FILECOPY RECEIVED
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL1654-R28
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
[ 1
FEB 2 4 2021
St. Lucie County
Permitting
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY EOCC
Product Manufacturer POLYGLASS USA
Address/Phone/Email ills W. Newport Center Drive
Deerfield Beach, FL 33442 v Z b�O3
(954) 233-1330 Ext242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polygiass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866).802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Englneer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 11/07/2022
Validated By John W. Knezevich, PE
01 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL1654 R28 COI 2021 01 COI NIEMINEN.pd
Standard
Year
ASTM D4601
2012
ASTM D4897
2009
ASTM D6162
2015
ASTM D6163
2015
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
ASTM G155 (
2013
FM 4470
2016
FM 4474
2011
UL 1897
2012
Method 1 Option D
06/09/2021
06/14/2021
06/18/2021
08/10/2021 '
02/11/2022
FL #
Model, Number or Name
Description
1654.1
Polyglass Modified Bitumen Roof
SBS and APP modified bitumen roof systems
Systems for use in FBC non-HVHZ
jurisdictions.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1654 R28 II 2021 06 09 FINAL Al ER PG MODBIT FL1654-
R28.p IF
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application relates
Evaluation Reports
to one particular assembly over concrete deck. Refer to the
FL1654 R28 AE 2021 06 09 FINAL ER PG MODBIT FL1654-
R28.pdf
ER Appendix for other systems and deck types. 2.) Refer to
ER, Section 5 for other Limits of Use. 3.) Refer to FL16717
Created by Independent Third Party: Yes
for HVHZ jurisdictions.
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyr{ght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls
provided may be used for of Icial communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here .
Product Approval Accepts:
r ,Cf�dlt,Car� .,
::Safe:
O....NEMO l etc.
!�_AppficuiqN�
��,;,,'�,TYPE
'D.ESCRIPTION',-'.
1A
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
6
1B
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
6-12
Ic
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
13-14
ID
Wood
New, Reroof (Tear -Off) or Recover
B-1
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
15
1E
Wood
New, Reroof (Tear -off) or Recover
C-1
Mech. Attached Insulation, Bonded Roof Cover
16-19
1F
Wood
New, Reroof (Tear -Off) or Recover
D-2
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
19-23
1G
Wood
New or Reroof (Tear -Off)
E-2
Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
23-28
1H
Wood
New, Reroof (Tear -Off) or Recover
E-2
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
29-36
�Ii
Woo
_—Rew-or-Reroof-Rear-Off)
F
Non -Insulated, Bonded Roof Cover _
-
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B-1
Mech. Attached Base insulation, Bonded Top Insulation, Bonded Roof Cover
38-43
23
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C-1
Mech. Attached Insulation, Bonded Roof Cover
44-50
2c
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D-2
Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
50-52
2D
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D-2
Insulated, Mech. Attached Velociflex, Bonded Roof Cover
53-54
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
55-69
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
69
4A
Lightweight concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
70-74
4B
Lightweight concrete
New or Reroof (Tear -Off)
A-2,
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
74-76
4c
Lightweight concrete
New or Reroof (Tear -Off)
E-2
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
77-81
5A
Cementitious wood fiber
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
82-83
5B
Cementitious wood fiber
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
83-94
5C
Cementitious wood fiber
Reroof (Tear -Off) or Recover
B-1
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
85
5D
Cementitious wood fiber
Reroof (Tear -Off) or Recover
C-1
Mech. Attached Insulation, Bonded Roof Cover
85
SE
Cementitious wood fiber
Reroof (Tear -Off) or Recover
E-2
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
85
6A
Existing gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
86-90
6B
Existing gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
91
6c
Existing gypsum
Reroof (Tear -Off) or Recover
C-1
Mech. Attached Insulation, Bonded Roof Cover
91
6D
Existing gypsum
Reroof (Tear -Off) or Recover
E-2
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
91
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
92-98
7B
Various
Recover
F
Non -Insulated, Bonded Roof Cover
98
NEMO ETC, U.0 Evaluation Report P9290.02.08-R26 for FL1654-R28
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION Revision 26: 06/09/2021
@2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems, (954) 233-1330 Appendix 1, Page 1 of 98
0-NEMo etc.
The following notes apply to the systems outlined herein:
1 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having
Jurisdiction.
2 Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: Minimum 1-inch plywood penetration or wood plank embedment.
➢ Steel Deck: Minimum 0.75-inch steel penetration and engage the top flute of the steel deck.
➢ Structural Concrete: Minimum 1-inch embedment into pilot hole in accordance with published installation instructions.
3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof
cover.
4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed
through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof
decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purportto address
non -wind -uplift -related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components.
