Loading...
HomeMy WebLinkAboutGeneral Information Section A,C,DREVIEWED FOR Pik%z FILE COPY ST. LlJ I E WORKS CODE COMPLIANCE RECEIVED f Master Permit No. ST. LUCIE COUNTY BOCC FEB 2 4 2021 Section A (General Information) St. Lucie county Permitting Process No. Contractors Name: r� >LJ� ' snl c\r l CeS TN' C License # CCC13 3 1 SM 3 Job Address R ba-7 "Raso 2O V0le s "B7 Vp �'� ,�i 1 eCC-e ?M451 .LOW Slope ❑ Asphaltic Shingles ❑ New roof ❑ Repair Low Slope Roof Area (SF) &0 ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles OWetal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ Maintenance Reroofing .ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) tog ❑ Recovering Total (SF) Oil L46Q Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. IIIIIIIIIIIIl® S. 2,7-02,- 0603 1 A b ST. L UCIIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: V-'U C-1 I4SS USA Product Approval No.: CjLj — 2 �� j'%� Design Wind Pres�u�s,(� From RAP k Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: d S� Gauge Thickness: Slope: I ' ( Z Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): 1-7 (ltij1-a FI•cy 8 A V Base Sheet Fastener/Bonding Material: 4 Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: 70 I u G ICASS 4W Top, Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':r." oc @ Lap, # Rows_:®` "oc Zone 1 " oc @ Lap, # Rows @ ""Do Zone 2• " oc @ Lap, # Rows @ "ac Zone 3• " oc @ Lap, # Rows— @ "oc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. . 5 It A19 ST. L.UCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Notice of Acceptance Number: �L Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): .Zone 1:-9Zone 2e:"t ozone 2ri 'O Zone 2rll?.�-Zone 3e? Zone 3.r: De6k Type:,, Type.Undeilaymeft f. `Roof Slope: . Insulation ' ,Fire Barrier: Ridge Veritilafi6n? Fastener Type R `8pacing: O D nY� u .Adhesive Typet 1 - P C`y\e C i Y1G. Type` pp $heel Mean RooPHeight: , ;Roof Coveitn'g: �j v Cry TYPO `&'Size Drip Edge: