Loading...
HomeMy WebLinkAboutSet-Up Manual AddendumSET-UP MANUAL ADDENDUM �N\ JA;OBSEN HOMES' 600 PACKARD COURT SAFETY HARBOR, FLORIDA (727) 726-1138 NOTICE These specifications and drawings are original, proprietary, and confidential materials of Jacobsen Manufacturing, Inc. Such materials are provided to the recipient for specific. purposes and must be kept confidential and secret from others. REV 01/10 ALL HOMES'SET IN FLORIDA MUST COMPLY WITH DMV RULE 15C EFFECTIVE MARCH 29,1999 For information on 15C contact the Department of Motor Vehicles 850-413-7600 1 NOTES: ADDENDUM EXTERIOR HEATING/COOLING DUCT DUE TO THE NEW THERMAL REQUIREMENTS INSTITUTED BY HUD, THE INSULATION VALUES OF THE MANUFACTURED HOME HAVE INCREASED. IT IS NOW NECESSARY FOR ALL EXTERIOR DUCTS INSTALLED ON JACOBSEN HOMES HAVE A MINIMUM R—VALUE OF B. ALL HEATING AND/OR COOLING SUPPLY AND RETURN DUCTS EXPOSED DIRECTLY TO THE OUTSIDE AIR, SUCH AS UNDER CHASSIS CROSSOVER DUCTS OR DUCTS CONNECTING EXTERNAL HEATING, COOLING OR COMBINATION HEATING/COOLING APPLIANCES SHALL BE INSULATED WITH MATERIAL HAVING A MINIMUM THERMAL RESITANCE OF R=8.0, WITH A CONTINUOUS VAPOR BARRIER HAVING A PERM RATING OF NOT MORE THAN 1 PERM. WHERE EXPOSED UNDERNEATH THE MANUFACTURED HOME, THE DUCT SHALL NOT BE IN CONTACT WITH THE GROUND, / DUCT SUPPLY OR RETURN DOLING SSOVER USE MINIMAL AMOUNT OF DUCT. LIMIT DUCT USAGE TO REDUCE THE AMOUT OF BTU/HOUR LOSS. DO NOT OVER BEND OR CRIMP FLEX DUCT, THIS WILL RESTRICT THE AMOUNT OF AIR FLOW THROUGH THE DUCT. USE STRAPPING OR OTHER MEANS OF SUPPORT TO PREVENT THE DUCT FROM COMING IN CONTACT WITH THE GROUND. PLACE STRAPS AS NEEDED TO SUPPORT DUCT (DO NOT RESTICT AIR FLOW BY OVER TIGHTENING SUPPORT STRAPS). ALSO SEE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR DUCT INSTALLATION AND SUPPORT. 00ARAPROVAL•VED BY " 1 5 1995INC pyARi9rOMC� JACOBSEN HOMES NOTICE DRANK BY: DATE: REV. LETTER THESE sKancAmffs AND DRAW NGS ARE C.L.Y. 5-30-95 MONAL PROPRIETARY. AND CCN11pf1i11A1 DRAINING TITLE: YATERUILS OF JACOBSEN MANUFACTURING P.O. BOX 368XTERIOR A/C DUCT INC.HSUai YATERALS ARE PRONGED i0 THE SAFETY HARBOR. FLORIDA 34695 REOPI NT ►OA SPECnC PUAP= Alp WST BE DRAINING NUUBER: PHONE (813) 726-1138 IVT tOrmtBAE PC SECO n= DTtm AD—AC-0001 ADDENDUM WHOLE HOUSE VENTILATION SYSTEM YOUR HOME HAS BEEN EQUIPPED WITH A 'WHOLE HOUSE' VENTILATION SYSTEM. THIS SYSTEM HAS BEEN DESIGNED TO MEET ALL THE REQUIREMENTS SET FORTH BY THE UNITED.STATES DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT. THE WHOLE HOUSE VENTILATION SYSTEM IS REQUIRED (BY HUD) TO EXCHANGE AIR DIRECTLY WITH THE EXTERIOR OF THE HOME. THE PURPOSE OF THIS SYSTEM IS TO GIVE THE HOME OWNER THE ABILITY TO INTRODUCE FRESH OUTSIDE AIR INTO THE INTERIOR OF THE MANUFACTURED HOME, INSTEAD OF SIMPLY RE- CIRCULATING THE SAME OLD, STALE AIR THROUGHOUT THE HOME, THUS IMPROVING THE INDOOR AIR QUALITY. THE SYSTEM INSTALLED IN YOUR HOME HAS BEEN DESIGNED TO GIVE YOU COMPLETE CONTROL OF WHEN AND HOW THIS SYSTEM IS USED. YOUR HOME IS EQUIPPED WITH A FAN THAT WILL EXHAUST STALE INDOOR AIR (TO THE EXTERIOR OF THE HOME). THIS FAN IS SWITCH CONTROLLED AND MAY BE MANUALLY OPERATED. TO DIsCCNTI'NUE USE OF THIS SYSTEM, SIMPLY 'TURN OFF' THE SWITCH THAT CONTROLS THE FAN. NOTICE TO HOMEOWNER Whole house ventilation switch You will be able to locate the switch that controls this fan by locating the switch that is labeled -WHOLE HOUSE VENTILATION. (See AD-AC-0100) APPROVED BY IN 14 sit " INC. PeaonrA�v+c�uow� IAIOFiYQ1iiMOMCi DRA-Nm JACOBSEN HOMES NOTICE: DRAWN BY: DALE: rtV.ltlRrr THESE snonCARONs AND ARE C.L.Y. 9-23-95 ammAL PROPKTARY.-AND OmrU rAL DRAVANG TITLE: W.H. VENT. $Y$. B P.O. BOX 368 MATERIALS OF JACOBIN MANUFACMUC „ INC. M NAIEPJALS ARE PROVXG 10 79 SAFETY HARBOR. FLORIDA 34695 RECM1 FQ! VCCFIC PINPOIS AND UZI r ORAMNG NUMBER: PHONE (013) 726-1138 IQP1 oOKnC m AID SEWET FROM OT106 AD—AC-0100 3 ..r ...... v Tv W.W. mru%. .71 nwll\V1-1 - - WITH FASTENING INTO JOIST i EACH SIDE OF CENTER LINE PER TABLE BELOW: FOR GAPS IN FLOOR SYSTEMS INSTALL WOOD SHIM AT ALL LAG TO 1/f, INCREASE LAG LENGTH 1' NDS01 LOCA71ONS FOR LAG SCREW TO GO AND FOR GAPS TO 3/4'. INCREASE THROUGH AND TO KEEP CONNECTION (ALL ZONES) LAG LENGTH 1 1/2'. TIGHT. (SEE NOTE 2) (ALL DFOWRES) We =K OSL DD':IE 3/6' X ] 1/7 LAG SCTiM 30 G STRAP FASXN D M/ 7 6' X 16 CA STAPLES 16ND ZONE EXPOSLDLE WWM NLbIMR Ci FASTENERS REWIU 0.131' X 1 1/Y NMLS 7/16' X 16 GA. STAPM MUM SPAC M' MAX66XI SPACM IV O.C. 2 1/4' CLC. 3 5 2 2 b' 1T' or. 1 7/;r O.C. b' 4 7 1Mr aC. 2' aC 'C 4 7 � 3 b' 16' aC. 1 1/2' aC. b' 5NOTESe e ENGNEFR APPROVAL DAM APPROVAL: APPROVED BY 1. 1' MN, PENMAI N 6 REQll O ON STAPLES FOR MN. a016' STRAP. L WOOD SM6 70 BE RIPPED FROM SPF /3 MN. OR KM (r X 4' X GAP 6DIH MR 9� Revised ay 24 , 2006 P1,11NIC. r �.,0,46� OSBOR PLrfmMAYBE USED F >flL"m EQUALS GAP MDTH-4'X4'OL30John& DOE on, p I+. 1KP Engfmr!ng, '!C FEDWAL MANUFACTURED HOME CONSTRUCTION AND SAIETY STANDARDS 4. SEE 0 DE AU MRSFJ W FLOORS FOR NR NFLWAWL JACOBSEN HOMES r" FfaWAIt A6 dUW= AK DUN BY. M.T. DAME 05-22-06 Lam►. `E„E>z P.P.O. eox ]ce a NW4. PMMUMY, AM mMloWK MATU AW �AOO UN"A U M M C1l 00 W- „XE„ MAXXU A„ E � TO 1Nr DRA1LEdC nNLL M FLOOR FASTENING SAFETf HARBOR, FLORIDA 3095 MsCFW fm FUW MS $ 0 OW M DRAW4 NU1BM Ll PHONE (813) 726-1138 ml WEICIM& No um "A OR= I AD—FA-0001 ADDENDUM MULTI -WIDE UNIT WALL FASTENING ENDWALL NDS01 NOTESe 1. FASTENING REQUIRED ONLY AT MARRIAGE LINE OF EXTERIOR WALLS. .131- X 3 1/2- MIN. NAILS Ir O.C. MAX. SPACING, STAGGERED FROM SIDE TO SIDE (TOE —NAILED). MARRIAGE LINE -7� s zj a& John C. Weden, Rf`. 1C2 En_v+rreering. !tto APPROVED BY NRevised May 24,2006 rl INC. ceoeaK wrroc�to �e co�mirocraN No zunr sTrioum JACOBSEN HOMES >x WAVIN �' M.T. DA1E 05-22-06 Mid , P.O. Box 36a � mmum AK �.m~m.,M W�w~A W. „o, HAMM AT �„�„x MAW I� M/IN WALL FASTENING B SUM HARBOR, FLOMA 34695 NOW is 9= PAM= NO NO E ORAWC Mlilfif3t PHONE (613) 726—tt36 mn mom w No =a m amm AD—FA-0010 5 ADDENDUM MULTI —WIDE ROOF FASTENING CENTER LINE OR MATING ! LINE OF TRIPLE WOE UNITS 30 -GA. GALV. STEEL STRIP I SECURED WITH 7/16' X 16 GA. STAPLES FULL PENETRATION INTO DECKING (SEE CHART ON AD-FA-0001 MAX SPACING). .30 GA. GALV. STEEL STRIP -6' X LENGTH OF ROOF (SECTIONS MAY BE OVERLAPPED 2' MIN.) W/STAPLES AS SHOWN. INSTIL. ROOF CAP PER SET— UP MAW. OVER GAL STRIP. I (30 GA. GALV. STRIPS USED MAY BE 01 WIND DEFLECTORS REMOVED FROM -LAG SCREW SET BACK ROOF IN ORIGINAL CONDITION, FOR TRIPLE WIRES EXCEPT FOR STAPLE HOLES) FOR DOUBLE WIRES PLAN MEW 1 4' 2 3 4' 3/6' X 5' LAG SCREWS •kAG SCREW MI BACKS TRIPLE WIDE R i LINE — (2 1/4' SMOOTH SHANK) FOR DOUBLE WIRES INSTALL LAG SCREWS _— SEE CHART ON AD—FA-0001 .� FOR TRIPLE WIRES ATAA� I -- FOR MAXIMUM SPACING 21 4 234' 1 4' TO 3 4' GAP ROOF PERIMETER RAIL—y OR RIDGE BEAM (FOR RIDGE BEAMS SEE NOTE #4) CROSS—SECTION J �— INSTALL WOOD SHIM AT ALL LAG FOR GAPS IN ROOF SYSTEMS OR GAPS TO 3/4', INCREASE LOCATIONS FOR LAG SCREW TO GO ANDFFOR TO 1 INCREASE LAG LENGTH 1' THROB{ AND TO KEEP CONNECTION NDS01 LAGTK;:iT. G LENGTH 1 1/2'. (SEE NOTE 2)REF CAL.C. PG. ( A EXPO ZONES) CROSS—SEC110N(W/GAP) C WA- 91.01- 91.07 ALL NOTES: - - EHGRIEFA APPROVAL DAPIA APPROVAL L 2 1/!l' MOL PEHM110N INTO IECCM MOM IS Ream FCR LAG SCREIMS. 2. WOW SPW M K WM FRW SPF p UK OR KTTM APPROVED BY (rXCXWWQlHMIL ME) �1'0,6_ (058 OR PLYWOOD MAY K USED F MCXBESS EOUAS GAP WOTH4 X /' MX WLE) 3 SEE OTIER DETAIS FOR OOLFLEIING ROOF Revised ay 24,2006 IN7PIIINC. NWC70 4. NkEN N TMM A LAG SfJif1N KID A RIDGE BENL ffM-ML A 3/r aEMMCE John C. �oeen. RL HOLE TM011CA1 TIE FIRST FWGE WEAL. SEO D-M A 1/4' HOLE IMGH THE K2. EngW-*ern La, Inc FEDEML !MANUFACTURED HOME RECE1M FUDGE 1EM FOR TIE NEAOED POR71ON OF LAG 9' E ' DIESE DN& ARE CONSTRUCTION AND SAFETY STANDARDS FOR 3/V LM SMIEW QLT S LUa' MA7GWN SOML HOAR. EM JACOBSEN HOMES u— smN�� � mum= AM wAtiw B-t M.T. DA1Ee 05-22-06 P.OLUIIRMS Box aaa oTEOEM. pRopmam . MO oafTDOF x Or � W=SM YAMIFACTIRaEC bC � w,� ARE R�� m nc DRAWHG ItAk M/W ROOF FASTENING ARE 6� 7 Ftl � DRAIING KIMMt PSAMTMt10HF1E (ba1R3j 1136 a I n D o E AD-FA-0020 METAL ROOF RIDGE CAP DOUBLE WIDE UNITS ONLY PLAN VIEW 29 GA. MIN. GALV. STEEL RIDGE CAP COVERING LENGTH OF ROOF (MR ? OVERLAP AT SEA11) CENTER OR MATING LINE WITH P X 7/16• HEAD X Y FULLY THREADED SCREW AT EVERY RIB (AND ON BOTH SIDES OF RIB WITHIN END ZONE) SEALER STRIP BETWEEN RIBS OR CLOSURE STRIP RUNNING ENTIRE LENGTH OF ROOF II .I I I #8 X 7 16- HEAD X 2' j FULLY THREADED SCREW I (NO MORE THAN 12. O.C.) I .I II � I I •I a 1 w I 1 � 11 e m 1 � I � v 1 I , j I1 METAL ROOF PANELS STOP 1 APP. _Y FROM CENTER LINE I , Ref: EX-13-0051 and `-30 GA. GALV STEEL STIR AD-FA-0020 5' X LENGTH OF ROOF (SEE AD-FA-0020) SECURED WITH 7/16- X 16 GA. STAPLES NDS01 FULL PENETRATION INTO DECKING (ALL ZONES) (SEE CHART ON AD-FA-0001 MAX SPACING) (ALI ) JOTW: ENOW APPMAL• SEE OTHER DETAILS FOR CONNECTIONS BETWEEN SECTIONS STANDARD 7/160 O.S.B. (24/16 INDEX) ROOF SHEATHING. METAL PANELS ARE 29 GA. MIN. STEEL WITH 9' QC. RIBS V 7 SCREWS HAVE A NEOPRENE WASHER FOR WEATHER PROOFING AND 1C ,'roi,, F_. TO HELP AVOID OVER DRIVING. IF SCREW IS OVER DRIVEN laolghuxOng, Inlr ANOTHER SCREW MUST BE ADDED BESIDE THE INEFFECTIVE SCREW (DO NOT REMOVE OVER DRIVEN SCREWS) APPROVED BY NSep 10,2008 ri INC. FEDERAL YANUFACTUR ED HOME CONSTRUCTION AND SAFETY STANDARDS JACOBSEN HOMES PA BOX 368 SAFM HARBOR, FI.MA 3095 PmC (813) 725-1136 mm �► ME OWNAL Pam: AM menu MA19M W NAMSEN RWACMNG iImE1t��lM�RX===10 E wT mim L m =r fl= om �`"'" °" D.M.T. w'c 08-25-08 ' "arm MAW ME FETAL ROOF RIDGE CAP MAIY�C AD-FA-0021 ADDENDUM MULTI=WIDE ROOF SEALING/CLOSE-UP MIN. 30 GA. GALV. STEEL STRAPPING \ SEE AD-FA-0020) 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES 1. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). 15# FELT UNDERLAYMENT MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT RECOMMENDED EACH SIDE DAPIA APPROVAL• i•h J11-1 N� YY•�/K71/Im DOE aw,roswEnswaKy JACOBSEN HOMES xODRAMtI BY: OA1E: REV. LETiFR TFIESE SPEGi1G1IDHS AND AND DRAwNGS ARE C.L.Y. 6-5-95 [rocl 0MOMIAL PROPRIETARY. AND [LNt10 IK DRAWING TITLE: P.O. BOX 368 "A� OF NANIXACIMC M/W ROOF SEALING W- SUCH VAIEJEALS ARE PRONGED TO THE SAFETY HARBOR. FLORIDA 34695 REOW rOR SECEIt ""0 AND IAAT BE DRAWING NUYBDt PHONE (813) 726-1138 PVT CWIDDITK AM SEM ►T= DnoM AD—FA-0025 8 ADDENDUM MULTI -WIDE. ROOF SEALING/CLOSE-UP MIN. 30 GA. GALV. STEEL STRAPPING (SEE AD-FA-0020) 6" STRIP ROOFING CEMENT RECOMMENDED OVER EDGES - LOW SIDE NOTES: 1. 30 GA. GALV. STRIPS USED MAY BE HIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). 6" STRIP ROOFING CEMENT REQUIRED OVER EDGES - HIGH SIDE 15# FELT UNDERLAYMENT MULTI -WIDE ROOF LINE BEAD OF ROOFING CEMENT (2 BEADS REQ'D HIGH SIDE 1 BEAD RECOMMENDED ON THE LOW SIDE) BY JUN I 5 W5 I INC mw rfsLmwm NOTICE UNARM UT: MY. JACOBSEN HOMES THESE sPEaTlrwtwNs AND oRATYNGS ARE C.L.Y.. 6-5-95 MONAL. PROPRIETARY, AND 00WUNML DRAWING TITLE - MATERIALS OF JACOBr;EH MANUTAC11MIG M/W ROOF SEALING P.O. BOX 368 we 9" MATERIALS ARE PROM TO THE SAFETY HARBOR, FLORIDA 34695 RECPC NT FOR S WX RRIaM NO MIST BE DRAWING NUMBER PHONE (813) 726-1138 IQPT COWIDEHM AND SECRET TRW OTPUM AD—FA-0026 C i SHIPPED LOOSE HEARTH EXTENSIONS HEARTH. INSTAL LATInN- 1. REMOVE ANY CARPET AND/CR PAD FROM UNDER THE HEARTH EXTENSION AREA 2. INSPECT THE META FUl4flNG IN THE HEARTH AREA TO WE THAT IT HAS BEEN IWALLED (THIS RAS = MUST BE PLACED ON THE FLOOR TO PROTECT THE AREA BETWEEN THE FIREPLACE AND THE HEARTH). I LOCATE THE !EARTH EXTENSION (SHIPPED LOOSE IN THE HOME) AND INSTAL FOLLOWING THESE STEPS: A. CAREMLY PUCE THE HEARTH EXTENSION W THE PROPER LOUDON IN FRONT OF THE HIEPLACE ASSEMBLY. B. SECURE THE HEARTH EXTENSION TO THE FLOOR W/ 4 181 2' WOOD M MT C. FTLI. THE AREA BETWEEN THE FACE OF THE FIREPLACE AND THE HEARTH EX09ON WITH A NON-COMBUSTABLE CAULKING OR MORTAR. D. OR FOLLOW THE HEARTH MANUFACTURERS INSTRUCTIONS FOR INSTALLATION. TILE SURROUND TYP. HEARTH (MAY BE SHIPPED LOOSE) NOTES; 1. A TYPICAL ILE FRONT FIREPLACE IS SHOWN, HOWEVER THIS DETAIL APPLIES TO ALL FACTORY INSTALLED FIREPLACES. (STONE, WOOD, GYPSUM, TILE, STUCCO, ETC... MAY BE USED IN LIEU OF THE TYPE OF FIREPLACE SURROUND SHOWN ABOVE.) JACOBSEN HOMES NOmc� THESE sPEarlunaNs AHD oRA.,a AM OraGNAL. PROPRIETARY. AND CMI'MAk P.O. BOX 368 IIATUdALS OF JACOMN MANUFACAWG „ THE SAFETY HARBOR. FLORIDA 34695 ply rat 9 AM PRD AND H 19E PHONE (813) 726-1138 PuT cam la NO SEORET 1RW GUM TYPICAL WALL WOOD TRIM FACTORY INSTALLED FLASHING APPROVED BY .JLN 2 8 19% INCON 14 R9(ftW"ACrOWNM =r6Tftvamc=vmnvQ4= BY, DAIS REV. LETTER C.L.Y. 6-16-95 I ­_ SHIP —LOOSE HEARTH DRAWING HUMBER AD—FP-0001 10 SMOKE ALARM ADDENDUM Enclosed in the home owner's packet is the smoke alarm user's manual, (if it is not there, contact Jacobsen Homes and one will be sent to you. NOTICE TO DEALER AND SET-UP PERSONNEL This home is equipped with a smoke alarm system and must be tested in accordance with the smoke alarm user's manual after the home is completely set-up and all the electrical connections are done. NOTICE TO CUSTOMER Smoke Alarms have been installed in your Jacobsen Homes. You should be familiar with the locations and operation, and learn how the alarms can be silenced once they have sounded and be familiar with its use. This is a very important safety device installed for your protection. Be sure that it is kept in A-1 working condition by testing if frequently in accordance with the manufacturer's instructions. The alarms operate on household current, and have battery backups. Its purpose is to provide early warning in case of a fire. Again we stress the importance of keeping your smoke alarms in proper working order. TESTING SMOKE ALARM Test smoke alarms after home has been set-up completely. To test the smoke alarm, press and hold the test button on the cover of the unit, until the alarm sounds. All smoke alarms should sound alarms. If all units do not alarm, replace units immediately. This test should be given to all smoke alarms individually. APPROVED BY QEV 001orON 9W 25 20 INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDAHUS SET-UP MANUAL ADDENDUM AD-FS-0001-A 11 TRUSS SHEATHING APPROVED EY INPIINC. FOULMANUMMIRE (HOME CONSiRUW =ANDSAFETYSTABWROS DEALER (SET-UP)INSTALLED PLYWOOD FOR SHEATHED TRUSSES HINGED TRUSS - NOTE: HOLES TO BE CUT IN SHEATHING TO ALLOW OUTLOOKERS TO PASS THROUGH, TYP. OUTLOOKERS FACTORY INSTALLED PLYWOOD FOR SHEATHED TRUSSES L SIDEWALL 3/8" MIN. APA OR TECO RATED SHEATHING APPLIED TO ROOF TRUSSES LOCATED DIRECTLY ABOVE SHEARWALLS (APPLICABLE TO ALL SHEARWALLS) PENETRATIONS OF THE SHEATHING ON THE TRUSS(ES) FOR i!'