Loading...
HomeMy WebLinkAboutProduct Approval Metal RoofingYRr RER1lIWED FORM a n?r* r 1"y`+ s X, sGj .Pcv asydrrr"4r �`r rX is ss 'fir � RAG � DES; v®MPLIANCE OUNTY BOCC n BCIS Home 4Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Florida 1 ?c, L On,Product Approval USER: Public User Product Approval Menu > Product or Aopltcatlon Search > Application List > Application Detail R •� t.`5 n` FL # FL27499-R4 Application Type Revision Code Version 2020 Application Status Approved Comments Archived 0 Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772)872-8030 juan@dynamicmetal-net Authorized Signature Lara Jesus juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing FILE COPY .Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Q Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A. Turner, P.E., MBA Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL27499 R4 COI Dyn COI•pdf Standard TAS 100 TAS 110 TAS 125 Year 1995 2000 2003 'Z-'Zn Z -- 67,6 4 3 Product Approval Method Method 1 Option D Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page 04/18/2021 04/30/2021 05/03/2021 06/08/2021 0 0 Page 1/ 2 0 0 FL # Model, Number or Name Description 27499.1 DM Class 1000 1" Nailstrip 26 Ga. galvalume coated steel roof panel, 16" wide, with 1" snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 4991 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4991 Eval.pdf Created by Independent Third Party: Yes 27499.2 DM Class 1000 1" Nailstrip, .032" Aluminum roof panel, 16" wide, with 1" snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 4992 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4992 Eval.p!if Created by Independent Third Party: Yes 27499.3 DM Class 1050 1 1/2" Nailstrip .032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit seams. Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL27499 R4 II 4993 Dwg,pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, RE. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4993 Eval.pdf Created by Independent Third Party: Yes 27499.4 DM Class 1050 1 1/2" Nailstrip 24 Ga. Galvalume coated steel roof panel, 19" wide, with 1 1/2" snap fit seams Limits of Use - Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 4994 Dwg,pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure, N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4994 Eval.pdf Created by Independent Third Party: Yes 27499.5 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 4995 Dwg,pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval Report for Limits of Use. FL27499 R4 AE 4995 Eval.pdf Created by Independent Third Party: Yes 27499.6 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: No FL27499 R4 II 4996 Dwg,pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eval Report for FL27499 R4 AE 4996 Eval.pdf Limits of Use. Created by Independent Third Party: Yes 27499.7 DM Class 1150 1" Mechanical Seam 26 Ga. Galvalume coated steel roof panel, 21" wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 4997 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 49915 Dwg,pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49915 Eval.pdf Created by Independent Third Party: Yes 27499.16 DM Class 1750 1 3/4" Snaplock .032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 49916 Dwg.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49916 Eval.pdf Created by Independent Third Party: Yes 27499.17 DM Class 1750 1 3/4" Snaplock 24 Ga. galvalume coated steel roof panel, 18" wide, with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 49917 dwg.pd Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49917 Eval.pd Created by Independent Third Party: Yes 27499.18 DM Class 2000 2" Mechanical Seam .032 Aluminum roof panel, 18" wide, with 2" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 49918 Dwg.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49918 Eval.Ddf Created by Independent Third Party: Yes 27499.19 DM Class 2000 2" Mechanical Seam 24 Ga. galvalume coated steel roof panel, 18" wide, with 2" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R4 II 49919 Dwg_pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 49919 Eval.Rdf Created by Independent Third Party: Yes Go to Page �^ Page 1 / 20 0 Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. CODyright 2007-2013 State of Florida.:: Privacy. Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850AB7.