HomeMy WebLinkAboutAtlas Shingle NOA - 20-0527.05 (8-5-25) (1)
NOA No.: 20-0527.05
Expiration Date: 08/05/25
Approval Date: 08/06/20
Page 1 of 8
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
www.miamidade.gov/economy
Atlas Roofing Corporation
2000 Riveredge Parkway, Suite 800
Atlanta, GA. 30328
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In
Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Pinnacle® Pristine, StormMaster® Shake and ProLam™ Architectural Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 17-0706.07 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino
NOA No.: 20-0527.05
Expiration Date: 08/05/25
Approval Date: 08/06/20
Page 2 of 8
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
1. SCOPE
This approves Pinnacle® Pristine, StormMaster® Shake and ProLam™ Architectural Shingles manufactured by
Atlas Roofing Corp., as described in Section 2 of this Notice of Acceptance, and designed to comply with the Florida
Building Code, High Velocity Hurricane Zone.
2. PRODUCT DESCRIPTION
Product Dimensions Test
Specifications
Product Description
Pinnacle® Pristine,
Manufacturing location #1, 2, 3, 4
14” x 39 3/8” TAS 110 A heavyweight, fiberglass reinforced,
laminated asphalt shingle.
Pinnacle® Pristine,
Manufacturing location #1, 2, 3, 4
14” x 42” TAS 110 A heavyweight, fiberglass reinforced,
laminated asphalt shingle.
StormMaster® Shake
Manufacturing location #2
14” x 39 3/8” TAS 110 A heavyweight, fiberglass reinforced,
laminated asphalt shingle.
StormMaster® Shake
Manufacturing location #2
14” x 42” TAS 110 A heavyweight, fiberglass reinforced,
laminated asphalt shingle.
ProLam™ Architectural
Manufacturing location #1, 3, 4
14” x 39 3/8” TAS 110 A heavyweight, fiberglass reinforced,
laminated asphalt shingle.
ProLam™ Architectural
Manufacturing location #1, 3, 4
14” x 42” TAS 110 A heavyweight, fiberglass reinforced,
laminated asphalt shingle.
2.1. MANUFACTURING LOCATIONS
1. Hampton, GA
2. Dangerfield, TX
3. Meridian, MS
4. Franklin, OH
NOA No.: 20-0527.05
Expiration Date: 08/05/25
Approval Date: 08/06/20
Page 3 of 8
3. EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
PRI Construction Materials Technologies
TAS 107 ATL-054-02-01 05/04/10
TAS 100 ATL-053-02-01 05/04/10
TAS 100 ATL-119-02-01 07/22/13
TAS 107 ATL-133-02-01 09/26/13
ASTM D 3462 ATL-136-02-01 10/14/13
TAS 100 ATL-107-02-01 12/12/13
TAS 107 ATL-143-02-01 11/01/13
ASTM D 3462 ATL-118-02-01 06/26/13
TAS 107 ATL-106-02-01 09/05/14
ASTM D 3462 ATL-104-02-01 04/21/13
ASTM D 3462 ATL-135-02-01 10/14/13
ASTM D 3462 ATL-116-02-01 06/26/13
TAS 107 ATL-132-02-01 09/26/13
TAS 100 ATL-125-02-01 07/22/13
TAS 107 ATL-144-02-01 11/01/13
ASTM D 3462 ATL-220-02-01 10/12/17
TAS 100 ATL-220-02-02.1 10/12/17
TAS 107 ATL-220-02-03 10/12/17
ASTM D 3462 ATL-221-02-01 10/12/17
TAS 100 ATL-221-02-02.1 10/12/17
TAS 107 ATL-221-02-03 10/12/17
ASTM D 3462 ATL-222-02-01 10/12/17
TAS 100 ATL-222-02-02 10/12/17
TAS 107 ATL-222-02-03 10/12/17
ASTM D 3462 ATL-223-02-01 10/12/17
TAS 100 ATL-223-02-02.1 10/12/17
TAS 107 ATL-223-02-03 10/12/17
ASTM D 3462 ATL-224-02-01 10/12/17
Underwriters Laboratories, Inc. UL 790 11CA51478 02/01/12
NOA No.: 20-0527.05
Expiration Date: 08/05/25
Approval Date: 08/06/20
Page 4 of 8
4. LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
5. INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail ‘A’, attached.
5. 42-inch Pinnacle™ Pristine 6-inch offset layout shall be in compliance with Detail ‘B’, attached.
6. 42-inch ProLam™ Architectural 6-inch offset layout shall be in compliance with Detail ‘C’, attached.
7. Pinnacle Pristine™ Laminate sealant pattern shall be in compliance with Detail ‘E’, attached.
8. ProLam 42 Laminate sealant pattern shall be in compliance with Detail ‘D’, attached.
9. Nailing shall be in compliance with Detail 'F' and Detail ‘G’, attached.
6. LABELING
Shingles shall be permanently labeled with the manufacturer’s name and/or logo, city and state of manufacturing
facility, and the following statement: “Miami-Dade County Product Control Approved” or with the Miami-Dade
County Product Control Seal as seen below:
7. BUILDING PERMIT REQUIREMENTS
Application for a building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or the applicable code in order to properly evaluate the
installation of this system.
NOA No.: 20-0527.05
Expiration Date: 08/05/25
Approval Date: 08/06/20
Page 5 of 8
PINNACLE® PRISTINE,
STORMMASTER® AND PROLAM™ ARCHITECTURAL
DETAIL ‘A’
TRIM 5"
SECOND COURSE
TRIM 10"
THIRD COURSE
FULL SHINGLE
FOURTH COURSE
FIRST COURSE
FULL SHINGLE
NOA No.: 20-0527.05
Expiration Date: 08/05/25
Approval Date: 08/06/20
Page 6 of 8
DETAIL ‘B’
42” PINNACLE PRISTINE™ 6” OFFSET
DETAIL ‘C’
NOA No.: 20-0527.05
Expiration Date: 08/05/25
Approval Date: 08/06/20
Page 7 of 8
42” PROLAM™ ARCHITECTURAL 6” OFFSET
DETAIL ‘D’
PINNACLE™ PRISTINE 42” LAMINATE SEALANT PATTERN
DETAIL ‘E’
NOA No.: 20-0527.05
Expiration Date: 08/05/25
Approval Date: 08/06/20
Page 8 of 8
PROLAM ARCHITECTURAL™ 42” LAMINATE SEALANT PATTERN
DETAIL ‘F’
DETAIL ‘G’
END OF THIS ACCEPTANCE
39 3/8”
14”
7 ½” 1”
6”
1”
APPROVED FASTENER
6 7/8”
7 ½”
42”
1”
APPROVED FASTENER
1”
6”
14”
6 7/8”