.E OVERHANG OUTLOOKERS (PURUNS), ATTIC VENTALAIION. OPENINGS IN TRUSS SHEATHING MAY SE LOCATED AT ANY LOCATION ALONG THE LENGTH OF THE TRUSS. (18' X 14 1/2' MAXIMUM SINGLE OPENING SIZE IN TRUSS SHEATHING) NOTES: 1. 3/8' MIN. RATED SHEATHING FASTENED TO ROOF TRUSS WITH 7/16' X 1 1/2- X 16 CA. MIN. STAPLES 1 1/4' O.C. AT PANEL EDGES AND 3- D.C. AT ALL FRAMING UEMBERS. (NO GLUE RE(XJIRED) MARRIAGE WALL \ \ \ \\ \ \ \\ \ \ 3/8' SHEATHING TO BE INSTALLED ON -SITE K2 APPROVAL: 1MINOZONE III (110 MPH) ALL EXPOSURES APPROVAL APPROVED BY MAY E IN INC. FEDERAL MANUFACTURED HOME =TRUCTION AND SAFEN STANDARDS NOTICE: UNAWN 1IT: VAIC REV. LETIER: JACOBSEN HOMES THESE SPECNICATIONS AND DRAWINGS ARE R.R. 4-27-98 ■ ORIGINAL PROPRIETARY, AND C ro""RAL ORAWINGG TITLE: P.O. BOX 368 MATERIALS OF JACOBSEIN MANUFACTLIRINC TRUSS SHEATHING _ INC. 91CN MATERIALS ARE PRONGED TO 1NC SAFETY HAR80R, FLORIDA 34695 REFAU T FOR 9IF= RWOSES AND MST BE ORAWINC NUMBER: PHONE (813) 726-1138 XEPT CONnUNIIAL AND SE1R1.1 rROM OTHERS. AD-HR-0001 12 HINGED ROOF DETAIL dSTAlKi of 1RAla m RAIg RoaF laa+ sF m pmml m xr-W mu, Is APPROx n 1/r. uFt Ian. RooF smu SGUA1aY n1 IIE VWA ot= RO IIOI6111A11 U NXr APARL• .UUX UFTNO WM Poll x, W cc OF ROOF =w m0 AM UFINC WW' . 2 FiI:T F A :PULE N K RAI RAL HINGED ROOF IN SHIPPING POSITION HINGED ROOF IN SET—UP POSITION NDSOI NOTES: I. WAM RAM ROOF' SEM N X RAM POMM MORE SMWW Mn me Pam mm PO9mL ma arc rm 10 ma ow 6 SPr /! FOB I= POST 10P RAL -11o:r.000mouts-wir ERc'R REF. CALL. PG. C-RF- 223.0 - 223.6 John C. Doeden, P.L. -<2 Enq-ffm*rw q, Inc APPROVED BY 1110000. Revised JUn06,2006 .N1 INC. CMTIWC" AND SKFTr WPXDAM ndmincmcm JACOBSEN HOMES ��•` �»W+ME ramimu RY. m.cummunm wTaA�s ar wxirAcnwie MAINI or�� o.A. os—o2—as Mug 11D HINGED ROOF DETAIL P.a eox 3E0 IIG so YA1um ARi mR A m GRAV 16 MAA M SAFETY MARSM FLOFMA 34695 IasDrt IER SIM PNW b0 LUf K- PHONE (W) 726-1138 WT COFUN L w =a m ON= AD—HR-0002 13 HINGED ROOF DETAIL UHDERLAYMENT TO BE GWED r MIN. ON BOTH SECTIONS OF HRiGE ROOF. FOR WIND ZONES 2 AND 3. RAISE EXTENDED SHINGLE AND UNDERlAYMENT AND - AND A MIN. 4 1/r WIOTH OF ROOM CEMENT TO 70P OF LAST SHINGLE ROW ON FIXED ROOF SECTION, (THIS IS TD BE DONE BEFORE RAISING HINGED ROOF SECTION.) SHINGLE AND UNDERLAYMENT CEMENTING AT HINGED AREA ATTACH 2 X 6 X 6' BLOCK BEHIND 2 X 6 - OVERHANG FASMA BOARDS AND SECURE WITH 3-08 X r WOOD SCREWS EACH SIDE CF GAP. APPROVED BY Revised Nov o30,2006 rNC. FEDERAL M WFACTURED NDYE CDNSTRYCFIDN AND sAFEIt srM1011RDs BLOCK ATTACHMENT AT FRONT AND REAR OVERHANGS 1INDZONE IA (110 11PH) ALL EXPOSURES NOTES: ENG W APPROVAL: DAPIA APPROVAL: 1. ORMI kWD ROff SECIXTN IN THE RAISED P09TION T#FW SWUNG YM KING POSTS 010 PQ9110N. John C. DmdM PAW. K2 EnpMWO Ur, JACOBSEN HOMES mv. wa Am WA� AK A" B1 D.T. 0A1E 10-02-06 lay► CRC. PMFJCIW. AM a�mx DRAWA TI7W UNWACIMC. P.4 BOX 368 MAMIMm 9m "Iowa Or w r�olm m w HIN R DETAIL SAFETY HAR60R. FLORDA Iasi wwm ro SR!m RWM Ao ow K DRANNG MWR: m ow WA Y AD—HR-0003 PHONE 726-1138 an CO wmL AY woo 14 SHINGLE AND UNDERLAYMENT APFLICATION ON HINGED SECTION INSTALL ON SITE 15# FELT WITH A 6- MIN. OVERLAP ONTO MAIN ROOF CEMENTED WITH ROOF TAR AND SECURED PER NOTE #2 CONTINUE 15# FELT TO ROOF PEAK -1 UNE-PIECE SHINGLE DERLAYMENT ' 2� MIN. OVERLAP (IYP.) - c r---1 r—T n I~ ........... 7 &' MIN. TAR AS SHOWN N o .(APPLIED ON SITE) ~w I v� SEE NOTE #3:• ... .......... rMR ..... .. I I I � I � I� I I•.• I� � SEE DETAIL 19 r— itc ... a I / I t I I ' I t I r I t i � ' �s �.','• r--j SECURE FIRST ROW OF MINGLE TO BE INSTALLED ON SITE WITH • 6 STAPLES (1' X 3/4' X. 16 GA OR ROOFING NAILS) PER SHINGLE MANUFACTURER'S INSTRUCTIONS AND CONTINUE TO PEAK. _ REMOVE THE wit - GAP PIECE SHINGLE UNDERLAYMENT IN THE (HINGE SECTION IN DOWN POSITION) BEFORE LIFTING THE HINGED SECTION OF THE ROOF TO ITS FINAL POSITION AND BEFORE INSTAWNG THE 15# FELT AND SHINGLES. DETAIL A NOTES: 1. CEMENTING OF 15j FELT IS NOT REQUIRED IN ANY AREA EXCEPT WHERE NOTED. 2 FASTENING OF 15t FELT IS NOT REQUIRED. (FASTENERS APPLIED JUST TO HOLD FELT IN PLACE UNTIL SHINGLES ARE INSTALLED.) - 0 3. EXTEND THff . FIRST LAYER OF ON SITE 15/ FELT ONTO THE FIXED ROOF A MR OF 6- AND UNDER THE LAST COURSE OF FACTORY INSTALLED SHINGLES F NEEDED TO MAINTAIN THE 6- WN. OVERLAP ONTO THE FIXED ROOF. 4. INCLUDED IN THE HINGED ROOF ADDENDUM ARE DETAILS AD—HR-0001 (WITH SPECIFIC END PANEL LAYOUT), AD—HR-000Z AD—HR-0003. AND AD-0 R-0004. WINDZONE III (110 MPH) ALL EXPOSUREf OPROVED BY MANUFACTURED HOh1E ,r'TVW AND SAFETY STANDARUS NOTICI& Lom"m at; .....� ...�.... JACOBSEN HOMES THE TIC A„D mwm M.T. s-2o-o3 O WW L PMPWMrf. AND =#MU MI DRANING TTRE SHINGLE AND U DERLAYMT _ MAIERAS of ACMW UNWACTURM APPLICATION ON HINGED SECTION P.O. BOX 3w HG SLXN HARWA S ARE PROD TO 1E SAFETY HARBOR. FLORIDA 34695 RECFFM FOR 9-EM ND KW IE DRAWING NUMBER: PHONE (813) 726-1138 WT ot1ti10FNlK on mu Rm o m AD—HR-0005 15 PEAK INSTALLATION DETAILS SECURE ROOF PEAK ASSEMBLIES TO - HINGED RAFTER WITH #8 X 4' SCREWS, 6-1/2' O.C. MAX DECKING ON RIDGE BLOCK ASSEMBLIES FASTENED WITH (6) 71/16' X 1 1/2' X 16 GA. STAPLES INTO EACH 15' O.C. RAFTER 'AND 3 1/2' O.C. MAX. INTO 2 X 4 RAIL (TYPICAL BOTH SIDES) I NDSOt NOTES: I. SEE AD—HR-0007 FOR INSTALLA71ON OF UNDERLAYIIENT AND SWNGLES. SEE AD-HR-0002 FOR ASSEMBLY DETAILS. - CRC - 167.01 - 167.02 APPROVAL I DAPIA APPROVAL - - 4 4 to `-- John 0. uoradwi, F.E. -92 EA"ring, Ir1c ALL VANDZONES ALL EXPOSURES 20 PSF ROOF 10 PSF D.L APPROVED BY INRevised J= 09,2006 INC. FEDEML MAAC7UIIE0 NOIRE collsTa IIUFIan- AIn suETr nAlloAaos JACOBSEN HOMES Non= TWSE z ICMAMS AND MATOKS ARE CRONAL. P11CFRQIART. AND CWMIUL UIIAWI UT: O.A. VAIt 06-06-06 IILI {LIMA: DRAWING 1IRL P.O. Box 366 LN MAT RMS aCT� AM MAIRIFALTR NO w- Sm MATERU ATM PT,DVIDO WTI[ PEAK INSTALLATION DETAILS SAiETY HARBOR,, FLORIDA 34695 PHONE (727) 726-1138 RTCPDII I0l 9EWC fUrO fS AND MAT EE Ivr cwn[xDAI AND W130 FIRM aROK DRAVMG NU16ER: . AD-HR-0006 16 SHINGLE/UNDERLAYMENT INSTALLATION SITE INSTALLED SHINGLES (USING THE TOP COURSE(S) OF SHINGLES TO 6 FASTENER METHOD) AND CAP INSTALLED OVERLAP PEAK AS SHOWN. PER MANUFACTURERS INSTALLATION INSTRUCTIONS. � , Re �4"—vk �2--d - ��R�bffi' w —� � SHINGLE INSTALLATION INSTALL FIRST LAYER OF 151 FELT TO ROOF NTH A 6' MIN. WIDTH OF ROOF CEMENT AT EACH ENO TO ROOF DEC( AND/OR EbSTWG FELT AS SHOWN. SEE OTHER DETAILS FOR SITE INSTALLED ROOF PEAK UNDERLAYMENT INSTALLATION . i NOTES: INSTALL TOP LAYER OF 151 FELT TO ROOF NTH A 6' MIN. WIDTH OF ROOF CEMENT AT EACH END TO ROOF DECK AND/Ott E)OSTWG FELT AS SHOWN. �BY AUG 0 # 20[► INC. NOTICE unnm r. o JACOBSEN HOMES MES, OFIMMS OT�-�� M.T. 7-2s—oa MMAL. FR�I iAkT. AID COfx1E11 DRAWKG TITLE. P.O. BOX 368 imp P.O. OF .IACOBSEN MMWACUM C SNNGLE/UNDERLAYMENT INSTALLATION — w- m MAmmS ARE FROOM TO 1NE SAFETY HARBOR, FLORIDA 34695 RiCt°EII1 FCR 7E1111C AfaoM NO EM S ORAFRNG NUMBER: PHONE (727) 726-1138 ReT Ca WAX no JW FROM 00M AD-HR-0007 1 ADDENDUM TYP. SHIP -LOOSE PLUMBING SUPPORT FASTEN 10 FLOOR FRAMING MEMBER W/ STAPLE OR NAL BANDING STRAP 'WRAPPED' AROUND PIPE AND FASTENED TO FLOOR FRAMING. ABE OF NOT LESS THAN 1/4' PER FOOT MUST BE MANTAKD TOWARD THE I OUTLET. WARE THIS GRADE CAN NOT BE ACHIEVED, NOT LESS THAN 1/8' DOT MAY BE USED WHEN A FULL SIZE CLEANOUT IS INSTALLED AT THE UPPER END. .. J VIEW OF DRAIN PIMP 1. PIPE CLEANER AND GLUE SHALL ALSO BE SUPPLIED BY THE MANUFACTURER FOR PLUMBING CONNECTIONS. 2. 48" O.C. MAX. SUPPORT SPACING. M AMROVALo •.11;� L JACOBSEN HOMES icsESP£CFrAV0oY9tcpMDjPROM nAM. ��er: RR "' 7-17-97 KY. Ler�R: LAWN. PRMIA"."CoM— DRAMIG TITLE: PLUMB YAIZMENS OF AO SM YAMIVACIUWMG 4 ,� P.O. eex 36e rc sm VAm4xs Am Wo►Cm To DIEING SUPPORT SMM HARBOR. RORIDA 34695 Itema wa srm� rwm No om K DRAF/NG MMER: PHONE (813) 725-113a an CMffMM t " sao rWd GUM AD—PL-0001 18 I NOTES: OPEN PORCH RAILINGS) IT IS THE RESPONSIBILITY OF THE SET-UP CONTRACTOR OR GENERAL CONTRACTOR ON SITE TO INSURE THAT THE RAILING(S) INSTALLED OR TO BE INSTALLED MEET ALL CODES IN EFFECT AT TIME OF HOME INSTALLATION. ROVED BY MAE V A INC. JACOBSEN HOMES NOTICE: DRAWN BY: DATE REV. LtI1tK: THESE SPECIFTCAlIONS AND DRAWINGS ARE M.T. 3-30-05 ORIGINAL. PROPRIETARY, AND CONKDENTIAL DRAWING TITLE: P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTMG OPEN PORCH RAILING S MG SUCH MATERIALS ARE FRONDED TO THE SAFETY HARBOR. FLORIDA 34695 REMPIM FOR SPECIRC PIINPOSES RD MT BE DRAWING NUMBER: AD-PO-0001 PHONE (727) 726-1138 KEPT COYfKI TK AND SEW FROM oKK 19 ON SITE PITCHED ROOF DETAILS IMPORTANT NOTICE THE ON SITE PITCHED ROOF INSTALLATION (INCLUDING SHINGLES AND CAP) MUST BE COMPLETED WITHIN 60 DAYS OF DELIVERY TO THE HOME SITE. FOR ATTACHMENT OF ALL VENTING (INCLUDES 12 EXHAUST & ROOF), SOLAR TUBES AND PLUMBING 41 VENTS SEE AD-PR-7007 & 7009. MAX. ROOF SLOPE - FOR ROOF DECKING DETAILS SEE AD-PR-7004. FOR ATTACHMENT OF PITCHED RAFTER TO TRIPLE WIDE SEE ` ` FOR ROOFING DETAILS SEE AD-PR-7002 SEE AD-PR-7008 �� ��` SHIP THIS SEC. LOOSE (SITE INSTALLED) >�— — — — — — — — — — — — — ------ FOR OVERHANGS c SEE AD-PR-7003. FACTORY INSTALLED RAFTERS (CENTER SECTION) REMOVE ALL FACTORY INSTALLED FOR ROOF VENTING BOTH FACTORY J POLYVINYL BEFORE INSTALLING THE AND ON SITE SEE AD-PR-7005 & 7006 ON SITE PITCHED ROOF RAFTERS CENTER SECTION OF TRIPLE WIDE TYPI AL TRIPLE WIDE HOME REF. PG. IW-07-0011 WITI- SITE INSTALLED PITCHED FOR FASTENING C ATER SECTION RAFTERS DAM APPROVAL' NOTES: APPROVED BY 00oARevised Oct 25,2007 INC. FEDERAL MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS NOTICE DRAWN BY: DATE: REV. LETTER: JACOBSEN HOMES THESEsPE(]FICAmsAND DRAWNMARE O.A. 10-24-07 , ORIGINAL. PROPRIETARY, AND CONFIDENTIAL DRAWING TITLE: min „ P.O. BOX 368 MATMALS OF JAtOMM VANUFACR"t; ON SITE PITCHED ROOF DETAILS INC, SUCH MATERALS ARE PRDWEO TO THE SAFETY HARBOR. FLORIDA 34695 RErpfFxT FOR W IWIC ROM AHD MIST BE DRAWING NUMBER: ® PHONE (727) 726-IIM IIEPT CDIaWTIAL AHD SEOV FRO OTHERS AD-PR-7001 20 ROOF- TO ROOF ATTACHMENT SITE INSTALLED 7/16- MIN. ROOF SECURE STE INSTALLED ROOF DECKING WITH 7/16- X 1 1/2- X 16 GA. STAPLES X 16 GA. STAPLES, 2' O.C. MAX. TO DECKING SECURED YNTH 7/16' X 1 1/2' A TA (12) EACH SIDE OF MARRIAGE LINE TO EACH RAFTER. EACH 16' O.C. RAFTER. • SEE DETAIL 'A' SEE NOTE 11 11' MIN. SITE INSTALLED DECKING OVERLAP SITE INSTALLED RAFTER TO FACTORY INSTALLED ROOF DECKING ALIGN WITH FACTORY INSTATED IL RAFTER BELOW- 8/ SEE NOTE 12 18' MIN. BE RIDGE BEAMS EE NOTE /4) kDECKING WA CROSS-SECTION REF. PG. RC-07-0044 FACTORY INSTALLED RAFTER (CENTER SEGRON) "N0ZOHE.11 All EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF D.L. NDS01 `C-FS3 - 88.01 NOTES: DKNW A"ROVAU DAM A"NOVA: 1. SECURE EACH 16" O.C. RAFTER TO RAIL BELOW VAlH 2-/10 X 4 f/Y SCREWS AT EACH RAFTER END. SITE APPROVED BY INSTALLED PITCHED RAFTER TO ALIGN WITH FACTORY INSTALLED RAFTER. (EA. SCREW TO HAVE 1 1/4' PENETRATION WIN.) oua o9,2006 2. ATTACH MATE LIE RAFTER RAILS (OR RIDGE BEAMS) WITH J #10 X 4 1/2' SCREWS 9- O.C. MAX SPACING: Vb Q�"tm4maINC. 1 SEE AD-FA-0020 FOR GAP TREATMENT BETWEEN SECTIONS JOr1T1 C. 08 nFruntF.au N K2 Engkmer ft, Inc. CONSMUMON AND S.FFN STANDARDS �/ JACOBSEN HOMES P.O. Box 360 SAFLTY HARBOR. FLORIDA 54695 PHONE (727) 726-1136 mamaarma, o oRAwmaAw eaowK, pwrmem". ro Do ormam W. MM UI M I MINI FM SAC WOO yp V= t UK eww"ft"wru Aft omL DRAWN er. 0 A " 06-02-064.001010 n /L.�l DRAMifi nnr: ROOF TO ROOF ATTACHMENT ORA1l� NCR: AD-PR-7002 21 RAFTER TOP CHORD END ZONE RAFTER/OVERHANG ASSEMBLY ALT. CONSTR. RAFTERS 2 X 6 OUTLOOKER 19' O.C. MAX. BETWEEN OUILOOKERS --,Z Q0, ".- -2 X 6 OVERHANG FASCIA THIS TRUSS INSTALLED ON SITE BOTTOM CHORD 160' DOUBLED END ZONE RAFTERS TYP. 16' O.C. 2 X 6 FASCIA FASTENED TO OUILOOKER W/14N. (5) 7/16' X 2 1/2' X 15 GA. STAPLES OR MIN. (3) .131' X- 3' NAILS (TYPICAL AT ALL CENTER BRACES) NDS01 19• oc ` 2 X 4 NAILING BLOCK (INSTALLED ON SITE) MIN. (3) .131" X 3' NAILS FROM NAILING BLOCK INTO RIM PLATE OF ADJACENT SECTION OF UNIT, AND . MIN. (3) .1310 X 3' NAILS FASTENING FASCIA INTO END OF NAILING BLOCK 2 X 6 OUILOOKER 19' O.C. MAX. BETWEEN OUTLOOKERS SEE CHART FOR FASTENING ALL OUTLOOKERS SHOWN ARE 2 x 6 SPF /3 FLAT f OUTLIER TO TOP CHORD MULTIPLE TRUSSES FASTENED TOGETHER W/MIN..131' X 3' NAILS OR MIN. 7/16' X 2 1/2' X 15 GA. STAPLES 16" O.C. MAMMUM INTO TOP do BOTTOM CHORDS ONLY. `- 2 X 6 OVERHANG FASCIA END ZONE ASSEMBLY NOTE: (SHIPPED ASSEMBLED FOR SITE INSTALLATION) OUROOKM M BE SMW w M IN THE EHDZONE PER FASTENER CHART. SINGLE TRUSS ONLY REO'D OU19DE OF 3 FT. AREA ...SS MAY BE PLACED ON EIIFIER SIDE 1. ALL TRUSSES LOCATED WITHIN 35" OF THE END OF THE R SECTION TO BE DOUBLED. 2. SEE OTHER DETAILS FOR TYPICAL ROOF FRAMING. 3. EACH TRUSS IN END ZONE AREAS ARE REQUIRED TO BE FASTENED PER AD-PR-7002. TYP. OUTLOOKER FASTENING: FASTENERS OUANTFIY PDMANt J31 PD NAB. 5 1 1/2' 15 GA. -STAPLE 8 1' I8 SCREW 2 1" (INCL 1�) OUILOOIO:R FASTENERS MAY BE NSTAM 1NINCIZONE 111 FROM TOP CHORD DOWN f POMATION ALL EXPOSURES 5 MANFANED. (110 MPH) 20 PSF ROOF 10 PSF D.L. C-RC-197.01-197.02 �Tleo9`> John C. Doom,'RL. 1(2 EngineG,.irig; lna• APPROVED BY NIPFeb 05,2008 INC. - FEDEPAL IUWUFACfURED NOYE CONSTANCIION AND SAFETY STANDANOS JACO BSEN HOMES NOTIC@ TIM SPE61F1OAIM AND OW NGS ARC DRICNIH. PROPRETMY. AND �i10QIIlAL I DRATM BY; O.A. DALE 1-29-08• REY. LETRR DRAWING IRE- P.O. BOX 368 MAIEI OF JIICO8501 YBAIFACWW W- so yA1uts" AM prom m" END ZONE RAFTER/OVERHANG ASSEMBLY A SAFETY sss HARBOR.�) WT MM no � DRAw+�c NUMasx OE 726ii38 AD-PR77003 22 ON SITE PITCHED ROOF DECKING INSTALLATION TYP. ROOF FRAMING 16' ON CENTER 16" MN. — TRIPLE WIDE CENTER SECTION PEAK \ SITE INSTALLED DECKING ON PIT08 NO BLO(�(ING REQUIRED TRUSS SECTION k REMAINDER OF AT CONTINUOUS PANEL BOTH OUTSIDE SECTIONS (2 FULL ROWS OF SHEATHNG) SEAMS BETWEEN TRUSSES SEE OTHER DETAILS TO SECURE TRIPLE WIDE MARRIAGE LINE SITE INSTALLED PITCHED TRUSSES MIN. WIDTH PER SHEATHING REQUIREMENT �MANIJF. INSTALLED DECKING TO HERE APA RATED ROOF DECKING (OR EQUAL) Is WINOZONE 11 ALL EXPOSURES (110 MPH) 20 PSF ROOF 10 PSF D.L. NOTE$: cm�cu :rr+sure� uwru�mw� 1. 