FL #
FL27499-R4
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived 0
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772)872-8030
juan@dynamicmetal-net
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
FILE COPY
.Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Q Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE-62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Lucas A. Turner, P.E., MBA
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL27499 R4 COI Dyn COI•pdf
Standard
TAS 100
TAS 110
TAS 125
Year
1995
2000
2003
'Z-'Zn Z -- 67,6 4 3
Product Approval Method
Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Go to Page
04/18/2021
04/30/2021
05/03/2021
06/08/2021
0 0 Page 1/ 2 0 0
FL #
Model, Number or Name
Description
27499.1
DM Class 1000 1" Nailstrip
26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
snap fit seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 4991 Dwg_pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 4991 Eval.pdf
Created by Independent Third Party: Yes
27499.2
DM Class 1000 1" Nailstrip,
.032" Aluminum roof panel, 16" wide, with 1" snap fit seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 4992 Dwg_pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 4992 Eval.p!if
Created by Independent Third Party: Yes
27499.3
DM Class 1050 1 1/2" Nailstrip
.032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 R4 II 4993 Dwg,pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, RE. FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 4993 Eval.pdf
Created by Independent Third Party: Yes
27499.4
DM Class 1050 1 1/2" Nailstrip
24 Ga. Galvalume coated steel roof panel, 19" wide, with 1
1/2" snap fit seams
Limits of Use -
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 4994 Dwg,pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure, N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 4994 Eval.pdf
Created by Independent Third Party: Yes
27499.5
DM Class 1150 1" Mechanical Seam
.032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 4995 Dwg,pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62394
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval Report for Limits of Use.
FL27499 R4 AE 4995 Eval.pdf
Created by Independent Third Party: Yes
27499.6
DM Class 1150 1" Mechanical Seam
.032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL27499 R4 II 4996 Dwg,pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62394
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Installation Drawings and Eval Report for
FL27499 R4 AE 4996 Eval.pdf
Limits of Use.
Created by Independent Third Party: Yes
27499.7
DM Class 1150 1" Mechanical Seam
26 Ga. Galvalume coated steel roof panel, 21" wide, with 1"
standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 4997 Dwg_pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62394
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 49915 Dwg,pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 49915 Eval.pdf
Created by Independent Third Party: Yes
27499.16
DM Class 1750 1 3/4" Snaplock
.032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock
seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 49916 Dwg.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 49916 Eval.pdf
Created by Independent Third Party: Yes
27499.17
DM Class 1750 1 3/4" Snaplock
24 Ga. galvalume coated steel roof panel, 18" wide, with 1 3/4"
Snaplock seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 49917 dwg.pd
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 49917 Eval.pd
Created by Independent Third Party: Yes
27499.18
DM Class 2000 2" Mechanical Seam
.032 Aluminum roof panel, 18" wide, with 2" standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 49918 Dwg.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 49918 Eval.Ddf
Created by Independent Third Party: Yes
27499.19
DM Class 2000 2" Mechanical Seam
24 Ga. galvalume coated steel roof panel, 18" wide, with 2"
standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R4 II 49919 Dwg_pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R4 AE 49919 Eval.Rdf
Created by Independent Third Party: Yes
Go to Page �^ Page 1 / 20 0
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. CODyright 2007-2013 State of Florida.:: Privacy. Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850AB7.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
WOLTERS ENGINEERING
.ENGINEERING, DRAFTING, CONSULTING
15211 970, Road N
West Palm Beach; FL 33412
PhtFx: (561) 22&1982
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT).
PRODUCT: DM CLASS 500 26:GA. GALVALUME 5V CRIMP 24" WIDE
ROOF?ANEL (FLPA# 27499 20)
MANUFACTURER:' DYNAMIC METALS, LLC
3201 SE DOMINICA TERRACE
STUART, FL :34997
To 'all concerned,
The OM Class 500 Series 26 Ga. �Galvalume W Crimp 24" Wide Roof Panel, 'manufactured by Dynamic
Metals LLC, _is,ahon-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the
requirements of -Sections 1507A and 1518.9 of the 7th Edition (2020) Florida Building Code. The -panel has been.
tested. per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38450-44 and H2686.02-
450-44, and per TAS 110 by PRI Construction'Materials Technologies; with results shown in test reports VLS-004-
02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing "5VS-HZ" dated 8/1.5/19, signed and sealed by Scott Wolters, PE.
