HomeMy WebLinkAbout2202744-1d compaction signedHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
KSM JOB #:2202744-1d/BS/jo
NUC #456
Nuc Model:MC-1 Elite
Nuc Serial #:31456
4403 Redwood Drive
Fort Pierce, Florida
Compacted Foundation Fill
DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F)
PERCENT
COMPACTION
1 S.W.0" - 12"40 D 106.4 108.7 97.9%
2 N.W."40 D 107.0 "98.4%
3 Center "40 D 106.7 "98.2%
4 N.E."40 D 107.4 "98.8%
5 S.E."40 D 107.1 "98.5%
ITEM TESTED:
JOB LOCATION:
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
DATE TESTED:March 15, 2022
PERMIT #:21100157
CONTRACTOR:Homecrete Homes
TEST LOCATION
OF SAMPLE
Disclaimer: Contractor is responsible to maintain the tested area in
the condition that KSM completed the indicated passed
compaction test. KSM is not responsible if the tested area has
been altered from the approved inspected condition.
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
Proudly Serving Florida since 1990
Certified Women Owned Business - WBE
Soil Description:
Brown Sand
In Place Moisture:
10.4 %
Proctor Optimum Moisture:
10 %
Proctor Max. Dry Density: P.C.F.
108.7
@ Test Locations the Density &
Penetrometer readings indicate the
Degree of Compaction Meets
Minimum Requirement
For an Unstaked Foundation
Respectfully Submitted:
Eric A. McAra, P.E. Office Manager
PE # 69841 3/16/2022
Email to: mshowman@homecretehomes.com
103.0
104.0
105.0
106.0
107.0
108.0
109.0
110.0
5 6 7 8 9 10 11 12 13
W
E
I
G
H
T
P
C
F
D
R
Y
Moisture -% of Dry Weight