1/e MAXIMUM GAP AND 1/16" MINIMUM GAP BETWEEN DECKING PERPENDICULAR AND PARALLEL TO TRUSSES APPROVED BY 2. ROOF DECKING MATERIAL TO BE 7/16- APA RATED ROOF (24/0 WTI air �:� Revised SPAN RATED) DECKING (EQUAL OR BETTER). John C. Do :.:�. � Oct 29,2007 3. OTHER TRIPLE WIDE SECTION (NOT SHOWN) WILL BE THE }C2�i1C��:«yilji;, `•14c N 14 INC. SAME DECKING PATTERN. FEDEW KANUFAMPED HOME 4. FASTEN DECKING TO ROOF FRAMING WITH 7/16 X 1 1 /2- X 15 CONSTRUCnON AND SUMSTANDARDS GA. STAPLES AT 3' O/C EDGES AND FIELD N0MM """"" O.A. JACOBSEN HOMES "' �.. �•,�,: nlESE sPEaFlGna�s ANo. DR�mres � 10-24-07 oa MN- F+ROPmumff. AM CQinaam. MANING TILE: P.O. 80X 389 VATO QS OF VZOM MAMFACUM sm Fum ms Am mwm m ra ON SITE PITCHED ROOF DECKING INST. SAFETY HARBOR. FLORIDA 34695 PZFW FDR US= F1L0M NO MbT BE DRAWNG NUFM PHONE (727) 726-1138 IVT CMEE K No Sm fmM an AD-PR-7004 23 SITE INSTALLED PITCHED ROOF VENTING TYP. 50 SO. IN. ROOF VENTS (SEE AD-PR-7006 FOR QUANTITIES) /SITE INSTALLED ER SECTIONOFROOF TYP. 100 SO. IN. CUTOUTS FOR - VENTILATION OF ROOF SECTION (SEE AD-PR-7006 FOR QUANTITIES) FLAT CENTER SECTION OF ROOF INSTALLED AT MANUFACTURER TYP. ROOF INSULATION J z CEILING PANEL—/ CENTER SECTION (FLAT TRUSS) MARRIAGE WALLS MARRIAGE WALLS FLAT CENTER SECTION NOTES: DAPIA APPROVAL' APPROVED BY PRevised Oct 25,2007 INC. MANUFACTURED HOME CTION AND SAFETY STANDARDS JACOBSEN HOMES NOTICE; +m nSPEOFICATRTHS AND DRAWINGS ORCINA, PROPraEFARY, AND O0NnDENnu DRAWN BY; O.A. 10-24-07. DATE; REV, LETTER. DRAWING TITLE: A P.O. BOX 368 MATERIALS OF JACOBSEN ����� INSTALLED PITCHED ROOF VENTS � �, MATETTULs „M PROVIDED TO DIESITE SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 REU'IENT FOR SPECFIC ROM AND MDST BE KEPT CONFIDENTIAL AND SECRET FROM OTHOM DRAWING NUMBER. AD-PR-7005 24 ROOF VENTING TV 1o0 sa K culwn FOR ~•- �r YDIwom OF Row SEcum (SEE OWT FOR REoIMMENTS) 100 SO. 1N. CUTOUT VENT HOLES N REQUIRED IN FLAT ROOF SECTIO (16n x SECTION LENGTH: CUTOUT HOLES: 0 To IS -r 1 15'-6. 10 31•-r 2 31'-r TO 46 -W 3 46'-10' TO 6 -6 4 67-6 TO -0 5 I I YARRtACE WALLS FLAT CENTER SECTION OF ROOF FACTORY INSTALLED u_I I 4ARRUCE MALLS �I cI LOW VENT LOW VENT •-r 1-s I I 050 SO. IN, VENTS REDUIRED RHIGH VENT IN SITE INSTALLED TRUSS SECTION z i .r — — — — — — — — — — — — — -- I CENTER LINE OF CENTER SECDOH (= I = xcuaN U)cwt "C" im too %m 10 A'-r we Now 4W-W A Gr-f 2 1 EIL S K 67 10 W-ir 3 2 (ASK A AMU N 10 CKWANc KMiS R I J-- TTP. 50 S0. rl ROOF VENTS +=� LOW VENT (SEE CHART FOR REOLAREYENTS) LOW VENT l MARRIAGE WALLS 1 I SITE INSTALLED CENTER SECTION OF ROOF. I NOTES' DAPIA APPROVAL- AAPPROVAL- AF PROVED BY rJUN 10 INC. MANOFAMBED HOME CONS FROM AND SAFETY STANDARDS J AC O B S E N HOMES vm vEarcArras AAm pNUm An DRCE-AWN DAM "'LETTER: LEt1ER R.R. 01-22-04 QVWAL PRWKIA". AM CON FUNNPA DRAITRIC 111LE: P.O. BOX 368 W1WOMS Or AZ SDI WWACTUIuG ROOF VENTING -� _ W- 9" MARRMS ARE FWWW 10 WC SAFETY HARBOR. FLORIDA 34695 REOVa rat 9 9 nlPM AID MW K MAIM NUMBER: PHONE (727) 726-1138 Ivi cwmaul Nos mi now ubm AD—PR-7006 i I I YARRtACE WALLS FLAT CENTER SECTION OF ROOF FACTORY INSTALLED u_I I 4ARRUCE MALLS �I cI LOW VENT LOW VENT •-r 1-s I I 050 SO. IN, VENTS REDUIRED RHIGH VENT IN SITE INSTALLED TRUSS SECTION z i .r — — — — — — — — — — — — — -- I CENTER LINE OF CENTER SECDOH (= I = xcuaN U)cwt "C" im too %m 10 A'-r we Now 4W-W A Gr-f 2 1 EIL S K 67 10 W-ir 3 2 (ASK A AMU N 10 CKWANc KMiS R I J-- TTP. 50 S0. rl ROOF VENTS +=� LOW VENT (SEE CHART FOR REOLAREYENTS) LOW VENT l MARRIAGE WALLS 1 I SITE INSTALLED CENTER SECTION OF ROOF. I NOTES' DAPIA APPROVAL- AAPPROVAL- AF PROVED BY rJUN 10 INC. MANOFAMBED HOME CONS FROM AND SAFETY STANDARDS J AC O B S E N HOMES vm vEarcArras AAm pNUm An DRCE-AWN DAM "'LETTER: LEt1ER R.R. 01-22-04 QVWAL PRWKIA". AM CON FUNNPA DRAITRIC 111LE: P.O. BOX 368 W1WOMS Or AZ SDI WWACTUIuG ROOF VENTING -� _ W- 9" MARRMS ARE FWWW 10 WC SAFETY HARBOR. FLORIDA 34695 REOVa rat 9 9 nlPM AID MW K MAIM NUMBER: PHONE (727) 726-1138 Ivi cwmaul Nos mi now ubm AD—PR-7006 i A AMU N 10 CKWANc KMiS R I J-- TTP. 50 S0. rl ROOF VENTS +=� LOW VENT (SEE CHART FOR REOLAREYENTS) LOW VENT l MARRIAGE WALLS 1 I SITE INSTALLED CENTER SECTION OF ROOF. I NOTES' DAPIA APPROVAL- AAPPROVAL- AF PROVED BY rJUN 10 INC. MANOFAMBED HOME CONS FROM AND SAFETY STANDARDS J AC O B S E N HOMES vm vEarcArras AAm pNUm An DRCE-AWN DAM "'LETTER: LEt1ER R.R. 01-22-04 QVWAL PRWKIA". AM CON FUNNPA DRAITRIC 111LE: P.O. BOX 368 W1WOMS Or AZ SDI WWACTUIuG ROOF VENTING -� _ W- 9" MARRMS ARE FWWW 10 WC SAFETY HARBOR. FLORIDA 34695 REOVa rat 9 9 nlPM AID MW K MAIM NUMBER: PHONE (727) 726-1138 Ivi cwmaul Nos mi now ubm AD—PR-7006 i i PITCHED ROOF EXTENDED VENTS SITE INSTALLED VENT CAP OR SOLAR TUBE SITE INSTALLED FLEX DUCT SITE INSTALLED VENT CAP (SEE DETAIL 'A') /SITSECTIONLLED OF ROGER VENT LAr (OR SOLAR EXTEND FLEX DUCT 3' ABOVE RAFTER SHEATHING FLEX DUCT (FACTORY INSTALLED) FACTORY INSTALLED SHEATHING — FACTORY INSTALLED CENTER EXTEND PIPE 3' ABOVE SHEATHING SECTION OF ROOF PLUMBING VENT (FACTORY INSTALLED) TYP. CONNECTION TO VENT FAN, SOLAR TUBE. OR EXTEND TO RANGE HOOD MARRIAGE WALLS CEILING PANEL P(EXTEN SITE INSTALLED UMBING VENT PIPE D 3- ABOVE ROOF) (SEE DETAIL 'B') MARRIAGE WALLS FACTORY INSTALLED FLAT CENTER SECTION XHAUST DUCT SPLIT 4ND FASTENED TO ROOF )ECKING OR BACKER KITH MIN. 4- 80, NAILS N LIEU OF FASTENING )UCT TO. VENT CAP. SITE INSTALLED FLEX DUCT SHEET METAL SCREW 0-'O'—FLEX DUCT (FACTORY INSTALLED) NOTE: EXHAUST DUCT (FLEX DUCT OR RIGID) SECURED WITH 1 SHEET METAL SCREW MINIMUM AND ALUMINUM TAPE TO SEAL AROUND DUCT AFTER SCREW IS IN PLACE. DETAIL 'A' NOTES: 1. FOR VENTS NOT SHOWN INSTALL PER MANUFACTURERS SPECIFICATIONS, 2. SEE OTHER DETAILS FOR ROOF FLASHING INSTALLATION. 3. EXHAUST DUCT MAY BE RUN THROUGH EITHER A SOUARE OR ROUND HOLE CUT N ROOF DECKING. 4. RANGE AND BATH/AIR DUALITY FLEX DUCTS TO BE SPLICED WITH ALUMINUM TAPE AS SHOWN N THE DETAIL ABOVE. 5. SECURE SITE INSTALLED PLUMBING VENT PIPE INTO COUPLER WITH APPROVED GLUE. PLUMBING VENT ROOF FLASHING (SITE INSTALLED) VENT PIPE (SITE INSTALLED) COUPLER (SITE INSTALLED) VENT PIPE 0-o-(FACTORY INSTALLED) DETAIL ' B' DAM APPRDVAI APPPOVED BY JUN INC. FEDERAL ANUFACTURED HOME --Tof l T'm eNn SAFETY STANDARDS NOTICE DRAWN BY. DATE REV. LETIER: JACO BS EN HOMES MM SPEOPIGInoK NO ORAWNM ARE R.R. 01-23-04 ORIONAL PROPRIETARY. AND CanO IM DRAWING TITLE: M P.O. BOX 368 UATDTULS OF IACOes "NLIFAC"IRW — W- SUCH MATEIEALS ARE PROVIDED TO 1IIE PITCHED ROOF EXTENDED VENTS SAFETY HARBOR. FLORIDA 34695 REOPtxT fpl SPECIF PUAPOStS AO MRl K DRAWING NUMBER: AD—PR-7007 PHONE (727) 726-1138 AWT Cm�IgL> IK 00 SECRET 1RvM M OI 26 SITE INSTALLED SHINGLE AND UNDERLAYMENT m �a m m Im ma 150 FELT TO HAVE A 6' MIN. OVERLAP AND A MIN. 6' WIDTH OF ROOF CEMENT THIS ALSO APPLIES TO ENDLAP SEAMS. r -1 r -1 'T A t FIELD INSTALLED 15j FELT MIN. INSTALLED OVER THE FACTORY INSTALLED UNDERLAWENT WITH A 6' MIN. OVERLAP AND A MIN. 6' WIDTH OF ROOF CEMENT. 15/ FELT ALSO CEMENTED WITH A 6' WIDTH AROUND ALL PENETRATIONS OF THE UNDERLAYMENT AND PERIMETER OF ROOF. . , FIELD INSTAILPD ROOF SHEATHING (TIP.) tf� I 6' WIDTH OF ROOF CEMENT WHEN I OPTMAL 15# FELT IS INSTALLED., •i 1 I OPMAL LAYER OF 151 FELT I 1 1 � I I I I I I r-j 4 ONE-FIF-a SME UNOMAY" ROOF SHEANNG MP.) THIS Row OF SHINGLES M BE FIELD INSTALLED AFTER THE UNDERLAYMENT HAS BEEN INSTALLED. THE LAST.000RSE OF FACTORY INSTALLED SHINGLES TO LEAVE A MINIMUM OF 6' FROM THE TOP OF THE SHINGLE TO THE EDGE OF THE FACTORY INSTALLED DEOQNG FOR UNDERLAYMENT OVER LAP OF 6' MINIMUM. 16 mva0"mm FASTENING DMAIL NANOZONE ILA (110 MPH) ALL EXPOSURES 1� NG OF OPTIONAL 15/ FELT IS NOT REWIRED IN ANY AREA APPROVED BY EXCEPT WHERE NOTED. Revised IN Oct 29,2007 2. FASTENING OF OPTIONAL 15 f FELT IS NOT REQUIRED. (FASTENERS APPLIED j0��j t/ a 7AINC. ARE JUST TO HOLD FELT IN PLACE UNTILSHINGLES ARE INSTALLED.) ((;; � en, •('Itivrll'IgE ��� EDERK MANUFACTURED HOME 3. SHINGLES INSTAtiEO PER MANUFACTURERS INSTALLATION INSTRUCTIONS Jig Eng. NSTRUCTIDN AND SAFETY STANDARDS ONLY WHEN SPECIFIC APPLICATIONS ARE NOT COVERED. NOTICE atAWN 8Y: O.A. DA TE: REV.�� �0-24-0� JACOBSEN HOMES >� �►� � mom QRlil►>_ PRDPfiETARx ANO OOIF1pEN111IL DRATAHtG TITIfi: n ANC YAIEIeNi Sm Comm �'� � �A�T n P.O. tiOX 366 g�101 PROY�TNE SAFETY HARBOR. FLOPoOA 34695 PHONE (613) 726-1138 re�nrt Rit sc><a1C awlo�s AID IS6f BE larl oa»Exm wo SEam Rnl onmrs ORA11/1G NUMBER: AD—PR-7008 TYPICAL FLASHING INSTALLATION ROOFING TAR UNDER NAILING FLANGE AT ALL FASTENERS TYPICAL SHINGLE ROOF 4 ROOFING TAR APPLIED OVER TYPICAL FIELD INSTALLED RAFTER FASTENERS AND UNDER ALL SHINGLES OVERLAPPING THE ROOF FLASHING. .105' X 1" MINIMUM ROOFING NAILS OR .113* X 1- MINIMUM NAILS MAY OPTIONAL SHINGLES MAY BE APPLIED TO BE USED IN LIEU OF STAPLES FOR FASTENING FLASHING TO ROOF. COVER ANY ROOF VENT FLANGE BY SECURING THE SHINGLE TO THE FLANGE AREA WITH ROOF— ING MASTIC (TAR). OPT. SOLAR TUBE INSTALLATION TYPICAL SHINGLE ROOF SOLAR TUBE DOME. MATH NAILER FLANGE. SECURED TO ROOF. ON TOP OF UNDERLAYMENT. AND TOP OF FLANGE UNDER SHINGLES. WITH BOTTOM OF FLANGE OVER SHINGLES (BOTTOM FLANGE MAY BE COVER WITH SHINGLE TABS SECURED WITH AN APPROVED CAULK). TUBE SUPPLIED BY SOLAR TUBE MAN. DANA APPROVAL NOTES: 1. ROOF FLANGE FASTENED TO SHINGLE ROOF WITH MIN. 1' X 1" X 16 GA. APPROVED BY STAPLES 6" O.C. (SHINGLES APPLIED UNDER LOWER END OF FLANGE). INC. FEDEI ALMANUFACTUREDHOME CONS RUCT ION AND SAFETY STANDARDS JACOBSEN HOMES NOTICE: IWSE WonCA, S AW MA.NMAla< DRAWN BY: T DATE 02-04=04 REV. LETTER DRAWING TITLE: OMML PROPRI U". AW COHMIM „ YAIFAOALS 9F iMMOSDO YAN WACnM6 TYP. FLASHING INSTALLATION - DRAWING WYA3(R AO-PR-7W9 SAFETY HARBOR• FLORIDA 34695 PHONE (813) 726-1130 II[EGMII Fat SiW REPOSES NO MAT K KM CW1DLMUK Also SE01:1 FPOY 00M 28 ADDENDUM GENERAL NOTES / TIE -DOWNS NOTES: is FRAME TIE -DOWNS SHALL BE INSTALLED TO PROPERLY SECURE THE HOME. 2. VERTICAL TIE -DOWNS ARE REOUIRED IN ADDITION TO THE FRAME TIE -DOWNS. I VERTICAL TIES MAY BE SECURED TO THE SAME GROUND ANCHOR AS THE FRAME TIE-CCV,yS WiEi1 A DOUBLE HEADED ANCHOR IS USED AND IS CAPABLE OF RESISTING THE COMBINED LOADING. Mil ANCHORS ARE NOT INSTALLED AT THE ANGLES) SPECIFIED IN THE TABLE(S), A STABILIZER PLATE MUST BE INSTALLED IN ACCORDANCE WiTH THE ANCHOR MANUFACTURER'S INSTRUCTIONS. 4. FRAME TiE-DOWNS AND ANCHORS ARE NOT SUPPLIED BY JACOBSEN HOMES (TO BE SUPPLIED BY OTHERS). 5. VERTICAL TiE STRAPS MAY BE SUPPLIED BY JACOBSEN HOMES OR ANCHOR BRACKET MAY BE INSTALLED BY JACOBSEN HOMES FOR ATTACHMENT OF VERTICAL TIE STRAPS, IN EITHER CASE ALL ANCHORS AND END TIEATMENiS ARE TO BE SUPPLIED BY OTHERS. 6. ALL GROUND ANCHORS AND FRAME TiES SHALL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. GROUND ANCHORS AND FRAME TiES ARE NOT TO EXTEND BEYOND THE EXTERIOR WALL OF TiHE UNIT. 7. STEEL ANCHORING EQUIPMENT EXPOSED TO THE WEATHER SHALL BE PROTECTED WITH A MIN. OF 0.30 OZ. OF ZINC COATING PER SQUARE FOOT OF STiEL & DESIGN BASED ON 95 1/2' I -BEAM SPACING AND A MAXIMUM SIDEWALL HEIGHT OF 8'-D' (82' I -BEAM SPACING IS ACCEPTABLE FOR 10' WIDE SECTIONS OF MULTi-WIDE UNITS W/ 90' SIDEWALL HEIGHT ONLY). 9. LONGITUDINAL TiES SHALL BE INSTALLED ON THE INSIDE OF EACH I -BEAM AT THE CROSS -MEMBER LOCATIONS OR PER ALTERNATE DETAILS IN ACCORDANCE WITH THE SPACING TABLES AND NOTES 4, 6, 7 AHD 16. 10. FRAME TIE -DOWNS SHALL BE 'WRAPPED' AROUND THE MAN I -BEAM (AS SHOWN ON T)P. CROSS-SECTION DETAILS) AND SHALL COME OFF THE TOP FLANGE OF THE I -BEAM WITH AN APPROVED BUCKLE OR LOOP. 11. ANCHORS SHOULD BE CERTiFIED FOR THESE CONDITIONS BY A PROFESSIONAL ENGINEER ARCHITECT OR A NATIONALLY RECOGNIZED TESTING LABORATORY AS TO THEIR RESISTANCE BASED ON THE INSTALLED ANGLE OF THE DIAGONAL TiE AND/OR VERTICAL LOADING AND ANGLE OF ANCHOR INSTALLATION AND TYPE OF SOIL IN WIIICN THE ANCHOR IS TO BE INSTALLED. 12. GROUND ANCHORS SHOULD BE EMBEDDED BELOW THE FROST LINE AND BE AT LEAST 12' ABOVE THE WATER TABLE. 13. GROUND ANCHORS SHOULD BE INSTALLED TO THEIR FULL DEPTH, AND STABILIZER PLATES SHOULD BE INSTALLED TO PROVIDE ADDED RESISTANCE TO OVERTURNING OR SLIDING FORCES 14. 'ANCHORING EQUIPMENT SHOULD BE BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT TO RESIST THESE SPECIFIED FORCES IN ACCORDANCE WiTH TESTING PROCEDURES N ASTM STANDARD SPECIFICATION D3593-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL AND SEALS, 15. ALL GROIRID ANCHORS TO BE RATED FOR LOAD LISTED IN TABLES, TIMES 1.5 SAFETY FACTOR OR AN ULTIMATE LOAD OF 47251 (31501 DESIGN LOAD), WHICHEVER IS GREATER VALUES IN THE TABLES ARE DESIGN LOAD VALUES. 16. A MAXIMUM OF TWO LONGITUDINAL TIE -DOWN STRAPS MAY BE INSTALLED AT A SINGLE CROSS -MEMBER LOCATION. IF MORE THAN TWO LONGITUDINAL TiE-DOWNS ARE REQUIRED (SEE APPROPRIATE SPACING TABLES) ADDITIONAL CROSS - MEMBERS MUST BE USED FOR ATTACHMENT OF STRAP(S) (OR SEE OTHER DETAILS FOR ALTERNATE STRAP ATTACHMENT). 17. LONGITUDINAL TiE-DOWN STRAP(S) MAY BE INSTALLED AT AN ANGLE NOT PERPENDICULAR TO THE CROSS -MEMBER TO WHICH IT IS ATTACHED (SEE NOTE 16) IF REQUIRED TO MISS PIER LOCATIONS OR OTHER OBSTRUCTiON(S). I& ALL FIGURES (DETAILS) SHOWN IN THIS SECTION ARE TYPICALS ONLY. REFER TO THE APPROPRIATE TABLES FOR THE REWIRED NUMBER, SPACING AND/OR SPECS OF SPECIFIC TIE -DOWNS AND ANCHORS REQUIRED. 19. SEE OTHER DETAILS IN THE SET-UP MANUAL AND ADDENDUM FOR BLOCKRiG REQUIREMENTS. ALL BLOCKING DETAILS CONTAINED WITHIN THIS MANUAL ARE APPLICABLE FOR ALL ZONES AND ALL EXPOSURES NOTES: ENGINEER `/� ••�ll/!////' DAP IA APPROVAL' c�',L ROVED BY th. ,.. THESE NOTES AND DETAILS ARE APPLLCABLE ;•``�`�O�.�C,iSTER = •Q No. O':. 5 10 FOR WIND ZONE II AND/OR WIND ZONE III. THEY — ENE8703571.. JUN 1 ARE ALSO APPLICABLE TO BOTH EXPOSURE 'C' AND EXPOSURE V. SEE APPROPRIATE TABLES = .