Loading...
HomeMy WebLinkAboutAPPROVED, PROJ-70206 - Johnson Residence Sealed (2) APPROVED, PROJ-70206 - Johnson Residence Sealed.pdfDS-08 REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME G-01 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 CODES AND STANDARDS 6505 OCALA AVE, FORT PIERCE, FL 34951 JOHNSON RESIDENCE VICINITY MAP SHEET INDEX G-01 COVER SHEET PROJECT DESCRIPTION: OWNER HOUSE PHOTO A-01 ROOF PLAN S-01 MODULE LAYOUT S-02.1 STRUCTURE CALCULATION E-01 ELECTRICAL LINE DIAGRAM E-02 WIRING CALCULATIONS E-03 SYSTEM LABELING SHEET  SHEET DESCRITION COVER SHEET A-00 NOTES AND DESCRIPTION ELECTRICAL CERTIFICATION:STRUCTURAL CERTIFICATION: DESIGN CRITERIA: WIND SPEED (ULT): 160 MPH WIND SPEED (ASD): 124 MPH RISK CATEGORY: II EXPOSURE: C S-01.1 ARTIAL RESSURE AND MODULES EXOSURE SUNPRO SOLAR 4492 Eagle Falls Place, Tampa, FL 33619 PH: (866) 450-1012 INSTALLER Castillo Engineering Services LLC 620 N. Wymore Road, Suite 250, Maitland, FL 32751 TEL: (407) 289-2575 Ermocrates E. Castillo License#: FL PE 52590 ENGINEER JOHNSON, MIKE21 x380 LG NEON2: LG380N1C-A6 (380) MODULES ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES EQUIPMENT SUMMARY 21 LG NEON2: LG380N1C-A6 (380) MODULES 21 ENPHASE: IQ7PLUS-72-2-US MICROINVERTERS SYSTEM SIZE: 7.980 kW DC STC ARRAY AREA #1: 409.57 SQ. FT. I ERMOCRATES CASTILLO PE# 52590 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 107, THE NEC 2017, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION. I ERMOCRATES CASTILLO PE# 52590 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED., CHAPTER 3. BUILDING STRUCTURE WILL SAFELY ACCOMMODATE WIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS. RACKING: UNIRAC LIGHT RAIL ATTACHMENT: UNIRAC FLASHKIT PRO S-02 ATTACHMENT DETAIL 7.980 kW PV SYSTEM DS-01-08 DATA SHEETS GOVERNING CODES : FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC) FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC) FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC) FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC) NATIONAL ELECTRICAL CODE 2017 (NEC) ASCE 7-16 FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC) PROJECT SITE PROJECT SITE System Description This system is a grid-tied, PV system, with PV generation consisting of 21x380 LG NEON2: LG380N1C-A6 (380W) Modules with a combined STC rated dc output power of 7,980W. The modules are connected into 21 ENPHASE: IQ7PLUS-72-2-US Microinverters. The inverter has electronic maximum power point tracking to maximize energy captured by the PV modules. The inverter also has an internal ground fault detection and interruption device that is set to disconnect the array in the event that a ground fault that exceeds one ampere should occur. The inverter has DC and AC disconnect integrated system and labels are provided as required by the National Electrical Code. When the sun is shining, power from the PV array is fed into the inverter, where it is converted from DC to AC. The inverter output is then used to contribute to the power requirements of the occupancy. If PV power meets the requirements of the loads of the occupancy, any remaining PV power is sold back to the utility. When utility power is available, but PV power is not available, building loads are supplied by the utility. The inverter meets the requirements of IEEE 1547 and UL 1741. Microinverters PV Modules Point of Utility Connection Utility Meter Junction Box Figure 1: PV System Block Diagram Section.............. Elevation ........... Detail ................ Detail ................ (Enlarged Plan) Keyed Notes .......... Ground Terminal ..... Grounding Point/rod.... Solar Panel ......... or Combiner Box .......... AC Disconnect .......... Main Distribution Panel ...................... Fuse ...................... Overcurrent Breaker .. Inverter .................... Transformer ............. Automatic ............... Transfer Switch X X-XX X X-XX X X-XX X X-XX 1 CB ACD MDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Area to be enlarged Keyed note designation on applicable sheet ATS 00 Module with Source Circuit number Vent, Attic fan (Roof obstruction) PV Roof Attachment Trusses Conduit Fire Access UM AC Alternating Current APPROX Approximate AWG American Wire Gauge CB Combiner Box DC Direct Current ACD AC Disconnect DISC Disconnect (E) Existing EL Elevation EQ Equal JB Junction Box MCB Main Combiner Box MFR Manufacturer MIN Minimum MISC Miscellaneous (N) New OCPD OverCurrent Protection Device POCC Point Of Common Coupling PV Photovoltaic SF Squarefoot/feet STC Standard Test Conditions TBD To Be Determined TYP Typical UNO Unless Noted Otherwise VIF Verify In Field WP Weather Proof BatteryBAT Utility meter GP Generation Panel MDP Main Distribution Panel SoladeckSD NAVD North American Vertical datum MID Microgrid Interconnect Device REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME A-00 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 NOTES AND DESCRIPTION Symbols: Abbreviations: 68.5" 41.0" RAILS IN THIS POSITION UNO FALL PROTECTION: ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENT MUST BE INDEPENDENT OF ANY ANCHORAGE BEING USED TO SUPPORT OR SUSPEND PLATFORMS, AND CAPABLE OF SUPPORTING AT LEAST 5,000 POUNDS PER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS: x AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICH MAINTAINS A SAFETY FACTOR OF AT LEAST TWO. x UNDER THE SUPERVISION OF A QUALIFIED PERSON ADDITIONAL INFORMATION x 29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD. x 1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES xxx 1926.502(D)(15) ALLOWABLE/DESIGN PRESSURE PSF DOWN PRESSURE 126 UPLIFT PRESSURE, 2 RAILS 89 LG NEON2: LG380N1C-A6 (380W) MODULES UM MDP CBACD SD 136'-0" 160'-0" 136'-0" 160'-0" 15'-5" 41'-8" 46'-1" 47'-1" REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME A-01 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 ROOF PLAN ROOF PLAN WITH FIRE SETBACKS AND PROPERTY LINESSCALE: 1/16" = 1'-0"A-01 1 OCALA AVE, 1-STORY HOUSE ROOF #1 (21) LG NEON2: LG380N1C-A6 (380W) MODULES (N) (21) ENPHASE: IQ7PLUS-72-2-US MICROINVERTERS FIRE ACCESS AND PATHWAYS AS PER NFPA 1, 11.12.2 (E) SERVICE POINT AND UTILITY METERING (N) SOLADECK - FIRE SETBACK - 3 FT - ZONING SETBACK - 2 FT (N) ENPHASE IQ COMBINER BOX (E) MAIN SERVICE DISCONNECT/ MAIN DISTRIBUTION PANEL EXISTING DRIVEWAY (N) ALTERNATIVE POWER SOURCE AC DISCONNECT/ RAPID SHUTDOWN 3'- 0" FIRE SETBACK 1" IMC, RMC, FMC, LFMC, EMT OR EQUIVALENT CONDUIT RUN 3'- 0" FIRE SETBACK 47'-7" 36'-3" 4'-0" (TYP.) REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME S-01 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 MODULE LAYOUT S-01 SCALE: 3/32" = 1'-0" 1 MODULE LAYOUT GENERAL INSTALLATION PLAN NOTES: 1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED AS SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE: WIND ZONES NON-EXPOSED MODULES EDGE / EXPOSED MODULES SPAN CANTILEVER SPAN CANTILEVER ZONE 1 4' - 0" 1' - 4" 2' - 0" 0' - 8" ZONE 1' X X X X ZONE 2e 4' - 0" 1' - 4" 2' - 0" 0' - 8" ZONE 2n 2' - 0" 0' - 8" 2' - 0" 0' - 8" ZONE 2r 2' - 0" 0' - 8" 2' - 0" 0' - 8" ZONE 3e 2' - 0" 0' - 8" 2' - 0" 0' - 8" ZONE 3r 2' - 0" 0' - 8" 2' - 0" 0' - 8" MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 21 MODULES MODULE TYPE = LG NEON2: LG380N1C-A6 (380W) MODULES MODULE WEIGHT = 41.01 LBS / 18.6 KG. MODULE DIMENSIONS = 68.5" x 41.0" = 19.50 SF UNIT WEIGHT OF ARRAY = 2.10 PSF ARRAY AREA & ROOF AREA CALC'S ROOF ROOF TYPE ARRAY AREA (sq.Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) TILT AZIMUTH TRUSS SIZE TRUSS SPACING #1 ASPHALT SHINGLE 409.57 1122.17 36.50 22.6° 180° 2"X4" 24" O.C. LEGEND - WIND ZONE 1 (TYP) - WIND ZONE 2e (TYP) - WIND ZONE 2n (TYP) - WIND ZONE 2r (TYP) - WIND ZONE 3r (TYP) - WIND ZONE 3e (TYP) (E) FRONT YARD (N) UNIRAC LIGHT RAIL (TYP.) (E) BACK YARD ROOF #1 TILT - 22.6° AZIM. - 180ƒ (53) PV ROOF ATTACHMENT @ 24" & 48" O.C. MAX. (SEE SHEET S-02 FOR ATTACHMENT DETAIL) (SEE SHEET S-01.1 FOR PARTIAL PRESSURE OF THE MODULE) ROOF #1 (21) LG NEON2: LG380N1C-A6 (380W) MODULES (N) (21) ENPHASE: IQ7PLUS-72-2-US MICROINVERTERS SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS. 2) EXISTING RESIDENTIAL BUILDING IS AN ASPHALT SHINGLE ROOF WITH A MEAN ROOF HEIGHT OF 15 FT AND SYP 2"X4" ROOF TRUSSES SPACED 24" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEM RETROFIT IS 22.6 DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD CONDITIONS. 3) FIRE SETBACK TO BE 3' FROM RIDGES AND EDGES, AND 18" EACH WAY FROM HIPS AND VALLEYS PER NFPA 1, 11.12.2. 4) THE EXISTING ROOF AND STRUCTURE WILL NOT BE ADVERSELY AFFECTED DUE TO THE ADDITIONAL LOADS IMPOSED BY THE SOLAR SYSTEM. * I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH FBC: RESIDENTIAL 2020 7TH ED., CHAPTER 3. BUILDING STRUCTURE WILL SAFELY ACCOMMODATE WIND LATERAL AND UPLIFT FORCES AND EQUIPMENT DEAD LOADS. * 16'-10" 16'-0" P1P4 P2P3P6 P5 4'-0" (TYP.) REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME S-01.1 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 PARTIAL PRESSURE AND MODULES EXPOSURE S-01.1 SCALE: 3/32" = 1'-0" 1 ARTIAL RESSURE AND MODULES EXOSURE LEGEND - NON- EXPOSED MODULE - MIN. MODULE EDGE DISTANCE LINE - EDGE MODULE - MODULE EXPOSURE LINE - EXPOSED MODULE - WIND ZONE 1 (TYP) - WIND ZONE 2e (TYP) - WIND ZONE 2n (TYP) - WIND ZONE 2r (TYP) - WIND ZONE 3r (TYP) - WIND ZONE 3e (TYP) NOTE: PARTIAL PRESSURES OF THE WIND ZONES ON ALL MODULES HAVE BEEN VERIFIED AND ARE WITHIN THE ALLOWABLE PER THE MANUFACTURER SPECIFICATION, INSTALLER SHOULD FOLLOW THE LAYOUT TO AVOID HIGHER ZONAL PARTIAL PRESSURES. ANY CHANGES IN LAYOUT SHOULD BE REPORTED BACK TO THE ENGINEER OF RECORD. - MISSING MODULE FOR EXPOSED MODULES 2h2 DISTANCE : 0' - 10" 0.5h DISTANCE : 7' - 6" FOR NON-EXPOSED MODULES ALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS: 89 PSF ROOF #1 (21) LG NEON2: LG380N1C-A6 (380W) MODULES 2h2 (E) FRONT YARD (E) BACK YARD 5" REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME S-02 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 ATTACHMENT DETAIL 2 ATTACHMENT DETAIL (ENLARGED VIEW) S-02 SCALE: 6" = 1'-0" MODULE MID/END CLAMP SOLAR MODULE UNIRAC LIGHT RAIL 5/16"DIA. X 2.5"MIN. EMBEDMENT LAG SCREW AT EACH ATTACHMENT POINT INTO EXISTING FRAMING (E) ROOF SHEATHING ASPHALT SHINGLE ROOF ATTACHMENT DETAIL S-02 SCALE: 1" = 1'-0" 1 2"X4" TRUSSES @ 24" O.C. 2"X4" TRUSS SPANNER FOR MISSED TRUSS ATTACHMENT (IF REQUIRED) UNIRAC L-FOOT UNIRAC LIGHT RAIL