies exist between these sources, the more restrictive detail shall prevail. 3) Design wind load requirements shall be conducted in accordance with FBC Section 1609.5.3 in the non- HVHZ and RAS 127 in the HVHZ, using a moment based system. 4) In the HVHZ. a static field uplift test shall be conducted in accordance with TAS 106. 5) All tiles shall bear the imprint or indelible label "VEREA CE'. 6) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R Priest P.E. Have demonstrated compliance with the Florida Building Code, 7`' Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. `I I I I I I f II I I I,,, •`���PRY R �� C E N S 61 No 74021 c STATE OF ORtO. 'Sis/N AO—,"`, �r11111►i11 CERTIFICATION OF INDEPENDENCE 2020.08.12 17:24:59 Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services. LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT CV14001.4 FL17152-R4 Page 6 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.