2. Test Reports listed :above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE.
3. Test Reports listed above by PRI Construction 'Materials Technologies, .signed and sealed by Zachary
R Priest, PE:
4. Supplemental'Calculationsto support'5VS-HZ,,signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per'the requirements of FAC Product Approval Rule Chapter.61_G20-3.005
(4). Based on 'the limitations listed below and those provided in the documents above, this product meets all the
requirements of -the 7th Edition (2020) Florida 'B'uild'ing Code generally, 'and chapter'15 specifically, including the
HVHZ provisions.
Limitations: This panel is apprNed'for use inside'and outside ofthe HVHZ.
Overall. Limitations: Maximum Panel Width: 24' (nominal)
Fastener Spacing across panel: 12" (at Overlaps & Center Rib)
Min. Slope: HVHZ: 2712"
Non-HVHZ: %'712" (with Lap Sealant)
3112" (no Lap Sealant)
5PeCIALIZIN6 IN Ir FAC1' F65151AW CUFIAINWAU,5, 51'0pffi?0W5, & WINPOW5
Option #1
Installation
Option #2
Installation
Max. Design Pressure:
-117.75 psf
-206 psf
Fastener Spacing:
4" From Ends,16" Max. O.C.
4" From Ends, 8" Max. O.C.
Min Panel Fasteners:
#10x1 %2" HiLo HWH Screw
with Weather -seal Washer
#10x1 '/2' HiLo HWH Screw
with Weather -seal Washer
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, in areas with windspeeds < 170 mph, 1" round
plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be
used to prevent galvanic reactions.
Underlayment: Minimum ASTM D 226 Type Il, installed and anchored per FBC Section
1507.1.1.1 (min).
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, in areas with windspeeds < 170 mph, 1" round
plastic caps meeting the requirements of FBC Section 1507.1.1.1 may be
used to prevent galvanic reactions.
Minimum Substrate: '/2' (15/32" min) 4-ply CDX Plywood or 3/4" solid wood planks (S.G. = .42
min) nailed to 2x rafters spaced 24" max. on center with 8d ring -shank
nails spaced 6" on center.
Note: The 3/" wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed Architect/Engineer
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
5FI CKIZING IN IMPACT l.'�515fAN1" CUFfAINWALl,5, 5f0i'Vk0Nf5, & WINPOW5
4�: All panel system,perimeters, penetrations, and transitions'to,be
flashed and sealed ;per the :requirements of RAS 133,
5. Rational analysis, provided'bya Florida licensed' ArchiitoduEngineer
per FAS 61 G20;3:005(e), maybe used for project specific approval by
the local authorities having jurisdiction.
'6. Where required by the Florida Building Gode;. panels shall be
permanently labeled with the manufacturer's name andlof logo,:and the
following statement, "Dynamic Metals FL.427499.20, DM Class 500"..
Panel Forming: These panels maybe jobsite roll formed with. the following Dynamic Metals machines, per
approval of 3rd party QA provider, to the dimensions=shown on Drawing' 5VS-HZ:
SSQ-6800617 8SQ'51.50216 880-6810.617
SSQ-6690517 SS.Q-4.560615 SS02-2310920
5VC-0490718 5VC-0360516 S802=2320920
.Re -Roofing: The DM Class: 500 Series 26 Ga. Galvalume 5V'CnMp _24" Wide Roof Panel
may be 'installed over a' single Gayer of existing asphalt ;shingles, provide the existing roof
meets the. requirements of Section 1511 of the Florida Building .Code.
ifyouhave anyquestions or need more information concerning this; approval, please contact me.
Thank you,
/!�4 ��G•E NSF '9`�r,�
No 62854
Scott Wolters
4
FL PE# 62354 STATE 'OF <v�'
'APR 15 2021
s=s�
5MCKIZIN6 1N IMpACT e515fANf CUPfAINV.Vk> '5, ,SrOP, FFPO,NT5; 9 WINpOW5
M,