GROUNDING MID/END CLAMP 5/16"DIA. X 2.5"MIN. EMBEDMENT LAG SCREW AT EACH ATTACHMENT POINT INTO EXISTING FRAMING FLASH KIT PRO FLASHING 2"X4" TRUSSES @ 24" O.C. SOLAR MODULE hɑ REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME S-02.1 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 STRUCTURE CALCULATION REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME E-01 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 Q CABLES ELECTRICAL LINE DIAGRAM L2 L1 N L2 L1 G N 20A/2P G G (N) SOLADECK 600V, NEMA 3R UL LISTED G G GGGGGG G G L2 L1 L2 L1 (N) 125A ENPHASE IQ COMBINER 3 (X-IQ-AM1-240-3) [WITH UPTO (4) 2-POLE BREAKERS AND ENVOY COMMUNICATION GATEWAY] (N) JUNCTION BOX 600V, NEMA 3R UL LISTED #6 BARE CU WIRE PROTECTED PER NEC 250.64(B) G FACTORY INSTALLED 10A OR 15A BREAKER FOR THE ENVOY PV MODULES ENPHASE: IQ7PLUS-72-2-US MICROINVERTERS G SOLAR ARRAY (7.980 kW-DC STC) (21) LG NEON2: LG380N1C-A6 (380W) MODULES (01) BRANCH OF 11 MODULES (01) BRANCH OF 10 MODULES TO UTILITY GRID L1 L2 N (E) BI-DIRECTIONAL SERVICE POINT AND UTILITY METERING 1-PHASE, 240V EXISTING GROUNDING ELECTRODE SYSTEM L2 L1 L2 L1 G L2 L1 L2 L1 L2 L1 L2 L1 L1 L2 N (E) MAIN BREAKER 200A/2P, 240V N (E) MAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANEL, 225A RATED, 240V 1 ELECTRICAL LINE DIAGRAM E-01 SCALE: NTS L2 L1 L2 L1 N N G G(N) ALTERNATIVE POWER SOURCE AC DISCONNECT/ RAPID SHUTDOWN: 240V, 60AMP RATED, NEMA 3R, UL LISTED LOCKABLE & NON FUSIBLE NOTE: 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC 2017, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, AS APPLICABLE. 2. THE SOLAR PV BACKFED BREAKER IS AT THE END OF THE BUSBAR AND THERE IS NO LUG FED SUB PANEL. 3. REFER SHEET DS-08 FOR LOAD CALCULATIONS. 40A/2P INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED 200A + 40A = 240A BUSS RATING x 120% 225A x 120% = 270A G (3) #6 AWG THWN-2 (1) #6 AWG THWN-2 GND IN 1" PVC, IMC, RMC, LFMC, RTRC, LFNC, EMT OR FMT CONDUIT RUN G G GGGGGG G G L2 L1 L2 L1 L2 L1 20A/2P (2) 10/2 ROMEX RUN IN ATTIC OR(2) #10 AWG THWN-2-RED (2) #10 AWG THWN-2-BLACK EGC #6 AWG THWN-2 GND IN 1" IMC, RMC, FMC, LFMC, EMT OR EQUIVALENT CONDUIT RUN (2) #10 AWG THWN-2-RED (2) #10 AWG THWN-2-BLACK EGC #6 AWG THWN-2 GND IN 1" IMC, RMC, LFMC, PVC, RTRC, LFNC, FMT OR EMT CONDUIT RUN L1 L2 N REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME E-02 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 ELECTRICAL CALCULATION ELECTRICAL NOTES 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75 DEGREE C. 3. THE WIRES ARE SIZED ACCORDING TO NEC 110.14. 4. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 5. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE . 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 17. THIS SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN OF PV CONDUCTORS IN COMPLIANCE WITH NEC 690.12. 18. LABELING IN COMPLIANCE WITH NEC 690.12 AND 690.56(C) IS SHOWN ON SHEET E-03. 19. ALL CONDUITS TO BE INSTALLED A MIN OF 7/8" ABOVE THE ROOF SURFACE. WIRING CALCULATIONS I ERMOCRATES CASTILLO PE# 52590 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 107, THE NEC 2017, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION. UM MDP CBACD REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME E-03 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 SYSTEM LABELING RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: AC DISCONNECT (PER CODE: NEC 690.56(C)(3)) WARNING ELECTRIC SHOCK HAZARD LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.13(B)) TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(B)(2)(3)(b)) WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(B)(2)(3)(b)) ! WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ! TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS AC DISCONNECT PHOTOVOLTAIC SYSTEM MICROINVERTERS LOCATED UNDER EACH PV MODULE IN ROOF TOP ARRAY AC COMBINER BOX LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.54) SOLAR BREAKER LABEL LOCATION: COMBINER BOX (PER CODE: NEC 690.52) LABEL LOCATION: INVERTER (PER CODE: NEC 690.52) LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(B)(2)(3)(b)) NOMINAL OPERATING AC VOLTAGE NOMINAL OPERATING AC FREQUENCYMAXIMUM AC POWERMAXIMUM AC CURRENTMAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUITV VA Hz60 290 A 240 A 1.21 20 LABEL LOCATION: COMBINER BOX (PER CODE: NEC 690.52) DATA PER PANEL LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.54) PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 25.41 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS 7.980 kW SOLAR DISCONNECT LOCATED LABEL LOCATION: MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECT LOCATED NO MORE THAN 3FT (1M) FROM THE SERVICE DISCONNECT (TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8") (PER CODE: NEC 690.56(B), NEC 705.10, NFPA 1, 11.12.2.1) CAUTION! POWER TO THIS BUILDING SUPPLIED FROM MULTIPLE SOURCES EMERGENCY RESPONDER: THIS SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN. TURN RAPID SHUTDOWN SWITCH TO THE ''OFF'' POSITION TO SHUTDOWN ENTIRE PV SYSTEM ADHESIVE FASTENED SIGNS: xTHE LABEL SHALL BE VISIBLE, REFLECTIVE AND SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED [NFPA 1, 11.12.2.1] xWHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. xADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.56(C)(1)(a), IFC 1204.5.1 SERVICE POINT AND UTILITY METERING ENPHASE IQ COMBINER BOX MAIN SERVICE DISCONNECT/ MAIN DISTRIBUTION PANEL ALTERNATIVE POWER SOURCE AC DISCONNECT/ RAPID SHUTDOWN PV SOLAR ARRAY ON ROOF WARNING IN CASE OF EMERGENCY CONTACT: SUNPRO SOLAR PH. NO. - (866) 450-1012 LABEL LOCATION: MAIN DISCONNECT (PER CODE: NFPA - 1, 11.12.2.1.5) ! ! 6505 OCALA AVE, FORT PIERCE, FL 34951 REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME DS-01 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 DATA SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME DS-02 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 DATA SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME DS-03 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 DATA SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME DS-04 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 DATA SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME DS-05 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 DATA SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME DS-06 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 DATA SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME DS-07 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 DATA SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER JOHNSON RESIDENCE PROJECT INSTALLER Signature with Seal ANSI B 11" X 17" DATEDESCRIPTION REVISIONS PROJECT NAME DS-08 CASTILLO ENGINEERING SERVICES, LLC COA # 28345 620 N. WYMORE ROAD, SUITE 250, MAITLAND, FL 32751 TEL: (407) 289-2575 ERMOCRATES E. CASTILLO - FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC 6505 OCALA AVE, FORT PIERCE, FL 34951 DATA SHEET