� INC.v FOR .SPECIFIC INFORMATION ON EACH. •, TAjC NOW ., •.tipi.AN. JACOBSEN HOMES NOTICE /nlll iNESE SPEancooNS AND DOWNM ARE 1 M1. ► o . C.L.Y. DALE, 5-19-95 REV. LEM. DRAWING TIU- TD-GENERAL NOTES P.O. BOX 368 OIEONN. PROPRIETMY. AND ODNitOEm 11ATERI&S OF JACOMN MMWACMN6 n /-i SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 °K SUCH MATERIALS SKCFX AR[ FRONDED To 1BE RECPlNi FOR �ECi1C P{RP'0615 A10 1515E � *PT w+eMU& No SECIV M Or"& ORAMtNC NUY$ER AD-TD-0001 29 ADDENDUM NORMAL TIE -DOWN SPACING TABLES 1 ZONE II & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE (+ MIN. WIND ZONE II WIND ZONE III Y'N• Drc ANCHOR YIN 0TY. ANCHOR V FLOOR WIDTH EA. END N EA. END OF ANGLE O Ell SECTION YIN.. 6 EA SECTION Y;N. B 20'-0' 2 36' 2 45' 24'-0 2 46' 2 60' 25'-4' 2 1 50' 3 38' 26'-8' 2 54' 3 41' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE h W1ND ZONE III SPACING DEL HEAD DELANCHOR ANGLE SPACING DBE. HEAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 20'-0' 12' 8'-0' 31501 40'-50' 6'-8' 3150# 40'-50' 24'-O' .12' 8'-0' 31501 40'-50' 6'-8' 31501 40'-50' 25'-4' 12' 8'-0' 1 31501 40'-50' 6'-8' 3150 40'-50' 26'-8' 12" 8'-0' 31501 40'-50' 6'-8' 3150 40'-50' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III MIN. OTY. EA. END ANCHOR AN YIN OTY. EA. END OFANGLE ANCHOR FLOOR O v WIDTH EA. SECTION YIN.. 6 EA. SECTION YIN.. 9 20'-0' 2 50' 2 68' 1 24'-0' 2 70' 3 50' 25'-4' 3 45' 3 60' 26'-8' 3 45' 3 60' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE Ili SPACING DOL HEAD ANCHOR ANGLE SPACING DBE. HEAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD LOAD 20'-0' 12' 5'-4' 31501 40'-45' 4'-0' 31501 40'-50' 24'-0' 12' 5'-4' 3150IT 40'-50' 4'-0' 3150# 40'-50' 25-4' 12' -4' 1 31501 4D'-50' 4'-0' 31501 40'-50' 26'-8' 12' 54 31501 40'-50' LTTI LIEIIII/ '-0' 3150# 40'-50' OTES: � - ENGINEER` O " DAPIA APPROVAL 1. SEE AD-TTT-D001 FOR ADDITIONAL REOUDTEMENTS. ``�Q�` • G\STER � � ; ''Q, lc •,�� a Q No. o •. APPROVED BYE ; 2. SEE AD- D �p1OR MAXIMUM PIER HEIGHTS REWIRED FOR THE LOADS ENE8 .111N 1 5 OF INC. �''%'rE` •' •.. D I A� • • G\� .�` CCtSIAUCTp1 NO SAFER SINfJ4F� JACOBSEN HOMES NOTICE THESE sPEonunons AND DRA.AHcs ARE 11AAk�LD .. C.L.Y. DATE: 5-30-95 REV. LETTER: P.O. BOX 368 WGINAL. PROMETARY. AND CONIIDENRAL MATERIALS CF JACOOSEN UAMJFACIMINO ARE PROND(D TO THE n „ DRAWING TITLE: NORM. SPACING TABLES SAFETY ONER(813) FLORIDA 261D 138 W_ SUCH MAIERULS OUT c Kopera� of k ko SEO srKm � /H` DRAWING NUMBER AD-TD-0010 30 ADDENDUM 11 ALTERNATE TIE —DOWN SPACING TABLES '� wl-oo�>> ZONE Il & III/EXP. C �4 LONGITUDINAL TIE —DOWN SPACING TABLE MIN. END ZONE n END ZONE N etff � �O mm ` C WDTH Ek SECTNN OL a EL SFT:RG11 Y16 6 o� 23'-V 2 54' 3 40' 244 2 54' 3 40' 25'4 2 60' 3 44' 3ir 3 46' 30'-8' 3 4T 4 41' (SEE NOTE 14 FOR ANCHOR ANGLES) VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN, MAX. WKD ZONE II WIND ZONE 11 sPAaNs s L Wm ANm ML SPACM EL HEAD Lo mm ANRE FLOOR EAVE 00 Ova"G LOAD Z-4' 12' 5-4' 3154 40=45' 5-4' 3150t 35-40' 24'-0' 12' 54 3150i 40'-45' 5-4' 3150# 35'-40' 254 12' 54 31501 40'-45' 64 31501. 1 35'-40' 26'-8' 12' S-4' 31501 40=45 .54 3154f 1 35'-40' 31501 40=45' 5-4' 3154 3T-40' (SEE NOTE #4 FOR ANCHOR ANGLES) % C �� ... . O . • i• No 45484 • _ • `c'TA'' - m m�mAT� REF. CALC. :'c4 H P ••`�2`e`� C-TD - 215.01 - 215.20. N A`? �o ENWW APPROVAL• Ow APPROVAL NOTEL 1 5EF AD-ID-W FOR AMMONAL REQUlR¢147i1S APPROVED BY ft�= 2 SEE AD-ID-CO11.1 FOR wmm M HEIGHTS RFAUBtED FM 11ff LOADS TA91A M AMqNPINC. 16,2009 -M-MM TO DOWN WES ONLY. 3, D= ON THIS PAGE APPUGW 4. "M Man ANGLE SHOVti DI THE CHART ABOVE CANNOT BE ACHEVED, FEDENAL IWIIFAL7URED XO�E WNSTRUCf1ON AND SAFETY STANDARDS . DBIALLED AN APPROVED STAKW PLATE. MOM BY; JACOBSEN HOMES -Tm�►Pm M.T.os-04—os DATE REV. LETTER aaaoa�u. aA1 AT1wIAlS a mono YAMIFACRATND Moo YoR =- MLTERNATE SPACING TABLES —' P.O. BOX 366 RC 9X H YAM S AK PROIOED TO TIE OWEDSAFETY HAt�OR. FLORIDA 34595 WMI RA SM PU W AID Em K MANG KOM LLLU PH2 (613) 726-1136 WT COMM AND SEW FFMam AD-TD-0010'1 31 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SN(NMNr TIF-IIOWN SPACINGS MA& rm ow-W-wau IIWIL rm /WATT-wry . V ran rv-.r — ..+ — .. .....• . .__ -_ -_ _- TYPICAL CROSS SECTION SHOWING TIEDOWNS FIGURE 1.0 SEE FIGURE EO FOR ALTERNATE M-DOIRI IMOD FIGURE 1.1 SEE FIGURE 5.0 FOR ALTERNATE TE-DOWN NOTES: N �.• ..v�O ,,,�� 1. SEE AD-TD-0010 FOR SPAaHG TABLES ���•��>��. ••G�STEg�2 FQi ISEE AD-TD-0010 FOR QUA ITY OF LONG17WAL TIE -DOWN STRAPS REQUIRED. � Q� No' . 3. SEE OTHER DETAILS FOR BLOaONG (PIER) QUANTITY AND OTHER REOUIREIAENTS. _ ENE8703571 =. 4. SEE AD-TD-0001 FOR ADDIIHONAL REOUNUENTS. 5. ZONE 2/DPOSURE V. 60' 4AX4UIY HEIGHT � '� : CJT�� ZONE 2/EX MIRE V: 44' YA1011UM HEIGHT /1jPl// 4j Q�.• • �� ZONE 3/DPOSURE 'C: 40' NAXPAUN HEIGHT '�'����••', CIA '•����� ZONE 3/E7f MRE V: 36' YAXIIRIY HEIGHT ����i�siS//i u 1 • E� .����` SEE NOTE 5 FOR NAWN HEIGHT REF. CALCS: ;flpC"1 1. I 7-(XTA INC, JACOBSEN HOMES NOMC& -• �� �� uax sPEancams AND DRAWM3 C.L.Y. 3-27-95 MORAL. PROPFIiURY. AND OWUNTIN. DRAYANG TITLE: „ P.O. BOX 368 NATERULS OF JACOBSEN NANUFACIURMG FIGURES 1.0 AND 1.1 NG SUCN NAWMS ARE PR MM TO 11E SAFETY HARBOR, FLORIDA 34695 WPM FOR 9ECFIC PlnvM AND WST BE DRAWING NUYBM' PHONE (813) 726-1138 WT CONFWU& NO SECRET FROM 0"M AD-TD-0011 32 ADDENDUM RECOMMENDED TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION cumaki r mr_IVINIAI CDA(`IFdm FIGURE 1.0 0 owill D"911j.11 a . No 4 .. ► e 09 o p�:1���,.. • TYPICAL CROSS SECTION TYP. ata�-yet A�►A— -�a0 MOWING � 11EDOWNS F1AOR sYsra� 'Beep®Ea"ae,eeo� ausgs SFE NOTE 5 FOA I wAw ww �-- ANCHM ANaE (ff IM P) ANCHOR ANNE (SEE KNEE ps) —+ FIGURE 1.1 OMIX RASED ON 9511f 1-REAH CE1dTERs Alm 96' 10 SOKS). NUE : APPROVED BY 1. SEE AD-TO-OD10.1 FOR SPACING TAFILES 2- SEE AD-TD-0010.1 FOR QUM" OF LONG111ANAL TIE-COM STRAPS REQIARED. ,hm 16,2009 NAINC. 3 SEE o1HFR DETAILS FOR •BLOCHING (PER) QUANDTr AND OTHER REQIARFiIENTs 4. SEE AD-•TD-Mm MR ADDI00NAL REQUIREMENTS. FEDERAL IWNiACRI ED NONE . CONSTR=ON AND SAHTY STANDARDS 5. ZONE 2/Ef0'0511RE 'C: 67• MASUM HE16HT ZONE 3/EfO' RARE 'C: 56• MAMMUY HEIGHT REF. CALCS: 6. *EN ANCHOR ANGLE SHORAN ON AD-7D-0010.1 CANNOT BE ACHIEVED, C-TD- 215.01 - 215.20 INSTALL AN APPROVED STAEB M PLATE NOTICE DRA1xa BY: M.T. DATE 06-04-09 REV lET1TR. JAC O B S EN HOMES 7103E 5P17pACAmms m NAWI m fm ems ' G D�WNc ' FIGURES 1.0 AND 1.1 N + MMF P.O. BOX 368 I1C. SUCH NAIF = AK F11011= M 11E SAFETY HARBOR. FLORIDA 34695 BBB FOR 91 FtiP0e:5 MD MST E DRAWING NUMBER COMAIFNIN l� SET FRdI OD= AD-TD-0011.1 ❑ PHONE (813) 726-1136 l6PT 33 ADDENDUM ��'�' v5 NORMAL TIE -DOWN SPACING TABLES 1 ZONE 1I & III/EXP. C & D LONGITUDINAL TIE -DOWN SPACING TABLE (+� LAIN. WIND ZONE 11 WIND ZONE III YW OTY. ANCHOR YIN OTT. ANCHOR FLOOR WIDTH EA END OF ANGLE EA. END CF AHGIE O� EA SccnON YIN. A EA CTICN MIN. B 12'-0' 2 43' 2 55' �1]4 jjU� 13'-4' 2 50' 2 68' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DEL DEL HEAD ANCHOR ANGLE SPSPACINGANCHOR DBL HEAD ANGLE FLOOR EAVE WIDTH OVERHANG LOAD 12'-0' 6' 8'-O' 315Oj 40'-50' 6'-8' 3150# 40'-50' 13'-4' 6' B'-O' 31501 40'-50' 6'-8' 3150# 40'-50' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III . YIN. OTT ANCHOR UK OTY. ANCHOR FLOOR WIDTH EA. END N EA. END NGLE 0 EA SECTION YIN.. B EA SECTION uIH6 12'-O' 2 64' 3 47' �1 12'-0' 3 1 37' 4 33' 3 42' 3 55' 4 30' 4 38' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. PAND ZONE II WIND ZONE III SPACING DEL HEAD ANCHOR ANGLE SPACING DBL. HEAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD LOAD 12'-0" 6' 5'-4' 31501 40'-45' 4'-0* 3150Q 40'-50' 13'-4" 6' 54 3150A 40'-50' 4'-0' 3150# 40'-50' NOTES:ENpNEER�w` 0� DAPIA APPROVAL 1. SEE AD-m-0001 FOR ADDInONAL REOUIREMENTS �.` Qx •'' �gTE �� 4- APPROVED BYE. 2. SEE AD-lD-0013 FOR MAXIMUM PIER HEIGHTS REOLARED FOR THE LOADS TABULATED ABDW. ENE8703571 ' =IN IN 1 5 3. MAX EAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRONT OR REAR. * ' INC, 4. ABOVE TABLES APPLY TO 160" FLOOR OR 144• FLOOR MOTHS MATH 95 1/2' I SPACING 96- YAXIMLD1 SIDEWALL HOGHT AND 6- MAXIMUM SIDE STAT^ F ��� �+1 �`''• /^/ �' �` FLJARL,®« �M=awasvtlrsluoM+oo -BEAM OVERHANG (6' OVERHANG MAX EACH SIDE OF UNIT). - F . 01A -if ... N'''(j J AC O B S E N HOMES NOTICE: /IIIII 11 TNEsE SPEa'1CAT0iS AND DRAWNGS ARE! 1111""C. L. Y. DATE: 5- 30- 9 5 REV. LETTER: P.O. BOX 368 CAGNAL. PROPWART. AND COMDEHTLAL MATERIALS OF JACOBSEN MAWFACTLRING LNc SJCH uAIEMkS ARE PROMED TO THE DRAINING TITLE: NORM. SPACING TABLES „ SAFETY HARBOR, FLORIDA 34695 RECHM FOR 9PE01C R .?M AND Y15T BE DRAWNG NUMBER: PHONE (813) 726-1138 KEPT Wf(07 A AM SECRET FROu OTHERS AD-TD-0012 34 ADDENDUM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS TYPICAL CROSS SECTION SHOWING TIEDOWNS TIE -DOWN SYSTEM FIGURE 1.2. SEE FIGURE 2.0 FOR ALTEIDLATE TIE-1100 )=D iu t AN61F FIGURE 1.3 SEB FIGURB 7.0 FOR ALT&RRATE TR-MU WRID SEE NOTE 5 FOR MAM HEIGHT NOTES: EAR'` C D�►�F ��'', DAPIA APPROVAL,. SEE AD-TD-o012 FOR SPACING TABLES AND NOTES 2. SEE AD-TD-0012 FOR DUAIM OF LONGLTUDIAL TIE STRAPS REQUIRED ;sTE� ,0 •, APPROVED BY -DOWN No. 3. SEE OTHER DETAILS FOR BLOCIONG (PIER) OUAN71TY AND OTHER REOUREWM �► 4. SEE AD-TD-0001 FOR ADDITIONAL REOUREMENTS o EN 870357 _ JAN i i -5. ZONE 2/DFO%RE V. 30' MAXWM HEIGHT � ZONE 2/00 MRE V: 48' MAXOAUM HEIGHT - 3/EXPOSURE •C" :•� � OF ` INC ZONE 28' MAXOM LIEIGHT 06!dd ZONE 3AWOS11RE V. W MAXDAUM HEIGHT �NP JACOBSEN HOMES NOME ��/�� , SPECFICATIONS MeDRAw�fli 1PR ✓�' tits"' C.L.Y. DATE 5-19-95 REV LETTER. DRAPANG 11TLE FIGURES 1.2 AND 1.3 min P.O. Box 368 MA70dk PROvieETutY• M M/TQtl� °MNS A SAFETY HARBOR, FLORIDA 34695 A"4ANNATPWAND Re m FoRR � wm me WLW K DRAWIRG NUMBER: AD-TD-0013 PHONE (813) 726-1138 IVT CM FWMX M v sir rRw omm. ,oe ADDENDUM ALTERNATE TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS FIGURE 2.0 SEE FIGURES 1.1 AND 1.3 FOR TYP. CROSS-SECTION(S) ..TununuN,.. NOTES •G\S hi �A`py�' gppAOVAL.; Q .•.FZ'�. DAPIA APPROVAPPROVAL�� 1. SEE AD-TD-OD10 FOR SPAONG TABLES Q� No. FO �' ': APPROVED BY 2. SEE AD-TD-0010 FOR OUANITY OF LONGITUDIAL TIE-DOW STRAPS REWIRED. - ENE8703571 �_ 3. SEE OTHER DETAILS FOR BLOOIONG (PIER) QUANTITY AND OTHER REOU MENTS _ '• IN Jug• 5 4. SEE AD-TD-0001 FOR ADDITIONAL REQUIREUENTS - I INC' ;, • . D1A �� ��. ,.I . .. v caatnucTONANosANET'rSwDeDf "%SJ Af EN `,. A� ,/1„0 , `�. JACOBSEN HOMES NOi7CE: THESE SPECIFICATIONS AND DRAVANGS ARE DRAWN BY: C.L.Y. DATE: 5-19795 REV. LETTER: P.O. BOX 368 ORIGINAL• PRGPRELRY• AND OCNrMTIAL MATERIALS OF JACOBSEN LIA"ACTURINC INC. SUCH MATEitkS WE P"00 TOM DRAWING TITLE: FIGURE 2.0 A SAFETY HARBOR. FLORIDA U695 PHONE (813) 726-1138 RECIPIENT FOR SPEanC PP 00 AND wsT BE PVT OONFDDITIA• AND FLOO "= OHM DRAWING NUMBER AD-TD-0014 ADDENDUM ALTERNATE TIE -DON SYSTEMS) ALTERNATE LONGITUDINAL TIE-DOWIN INSTALLATION METHODS SIDE VIEW OF MAIN FRAM_ 00 TF.-DOWN STRAP SEE OTHER OETAKLS FOR TIE -DOWN STRAP SPECIFICATIONS APPROVED ANCHOR WELDED TO MAIN I-EEAM (SEE OTHER OETA13 SET AO-TD-0200 FOR FOR VaONG) TO BE INSTALLED' RADIUS CUP DETAILS AT W FACTORY. (REWIRED INS LOCATION). (MIN. 31501 WORKING (DESI;N) LOAD AND 47251 ULTMATE LOAD-) o GROUND ANCHOR ° SEE OTHER DETAILS FOR Siff, ANGLE AND OTHER INSTALLATION NOTES ( I I I� (• FIGURE 2.1 SOLID HEADER (CROSSMEMBER) 3' x 3/4' (= 1/2) .MUST BE LOCATED FRONT VIEW CUT INTO HEADER FOR STRAP ATTACh%0 T. W1TNN 5' OF MAIN (FACTORY OJT) CHASES i-BEALL Pam / SEE AO-TD-0200 FOR j SEE AD-'•D-G203 FO4 / RADII!S Clh' DETAILS I RADIUS CLIP DETALS !! (REQARED THIS LOCAiIONj (REQUIRED THIS LOCATION). —1 5' MAX • I TIE-DOYM STRAP 5EE OTHER CSAKLS SIDE VXW FOR TIE -DOWN STRAP SPECIFICATIONS GROUND AND OR' ° SEE OTHER DETAILS FOR SIZE, A.vGE AN3 OVER INSTALLATION NC-S. FIGURE 2.2 NOTFS " _ LER APPROVAL : . �. DAP:A APROVAU CAA�ca�. ,•. ra EN Ems.?. r.. 1. SEE AD-TD410 FOR SPACING TABLES 2 TD- SEE AD-OD10 FOR OUANIIY OF LONGITUDIAL TIE-DDwN STRAPS RCOUf2ED. �O TAT. c ' : r','.' •� x ~ y . 3. SEE OTHER DETAILS FOR BLOCKING (PER) QUANTITY AND OrAER REOVMRENENTS. 4. SEE AD-ID-0001 FOR ADDRANAL REOUIREMENTS '�� • ' +!!f ; Agar BRACKET AND TL-DOWN DEVICES ARE CERTIFIED BY OTHERS CRAWN BY. OAi�. REV. LETTER: JACOBSEN HOMES T;C.L.Y., s-13-95 TN=iE �E[SFICABMONS MAN2 ] CRAt1fACS ARC ofQI X. rRP°Rf1ART. A11] coax w►: DRAINING PILE' �� P.O. Box 363 "A� or"1Com °wfAC=r— FIGURES 2.1 & 2.2 SAFETY HARBOR, FLORIDA 34625 WOF01 FOR 1PECnC ROM ANI UM 1E DRAWING NUMBER PHONE (813) 726-1138 Co mD jA1. *3 swET ntce oHn AD— TD-0015 LONGITUDINAL STRAP ATTACHMENT TYpla TYPICAL LONGITUDINAL ANCHOR STRAP (FIELD INSTALLED) NOTES: ' 1. SEE OTHER DETAILS FOR STRAP PROTECTION AT ALL SHARP CORNERS 2. ALL STRAPS TO BE TYPE 1, FINISH B, GRADE 1 STEEL STRAPPING, 1 1/4' WIDE AND 0.035 INCHES IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D 3953-91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. 1M CLAMP, MANUFACURED BY ENGINEERING. PART y 59011 R�« «w.urACTURER'a INS IRRUC T10N5 FOR COMPLETE INSTALLATION DETAILS) A PROVED BY TIN" jljN 15 - M 1p INC. EDE AL MANUFACTURED HOME ,ON RUCTION AND SAFELY STANDARDS 'JACOBSEN BIOMES THESE sPEOFICTITIONSiAANO DRAVDIGS ARE DRAWN BY: M.T. DATE: 6-12-01 REV. LETTER; ' ORIGINAL, PROPRIETARY, AND COWDENDAL DRAWING TITLE: MAIERIALS OF JACOBSEN MANUFACTURING P.O. BOX 36B• INc sua MAIEReALs ARE PRONRxo 10 iNE LONGITUDINAL STRAP ATTACHMENT SAFETY HARBOR. FLORIDA 34595 REa+ENT FOR 9Wu PWDSB AND uusT BE DRAWING NUMBER: PHONE (727) 726-1138 9M CONFi O MAL AND 9Wl7 FROM OTHERS AD— TD—OO16. 38 ADDENDUM �g�s S%t 'V� , OWNS S , OFFSET UNIT TIE —DOWN PACING TABLE S N ZONE II & III/EXP. C & D LONGITUDINAL TIE —DOWN SPACING TABLE (�1 MIN. WIND ZONE II WIND ZONE 01 a. OTY. ANCHOR UK 011. uia40R FLOOR WIDTH EA. END of EA END ON ANGLE EA gcTRTN UKKN. a E.A. SECTION NItL e 10'-0' 2 44' 2 56' 12'-0 2 57' 3 42' 13'-4' . 3 .38. 3 50' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DIE.. WA LOAD ANCHOR ANGLE SPACING Od. NEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 12' 4'-0' 31501 40'-50' 4'-0"_ 31501 40'-50' 12' 4'-0' 3DO01 40'-50' 4'-O' 31501 40'-50' 13'-4" 12' 5'-3' 31501 40'-50' 4'-0* 30001 40'-5T LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III UK OTT. Ell END OF ANCHOR UK OTY. Ell END OF ANCHOR ANGLE FLOOR O WIDTH FA SECTION IN. - B UK fA SECTION uut B 10'-0' 2 64' 3 46' 12'-0' 3 50' 3 68' 3 58' 4 48' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING -TABLE MIN. MAX. WIND ZONE II VAND ZONE III SPApNC M HE1J LOAD ANCHOR ANGLE SPACING HEADANCHOR DOL. HEADWIDTH ANGLE FLOOR EAVE OVERHANG 10'-0" 12' 4'-0' 3150g 40'-50' 2'-8' 31501 40'-50' 12'-0" 12' 4'-0' 31001 40'-50' 2'-8- 31501 40'-5D' 13'-4" 12" 4'-0' 3065 40'-50' ­111111NOTES: 2'-8'- 3000+ 40'-50' Tlla` �� GavAl����� A ire VD BY 1. OFFSET SECTION RTTH THE MARRIAGE LWE WALL EXTENDWG BEYOND THE ENDWALL OF MUST BE TIED DOW AT THE MARRIAGE LINE IN ACCORDE` 0 ,•'G\STfir? �"' C� •'• do,ANC REVISED THE ADJACENT SECTION WITH THE TABLES ABOVE: THE SIDEWALK SIDE AND THE ADJACENT SEC71ON(S) ARE TOC SEP 0 9 1 BE TIED DOWN W ACCORDANCE WITH THE NORMAL SPACWG TABLES (AD-TD-DO10). . �I C. I' 2. SEE AD-M Ob01 FOR ADDITIONAL REQUIREMENTS. '� ^; � ' •���� `� HOME ]. SEE AD-7D-0021 FOR NAlODUM PIER HEIGHT REWIRED FOR THE LOADS TABULATED if�' •!n9�gbr � � ,•��IQr...•' ��`�� FED i�i4 • CO RAL MANUFACTURED STRUCTION AND SAFETY STAND ABOVE tis ....