5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020).
6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published
instructions.
➢ Hot asphalt (HA): Full coverage at 25-30 lbs/square.
➢ DuPont INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
➢ H.B. Fuller Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ H.B. Fuller Millennium PG-1 Pump Grade Adhesive (M-PGI): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. Note: OlyBond Classic may be used where OlyBond 500 is referenced.
➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
➢ ICP Adhesive & Sealants Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c.
➢ Note: When multiple loyers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, board joints shall be staggered.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following
Maximum Design Pressure (MDP) limitations.
In no case shall these values be used to'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in
the tables, then the thinner board listed below
may be used as a drop -in for the equivalent thicker material listed in the table.
➢ M-OSFA: MDP = -157.5 psf
(Min. 0.5-inch thick)
➢ M-PG1: MDP = -157.5 psf
(Min. 0.5-inch thick)
➢ OB500: MDP = -45.0 psf
(Min. 0.5-inch thick Multi -Max FA-3)
➢ OB500: MDP = -187.5 psf
(Min. 0.5-inch thick ISO 95+ GL)
➢ OB500: MDP = -315.0 psf
(Min. 0.5-inch thick ENRGY 3)
➢ OB500: MDP = -487.5 psf
(Min. 0.5-inch thick ACFoam II)
➢ Polyset CR-20: MDP = -117.5 psf
(Min.1.D-inch thick)
8 For adhered roof insulation and board -size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020).
For mechanically attached components or partially -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in
accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
NEMO ETC, LLC
Certificate of Authorization #32455
©2018 NEMO ETC, LLC
7- EDITION (2020) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (954) 233-1330
Evaluation Report P9290.02.08-1126 for FL1654-R28
Revision 26: 06/09/2021
Appendix 1, Page 2 of 98
O-NEMOletc.
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements.
10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No
rational analysis is permitted for these systems.
11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be
installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded
insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority
Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional.
Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached priorto roof cover installation (Note 5 herein). The separator
component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications.
14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current
LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the
minimum top -coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWIC references, listings were established through testing
over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO
(FBC CER1592). Use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction.
15 For bonded membrane applications, unless otherwise noted, refer to the following.
MEWIBRANEtADHESIVE;COMBINATIONS'
REFERENCE" ,
LAYER'
;- ' - , , : ',,,MATERIAL
:. < APPLICATION ; =
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II
Hot Asphalt at 20-40
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI
(Base and Ply sheets,
Ibs/square
Asphalt -Applied)
Note.,
Asphalt -applied sheets or insulation shall not be applied to poly -film surfaced membranes.
Base Ply
One ply Elastobase V (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield VP HT
SBS-CAI
Cap Ply
Elastoshield HT G, Elastoshield HT G FR, Elastoflex V G, Elastoflex V G FR, Elastoflex 56, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex
PG350 at 1.5-2.0
gal/square
S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase V (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP
SBS-CA2
Polyplus 35 at 1.5-2.0
gal/square
Ca PI
p y
Elastoshield HT G, Elastoshield HT G FR. Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex
56 G FR, Elastoshleld TS G, Elastoshield TS G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply or Ply
One or more plies Elastobase V (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6,
SBS-AA
Elastoflex S6 HP, Elastoshield VP HT
Hot Asphalt at 20-40
Cap ply
Elastoshield HT G, Elastoshield HT G FR, Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G,
(SBS, Asphalt -Applied)
Ibs/square
Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note.
Asphalt -applied sheets or insulation shall not be applied to poly film surfaced membranes.
Base Ply or Ply
One or more plies Elastobase V (sand/poly), Elastobase V (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield VP
HT, Elastoshield TS
SBS TA
(SBS, Torch -Applied)
Elastoshield HT G, Elastoshield HT G FR, Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex 56, Elastoflex 56 HP, Elastoflex S6
Torch -Applied
Cap Ply
G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film
backed)
NEW ETC, LLC
Certificate of Authorization #32455
02018 NEMO ETC, LLC
7- EDITION (2020) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (954) 233-1330
Evaluation Report P9290.02.08-R26 for FL1654-R28
Revision 26: 06/09/2021
Appendix 1, Page 3 of 98
MEMO j etc.
x: MEMBRANE` ADHESIVE COMBINATIONS.,
LAVER,.., .
