Loading...
HomeMy WebLinkAboutCentral Air SystemPage 1 Residential Heat Loss and Heat Gain Calculation 6/16/2015 In accordance with ACCA Manual J Report Prepared By: ?m , 0 -Y Central Air Systems Inc, For: Klimdvich 10725 S ocean blv FT.pierce,ll Design Conditions: Fort Pierce Indoor: Outdoor: Summer temperature: 70 Summer temperature: 90 Winter temperature: 70 Winter temperature: 42 Relative humidity: 55 Summer grains of moisture: 127 Daily temperature rangeNledium Building Component Senslble Laterrt Total Total Gain Gain Heat Gain Heat Loss (BTUH) (13TUH) (BTUH) (BTUH) Duct 2,627 0 2,627 2.091 Floors 1,080 0 1,060 1,908 Wells 1,832 0 1,832 2,172 Ceilings 2,239 0 2,239 1,425 People 1,500 1,150 2,660 0 Fireplaces 0 0 0 0 Misc 1,200 0 1,200 0 Windows 7,621 ,..0 7,621 3,411 Doom 621 621 737 Glassdcors ..,.,F.` 0 0 0 Skylights ` 0 0 0 Infiltration 1,408 L 11 2,9 4,324 4,258 Whole House 20,128 a,, ,F , 24,11t4 16,002 ?e ��e G° (2 ions ) 7 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load cewLwons are ewn,elea oil% amm bads eney v=y due,owsW*f end ca+Wumn &?aenoos. E'd S2096E.:i9S zaijatgns u 1 WdZZ=i Sloa 91 unr