•• ��,�� J AC O B S E N HOMES NOTICE: 'Until1 ELT< ` DATE THESE SKOnCAnONS Afro DRAWAM ARE R.R. 8_27-96 REV. LETTM P.O. BOX 368 CRUNAL. PROPPJETARY. AND CCAIFroFJITIK DRAWING MU: UATMALS OF JACOM MAWFACROIC OFFSET SPACING TABLESPC. D IL Jl SAFETY HARBOR. FLORIDA 34695 PHONE (613) 726-1138 SXH AIM PROMDED TO TK REEOPINT roR SPt� PJPMS AND WA1 !f VIPT CDNDENME A10 SECRET TRW OTHERS ORAnwG NUUDER AD—TD-0020 39 ADDENDUM OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE -DOWN SPACINGS ti FIGURE 3.0 SEE FIGURE 4.0 FOR ALTERNATE M-DOWN METHOD TYP. CROSS SECTION(S) SHOWING iIEDOWNS SEE NOTE 5 FOR NA)OJNII H11"T ANGLE Mu FIGURE 3.1 SEE MUM 6.0 FOR ALTERNATE TIE -DON METHOD NOTES: I. SEE AD-TD-0020 FOR SPACING TABLES (OFFSET SECTION ONLY). 2. SEE AD-TD-0020 FOR OLIMITY OF LONGITUDUIL TIE -DOWN STRAPS REOUIRED. (OFFSET SECTION ONLY) 3. SEE OTHER DETAILS FOR BLOCIONG (PIER) OUANTITY AND OTHER REQUIREMENTS. 4. SEE AD-TD-0001 FOR ADDITIONAL REOUIREMENTS. 5. ZONE 2/EXPOSURE 'C: 44' MAXIMUM HEIGHT ZONE 2/EXPOSURE V: 24' MAXIMUM HEIGHT (32- ® 24' WIDE MIN.) ZONE 3/EXPOSURE 'C': 32' MAXIMUM HEIGHT ZONE 3/EXPOSURE V: 32' MAXILIUM HEIGHT (44' 0 24' WIDE MIN.) [TARES ON AD-7D-0020 DO NOT APPLY TO DIM STANOARD 1AXII-WIDE SECRONS OF THE UNR -SEE NOTE 1. AD-TD-0020.) TYP. FLOOR SYST017 T1P. ANm Mal Mp{0R FIGURE 3.2 ulgIFII ALTERNATE TIE -DOWN METHOD �i DANA APPROVAL ���•���sTFq.4F'-. y, N0. Fo''?' APPROVED BYE ENE870357lNf 4, c � � f,''•'/,j��lll'►�•••�v ` iEDfMi M�1MFAcf1�IpE �.� ``�. walnrcrp„vos�TTswrw�o ''*,f/4 NAL E...���` El=JACOBSEN HOMES NO DRAWN BY: C.L.Y. DATE REV. LETTER: ■ TNESE SPECIFICAnoNS AND AND DRAYANGS ARE ORIGNAL. PROPRIETARY, AND CONFRIFNTIAL 5-11-95 ❑„❑ P.O. BOX 368 MATERIALS OF JACOBSEN MANUFACTURING AM DRAWING TITLE FIG, 3.0, 3.1 & 3.2 H SAFETY HARBOR, FLORIDA 34695 PHONE �T F RASPE�a1CS PW SE � MIST BE DRAWING NUMBER: (813) 726-1138 APT COfiWRA1 AND SEOV FROM OHM AD-TD-0021 40 t ADDENDUM ALTERNATE OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWING TIE -DOWN. SPACINGS FIGURE 4.0 SEE FIGURES 3.1 AND 3.2 FOR TYP. CROSS-SECTION NOTES: tkw,% AYp"Ovl1lU�'"i,� DAPIA APPROVAL 1. SEE AD-TD-0020 FOR SPACv� TAMS (OFFSET SECTION ONLY). ` `iOrr`�_,G�STERF F2%-, APPROVED BY. 2 SFE AO-iD-0020 FOR WANITY OF LONp11AlAL TIE-DOYM STRAPS REQUIRED. No. o ; (OFFSET SECT" ONLY) h'E8703571" S 5 3. SEE OTHER DETAILS FOR 1£00014C (PIER) QUANTITY AND OTHER REO MAENTS = _ 4. SEE AD-TD-ODDI FOR ADDITICf:AL REQUIREMENTS. T.' Q INC �UTW •'C��• ��` wousmo�wourt„swcrq JACOBSEN HOMES P.O. BOX 368 NO "" iHESE sPEonunorIS ts AN0 AW oRAwtxs ARE LRONAL PROPWA". AND MWMTK YA7ERI a a ueoli9al YA"' ACMUC �A1+++ 8Y:. C.L.1'. DATE 5-11-95 REV LETTTit A DRAIANG TITLL FIG. 4.0 SAFETY HAR-c _�, FLORIDA 34695 INL SXCH YAIFR LALS AK PRM= 70 K REW104 M 9KCFY MWOM NO SM DRAWING NUMBER PHONE (813) 726-1138 Ivi cONmnk NO Nov nu OHM AO—TO-0022 411 ADDENDUM ALTERNATE UNIT TIE -DOWN SPACING TABLES rD Q ZONE II & III/EXP. C & D / LONGITUDINAL TIE -DOWN SPACING TABLE E+1 MIN. VAND ZONE 11 WIND ZONE III UIN. OTY. ANCHOR MIX CITY. ANCHOR �J FLOOR WIDTH [A ENO EA. END Or ANGLE " O� ON EA. SECTION IN. YIN. B EA. SECTION WIN. 6 20'-0' 2 36' 2 45' 24'-0' 2 46' 2 60' 25'-4' 2 50' 2 67' 55' 3 30. VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBL HEAD ANCHOR ANGLE SPACING DBL. HEAD LOAD ANCHOR ANGLE FLOOR MOT20'-0" OVERHANG 12" 4'-0' 36701 20' 4'-0' 39005 20' 24'-0* 12' 4'-0' 37001 20' 4'-0' 3950g 20' 25-4' 12' 6'-8' 40001 15' 4'-0' 39505 22' 26'-8' 12" 6'-8' 39501 28' 4'-0' 3950# 22' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE 81 YIN. QTY. ANCHOR UK QTY. ANCROR FLOOR UDTH EA. END OF EA. END ON ANGLE 40� EA SECTION IN. MIN. a EA. SECTION uIN. e 20'-0* 2 50 N/A N/A 24'-0' 2 70' N/A N/A 254 3 42' N/A N/A P6'-8' N/A N/A N/A I N/A VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DOL HEAD ANCHOR ANGLE SPACING DBL HEAD ANCHOR ANGLE FLOOR EAVE WIDTH OVERHANG LOAD LOAD 20'-0' 12' 4'-0' 40001 20' N/A N/A N/A 24'-0' 12" 4'-0' 40DOI 24' N/A N/A N/A 254 12' 4'-0' 40001 26' N/A N/A N/A 26'-8' 12' 4'-0' 40001 27. ,,,,,,, , N/A N/A N/A NOTES: ENa1 `gft- PRLYAL•pot''/, DAPIA APPROVAL- S TE qF�F �/ 1. SEE AD-TD-0001 FOR ADDITIONAL REOUIREMENTS 2. SEE AD-TD-0031 FOR MAXIMUM PIER HEIGHT REOURED FOR THE LOADS TABULATED E1\E8703571 ABOVE: 3. 20 VADES -82" MAXIMUM I -BEAM SPACING ONLY. ✓ = 4. 4' MAXIMUM INSET TO ANCHOR HEADS (SEE AD-TD-0031). 6/Z�t( \�.�` — . _... ..- JAC O B S E N HOMES NOnca I'll"m 19FAW THESE waFlGTN)115 AND DRAWNGS ARE C.L.Y. DATE 6-13-95 REV. LETTER: TITLE:' ALT. SPACING TABLES AL MATTEENP Ac 'BSENOUFACAnF" AND °RA"'"G P.O. BOX 368 SAFETY HARBOR. FLORIDA 34695 LNG Ala MATERKS ARE PRONDED TO THE REaPENT rOR TEarc PJVM RD WST K DRAVANG M NUMBER: AD—TD-0030 PHONE.(813) 726-1138 WT CONiWTM AND SEW RN 0 42 ADDNDUM o 06°gS ALTERNATE. TIEEDOWN SYSTEM(S) aoo � TYPICAL CROSS SECTION SHOWING TIEDOWNS SEE NOTE 4 FOR MAXNW HDGHT FIGURE 5.0 4' . IVSE1 SEE FIGURE LI FOR RECOIDD MM THE—DOTIN METHOD . IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000. POUND ANCHORS TTW USING THIS TIE —WIN CONFIGURATION A STYLE CREST PRODUCTS YODEL 57SH (TYPE 21 AUGER ANCHOR T11i1 A DESIGN FDAD (FOR= LAID) RATDIG OF 4,D00 POUNDS AND AN ULMLATE LOAD RAT%% OF 6,000 POUNDS MUST BE USED. AH EQUIVH.ART ANCHOR MEETDIG THE ABOVE SPBCDICATIONS MADE By ANOTHER HANUFACTURER MAY BE USED IN IEU OF THE STYLE CREST PRODUCTS ANCHOR NOTES: THE ALTERNATE TIE -DOWN METHODS SHOWN ABOVE ARE ACCEPTABLE FOR USE IN I 'C' ALL WIND ZONES AND IN BOTH EXPOSURE AND EXPOSURE V. HOWEVER. BY 1. SEE AD-TD-0001 FOR ADDITIONAL REOUIREMENTS. INSTALLING THE FRAME TIE -DOWN STRAPS AT THE 'OUTBOARD' 1-SEAM THE MAX. 2 SEE OTHER DETAILS FOR BLOCIQN:. (PIER) WANiIIY AND OTHER REQUIREMENTS RE WDETAILS FOR THE COMMENDED METHODS FOR.. INSTALLING FRAME 11E-DOWNS. 3. FOR FIGURE 5.0 SEE ALTERNATE TE-DOWN SPACING TABLES (AD-ID-0030). :�������.��,,• ENG1NEfR,�pPROVMMI^ ' • �'i�� DAPIA APPROVAL 4. ZONE 2/EXPOSURE 'C': 3TC MAWUM HEIGHT 'D': YAX3PJM HEIGHT ZONE 2/EXPOSURE 27' ZONE 3/EXPOSURE 'C% 30' UkarJM HEIGHT j ,(�� �15 T��;r• ' ._ . " _ ZONE 3/ElQ'OSURE 'D': T105 APPJCA71ON IS NOT APPLICABLE. �2- N0� 0 S701r17T r A 2T'Il 4' .� �Il''�.,�s/OPT NOTICE: 1811111+ORAWN BY: L C.L.Y. DATE 6—t3-9s REV. IEi1TR JACOBSEN HOMES THESE SPEcnCA"iS AND DRAWu+cs DRAW'WG TITLE: FIG. 5.0 ORIONAL. PROPMETARY. AND CON110E111V1 uATOUIS OF JACOM MANIIFACT"G P.O. BOX 368 SAFETY. HARBOR. FLORIDA 34695 PC SUCH uATMAS AK PROW0 To THE, RECPOR FOR SUM F 000 AID WST BE DRAWING NUMBER AD—TD-0031 PHONE (513)726-1138 JUT COH Wnk AM SEOW FROM OREM �E ADDENDUM ALT. OFFSET UNIT TIE -DOWN SPACING TABLES 6O ZONE II&III/EP.C&D LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III U FLOOR D� YIN.OTY. EA. END EA SECTIONCiIOIO N ANCHOR AN YIN.. 6 YIN.OTY. E END OFANGLE EA SECTION ANCHOR uIN. B �t �O 20'-0' N/A N/A N/A N/A 24'-0' 2 42' 2 53' 25'-4' 1 2 1 45' 2 58' 26'-8' 1 2 1 48' 3 3.70 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DBL. HEAD LOAD ANCHOR ANGLE SPACING DBL. HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 20'-0" 12' N/A N/A N/A N/A N/A N/A 24'-0' 12' 4'-0' 40001 20'-30' 4'-0' 4000# 20'-30' 25-4' 12' 4'-0' 40001 20'-30' 4'-0' 1 4000# 20'-30' 26'-8' 12' 4'-0' 40001 20'-30' -4'-0' 1 40001 25'-30' LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III AIIL Y.O ANCHOR Y.O ANCHORANGLE FLOOR WIDTH D EA. END ON k E D EA. END OF EA gCnON YIN. B IN. EA SEC110N IN. YIN. B �QO 20'-0' N/A N/A N/A N/A 24'-0' 2 60' 3 45' 25'-4' 2 66' 3 48' 26'-8' 3 41' 3 52' VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III FLOOR WIDTH EAVE, OVERHANG SPACING DEN.. HEAD LOAD ANCHOR ANOF SPACING DBL HEAD ANCHOR ANGLE 264 12' N/A N/A N/A N/A N/A N/A 24'-0' 12' S-8' 40001 20'-30' 2'-8' 4000# 20'-30' 254 12' 4'-0'1 4000/ ZV-3T 3'-2' 4000# 1.51 30' 26'-8' 12' 4'-0' 4000# 25'-30' 3'-2' 4000# NOTES: NOTES: ENGINEER XffiomlTT1111,,, - DAPIA APPROVAL OFFSET SECTION NTH THE MARRIAGE LINE WALL EXIENDWG BEYOND THE ENOWALL of THE ADJACENT SEC110N MUST BE TIEDoowN AT THE MARRIAGE LINE�,• NE IN ACCORDANCE `��� C DO O,,APPROVED F '�G�S: BY MAIN THE TABLES ABOVE THE SIDEINALL SIDE AND THE ADJACENT SEC110N(S) ARE TO �0; ?� Q' h0 O .[� Z JUN 1 4 149§ BE nm Do1xT INACCORDANCE NTH TITS ALT. SPAaNc TABLES (AD-TD-0030). E 2. SEE AD-M-0001 FOR ADOInONAL REQUIREMENTS. � = i ��'' ` 3. SEE AD-TD-oam FOR YAIaMUM PIER HEIGHT REOIARED FOR THE LOADS TABTRATED �'�i, / `'L ABOVE �•(` ' F+ \,����• S JACOBSEN HOMES THESE SP OnCAMNS AWD•ORAANH6'�IK. tT`t`'',,,, C.L.Y. DATE. 5-30-95 V LETTER_* DRAINING TITLE ALT. SPACING TABLES P.O. eox 36e CRONAL. PRWKTARY. AND WdTpENNTWL MATERIALS of JACOBgN YANUFACTtFENG SAFETY HARBOR. FLORIDA 34695 Mir PHONE (813) 726-1138 MA7U01.5 AM PROYM TO THE RED NR Marx WOMS NO Ofil K PVT EONWTUE AND SEOV rR01 07HO i DRAINING NUMBER: AD- TD-0032 dd rrpiSN E1 ADDENDUM S ?pti1GA %Dvs P S ;1 0%�u OR5 RE4 ALTERNATE TIE -DOWN SYSTEM TYP. CROSS SECTION(S) SHOWING TIEDOWNS mu MOLE FIGURE 6.0 SEE FIGURE 11 FOR RECOMMENDED TIE -DOWN METHOD SEE NOTE 5 FOR MAXHIAA HDGHT [TA B OH AD-iD-M ME APPLY TD UIESE STA%" NUL -NOE SECIOS OF THE UIOT -SEE NOTE 1. AD-TD-O(M] IT. FLOOR STS101_ ANOIOR MOLE Tip. ANM MOLE FIGURE 6.1 SEE FIGURE 12 FOR MMMBNDED TIE -DOWN METHOD IMPORTANT NOTICE: THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THEN USING THIS M-DOWN CONFIGURATION A STYLE CREST PRODUCTS YODEL 57SH (TYPE 21 AUGER ANCHOR TO A DESIGN LOAD (TORN M LOAD) RATING OF 4.000 POUNDS AND AN ULTIMATE ROAD RATING OF 6.000 POUNDS MUST BE USED. AN EQUIYB ANT ANCHOR MEETING THE ABOVE SPECIFICATIONS MADE BY ANOTHER MANUFACTURER MAY BE USED IN IEEU OF THE STYLE CREST PRODUCTS ANCHOR NOTES: 1. SEE AD-TD-OD01 FOR ADDITIONAL REQUIREMENTS 2. SEE OTHER DETAILS FOR BLODONG (PIER) QUANTITY AND OTHER REOUIRENENTS 3. FOR FIGURE 6.0 SEE OFFSET UNIT TIE -DOWN SPACING TABLES (AD-TD-0020). 4. FOR FIGURE &I SEE NORMAL TIE -DOWN SPACING TABLES (AD-TD-DOiO). (ALSO SEE AD-ID-0020 AND AD-TD-0021) 5. IONE 2/EXPOSURE 'C': 32' MAXIMUM HEIGHT ZONE 2/EXPOSURE '0% 2C MAXIMUM HEIGHT ZONE 3/EXPOSURE 'C': 24' MAXIMUM HEIGHT ZONE 3/EXPOSURE V- 28' MAXIMUM HEIGHT THE ALTERNATE TIE -DOWN METHODS SHOVN ABOVE ARE ACCEPTABLE FOR USE N ALL WJDT ZONES AND N BOTH EXPOSURE 'C• AND.EXPOSURE V. HOYEVER. BY INSTALLING THE FRAk TIE -DOWN STRAPS AT THE 'OUTBOARD' 1-BEAM THE MAX HEIGHT OFT THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE RECOMMENDED METHODS FOR INS1ALM FRAME TIE -DOWNS •```��c1 C• D06 O?•G�STEq'�F'L �� •Q� No. Fo &NE8703571 APPROVAL' PROVED BY NIPINC5 LwI.�:PY-Wrnswaw4 JACOBSEN HOMESrTOIIc� %�; °A"�`"1 rijk DATE. REV. LETTER: Tt1Em SpEOiH'ATNXNS Aid MANtIf.S ARE 18111111% C.L.Y. 5-30-95 MATERIALS pRF ACT RT, AND CCNI>DEN m DRAWING TITLE: HE P.O. BOX FLORIDA � MA1D KS AM OW TO rtlEG FIG. 6.0 do 6.1 SAFETY HARBOR 726-11 34695 . RLOEM FOR 9W C RFC ma MM FE DRAWING NUMBER: PHONE (611) 726-1138 IIPT CIKWR4 kO SEO ET MOM OHM AD—TD-0033 ADDENDUM �lO Ott ALTERNATE TIE —DOWN SPACING TABLES ZONE 1I & III/EYP. C & D LONGITUDINAL TIE —DOWN SPACING TABLE (+� MIN. WND ZONE II WIND ZONE III 10,11. OTY. ANOIDR UK OTr. ANCHOR �J FLOOR MOTH EA OF ANGLE EA. END ANGLE EA SECTION YIN. B IO EA SECTION MIN. B 12'-0' 2 43' 2 55' 13'-4' 2 50' 2 68' 10 VERTICAL TIE —DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPAONG DBL. HEAD LOAD ANCHOR ANGLE SPACING WL HEAD LOAD A 00 ANGLE FLOOR OTH EAVE OVERHANG 12'-0' 6' 4'-0' 37501 20' 4'-0' 39001 22' 13'-4° 1 6' 1 5-4' 313501 25' 1 5-4' 39601 30' THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III Y. ANCHOR Y.O ANCHOR FLOOR WIDTH A. END U END Cf EA SECTION ANGLE HRH. A EA. END OF k DID EA SECTHON ANGLE MRL B O 12'-0' 2 64' 3 47' 12'-0' 3 37' 4 33' 13'-4' 3 42' 3 55' 13'-4' 4 30' 4 38' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. WIND ZONE II WIND ZONE III SPACING DEL FAD LOAD ANCHOR ANGLE SPACING DEL HEAD LOAD ANCHOR ANGLE FLOOR WIDTH EAVE OVERHANG 12'-0' 6' 4'-0' 39501 25' 2'-8' 39301 20' 13'-4' 6° 4'-0' 39601 25' 1 2'-8' 40001 30' THIS ALTERNATE APPLICATION REQUIRES,,,,4,,p00 POUND ANCHORS NOTES ENp`NE�1}%` RI�L O� '/���4 DAPIA APPROVAL 1. SEE AD-M-OD01 FOR ADDInONAL REOLIMENTS �Q?�l�C��STEq ' O�Z��% APPROVED EW 2. SEE AD-ID-OOM FOR NAOM PIER HEIGHTS REOWRED FOR M LOADS iABUTAIED ADOVE e No. _ - ENE9703571 1 5 rfl 3. MAX EAVE OVERIWIG REFERS 10 OVERHANG AT SIDEWALL NOT FRONT OR FOR7N +%�Q�'•.. I 4. ABOVE TABLES APPLY TO 160' FLOOR OR 144' FLOOR WIDTHS WITH 95 1/2' / 6 q '���� ND.. N• •'(�� v ucr a�ou®�a[ � 1-BEAM SPACING• 96' MAXIMUM SIDEWALL HEIGHT AND 6- MAXIMUM SIDE OVERHANG (6' OVERHANG MAX EACH SIDE OF LMR) �' '�� ' `�` JACOBSEN HOMES NOMCE . '11:11 msE SPEOF1 DONS W DR YMM mtvn C.L.Y. DAIS 5=30-95 REV. LETTER DRAWING TITLE. ALT. SPACING TABLES P.O. BOX 368 ONaCMAL PROPWCURY. AND CONRIDf M MATERIALS OF j COM YMIUFACRANG A „ SAFETY HARBOR. FLORIDA 34695 PHONE (813) 726-1138 HC SUCH YATERULS ARE PROYM TO ENE KCRE NT FCR SPECIIC PJMZ NO KW 81 PvT cDN mTR AIO SENRET TROY oTan DRAWING NUMBER AD-TD-0040 46 ��p�pgS �000� ad"ADDENDUM ALTERNATE TYPICAL CROSS SECTION SHOWING TIEDOWNS TIE —DOWN SYSTEM ANGLE ANGLE FIGURE 7.0 SEE FIGURE L3 FOR RECOMMENDED TIE-DOTH METHOD IMPORTANT NOTICE: SEE NOTE 1 FOR MA70NM HOGHT THIS ALTERNATE APPLICATION REQUIRES 4,000 POUND ANCHORS THEN USING THIS TIE-DOTN CONFIGURATION A STYLE CREST PRODUCTS YODEL 57SH (TYPE 2). AUGER ANCHOR TIN A DESIGN LOAD (TOME IOAD) RATING OF 4,000 POUNDS AND AN ULML47E IDAD RATING OF 8,000 POUNDS MUST BE USED. AN EQUIVIANT ANCHOR MEETING THE ABOVE SPECIFICATIONS MADE BY . ANOTHER MANUFACTURER MAY BE USED IN LZU OF THE STYLE CREST PRODUCTS ANCIIOR. NOTES: 1. SEE AD-10-OD01 FOR ADDITIONAL REQUIREMENTS 2. SEE OTHER DETAILS FOR BLOCIONG (PIER) QUANTITY AND OTHER REOUIREMENTS. 3. FOR FIGURE 7.0 SEE ALTERNATE IE-DONN SPACING TABLES (AD-ID-0035). 1. ZONE 2/EXPOSURE 'C': 38' MAXIMUM HEIGHT ZONE 2/EXPOSURE 'D': 28' MAXIMUM HEIGHT ZONE 3/EXPOSURE 'C': 28" MAXIMUM MIGHT ZONE 3/EXPOSURE V. 28" MAXIMUM HEIGHT 5. SEE AD-7D-0035 FOR ADDITIONAL NOTES JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 xprd PHONE (813) 726-1138 THE ALTERNATE TIE-DOYN METHODS SHOVM ABOVE ARE ACCEPTABLE FOR USE IN ALL WIND ZONES AND IN BOTH EXPOSURE 'C' AND EXPOSURE 'D', HOMIEVER, BY INSTALLING THE FRAME ME-DOMN STRAPS AT THE 'OU7B0AFV I, -BEAM THE MAX HEIGHT OFF THE GROUND IS GREATLY REDUCED. SEE OTHER DETAILS FOR THE RECOMMENDED METHODS FOR INSTALLING FRAME TIE-DOMMS. �O? : ►S TE9�F G Q No. ;FNEMa� NOTICE;" "'I4�ry, UK %W. MSE SPEC11 TOMS AND DRATOM ARE C.L.Y pIDWM. PROPRETARY, AND Llmrm IIYIL DRAWING TRLE MATTRIAS OF JACOM MANUFACTIM4 NL SIGN MATERIALS ARE PRO = TO 111E KOHN FOR 9'Ef>F1C P1LiP m ND Lust 1E DRAWING NUMBER IE" CDNFFJLIRIAL AND SECRET FHCM orrm APPROVED BY IN 14 3SA INC cov �.