MATERIAL - ., r . •:
APPLICATION t. _' ,.,:,
SBS-SA-H
Base Ply
Elastobase SA
Self -adhering (followed
(SBS, Self -Adhering, Hybrid Systems)
by torch -applied sheet)
Base Ply
One or more plies Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V Plus, Elastoflex SA V Plus FR, Elastoflex SA Base HD
SBS-SA
Cap Ply
Elastoflex SAP Elastoflex SA P FR Polyreflect
Self -Adhering
Note
.,-._
Unless otherwise noted, permis;able membrane substrates for SBS SA are limited to the SBS SA Base Ply ootionshere n,
(SBS, Self -Adhering)
Elastobase V or E dstobase P,, wlth a poly: lm`top surface , _.. -F.:
APP-CA1
Ca Ply
P
Polyflex G FR
PG350 at 1.5-2.0
gal/square
APP-TA
Base Ply or Ply
One or more plies Polybase V, Polyflex, Polybond
(APP, Torch -Applied)
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
Torch -Applied
APP-SA-H
Base Ply
Polyflex SA Base
Self -adhering (followed
(APP, Self -Adhering, Hybrid Systems)
by torch -applied sheet)
Cap Ply
Polyflex SA P, Polyflex SA P FR Polyfresko G SA Polyfresko G SA FR
APP-SA
Note
Unless otherwise noted perib ssibie membrane substrates forAAP SA are hm►ted to the SBS SA Base Ply options herein, ='
Self -Adhering
(APP, Self -Adhering)
Eldstobose��VorElasiabasePwith_apoly=lmtops_'urface-„s
16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. those in Table 3A applies.
n„ , ,f ;y' VAPOR BARRIER OPTIONS; STRU6TURAL CONCitETE DE6K, FOLLOVIIEO BY AOHESNE APPLIED,INSULATIONFER
TABLE
=VAPOR BAR� ; TYPE,(NOTEY5APRLICATION
FC-VB-3.
PG100
Elastoflex SA V Plus
Self -Adhering
D-IS or CR-20,12-inch o.c.
-60.0
PG100
Polybase V
Torch -applied
D-IS or CR-20,12-inch o.c.
-75.0
PG100
Elastoflex SA P
Self -Adhering
D-IS, 12-inch o.c.
-75.0
C-VB-4.
PG100
Polyflex or Polybond
Torch -applied
M-OSFA, M-PG-1, OB500 or CR-20, 12-inch o.c.
-121.7
C-VB-S.
PG100
Elastoflex SA P
Self -Adhering
M-OSFA, 12-inch o.c.
-157.5
C-VB-6.
PG100
Polyflex or Polybond
Torch -applied
M-OSFA, M-PG-1, 08500 or CR-20, 6-inch o.c.
-185.0
C-VB-7.
PG100
Elastoflex SA P
Self -Adhering
CR-20, 12-inch o.c.
-270.0
C-VB-B.
PG100
Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V Pius, Elastoflex SA V Plus FR
Self -Adhering
M-OSFA, M-PG-1, OB500 or CR-20, 12-inch o.c.
-240.0
C-VB-9.
PG100
SBS-TA (with sanded -top -surface)
Torch -applied
M-OSFA, M-PG-1, OB500 or CR-20, 12-inch o.c.
-240.0
NEMO ETC, LLC Evaluation Report P9290.02.08-R26 for FL1654-R28
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION 4V Revision 26: 06/09/2021
©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 4 of 98
NEMO j @tc.
17 The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings
for application limitations and a Roofing Materials Directory for fire ratings associated with coating usage.
. -. SURFACING OPTIONS FOkOOLYGUISS:MODIFIED BITUMEN ROOFSYSTEMS "
OPTION# `
,'SURFACING
F.LORiDAPR6DUtTAPPROVAl7,"-"-I
SURF-1.
PG 300
FL10291
SURF-2.
PG 600
FL10291
SURF-3.
PG 650
FL10291
SURF-4.
PG700
FL10291
SU RF-5.
PG 700 QS
FL10291
SURF-6.
PG 800
FL10291
SURF-7.
Polyplus60
FL10291
SURF-8.
Polyplus 65
FL10291
SURF-9.
PolyBrite 60-FC
NOA 20-0611.01
SURF-30.
PolyBrite 70
FL10291
SURF-11.
PolyBrite 70 QS
FL10291
SURF-12.
PolyBrite 75
FL10291
SURF-13.
PolyBrite 71 HS
FL10291
SURF-14.
PolyBrite90
FL10291
SURF-15.
PolyBrite 90.1
NOA 19-0610.02
SURF-16.
PolyBrite 95
FL10291
SURF-17.
PolyBrite 95.1
NOA 19-0610.02
SURF-18.
KM Acryl 15
FL27409
SURF-19.
KM Acryl 15 QS
FL27409
SURF-20.
KM Acryl 25
FL27409
SURF-21.
KM Acryl 25 Q5
FL27409
SURF-22.
KM Acryl 40 HS
FL27409
SURF-23.