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: WOLTERS ENGINEERING .ENGINEERING, DRAFTING, CONSULTING 15211 970, Road N West Palm Beach; FL 33412 PhtFx: (561) 22&1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT). PRODUCT: DM CLASS 500 26:GA. GALVALUME 5V CRIMP 24" WIDE ROOF?ANEL (FLPA# 27499 20) MANUFACTURER:' DYNAMIC METALS, LLC 3201 SE DOMINICA TERRACE STUART, FL :34997 To 'all concerned, The OM Class 500 Series 26 Ga. �Galvalume W Crimp 24" Wide Roof Panel, 'manufactured by Dynamic Metals LLC, _is,ahon-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of -Sections 1507A and 1518.9 of the 7th Edition (2020) Florida Building Code. The -panel has been. tested. per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38450-44 and H2686.02- 450-44, and per TAS 110 by PRI Construction'Materials Technologies; with results shown in test reports VLS-004- 02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing "5VS-HZ" dated 8/1.5/19, signed and sealed by Scott Wolters, PE. 2. Test Reports listed :above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE. 3. Test Reports listed above by PRI Construction 'Materials Technologies, .signed and sealed by Zachary R Priest, PE: 4. Supplemental'Calculationsto support'5VS-HZ,,signed and sealed by Scott Wolters, PE. I have reviewed this submittal per'the requirements of FAC Product Approval Rule Chapter.61_G20-3.005 (4). Based on 'the limitations listed below and those provided in the documents above, this product meets all the requirements of -the 7th Edition (2020) Florida 'B'uild'ing Code generally, 'and chapter'15 specifically, including the HVHZ provisions. Limitations: This panel is apprNed'for use inside'and outside ofthe HVHZ. Overall. Limitations: Maximum Panel Width: 24' (nominal) Fastener Spacing across panel: 12" (at Overlaps & Center Rib) Min. Slope: HVHZ: 2712" Non-HVHZ: %'712" (with Lap Sealant) 3112" (no Lap Sealant) 5PeCIALIZIN6 IN Ir FAC1' F65151AW CUFIAINWAU,5, 51'0pffi?0W5, & WINPOW5 Option #1 Installation Option #2 Installation Max. Design Pressure: -117.75 psf -206 psf Fastener Spacing: 4" From Ends,16" Max. O.C. 4" From Ends, 8" Max. O.C. Min Panel Fasteners: #10x1 %2" HiLo HWH Screw with Weather -seal Washer #10x1 '/2' HiLo HWH Screw with Weather -seal Washer Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note #2 below) Note: Outside of the HVHZ, in areas with windspeeds < 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type Il, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami -Dade NOA Note: Outside of the HVHZ, in areas with windspeeds < 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1 may be used to prevent galvanic reactions. Minimum Substrate: '/2' (15/32" min) 4-ply CDX Plywood or 3/4" solid wood planks (S.G. = .42 min) nailed to 2x rafters spaced 24" max. on center with 8d ring -shank nails spaced 6" on center. Note: The 3/" wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 5FI CKIZING IN IMPACT l.'�515fAN1" CUFfAINWALl,5, 5f0i'Vk0Nf5, & WINPOW5 4�: All panel system,perimeters, penetrations, and transitions'to,be flashed and sealed ;per the :requirements of RAS 133, 5. Rational analysis, provided'bya Florida licensed' ArchiitoduEngineer per FAS 61 G20;3:005(e), maybe used for project specific approval by the local authorities having jurisdiction. '6. Where required by the Florida Building Gode;. panels shall be permanently labeled with the manufacturer's name andlof logo,:and the following statement, "Dynamic Metals FL.427499.20, DM Class 500".. Panel Forming: These panels maybe jobsite roll formed with. the following Dynamic Metals machines, per approval of 3rd party QA provider, to the dimensions=shown on Drawing' 5VS-HZ: SSQ-6800617 8SQ'51.50216 880-6810.617 SSQ-6690517 SS.Q-4.560615 SS02-2310920 5VC-0490718 5VC-0360516 S802=2320920 .Re -Roofing: The DM Class: 500 Series 26 Ga. Galvalume 5V'CnMp _24" Wide Roof Panel may be 'installed over a' single Gayer of existing asphalt ;shingles, provide the existing roof meets the. requirements of Section 1511 of the Florida Building .Code. ifyouhave anyquestions or need more information concerning this; approval, please contact me. Thank you, /!�4 ��G•E NSF '9`�r,� No 62854 Scott Wolters 4 FL PE# 62354 STATE 'OF <v�' 'APR 15 2021 s=s� 5MCKIZIN6 1N IMpACT e515fANf CUPfAINV.Vk> '5, ,SrOP, FFPO,NT5; 9 WINpOW5 M,