�w,ruwmiT.oNw RiV 5-30-95 . LETTO FIG. 7.0 A AO-TD-0041 47 ADDENDUM MISC.. TIE -DOWN PROTECTION OF STRAP IS PROVIDED AT UPPER CORNERS BY FIRST WRAP OF STRAP. SEE DETAIL 'B' SEE DETAIL DETAIL 'A' IUCKLE WITH 3150j Y MINIMUM (DESIGN LOAD) DETAIL 1 B' -BEAM LL DOWN TIGHT TO DUND ANCHOR INSTALL RADIUS CLIP (SEE AD-TD-0200) OR IF SIMILAR DEVICE TO PROTECT STRAP AT ALL SHARP CORNERS. �C DETAIL T C' THIS TYPE OF PROTECTION MAY BE USED FOR T;CT,3( N,,AT'LONGITUDINAL TIE CONNECTIONS ALSO. X., ST/(�,.c, NOTES: Et -I- '% DAPIA APPROVAL: 1. SHOWN ABOVE IS ONLY ONE METHOD OF STRAP ATTACHMENT = 910334 ? APPROVED BY AT BEAM -OTHER METHODS THAT ARE CERTIFIED TO MEET o00 •: �; _00 THE REQUIRED DESIGN LOAD OF 3150# MAY BE USED. ON rl 2. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS '° '• STATE OF WHERE THE ANCHORING SYSTEM REQUIRES THE USE %0O• / P•' �': OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CUP). t.UWUH1CTUiH0A1F SjON 'FMkL � � ` � /� 2 taNAro ME D AND rT R D OTHERS NOV 2 4 1998 NOTICE DRAYM 8Y.' DATE REV. LETTER: JACOBSEN HOMES THESE SPEaFlCATIONS AND DRAWNCS ARE M.T. 11-18-98 B aNC MONAL, PROPR[TARY. AND CONFOENnAL DRAMNG TITLE:MISC. TlE-DOWNP.O. BOX 368 MATEFOALS OF JACOBSEN MANUFACTUNNG SUCH YATDMAIS ARE PROVOO TO TIE SAFETY HARBOR, FLORIDA 34695 RCO MT FOR SPECFIC PURPOSES AND MI BE DRAYANG NUMBER: PHONE (813) 726-1138 KEPT CO FMTUL MD SECRET FROM 01 ERS- AD-TD-0050 140 ADDENDUM NORMAL TIE —DOWN SPACING TABLES ZONE II & III/EXP. C & D j LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE II WIND ZONE III FLOOR UK DID CHxt arT. ANA. A EA OF AHGIE EA DO OO m WDTH F O EA. SECTION UK EA. SECTION YDLUi. 30'4 3 40 3 25 VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. FLOOR WIDTH MAX. EAVE OVERHANG WIND ZONE u . WIND ZONE III sPAGHc D3L 1&0 LOAD tiyataR ME SPAL�Nc DBL LEAD LOAD ANG10ti ANGLE 30'-8' 6' 6.4 31501 41-46 5'-5' 31501 44-49 v LONGITUDINAL TIE —DOWN SPACING TABLE MIN. FLOOR WIDTH WIND ZONE d WIND ZONE ql ►E OTT. Ell END OF Eel sEcnav ANGLER VOLma YIN. QTY. EA END OF Ell sEcnDrl AH01 ANGLE uw. e 3T-8' 4 42 4 25 VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX WIND ZONE H WIND ZONE 10 FLOOR EAVE SPAONG D' MEAD Del. HEAD WIDTH OVERHANG LOAD ANGLER ANC SP�wc LOAD ANOIER� 30'-8- 6' 4'-6' 3150E 46-50 4'-0" 3150/ 49-52 VANDZONE DI (110 MPH) 20 PSF ROOF 10 PSF D.L. RERCALCS. NOTES: tHI It ADVAC' / 14 1p, i�' i��i'' DAPIA APPROVA{ � o nMfi>� O S ���` C'r�•' &STFR ' . 1. SEE FULL ADDENDUM FOR AODIRONAI REWIREt1EFITs No. APPROVED BY 2. SEE AD-7D-0071 FOR MAXIMUM PIER HEIGHTS REWIRED FOR THE LOADS .`�o'• 910334 TABULATED ABOVE Cz TAT E INC. . Cam•' O .Z* �'.,. nciluir,,.Kecluuow� �.` � Oyanectc�tuovrttrswamt LEM JACOBSEN HOMES 7KSESE011cAN0fl° AAMTICLY LxAwMARE BT` M.T. °" 2-8-99 ' OR*21 11 IErA". AND CCKDERIIAL DRAYANG TITLE: P.O. BOX 368 Y.TE4M CIP .NCOBSEN YAMUPACTURWO NORM. SPACING TABLES „ W_ M MAIM S AM PROVM 10 SAFETY HARBOR. FLORIDA 34695 R[CP T m 9'EOnC PAVM Aro Z pE DRANING NUMBER: PHONE (727) 726-1138 I¢Pt C06=114 AM SE00 RM onus AD—TO-0070 L° 49 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE —DOWN SPACINGS rµ rttt w-lu-wlu IML nX AU-IU-WW IAIlL Half AU-N-WN MULL nX AINIINWIO IABIE PER AD-M-WO TAKE MAX FIGURE 10.0 SEE FIGURE 20 FDR ALTERNATE M-DOWN WROD TYPICAL CROSS SECTION I I III SHOWING TIEDOWNS �oaR SYM-7 Tr. HIIOSS-YE1�It 3 SEE NOTE 5 FOR N MM AWL man ma FIGURE W.I SEE FIGURE 50 FOR ACt1001AT8 711-DOWN VMD E11111IFA..c. will it, o[•- 9/. WNNDZONE III (110 MPH) 20 PSF ROOF 10 PSF D.L NOTES: E.... R•��''�. 1 v�'; 7cv �% DAPIA APPROVAL. 1. SEE AD-TD-0070 fOR SPAM TABLES. : �Q�' NO. �� .•• APPROVED BY 2 SEE AD-7D-0070 FOR OUMIITY OF LONGIMAL TIE -DOWN STRAPS REOURED. 910334 3. SEE OTHER DETAILS FOR BLOWK (PER) WANITY AND OTHER REOUREIIENTS. 4. SEE RILL ADDENDUM FOR ADDII NAL REOUREIIFNTS S. ZONE 2/EIPOSIX V. Ss' MAx4IUM HE10HT :• STATE OF r W *. Q '•. / IN 14 INC. '�i� . ~ D' �P..�`�C p \ ZONE 2/EXI'OSURE V- Mf MAXIMUM HEIGHT . •� `-`� '�i� .•1' IEtl�na uf► omm suls" ZONE 3/ElIP IM V. W MAXIMUM HEIGHT S' � fQl lglCfA71MOS�FE7T ZONE 3/0POSIRE V.- 40' MAXIMUM HEIGHTfill >��a c JACOBSEN HOMES NOTTCzt 117- wm SPEfTICA1N m AND DRA Nis ARE DRA : M.T. DATE: 3-1-99 REV. LETTER MGM, PROPP[TM. AND COIFUENTIAL M 1MALs OF ARC0�N MAKFA""`� DRAWING TITLE: FIGURES 10.0 AND 10.1 �r P.O. Box ass Nf: WM MATERAIS ARE PROWED 10 7K SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 FORM FOR SPECWIG P WNSES AND WST BE WT CKW ML AND =FFT FROM OTNETIS DRAWNG NU118ER: AD-TD-0071 50 ADDENDUM. gas 15;6 0 3 NORMAL TIE -DOWN SPACING TABLES ZONE II & III/EXP. C & D 1 i LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE I WIND ZONE HI FLOOR LIIL OTf ANGLER N]LL OT1 ANOi 10 WIDTH EA. END OF Ell SECTION ANGLE WIDE 6 EA. Ell SECTION E K . ImI.N 6 15-4- 3 45 3 35 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX HIND ZONE II WIND ZONE III FLOOR WIDTH EAVE OVERHANG SPACING LOAD WE moo E SPACING LOAD MOOR ANGLE 154 6' EACH SIDE 6'-10' 31501 407-46 5-6' 31501 42-47 LONGITUDINAL TIE -DOWN SPACING TABLE MIN. WIND ZONE II HIND ZONE III O a FLOOR WIDTH Ya. Ott Ell END OF EA. SECTION ANGLER ANGLE UK B YDL CITY. EA. DO OF Ell SECTION ANCHOR ANGLE YIN. B 15-4' 3 30 4 35 VERTICAL TIE -DOWN / FRAME TIE -DOWN SPACING TABLE MIN. MAX WIND ZONE 11 HIND ZONE III FLOOR WIDTH EAVE OVERHANG SPACING DEIL HEAD L0 ANm ANGLE SPACING DB OAAD AIIm WE 15-4' 6' EACH SIDE 4'-6' 3150 f 42-50 4'-0' 31501 44-50 VANCIZONE NI (110 MPH) 20 PSF ROOF 10 PSF D.L. REF. CALLS. w4 - 2. G(- 172 u„rrrrrf NOTES: I. SEE FULL ADDENDUM FOR ADDITIONAL REOUIREMENTS. 2. SEE AD-7D-0073 FOR MAXIMUM PIER HEIGHTS REQUIRED FOR THE LOADS TABULATED ABOVE 1. MAX SAVE OVERHANG REFERS TO OVERHANG AT SIDEWALL NOT FRONT OR REAR. 4. ABOVE TABLES APPLY TO 184• FLOOR WIDTHS WITH 95 1/2• I -BEAM SPACING, 96' MAXIMUM SIDEWALL HEIGHT AND 6 MAVUUM SIDE OVERHANG (6. OVERHANG MAX EACH SIDE OF UNIT). G\No.R�o '; Q 910334 we -do w.; -o • STATE OF L '��'•, P : �� S DAM APPROVAL•MM APPROVED BY INC. Iv rb „ JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (727) 726-1138 NOTI • fILI THESE SPEdnCAPONSANDORAVNGSARE ORWAL PRDPRIEIART. AND COMNDA WERIALS OF 44COBSEN uAwAcTURorD DC SUCH uATEMALS ARE PROMKO To TIK RCCMI fOR SPECTIC PLW=b Amu uUif RE ►iPT Covn(XNTU.L AND SEatEI rRDu OTNF)IS I! BY: M.T. DATE 2-8-99 REV. LETTEIC . DRAWING nllE NORM. SPACING TABLES DRAWING NUMBER: AO—TO-0072 51 ADDENDUM TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION SHOWING TIE -DOWN SPACINGS MAX PER LID-1D-0012 TABLE I m 0-TD-0012 TAaE PER AD-TD-0012 TABLE PER AD-TD-0012 TAKE IS AD-TD-0012 TARE MAX TYPICAL CROSS SECTION SHOWING -TIEDOWNS FIGURE 10.2 SEE FIGURE ZO FOR ALTERNATE 719-DOVN VMD s SEE NOTE 5 FOR MA)3WUM HXHT N F A~FIGURE 10.3 VYINDZONE III OF HOME (TiP.) 110 MPH SEE FIGURE 7.0 FOR ALTERNATE 111-DOWN 1MD 20 PSF ROOF 10 PSF D.L REF. CALCS 92 • l6 NOTES: 1. SEE AD-TD-0071 FOR SPAM TABLES MID NOTES. Z SEE AD-TO-0072 FOR OUAMTY OF LONQTUDI L X-DOWN STRAPS REOURED. 3. SEE OTHER DETARS FOR BLOCKING (PER) QUANTITY AND OTHER REOUIREMENTS. 4. SEE FULL AODEC•DUM FOR ADDITIONAL REOAIIREMENTS. 5. ZONE 2/DPO511RE V: 56' MA)QMTM HEIGITT ZONE 2/DFOR E V. 56' MAAMAA HEIGHT ZONE 3/DEOSLK V. 56' MAAMUM HEIGHT ZONE 3/DPO9URE V.- 56' MA)OMAI HEIGHT No. o 910334 -q STATE OF i DAPIA APPROVED BY I 000r N 14 INC. iEottia twaActu®ttaE tTattnocnataotwu►twwa I 4 NO` M.T. NOTICE JACOBSEN HOMES v�' " 'bITAIIIf-gY: DATE 3-1-99 REV.TKSE SPEanCATIONS AM WA ARE LETTIR ORIMPL PROMUARY. AND 0@iT0EE11nAL DRAWING TITLE: NORP.O. BOX 368 MAIMALS OF 4 COagN MANUFACMWG MURES 10.2 AND 10.3 WC 9" MATE16ALS ARE PROW" TO THE SAFETY HARBOR, FLORIDA 34695 RECFO f FOR 9PEff1C PUtPOSES AM UM BE DRAWING NUMBER PHONE (727) 726-1138 *PT CONFMGM& Afro sEma nmu umm AD-TD-0073 52 ADDENDUM �s OFFSET UNIT TIE —DOWN SPACING TABLES ZONE. II & III/EXP. C & D. LONGITUDINAL TIE —DOWN SPACING TABLE (+1 MIN. WIND ZONE 0 WIND ZONE III W oTr. ANOICR WL OR ulm V FLOOR �G VON EA EID ff ff NIGLE EA sEcna� R. MR. a FA SEC EA sEcnoN iw. e 12'-0' 3 47' 3 61' 13'-4' 2 54' 3 All' 15'-4' 2 54' 3 41' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. W ND ZONE I WIND ZONE M sP Lm ANOfOR ANGLE SPACING � ANCHOR ANGLE MOTHOVERHANG EAVE 12'-0' 12' 5-0' 31501 40' 4'-0' 3150# 394 1S-4® 12' 5'-0' 31501 41' 4'-o' 30001 40' 15-4' 12' 5'-0' 31501 43' 4'-0' 3000/ 42' LONGITUDINAL TIE —DOWN SPACING TABLE MIN. WIND ZONE I WIND ZONE NI M+ on ANCHOR A. ATY. ANCHOR FLOOR v Y�OTH FA END OF ANGIE EA END OF . ANGLE ANGLE O� r� EA SEcu ILL 9 Ell SECIION WL 9 12'-0' 4 45' 4 60' 114 3 45' 3 60' 3 _T 45' 3 T 60' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN. MAX. MIND ZONE 1 WIND ZONE III sPAdNG ML NERD tDAo ANDNOR ANaF WHEAD tDAD AraRoa " FLOOR WIDTH EAVE OVERHANG 12'-0' 12' 4'-0' M501 40' 3'-0' 3000 f 38' 13'-4' 12' 4'-0' 30BI 41' 3'-0' 3000/, 31r 15-4' 12' 4'-0' 3Of 43' S-0' 30001 41' NOTES: ic615 C4LG5, C- i& - 1.6 ,a!- �6.1L ENGINEER APPj"M§ N ;.,, REF. CALCS,- .++ D. D 17,4 S, 1. OFFSET sEC110N MATH THE MARRIAGE LIE WALL EXIFNDNG NEVOFO THE I]OrYA11 aF .• IF . • 1HE ADJACENT SE ION NJIIST BE TIED DOWN AT THE MARRIAGE LYE IN ACCORDANCE . ' 4 �F'.y D G�1'L ; ' �� BY At1N THE TABLES ABD�E. THE SIDEWALL SIDE AND 1}E ADJACENT SEMKIKS) ARE TO � BE TED DONN NN ACCORDANCE WIN 1FE NORMAL, SPAGIRG TOM (SEE AD-TD-0010 • ' JUN FOR 12'-0' R 13'-4' WDES, AND AD-1D-0070 FOR 15-4' AIDES): 2 SEE AD-1D-0001 FOR ADDITIONAL RQIAREIE]RTS • # STA , S J I SEE AD-1D-0081 FOR MA)OMUII PER HEMT REOURED FOR THE LOADS TABU AIED . r Q OR1flP:•• 1 v INC... ' AB •; (��'�, LMANUFAMFOHNEWhims JACOBSEN HOMES >bvnm �'� + : at ����°`IL 6-8-04 MY. L� ,. P.O. aox ass . GIGNAl. PRaPIMMY, M ORAAIdG 11M WREMIR S W JIICGBg?I YIWIF W, 50 MN,� „� Ta OFFSET SPACING TABLES SAFETY HARBOR, FLORIDA 34695 PHONE (727) 728-1138 ItFWIN FGt WM FAWW0O DRAIMNG NIlfM AD-�- ITT ootfmlm me SEAT e° ,63 ADDENDUM OFFSET UNIT TIE -DOWN SYSTEM TYPICAL SIDE ELEVATION (W/ OFFSET SECTION) SHOWNG TIE -DOWN SPACINGS i FIGURE 11.0 SO FiCW 4.0 FOR 9nRl TK 'DB-101N 1D?T80D 5 SECTION(S) TIEDOWNS O& 5 FOR Nr INaaMT [TgoN ASIo-IaLN"I� OF K WT -NE NOW % AD-M-GOKI TIP. FLOOR SYSIDI--7 r F— ANWQN MQE Sly TV. ams-mom �f svc4 19.o)^ FIGURE 11.2 r? 61 M ALMU1 W-DDE MOOD NOTES. r ��'T�{n ►j U091A ,r wvn" I. SEE AD-TD-0080 FOR SPAM TARES (OFFSEF SECDGN OK4 `z; ~ * �} r S : F f O f d� PPROVED BY 4. SEE AD-W-0080 FOR QUANITY OF LOfKiiT UAL TIE-DOW SIRAPS REOU U. (OFFSET SECTION ONLY) 0.00454 JUN 3 SEE OTHER DUALS FOR &WONG (PER) QUANTITY AM OM REQIARE MTS 4. SEE AD-1D-0001 FOR AODI110NA REQUfRE11FNT5. 04 J J1� : im INC. 5 ZONE 2/bV09lIRE 'Cs 48' MAXs1UY FEICNT ' •A ' P • •.'• 4 a44 Ff ERAL NUFAL'TURED HOME ZONE2/EXPO6URE b': 40• MAXIRMY Ff1C,FIT-38' FOR 12'-0' WIDE UMTS :� t��••• fi. {�lc� (�� �+CC qSIRMTK)N AND SAFEFYSTANDARDS ZONE E 'C: 46MAXIMUM HMHT b: 0' MOIFETTZOE a' R,/S� ' •'( `�3. �� _ �En rr mnca •rr ,A : ARPtlMM T. DAE g_8-04 REV. LETTER JACOBSEN HOMES DM SKCFMT ns No DUVM NiE n ORM4 PROPIa<T MI. W I:a R& DRAWNG TIRE: I"\ P.O. eox 36a ""� OF rA�M YA►ANFACPAW FIG. 11.0, 11.1 & 11.2 NC WM MAINKS ARE FROYM 10 1NE SAf W HAROM FLORIDA 34695 NEW FOR SPEGFIO P0(P09i5 AM Wff BE DRAVC PNWa: PHONE (727) 726-1138 NET awunoL n sEnIET mm olm AD-TD-0081 54 99 Tmo"mIMNanivuNUM]143M OCLL-9L[ UU) 3NONd 7138MAN 9N6MVMo 11 3e um OW S3MdMW YMM M JAGW sfign Ya1Mo1! 'MOBMVM A13 07l '91j �15 ]m 01 4XIMAN 3UV SWVMVfl W3 M 'Si 89C X08 '0'd 31Lu 9NlMraa WOK 00 „OW 'AANYLI iMN*eo 10-6-9 -a-a 3vr s�V80 OW SNCLLVOWNS 3s3KL SSNO14 Nsseoovr :M U31 'A3M 31Ya .A8 NMYMO 30L10N $ yk'il�:`.'1Sai3i"S0:�;7tl�IL;i1L+1S ''�'� I ` ► 74 .IVAO34A" Vid uOILLO�S - Ind '497ilo. gas 31ENL OIOO-M-Or MO %VM 318tL OL00-a1-a Mad i � POm i VEE0T6 'o a: ''�•,._ ]Its 'l _..+•+� . 90d ZJT GNV I'IT MEDIA 99S 'SLN3rG8lM38 1VNOLLIOOV MO! 1000-a1-Or 33S 'r S1N3N31OI103M M3NL0 ON/ A11Lwno ()j3W) 9141=18 MOB S11VL3o MO 33S T WN0 NOLLJ3S 13SIM) '03MILIO3M SdYMLS NM00-311 1YIoNLDN01 d0 A11Wn0 MO! 09W-OL-OV 33S Z UINO N01133S 13SAP) S31VI 9NOUS MO! 0800-01-OV 33S '1 •S�Zb1Z Rl MOIl7 318+t1 OL00-OL-OV 1A ML 0100-41-0 M) 11OYL 0100-01-011 Mad 3>all CLOD-OL-& Iad w" 1mdo Mid IVO J 77 _ ................... liG=rl S9NOM NMOO-311 ONIMOHS (NO1133S 13SJL O /M) NOW313 301S -NOW 1 WRIUS UO.G —9I1 ZING- IBM H i N8911V MENU ADDENDUM 108" HIGH SIDEWALL TIE —DOWN SPA ING TABLES 1� 0 ZONE II & III/EXP. C & LONGIT im TIE —DOWN SPACING TABLE �+t MIN. W ND ZONE I WIND ZONE N r FLOOR 1K Off. Maur rx on moo �j WIDTH . W ff mu FA 00 OF ANO.f SED1101 WL A u Secm WL A 26'-e 3 42' 3 53' 52 4 45' VERTICAL TIE —DOWN / FRAME TIE —DOWN 1 SPACING TABLE MIN. MAX. WIND ZONE I WIND ZONE I WWIDTTH OVEOR RHANG SPAM m WA Lm Afl0O ANQE SPAM °�� ANi80R ANCLE 26'-8- 6' 6'-8' 31501 40 -50' 6-46 31501. 40'-50' 30'-81 6' 6'-8' 31501 40 -50' 11 S-4' 3154 40 -50' oo LONGITUbINAL TIE —DOWN SPACING TABLE MIN.. WW ZONE I WIND ZONE II FLOOR rO�Tyi AN= ME WL QTr. EA. EM aF AN= AM WIDTH eci m MIL Y EA. SEC7101 WL 8 26'-Ir 4 41' 4 5T 30'-80 4 51' 4 70' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE MIN MAIL WIND ZONE I WIND ZONE III WW TH EAW OVERHANG SPA= L" A11010i A w SPAM ML NEW LOW M ON MGUE 26'-8' 6' 5'-4- 31501 40'-50' 4'4 31501 40'-4Y 30'-8' 1 6 5-4' 3150/ 1 40'-50' 4'-O' 31501 40 -45' VANOZONE N1 (110 MPH) 20 PSF ROOF 10 PSF D.L. REF. CALMNo@c11 NOTES: EN , �L: �, �� wz1a=l c �,•' DAMA MfMAL: I. SEE Rill AEENI" FM AD1 lmAL REQwF"ENTSS, GS' � c�` :Y �a = APPROVED BY ' ' No. 0045484 u 2 SEE AD-M-M FOR MAIM M IE1M REOWn FOR TFE LOADS TAEIIA.ATED ABOVE .t INC • •••' .... FEDERAL MANUFACTURED HOME '.,JrTF� ED •; ` CONSTRUCTION AND SAFEPf STANDARDS '4ft. ant lit JUL 27 ?00$ JACOBSEN HOMES NOS nEg �uTiaRs Aw owA.as ME oRArw'i BY: M.T. DATE- REV.REv. LETTER DRAWNC nTLE 108' HIGH SIDEWALL SPAaNG TABLES P.O. BOX 368 ONO+K• MWKTM I Am OmfUNM 1A7 MS OF ,FwaoM K44WACROO W_ WW WAMI S ME FROYM A IW SAFETY PHHONEE (72277) n6-pi138�95 WCoiFMIM NO � FF= DRAwNc MINeE& AD—TD-0083 56 ADDENDUM TYPICAL SIDE ELEVATION SHOWING TIE —DOWN SPACINGS TIE -DOWN SYSTEM FIGURE 10.0 TYPICAL CROSS SECTION SHOWING MOWNs I I np• ROOK SM-7 TV. aIREsPDI YuMm mm r ANafidt mumm NlaE—T �e ff FIGURE 10.1 (io MPH) 20 PSF ROOF 10 PSF DA_ 5v- l$,a(- I?f, z NOTES% 0 • • DA N APPROVAL: 1. SEE AD-ID-M FOR SPXK TAeIEs •'-YIF , . �: G�� � APPROVED BY z SEE AD-TD-0083 FOR aumTr OF LOIM7RIDIAL w-am STRAPS REQUAED. . •• 1 SEE OTHER DErAIS FOR BLODMG (PO) QUANIITY NO OTHER REQUit OMUK i 4 SEE Fill ADDS M FOR ADpTH)NAL RECOMIETITS S ZONE V: Tile QQ ; 2/DPOSLK 36• YA)QYUY HEIGHT ZONE 2/baIr� b': Zr YA>OM1Y FFT(i1T l� "�� •• •` Q' �� INC. 1 ZONE 3/EXPOSURE W. 3r YAMM HEIGHT ZONE 3/EXPOSURE b': 32' YAlQAN1Y HEIGHT �� C/�'-•.aRP►• •� ��® ♦♦ aT" �� FEDERAL. MANUFACTUREDHOP.tE COMSTRIICTIONAND SAFEfYSWANS 6. ALL SPEdFICAlIg1S ARE BASED ON 20' ROOF A11(IE ma - ♦/T'�Qt� ,�� 11 -.)tit t 7 20 JACOBSEN HOMES NO=: RM 9'ECMI M6 NO MAIM AM " �� : M.L 0A1E 07-20-04 ter. `E"M DRUM 1RE-d TIGURES 10.0 AND 10.1 P.O. Box 36a ==Pd. FMMUMY. NO aoNUMIX MAMAS CF AWOM "AMJFAC1J°'D SAFETY HARBOR. FLORIDA 34693 IIG 90 YIIMMS NE F7i01FDFFD A 1iE FIST FTR 9M NtP= MO MW E DRAB MAIM PHONE (727) 726-113D IOPT oQ�lo M = SM FNN OM �—�—�4 57 ADDENDUM 108" HIGH SIDEWALL TIE -DOWN SPACING TABLES ZONE H & III/ EXP_ C & D 10 LONGITUDINAL TIE -DOWN SPACING TABLE t (�' MK WIND ZONE 1 WIND ZONE IB V FLOOR mi an wraaR ux OR wlan 1YIDTH 06 � EA ETD a• MOLE Ek SEC001 TBN. / Ell SECROI IRL 6 �O 2S-4' 2 58' 3 43' 62' 3 45' — mTICAI. TIE DOWN FRAME _ TIE—DOWWN SPACING- TABLE NIL MAX - WHO ZONE 1 WIND ZONE M WIDTTH OVERHANG EAVE �i10K ML WA LN ANCHOR ANOIE SPA?!C °�� Maim ACE 6'. 