KM Acryl 85
FL27409
SURF-24.
KM PS#250
FL27409
SURF-25.
KM PS#220
FL27409
SURF-26.
Turbo -Set
FL10291
18 "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads
MEMO ETC, LLC
Certificate of Authorization #32455
©2018 NEW ETC, LLC
7- EDITION (2020) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems, (954) 233-1330
Evaluation Report P9290.02.08-1126 for FL1654-R28
Revision 26: 06/09/2021
Appendix 1, Page 5 of 98
NEMO etc.
TABLE 1G: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILs), BONDED ROOF COVER
System
'
w_ Base Sheet �� F ', Roof Cover (NoEe;15)
MDP �:
No
kk (Not 1)�
(Psfl
ypel
Fast4--, IN'
- ell
6iii Attic
asey,,
P,
Cap Ply
Min. 15/32-inch
Original Simplex Cap Nails (1-inch metal head
6-inch o.c. at min. 3-inch lap and 6-inch o.c. at
W-105
plywood
Polybase V
diameter, 11 gauge x min. 1.25-Inch long annular
four (4), equally spaced, staggered center rows
None
APP-TA
-52.5
grooved shank)
APA rated, 7/16
CAT, OA18 in.,
8-Inch o.c. at min. 3-inch lap and 8-inch o.c. at
W-106
Exposure 1 OSB or
Elastobase V (sanded top)
Simplex MAXX Cap
three (3), equally spaced, staggered center
None
SBS-AA, SBS-TA,
-60.0
min. 15/32" APA
rows
APP-TA
rated plywood
APA rated, 7/16
CAT, 0.418 in.,
Elastobase V (poly -film
8-inch o.c. at min. 3-inch lap and 8-inch o.c. at
W-107
Exposure 1 OSB or
top)
Simplex MAXX Cap
three (3), equally spaced, staggered center
None
SBS-TA, APP-TA
-60.0
min. 15/32", APA
rows,
rated plywood
APA rated, 7/16
CAT, 0.418 In.,
8-inch o.c. at min. 3-inch lap and 8-inch o.c. at
W-108
Exposure 1 OSB or
Polybase V
Simplex MAXX Cap
three (3), equally spaced, staggered center
None
APP-TA
-60.0
min. 15/32" APA
rows
rated plywood
APA rated, 7/16
CAT, 0.418 in
Elastobase V (poly -film
Simplex MAXX Cap
8-inch o.c. at min. 3-inch lap and 8-inch o.c. at
W-109
Exposure 1 OSB or
op)Note.
top)
MAXX Caps are to be primed with PG100
three (3), equally spaced, staggered center
None
SBS-SA, APP-SA
-60.0
min. 15/32' APA
orASTM D41 primer
rows
rated plywood
Elastobase V, Elastobase P,
Elastovent, Polyglass G2
8-inch o.c. at min. 4-inch lap and 8-inch o.c. at
W-110
Min. 19/32-inch
Base, CertainTeed
32 ga., 1-5/8-inch diameter tin caps with 11 ga.
three (3), equally spaced, staggered center
None
SBS-AA, SBS-TA,
-60.0
plywood
Glasbase, Firestone M13
annular ring shank nails
APP-TA
Base, JM Perma-Ply 28 or
rows
GAFGLAS #75
Min. 19/32-inch
Elastobase V, Elastobase P
32 ga., 1-5/8-inch diametertin caps with 11 ga.
8-inch o.c. at min. 4-inch lap and 8-inch o.c. at
W-111
plywood
(poly -film top)
ring shank nails
annular r
three (3), equally spaced, staggered center
None
SBS-SA, APP-SA
-60.0
rows
W-112
Min. 15/32-inch
Polyglass G2 Base,
Elastobase V, Elastobase P
32 ga., 1-5/8-inch diameter tin caps with 11 ga.
8-inch o.c. at min. 4-inch lap and 8-inch o.c. at
None
SBS-AA, SBS-TA,
-67.5
plywood
or Elastovent
annular ring shank nails
four (4), equally spaced, staggered center rows
I
APP-TA
I I
W-113
Min. 15/32-inch
Polybase V
32 ga., 1-5/8-inch diameter fin caps with 11 ga.
8-inch o.c. at min. 4-Inch lap and 8-Inch o.c. at
I
None
APP-TA
67.5
I
plywood
annular ring shank nails .
four (4), equally spaced, staggered center rows
MEMO ETC, ULC
Certificate of Authorization #32455
@2018 NEMO ETC, LLC
7- EDITION (2020) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (954) 233-1330
Evaluation Report P9290.02.08-R26 for FL1654-1128
Revision 26:06/09/2021
Appendix 1, Page 24 of 98