6'-8' 31501 49' S'-4" mot 45' 24'-0' 6' 6'-8' . 31501 49, 5=4' 3150 45' LONGITUDINAL TIE —DOWN SPACING TABLE l MIN. WIND ZONE 1 IND ZONE W FLOOR W Ott Al m loll oR MDU Ell ll END Crm u EA DO a ACE O r� EA SECTION MR 0 EA SECIM YYI. i 13'-4' 3 48' 4 43' �j 24'4' 3 Sr 4 •45' VERTICAL TIE —DOWN / FRAME TIE —DOWN SPACING TABLE SIN_ MAX WIND ZONE 1 WIND ZONE 19 WOOVONG SPA= LOAD AI1M ANQE SPACMI: AN01CR MCLE LOAD 214' 6' 5-4' 31 4r 4'-0' 31m 43' 24W 6' 5-4' 31501 4T 4'4' 3150 43' 108' WAX 9DEWALL HEIGHT MOZONE II/111 (110 MPH) 20 PSF ROOF 10 PSF D.L W. CALM NOTES: :-• DAM APMMAL 1. SEE ApOETWUII FOR ACN110NAL REW6IEHD:iS F1ILL ��` S;K}F'�'9T'•,'✓ '4 : � APPROVED BY J Z SEE AD-10-M FOR YANAIM PIER NEIGM RE0J= FOR THE LO ec-13,2006 IN7fi TA8IA.ATEO ABOYL. s ` ' NCH ' : A`l I Y' ' CONSDUCFOX AN WM STAMMnS O H10 ,lam JACOBSEN HOMES IM AW 2Q71 11E6F�fDR NOT' L' AIMMAR� 81: R.R. DATE 11-28-06. REV IETTEfi P.a Box 368 � QV=AL MOVIEM AM tarsto tt y't10""� OF i61�x ""�`"�"""n W-amwmu�t AI[ nv� To in DRATANG A1lE 108' HIGH SIDE:WALL SPAaNG TASO SAFETY :ARBOR, FLORIDA 34695 vr,oNE 7z6-nab Jt� FM 9RIIIC hw= N O N= K WT mmwcuLno swu ma aeon DRAMNG M WER: AO-M-0085 - 58 TYPICAL SUE EIEVAION . SIiOWING T(-DOWN SPACINGS. TYPICAL CROSS SECTION • SHOWING IEDOYMS ADDENDUM TIE -DOWN SYSTEM TV. ILODI FIGURE 10.0• TV. PF AN a A11OlE Di APPROVED SFABIORR SEF AWO WAO msum Im = at 9PFF WICPL asT511 FIGURE 10.1 REF. CALLS. NOTES: `• ,....... 1 1. SEE AD-10-M FOR SPAOING TABLES Z SEE AD-FO-M FOR Q ANM OF LDN ITWAL K-DOR11 STRAPS REOUKD. 3. SEE 010 WAS FOR BLOOM (PER) DUAMRTT AND OW REOUBiE OM • V �: 4. SEE IM ACUMM RX ADDOIONAL REQAREUDIM j S ZONE 2/01POlk 1C W MAWN HWff ZONE 2/EIroK •D': 2r MAmN 1Ew ZONE J/D�OAIRE •C: 41• VAMN NEVff • S ZONE'3/kx►W1ttE V. AS' MA)WA HELGNT '� •.� 6. ALL SPECti<A1015 ARE EASED ON 10' ROOF AHOLE MAX AND 90EWALL HED L 106• MAX '�� �n �• • • . •• •L �i % • r .+ �• JACOBSEN HOMES HOTIM DES s,•E mam m Ii rt ■ 0MX- MIO O MX AV M*UXft DRANK 11% " P.O. Box 36B MATEAMLS or InCOtSO1 MWACAI M SAFETY HARBOR, FLORIOA 34695 PHONE (727) 726-1135 NOW MR ICAt lAFM &M MR K M71 IC frl VAL AW t07QROB OM6 mmmmu Iz SEE Nm S Fm pium 1t]o1T r ®m %WRONE B/M (110 MPH) • 20 PSF ROOF 10 PSF D.L. OAPIA APPROVAL: 'o;+� APPROVED BY ON Dec 23,2006 P INC.r • ; •; FED W M~ACUMD 11011E cm, RIICI M AND SAFETY STAY omm r 7RX mx- 11-28-06 RER � FIGURES 100 AND 10.1 Ut AD-M-0086 59 ADDENDUM (108 PIDEWALLP) �%� NORMAL TIO-DOWN SPAfta TABLES �.`� ZONE 11 & III/EXP. d & D CC��V�F o!� LONGITUDINAL TIE -DOWN SPACING TABLE MIN.• FLOOR #OTH LINO Z0 H 00 ZONE m Ot OTx Ek SELtidt t il+l 9 OTT; Ek do OF Ek SEC! 6 12`-O` 2 53' 3 40' 3 37, 3 46' {5-4` 3 46' 4 40' VERTICAL TIE -DOWN / FRAME TIE -DOWN PP ACING TABLE VN FLOOR ODTH VAI EAVE OVERHANGHMT %D ZONE tl 00 ZONE AI VAX Pa AmA m, SPA* VAX +M AW' 12'-0' 6' EACH SIDE 5'-4' 72` 35' TO W 54 38° 45' IS-4' 6' EACH SUE 1 5'-4' 8T 35' TO 40' 1 54 42' 45 15-4' 6` EACH SIDE 5'-4° 80` 40' 1 54 48° 45' LONdITUDINAL TIE- DOWN SPACING TABLE INN.#wzw FLOOR #TH It ift ZONE lu on. Ek END OF Ek 5Ectlol taa E Ek s[COC N Mt e {2'-0' 3 M 4 40' 3 52' 4 45' 44' 4 56' VHRTIGAL TIB- DOWN / FRAME TIE -DOWN OPACINO TABLE FLOOR 09TH VAX EAVE OVERHANG 00 ZONE 1 ZONE AI SPA* VAX W Am' SPA* PAPER WWI ApsLwi` 6 EACH SIDE 4'-0' 72` 37' 4'-0' 34' 40' TO 45' 6 EACH SIDE 1 4'-0' 720 40' 4T-0' 38' 40' TO 45' 15'-4' If EACH SIDE 4'-0' W40' 4'-0' 42' 40' TO 45' NOTE: WHEN ANCHOR ANGLE FROG{ VERTICAL CANNOT BED ACHIEVED. ADD APPROVED STABILIZER PLATE. SEE NOTE 15 FOR HOMES SET IN FLORIDA NO Os 1. SEE Fla.l ADOENDtl�I FOR AT>WRGNAL REOUIRE�iEFpS 2 TA81f BASED ON ANCHGR 1yo�+aNG LOAD OF 3,150/ AND OIAG0 k TIE TO GPPG9TE eEAli 1 VAX EAVE VIMANG REFERS TO OVERHANG AT SWE*Aa NOT FRONT OR REAR 4. AA990011I�� TABLES APPLY TO 144' me AND 1844 FLOOR WD1H5 TH 95 1/2° -eEAIJ SPACK Tor I1AmVLF E oE�J� F�iDG41T AND V VA104O4 SCE OVERHANG (Ir Offi AJIG I!{FTj 5. STAamp PLATES ARE REMIED ON 9DE*ALL ANOLORS AND LONGITRDFNAL ANDM SET ►1 FLOtEOA. SEE DUV RLRE 19C, UFECRVE VARM 29. 1999 0°j' EN A1; CL1 rr DMA APPROVAL - �,?�� (� ;� � ; ►14: ., t;q �� APPROVED BY A. � ..��,.•� 'r „ es� •', '- ar 25,2008 N AtINC. � � ! ( �] � FEDERAL MANUFACTURED UDME •� 5..YF= ' ;� COMSfRUcnaN AND SAFETY STANDARDS o,. ,-�''• 0p. JACOWEN HOMES P.O. BOX 368 nwcl SAFETY HARBOR, FLORIDA 34695 PHONE HOME: �01�,r F70[LARX�Tp ,,► yA FJiLi AtOF y�toesEtl yAFpIFACttEd{G sup+ rotas ARE AwvMD m IK Tom° 'm EMDa ' E OA = o..T. 'ATE: 12-11-07 REV. LETIM DRA M1c nnE NORM. SPACING TABLES G KOM AD-TD-0087 vu ADDENDUM SHEARwALL TIE-DOWN/PIER. REQUIREMENTS Ir: :Vv umm W. s/K Lam+ . , W. 3/1 ... . ...... nCca s It ioa rs 1 - 1 1 Tt40 PEJI 51ifARYTALIS I 1 TK'0 PIER s1EIIRrYAI15 1 (ALL 3ITW110lM 1 1 (AIL 11TUAWQ 1 DE-oosMS W-0ows Now" *Tr 1 I_oeSEE 5LE Nam 1 sm NOTE 1 NOTE 1 SEE NOTE 14/1'�* SEE NQTE.s 2 AND 3. Q A SEE WM 2 AM 3. A ME1t Rt4b PIOI R£dC to pam PIER TMb IRS LO[AT104 '"I EDCJ`T" 'MS LOCAT" T1es LOCATION FIGURE 8, 0 FIGURE 8.1 THE DETAIL AGONE IS SHOWN IMTH A Two PIER SHEARwALL CONFIMRATION, HOWEVER, THIS DETAIL APPLIES TO ALL SHEARwALL CONFIGURATIONS, ALL ZONES. -AND ALL °l.F VALUES. At NorEs: OERAL "ovri 1. TiE-0aw+s RGxs&n a TKY Tc-anal z1ww.AT La.,�n IN �� OVED BY QIFER a 114 ACW suet/ A804fE (MGT RIDI1� AT eo1x1 ;.;��'�:i p I (Kcotaa-Mgova w ac RA � um w wim A , ;%� v� [-. EB 10 IF 2000 at Ao-�a-oovt (ro-caD+cRu Mo s WAL A M AT VNW Do ff ThE se AAW L 30OTs ru TW Aeo1C cRuL1� JAM Rrgj= AT EACH 00 00 .dSV3 ac& uss or JE-w•,+ MW kc4AXes) 910334 1 * INC 3. 11O SH[i� SUL S L=IW A'QK A MW KAM (Fl[I. HmIT qas-M�0 no � �•� T K-POW 3DWS OR FAW AW X(aJM (AL 91rA %qL CWMPLAWn ALL TLN3 4UfACTUHEO HOh1E ADO AIL (�RW's ;: � % . STATF OF � �� d N AND SAFETY STANDARDS J AC 0 l3 S E N HOMES 11" IK rKATOa PC ���.�•`�� R.R. CATG 02-01-00 �V. w ►Tx c acx^. F40FREZuv, ym a P.P. "X aq YAUMI of 4WM37 Y�{0 1 1 S/Vi( TIE/PIER REQ. (� SAFETY HARSH FLORIOA 31905 w- IM r1Mq1A PHOHE (7V) 729-1138 OwnM.,�xt � �1 A eere= • le GRA"I raa�etx: . AD-TD-100 61 ADDENDUM DOUBLE SHEARWALL CONFIGURATION SINGLE -SECTION TIE -DOWNS / CUNG WAY BE FLAT OR SLOPED SIDE VIEW 1 IX X .OW TIE -DON STRAP CONTIMJO'JS ARLXNA MTS. END VIEW 350 PLF MUM SHEARWALL DEMN VALUE (PER WALL) -- I I/4' X .035' rE OOWN STRAP CONANUCJS ARMNE) JOISTS. NOTES: - Z 1'(p E iJi AP�1Ro1'Ai . ,� t/y •� DAPIA APPROVAL: W. Ow" A.40IORS TO BE RATED FOR AN %X'WATE LOAD OF 47251 [3150 DESGIW LOAOJ (SEE AD-ID-CKgI [lp-cFNERAL NOTES] FOR NOTES ON fR000 AKNOR IN�TA11Ana1.) ? 1 APPROVED Bl? .� 2 INSTALL A PER AT EACH END OF THE SIEWALL DUSTS (PER THE ABOVE DETAILS). 3. *IEN 9$ARWA& 15 LOCATELI ABOVE A SOLID LEADER (FULL W04T CROSS-uDMFP.) NOON TE-007V STRAPS OR PERS ARE REOUWFD (ALL SIEARWALL CONFIGURATIONS, ALL ZONES ` ^�+ ; AND ALL DFOA>tiES). (� = I 4. 1E-DCrtN STRAP REOUIRFT) AT EACH END Of JOISTS, ALL l>B_ PW CONFIGURATIONS. �i �. ,.. 5. CEILNG S4OIIN FLAT -OPT, CATYEDRAL OR SLOPED CEUNC LIAY BE USED. �i � t)'n :: ': r ��� ��� '.Tkuu4s�l s!: •w! 6. FULL WIDTH SHEARWAMS ARE SHON11 IN THE DETAJL•ABoVE. HON`VER RNY LENGTH ������`�' �� cacTR: OR C&MGURAT*4 SHEARWALL WAY BE USED. �l�11111IL1I111 NOTICE DRAAN BY: DATE REV. LET JACOBSEN HOMES .> SPEC711GADDNS AN1MAwNOs ARE R.R 2-6-96 OMWAL. PROPROART, AND GWIDEMnAI DRAVANG 11T�E: 5pmr P.O. BOX 365 UATER.ALS OF JACOGS94 UANUFACTURNG DBL. S W CONFIG. TIE -DOWN SAFETY HARBOR, FLORIDA 34695 W_ StCH MATERIALS ARE PROV= TO THE PHONE (813) 726-1138 KEPT DOW N1LOR � M T TRW DDMWnT S DRAN1Nrr NUMBER: AD-TD-0110 aD CEILING WAY BE RAT OR DOUBLE SHEARWALL CONFIGURATION TRIPLE & MULTI SECTIONS SIDE VIEW SIDE VIEW (MARRIAGE WALL APPLICATION) �( (SIDEWALL APPLICATION) 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) 1 1/4' X .035' TIE -DOWN STRAP — 36' MIN. CONTINUOUS AROUND JOISTS. 350 PLF MAXIMUM SHEARWALL DESIGN VALUE (PER WALL) 1 1/4' X .035' TIE -DOWN STRAP CONTINUOUS AROUND JOISTS. IN IS A TRIPLE WIDE RAFTER; 1 APPLICABLE TO STANDARD ILE WIDE TRUSSES. JD VIEW X .035' TIE -DOWN STRAP JOUS AROUND JOISTS. NOTE: ALSO APPLICABLE TO 'SUP SIDE' MARRIAGE WALLS AMEN AT LEAST 2 STANDARD VERTICAL TIES ARE INSTALLED, (I EACH SIDE ADJACENT TO SHEARWALL LOCATION) Q TO r X/1 ' � 35 NOTES: EN014UR APPROVAL-. DAPIA.APPROVAL• I. GROOPD ANCHORS TO BE RATED F(R AN ULTIMATE LOAD OF 47251 (3150 DESIGN LOAD) (SEE AD-TD-DOOI (M-QMAL NOTES) FOR NOTES ON GROUND ANCHOR Y6iAUATION.) 2. INSTALL A PER AT EA04 ETD Of THE SHEARWALL JOISTS (PER THE ABOVE DETAILS). p APPROVED Ely 3. MHEH SHEARWALL IS LOCATED ABOVE A SOLID HEADER (FULL HEIGHT CROSS -MEMBER) NO ef IIE-DOVNSTRAPS OR PIERS ARE REQUIRED SHEARWALL COHFWRATIONS. 1 (ALL ALL HONESAJID ALL EA 4. TIE-DOW:E STRAP REQUIRED AT EACH END OF JOISTS. ALL DBL S/W CONFIGURATIONS. //'o A John. C. Doe den,-/F.E. IN A 5. CEILING S?HO'AN CATHEDRAL OR SLOPED, FLIT CEILING MAY BE USED. ]� 133 C. R. 22 6. FULL w;DTH 94ES ARE SHOWN IN THE DETAIL ABOVE HOWEVER, ANY LENGTH OR CONFIQf.2ATION 0N SHEARWALL MAY BE USED. Goshen, IN 46526 7. THIS DEIKL MAY APPLY TO TRIPLE AND/OR DOUBLE WIDE SECTIONS. JACOBSEN HOMES NOTWP. TIHESE sPEananAND AND HIRAWiI1C5 DRAWN BY: R.R. DAIS 4-09-96 REV. LETTER ARE ORMAL PROPRIETARY, ANO ODNFID0HTIAL . MATERIALS Of JACOBSEN MANUEACMUC / DRAWING E: ME S/W CONFIG. TIE —DOWN „ P.O. BOX 368 NG SUCH MATERIALS ARE PNOVIOED 10 THE 7O 695 SAFEPHO PDra M PURPREI AlSMM DRAWING NUMBER: ER(83) -1138 nWU AD-TD-0111 61 PORCH ANCHORING DOUBLE HEADED 3,1! NOTES: 1. SE SET-UP MANUAL AND ADDENDUM FOR APPLICABLE BLOCIONG REF.`,CALCS.-! ENGIN X .035" TIE -DOWN STRAP JOUS AROUND STRAP IBLOCKS. MNDZONE III EXPOSURE IC 1110 MPH) 20 PSF ROOF 10 PSF D.L. c lVq 1491 'ED BY OL"Z is 19INC. RAIL MANUFACTURED HOME NSTRU RMION AND SAFETY STANDARDS li 4 mv NOTICE DRAVM BY: M.T. GATEREV.IV. LETTER:JACOBSEN HOMES wgSpECFjCAT0d AND DRAVINGS ARE MONAL PROMUM. AND OMOIDUMAL DRAVANG TITLE: P.O. BOX 368 MAIEWALS OF JACOBSEX MANUFACUM4 PORCH ANCHORING m Suol MATMALS AREPRDWED 10 4E SAFETY HARBOR. FLORIDA 34695 WWI RR SPEOFiC POW " m5T BE DRAVANG NUMBER Em PHONE (727) 726-1138 KEPI CMfVoffK AND SF!:RlT FROM OHM AD-TD-0112 64 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION APPROVED VERTICAL TIE-D (FACTORY INSTALLED)FLOOR DIAGONAL FRAME TIE ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD REQUIRED ON THE TIE -DOWN SPACING TABLES (SEE OTHER DETAILS FOR TABLES) SEE OTHER DETAILS FOR ANCHOR ANGLE. �— CRIMP SEAL (3150/ WORKING LOAD) d x �C Q Vl J Q VERTICAL ME -DOWN O TYPE 1, FINISH B. W GRADE 1 STEEL STRAPPING c 1 1/4' WIDE h 0.035' IN THICKNESS, CERTIFIED BY w A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91. STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL, AND SEALS. NOTES: 1. ALL VERTICAL TIE -DOWN STRAPS, DIAGONAL FRAME TIE -DOWN STRAPS AND ANCHORING EQUIPMENT SUPPL BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REQUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). JACOBSEN HOMES P.O. BOX 368 SAFETY HARBOR, FLORIDA 34695 PHONE (813) 726-1138 OWN ANCHOR BRACKET RADIUS CLI^ RADIUS CUP MUST BE INSTALLED ON ALL TIE -DOWN ANCHOR BRACKETS (INSTALLER TO FABRICATE RADIUS CLIP BY PLACING A STRAIGHT 3' LENGTH OF 1 1/4' X 0.035 TIE -DOWN STRAP MATERIAL IN ANCHOR SLOT AND BENDING TO FORM THE CONFIGURATION SHOWN.) RADIUS CUP MUST BE INSTALLED TO PROTECT THE TIE -DOWN STRAP FROM THE BRACKET EDGES. INSTALL THE TIE -DOWN STRAP THROUGH THE SLOT IN THE BRACKET '2LM r THE RADIUS CUP. c T r'_ f�'KQRO" ANO. 10 ENE870357 �?' \� .� /0A1A�L E��, ANCHOR lIEuk'1I1AND,TE-DO%W DEVICES ARE CERTIFIED BY OTHERS NOTICE: �lA*►+ Rr TKsE 9°ECY1017m Alm DRMIR65 ARE UNIKAL PROPRIETARY, AND CCfdMT11L 11ATE1MALS OF JACMXM YM"ACMW nL 9" MAIERIN.S ARE PR01 M TO THE KCPD(f rGR 9iCrX 144WOM 00 KITI BE PM COIfW%& 90 SE00 lRCY OWE C.L.Y. PROVED BY JUh1 1 5 INC. IlOEA1l WMNi11�lO! woftamin1umwom 5-31-95 1 ALT. TIE -DOWN APPL. A AD-TD-0200 65 ADDENDUM ALTERNATE VERTICAL TIE -DOWN APPLICATION FLOOR IF FACTORY INSTALLED STRAP IS NOT LONG ENOUGH, - IT MAY BE LENGTHENED BY USNG A CRILIP SEAL WITH A WORKING LOAD OF 3150 POUNDS L ERTICAL TIE=DOWN ANCHOR STRAP TALLED) -ol_ T IF NEEDED, USE VERTICAL TIE -DOWN TYPE 1, FINISH B. q„ �k GRADE 1 STEEL STRAPPING r�J NI fTHICKNESS. CERTIFIED BY A REOSTER£D PROFESSIONAL ENGINEER OR ARCHITECT AS DIACONAL FRAME TIE CONFORMING WITH ASTM STANDARD 0 SPECIFICATION D3953-91, 0 STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL. AND SEALS. II III -III -III 1(- ANCHORING EOUIPMENT —III III -III -I i CAPABLE OF RESISTINGTHE WORKING LOAD REQUIRED ON THE 1—III —III-I TIE -DOWN SPACING _ TABLES (SEE OTHER I III -I I (- DETAILS FOR TABLES) _ SEE OTHER DETAILS FOR ANCHOR ANGLE.Ll NOTES: 1. ANY ADDITIONAL VERTICAL TIE -DOWN STRAPS, DIAGONAL FRAME TIE -DOWN STRAPS AND ANCHORING EOUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EOUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REOUIRES THE USE OF EXTERNAL STRAPS OR CABLES (SEE RADIUS CLIP). JACOBSEN HOMES THESE SPEOriGRON$ AND DRAMS GS ARE ® ORIONAL PROPRIETARY, AND COrH1DENiuL ORA%lNG TITLE: P.O. BOX 368 MATDOALS OF JACDBgN MNAJTAlCiZ �v IHr. SUCTI MATERIALS ARE PROVIDED TO THE SAFETY HARBOR, FLORIDA 34695 REaMI rat SPECM PJR1'M AND Must BE DRAWiIIG NUMB PHONE (813) 726-1138 IVT CON IDEHDAt AIO SLDST rROM OrdM APPROVAL: APPROVED BY 1 04" N14REVISED INC. FEDERAL MAIAiACT1iED HOME CJ TRUCTM AND WETl FTANDAF" R.R. DATE 10-05-96. REV. LETTER; ALT. TIE -DOWN APPL. AD- TD- 0210 66 ADDENDUM COLUMN TIE -DOWN APPLICATION COLUMN 'A' COLUMN SEE TABLE FOR MAXILIUM SPAN FOR COLUMNS 'A' OR Ti' COLUMN 'C' COLUMN V ISEE TABLE FOR MAXIMUM SPAN FOR COLUMIG 'C OR V _ J SEE TABLE FOR SPAN COL 'f SEE TABLE FOR MAX'SPAN FOR COI. 'G' COLUMN 'E' COLUMN 'P CmUwI 'G' SEE TABLE FOR MAXIMUM SPAN•FOR COLUMN i MAXIMUM ALLOWABLE SPAN TYPE Of ANCHORM REQ`D COLUMNS W. V. V OR 'E' COLIANS V OR 'G' COLUMN 'F (SEE AD—M-0251. AD-7D-0252 AND ZONE 2 ZONE 3 ZONE 2 ZONE 3 ZONE 2 ZONE 3 AD—ID-0253) SEE HOLE 1 EXP. 'C EXP. 'D' EXP. 'C' EXP. V EXP. 'C' EXP. V EXP. 'C' EW. V OP. 'C UP. V EXP. 'C' OF. V 2 — 31501 ANCHORS 43'-0' 29'-6' 3Y-9' 23'—r 4S-0' I9'-6' 33'-9' ' 23'-7' 41'-0' 29'-6' 31'-9' 23'-7' 1 — 31501 ANCHOR 21'—C 14'-9' 16'-10' 11'—IO' 21'-6' 14'-9' 16'-10' 11'—IO' 21'-6' 14'-1* 16'-10' 11'-10' I — 40001 ANCHOR 27-3' 18'-9' 21'-5' 15'-0' 27-3' I6'-9' 21'—S' 15'-0' 27-3' 18W 21'-5' 15'-0' NOTES' EHGHEER APPROVAL' DAPIA APPROVAL' APPROVED $Yxv— 1. SEE AD-TD-0251, AD-TD-0252 AND AD-TD-0253 FOR SPECIFIC INFO. ON ANCHORS. jLjj 1 5 2. SEE AD-TD-0001 FOR ADDITIONAL NOTES ON ANCHOR 'N A INSTALLATION. John C: Doeden, •«R. � INC ' 15133 C. R. 22 Goshen, IN 46526 JACOBSEN HOMES N077CD wsE snancAma me ARE DRAW BY. C.L.Y. DATE. : 5-31-95 REV. LETTER: Mon muV00 DMONAL. PROPRETARY. AND C01tlMTIAL MATERIALS MANUFACV.4" TILL ORAIAVIG TITLE: COL TIE -DOWN APPL. „ P.O. BOX J68 OF ACOBSf1I YiC 6UGH MATE U ARE MONO M W ORATANG NUMBER: AO-TD-0250 SAFETY HARBOR, FLORIDA 3"95 PHONE (813) 726-1138 NOW FOR SECM WOKS NO Mh16E ml wfmTUL AID SECRET Mw GTom 67 ADDENDUM COLUMN TIE -DOWN APPLICATION Hamm imE GF IMn-WIDE FLOOR I FLOOR ANCHORING EOUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 3150 / MIN. O ANGLE SHOW. =T1T=1 T 1=1TI 35 ANDE I I -III —III— ANOIORS INSTMM 24' APART COLUMN STRAPS SEPERATE GROUND NOTES: 1. ALL ANCHORING EOUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS— ON SITE. 2. ANCHORING EQUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR— ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REOUIRES THE USE OF EXTERNAL STRAPS OR CABLES. ATTACHED ANCHORS ..,111111u1i..._ VERTICAL TIE -DOWN TYPE 1. FINISH B. GRADE 1 STEEL STRAPPING 1 1/4- WIDE k 0.035- IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH AS7M STANDARD SPECIFICATION D3953-91. STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. 3Y ANGLE TO TWO (3150# EA.) /i DAPIA APPROVA XV � : Q� No. Fo•.2 _ ENE8703571% t ?•� AL AF1= ED 8Y po.,,,.. ,N 19T � .Jllnl 1 5 Rmft icnmmw �NC g coamcTm AIaSIVmaww= JACOBSEN HOMES P.O. BOX MSE w nc am Aw OIW.3 ARE WIMM. PROPINIART. AND COttl10E11TMI. MAM MIS OF JACOM MAMNACV"C INIAWNBY. C.L.Y. DATE 5-31-95 HEY' LLTIM n DRAWING InE: COL. TIE —DOWN APPL. „ SAFETY HARBOR. FLORIDAR134695 SKM MMI We MLS ARE PROMM TOM RTCPINI Pa 9 X PUiPM NO WSI K 'H` DRAWING NUMBER PHONE (813) 726-1138 PVT Ca Mnk NO woo ntm orrm AD— TD-0251 6$ ADDENDUM, COLUMN TIE -DOWN APPLICATION ANCHORING EOUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 3150 / MIN. MARRIAGE LINE OF IA&M-ADE FLOOR 11 FLOOR 101 VERTICAL TIE -DOWN TYPE 1. 'FINISH B. GRADE 1 STEEL STRAPPING 1 1/4' WIDE & 0.035' IN THICKNESS. CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91. STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL. AND SEALS. COLUMN STRAPS ATTACHED TO A SINGLE GROUND ANC,H2O,RI„ (3t5O#) NOTES DIO CL`O ii��'' DAPIA APPROVAriS 1. ALL ANCHORING EQUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. T - : Q. NO, p , y PROVED BY ; NES% 2. ANCHORING EOUIPMENT EXPOSED TO WEATHERING - 5 10 SHALL HAVE A RESISTANCE TO WEATHER DETERIOR- JUN 1 AT10N. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS _- � ��p '. 6 4 ��' '%'�F'• NQ)•\� I INC_ " """��y�yp WHERE THE ANCHORING SYSTEM REOUIRES THE USE OF EXTERNAL STRAPS OR CABLES. ``�� '�i �S •'"••••"�� �` JACOBSEN HOMES NOMC& TdM VEMWAr IS AM RIR ym ARE ItRAW4BY. C.L.Y. DATE 5-25-95 REY. LETIFR DRAWING iIT E: COL TIE —DOWN APPL. P.O.80X 368 QVMAL PROPR IEURT. AND OOMR)IM Y1iQ"ALS 6F JACOBSEX MA"ffACWWO SAFETY HARBOR. FLORIDA 34695 PHONE (813) 726-1138 THE REEMM FIR �E�au NO TOK K" CWWPA AW %0V nMU OHM DRAMNG NUMBER AD—TD-0252 . RQ ADDENDUM COLUMN TIE -DOWN APPLICATION FLOOR ANCHORING EQUIPMENT CAPABLE OF RESISTING THE WORKING LOAD OF 4000 i MIN. COLUMN STRAPS SINGLE GROUND NOTES: 1. ALL ANCHORING EOUIPMENT SUPPLIED BY AND INSTALLED BY OTHERS- ON SITE. 2. ANCHORING EOUIPMENT EXPOSED TO WEATHERING SHALL HAVE A RESISTANCE TO WEATHER DETERIOR ATION. 3. PROTECTION SHALL BE PROVIDED AT SHARP CORNERS WHERE THE ANCHORING SYSTEM REOUIRES THE USE OF EXTERNAL STRAPS OR CABLES. C MARRIAGE LINE OF MAI-HIDE FLOOR VERTICAL TIE —DOWN TYPE 1, FINISH B, GRADE 1 STEEL STRAPPING 1 1/4- WIDE & 0.035- IN THICKNESS, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER OR ARCHITECT AS CONFORMING WITH ASTM STANDARD SPECIFICATION D3953-91, STANDARD SPECIFICATION FOR STRAPPING. FLAT STEEL, AND SEALS. ATTACHED TO A ANCHOR (4000#) ...un1111ij .- ��: G�STEyFUc%1 P No. O ''���i, ssln Al h 1 • rO APPROVAL• OVED BYE, jM1510 INIM INC. cmftc cmAMosvmsTAMw f NOMCR -"I IDHAuvar. DATE: REV. LETTER JACOBSEN HOMES 11ESE SPEOFIGITIOIIS AID DUN= ARE C.L.Y. 5-25-95 CRaMAL PROPRETARr AMO ,I COMIOOiTIAL DRAWING TITLE: P.O. BOX 368 MA1MALS OF JA "ffACmw_c COL. TIE -DOWN APPL. RIG SM MAlIM ILS ARE PRD OM TO 1K SAFETY HARBOR, FLORIDA34695 RECPEM FOR SPECt1C F7pw= NO MIST x DRAWING NUMBER PHONE (813) 726-116-1138 ISPT CM# MTK AM SEOV IRM ODOM AD—TO-0253 70 ADDENDUM 184" WIDE COLUMN TIE -DOWN APPLICATION COLUMN 'A' COLUMN $ -- - - - - - ISEE TABLE FOR YAXIIM SPMI FOR COLUMNS 'A' OR r � COLUMN 'C' COLUMN 'D'� I APPROVED EY ISEE TABLE FOR MAXIMUM SPAN FOR COLUMNS '1: OR b' _ SEE TABLE FOR SPAN COL 'E' i SEE TABLE FOR MAX SPAN FOR COI.. ' INC. FED LMANUFACTURED HOW RUCTION AND SAFETY SWIDAROS MAR 0 3 1999 COLUMN 'E' COLUMN 'F' COLUMN 'O' ISEE TABLE FOR uAmum SPAN FOR COLUMN'r i MAXIMUM AUDWABLE SPAN TYPE OF ANCHORNO REO D (SEE AD-1D-0151, COLUMNS •A', V. V OR'r COUIM NS V OR 'C COLUMN r AD-TD-0252 AND AD-1D-0253) ZONE 2 ZONE 3 ZONE 2 ZONE 3 ZONE 2 ZONE 3 SEE NOTE 1 EIHP. •C' EV. V EXP. •C• Ems. V E7(P. 'C' Dr. V DF. V I Ems. V DP •C' EXP. V EW. V EXP. V 2 - 3150/ ANCHORS 31-4' 25'-6' 2V-4' 2O'-4' 371-4' 25'-6' 2V-4' 20'-4' 37'-4' 25'-6• 29'-4' 20-4• 1 - 31501 ANCHOR i1F-6' 12'-10' 14•-7' 10•-3' 18'-6' 12'-10' 14'-7' 10'-3' 1I'-6 12'-10' 14•-7" 10'-3' 1 - 40DOI ANCHOR 2S-8' 16'-4• 1I'-7' IS-0' 27-B' 16•-4' 16'-7- IS-0' 2S-8' 16'-4' 18'-7- 1 13'-0' .REF. CALCS c %✓ 93� a( TES: ENO ... 4C 'i,, R '•• 3 y DAPIA APPRGvA 0NO 1. SEE AD-TD-0251. AD-TD-0252 AND AD-TD-0253 NO. FO • AppRpVED BY FOR SPECIFIC INFO. ON ANCHORS. 910334 2. SEE AD-TD-0001 FOR ADDITIONAL NOTES ON ANCHOR INSTALLATION. •• 4F .-o STATE 4 '4` ,np�Io,�www JACOBSEN HOMES NOTEO� TIwm SKa u;ATma M M NM AM ORA M T DATE REV. REV. LETTEx ORAYANO "ILE. 184" WIDE COL. TIE -DOWN APPL. . CRKWA. PeOPMART, Arm OOIII10E M MAXNALS'OF JALO�R MOWACNRN6 P.O. BOX 368 R+c 9KH MA1EFOALS ARE FRONDED TO IK OWA—wm- EMI m AD—TD-0254 SAFELY HARBOR, FLORIDA 34695 RECAM NCR SPECAC FLWM NO um BE PHONE (727) 726-1138 PUT DORrwa mE mo sm nw ODm 71 ADDENDUM TYPICAL SINGLE WIDE TIE -DOWN PLACEMENT SEE NOTE 2 B C 4 LARGE OPENING 24' SEE NOTE 1 a i m,LJMY vLn in m NIL —WHIT .l lr"a Mi Nrjm BRACKETS (SEE TIE-DDWN SPACING TABLES -NORMAL AND/OR ALTERNATE- FOR MAXfWUM SPACING ALLOWED). ALSO SEE NOTE 3. STANDARD VERTICAL TIE -DOWN STRAPS OR ANCHOR BRACKETS TO BE INSTALLED A MAXIMUM OF Z-0' (241 FROM EACH END OF THE UNIT. C �FO� ��' `�� �? • • •15 T E '� NOTES: PR O DARA APPROVAL: 1. LARGE OPENNG = ANY OPENING WIDER THAN MAX TIE -DOWN SPACING ALLOWED.= TIE-571 • __ 2. VERTICAL TIE -DOWNS MAY EXCEED THE STANDARD VERTICAL TIE-DOWNSPACIII., , — ROVED BY SO LONG AS, THE AVERAGE SPACING [ (A+B+C) / 3 ] DOES NOT EXCEED THE MAXIMUM TIE -DOWN SPACING REOUNRED ON THE APPROPRIATE VER71CAL/FRAME ,�' . /� ,�+�� �''., .LV 1 5 M TIE -DOWN SPACING TABLES (SEE OTHER DETAILS). Fs+ '' • .. �... • '\���.• S�Di��AL INC 3. INSTALL FRAME TIES AT All VERTICAL NE -DOWN LOCATIONS. ��i �N.�• 4. SEE AD-TD-0001 FOR ADDITIONAL REOUIREMENTS III I1lim III% .:.:_.'-.wv y MGM ANCHOR BRACKET AND TIE -DOWN DEVICES ARE CERTIFIED BY OTHERS JACOBSEN HOMES naSE sK� � MAW= AM DRAWN BY. C.L.Y. °A' 5-31-95 my' LETTER: ■ BOX „ CROWN. PROVEMY, AND CON FWTIAL MATMALS OF JACOBSEN MANUFACR MG wa YATFA1AlS ARE PROW0 TO THE n DRAWING TITLE TYP. SINGLE WIDE T/D HARBOR. FLORIDAINC, SAFETY HARBOR, ORI34695 PHONE (813) 726-1138 R[CpDrt FOR 901C PUFOW AND WR K ar r ammmAl me mou nu ormm /H` DRAWG NUMBER: AD—TD-0300 72 ADDENDUM TYPICAL MULTI- WIDE TIE -DO WN. PLACEMENT SEE NOTE 2 A B C 24' LARGE OPENING n24' ..SEE NOTE 1 n n n n n n n n COLUMN SUPPORT TIE -DOWN STRAPS. REMO AT COLUMN LOCATIONS ON EACH SIDE OF OPENING GREATER THAN 48`IN WIDTH. MULTI -WIDE FLOOR SHOWN SEPERATED FOR amTY Ld D24' STANDAROWN STRAPS D VERTICAL TIE-DOR ANCHOR RODS (SEE TIE -DOWN SPACING TARS -NORMAL AND/OR ALTERNATE- FOR UAWN SPACING ALLOWED). ALSO SEE NOTE 3. STANDARD VERTICAL TIE -DOWN SIM OR ANCIiOR BRCWM TO BE INSTALLED A MAXIMUM OF 2*-0' (241 FROM EACH END OF THE UNIT. FOR TRIPLE WIDE AND LARGER UNIT DESIGNS. INSTALL ``,%C+ 0�1111111 iij,"� ALL TIE -DOWN STRAPS AS SHOWN IN 116 DETAIL %%` p�'��i NOTES: 1. LARGE OPENING = ANY OPENING HIDER THAN MAX X—DOWN SPACING ALLOWED. 2. VERTICAL TIE —DOWNS MAY EXCEED THE STANDARD VERTICAL TIE —DOWN SPACING SO LONG 4 THE AVERAGE SPACING ( (A+B+C) / 3 ) DOES NOT EXCEED THE MAXIMUM 11E—DOHN SPACING REQUIRED ON THE APPROPRIATE VERTICAL/FRAME TE—DOWN SPACING TABLES (SEE OTHER DETAILS). 3. INSTALL FRAME TIES AT ALL VERTICAL TIE —DON LOCATIONS. 4. SEE AD—TD-0001 FOR ADDITIONAL REQUIREMENTS. DAPIA APPROVAL Q� IVO. O NE8703571 ' OVED BY ar Z 5 10 DEVICES ARE CERMED BY OTHERS JACOBSEN HOMES TKSE s,� OMATilo 5 NOTICE DR UNM ME DRAWN BY: DATE REV. lEtiER . � C.L.Y. 6-1-95 MONAL Pa0PWMY. AND oo lMNU% DRAWING 1111E TYP. MULTI —WIDE T/D A P.O. Box 368 MATERIALS OF JACOM MWAC1URING „ MW TO THE SAFETY HARBOR. FLORIDA 34695 Ff"fff fCR � �S NO VM K DRAWING NUMBER PHONE (813) 726-1138 IVT CO W%4L NO YCRCT IRCY OrMM I AD—TD-0310 -rd.% SINGLE WIDE TIE -DOWN ZONE I TIE -DOWNS MARRIAGE WALL I OPENING TIE —DOWN (REQUIRED AT OPENINGS I ONLY. OPTIONAL AT SEE DETAIL — 'A' OTHER LOCATIONS.) FRAME TIE —DOWN SEE DETAIL — '8' DOUBLE WIDE TIE -DOWN NOTE: C SECTION MARRIAGE WALL NOTE: SIMILAR TO I OPENING TIE —DOWN I A k B SECTIONS SINGLE WIDE SIMILAR TO DOUBLE (REQUIRED AT OPENINGS WIDE TIE -DOWN FRAME TIE —DOWN ONLY. OPTIONAL AT OTHER LOCATIONS.) , PULL DOWN TIGHT TO ---/ GROUND ANCHOR DETAIL 'A' TRIPLE WIDE TIE -DOWN BUCKLE WITH 2O251 fY MINIMUM SEE DETAIL — 'A' SEE DETAIL — 'B' 71E-DOWN STRAP SINGLE HEADED GROUND ANCHOR (WHEN MARRIAGE WALL TIES AND FRAME TIES ARE LOCATED AND SECURED TO THE SAME GROUND ANCHOR, A DOUBLE HEADED GROUND ANCHOR MUST BE USED) ALL GROUND ANCHORS MUST BE LISTED TO CARRY THE LOADING IMPOSED BY THE TIE -DOWN STRAPPING (315o LBS. MAMMUM FOR EACH TIE -DOWN STRAP CONNECTED). DETAIL 'B' TYPICAL TIE -DOWN STRAP (1 1/4' X .OV MINIMUM Z)NK COATED STEEL STRAP, OR EQUAL WITH 315o t CAPACITY MINIMUM) K 1.S= g7ZS 41 UL-Tj^_jnw LOAo Ngr'ACIT'l NOTES: 1. SEE DETAIL 'B' PAGE 4 NOR MARRIAGE WALL OPENINGS GREATER THAN 49 INCHES. & OQ To I-1T-6" T1e16UT 2. SEE TIE —DOWN SPACING CHART ON PAGE 2 EDR s ANCHOR AND PE -DOWN PLACEMENT. 3. SEE DETAIL 'A• PAGE FAIR TYPICAL I -BEAN PIER CONSTRUCTION. Or. •''i ......"` STATE OF I1 •' :f4ORo APPROVED BY 'N'NIIVC cpy�'D{♦pmmem {'lYo" ESwo" JACOBSEN HOMES THESE SPEOFlCAN1100Nn5 #M DRAMRN69 ARE sY. RR DATE, ARE m CRICINAL. PROPRIETARY, AND Coru1DOMAL DRAINING TITLE:P.O. BOX 368 UATERIAS OF JACOM YANUFACTIAt1NG ZONE I TIE —DOWNS SAFETY HARBOR, FLORIDA 34695 RE�FOCI S qERAS �,yo,T„°,.T� PHONE (813) 726-1138 IVT CONiDD ITA AO SECRET 1Rd1 00M DRAINING NUMBER. AD—Z1-0001 74 4c ZONE I TIE -DOWN PLACEMENT TYPICAL I -BEAM TIE-DONN MAIN FRAME I -BEAM SEE NOTE /11• MAIN FRAME I -BEAM END AGNGI CENTER SPACING ACING I SPr SNTER PACING I SPA Gr!r CENTER SPACING ISPACINGI DOUBLE WIDE —TIE —DOWN PLACEMENT END CENTER CENTER CENTER CENTER CFNTFR run ­U .rnuntr WALING SPACING SPACWG TYPICAL I -BEAM TIE -DOWN MAIN FRAME I -BEAM • SEE NOTE #11 SEE NOTE j1�• MAIN FRAME I -BEAM MAIN FRAME I —BEAM END CENTER CENTER END SPA. SPACING SPACING ISPACLNGI ce 9- co TRIPLE WIDE TIE —DOWN PLACEMENT NOTES: ENGINEER�to� .. DO�O DAPIA APPROVAL: T' SEE DETAIL 'B' PAGE 4 FOR BLOCKING AND ANCHORING OF ••••,)D: �QITIFi'* �`ti''- APPROVED BY MARRIAGE WALL OPENINGS %MDER THAN 49 INCHES. .• ., No.0045484��; • T 'STATE OF • 10t. e. .•'��i?��•, ,. swovts>s . "NG� ` JACOBSEN HOMES NOMCE ,�yyra�T! DATE' REV. LETTER ■ TNESE SPEOi1CATIORS AND DRAVINGS ARE RR 10-31-95 ORIGINAL, PRWWARY. AND CMIDENTUL ORAMNG TITLE- P.O. BOX 368 MATERIALS OF JACOBST:N MANLIFACTLWNC TIE —DOWN PLACEMENT „ WG SUGIi MATERIALS ARE PROVIDED TO THE SAFETY HARBOR. FLORIDA 34695 REOpE)(f FOR SPCCIIC RMOSES NO UM BE DRAWING NUMBER PHONE (813) 726-1138 NST MNUNML AND S;OM ERDIt oBERS AD-Z1-0020 79 ZONE I INSTALLATIONS 1. FOR HOMES LOCATED IN ZONE I, FOLLOW THE MANUFACTURER'S ZONE 2 INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF LONGITUDINAL ANCHORS. 2. FOR HOMES LOCATED IN ZONE I ONLY, FOLLOW THE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR THE INSTALLATION OF SHINGLES AND/OR LAP SIDING. FOR ALL OTHER WIND ZONES REFER TO DETAILS IN THE SET—UP MANUAL AND/OR THIS ADDENDUM. DANA BY acd' FE13 0 1 2000 INC. )HOME NOTICE.` unnm+ or. unit: mT. «•• JACOBSEN HOMES inse >,>� ANDJR►� ARE M.T. 2-1-00 ORCIlA1. PROPQ[UAtt AND J;OW1pEN1IAL DRAWING lXE: /� \I P.O. BOX 36B UAWROU OF JACCSA" PO ~t ZONE 1 INST. A NC. Not M►VMXS JIVE PI�OMDEO f0 Ne SAFETY HAR80R, FLORIDA 3A595 wcmff rm VOt,716 PJWM AM erst R DRAWWG NUMBER: PHONE (727) 726-1136 KPI corlata NO 9:m mow anaas - AD— Z1-0100 77 ADDENDUM FOR INTERSECTING UNITS MAIN UNIT /DORMER I \ _ F Ta I I TRIPLE WIDE OR QUAD WIDE SECTION(S) bl ?I I I �I MAXWIRI PIER HEIGHT FOR VARIOUS ZONES (REFER ALSO TO STDEWALL TIE -DOWNS MAXIMUM HEIGHT} Zff-2 70NE3 EXPOSURE 'C' 90' 56" EXPOSURE V 39' 46' LONGITUDINAL TIES ONLY REWIRED 0 EA. HALF OUTSIDE BEAU IRIS END, EXCEPT FOR ZONE 3 EXP. 'D• THEN 2 REOUIRED EA. HALF (IE CGE EA. BEAM, ETC_.) VERTICAL AND DIAGONAL TIES INSTALLED ALONG THE SDEWALLS SAME AS THE MAIN UNIT. VERTICAL TIES AT CENTER LINE REWIRED ONLY AT COLUMN SUPPORTS PER DOUBLE WIDE CONNECTION REQUIREMENTS. 24" MAXIMUM SPACING TO FIRST SIDWALL TIE FROM EACH END OF THE UNIT (SAME AS TYP. DOUBLE MADE TIE-D0%W REOUIREMENTS). 2 LONGITUDINAL TIES REWIRED AT EACH HALF INS END ONLY. CONNECT THE TRIPLE WIDE OR QUAD. WIDE SECTION(S) TO THE DORMER AND MAIN UNIT PER DOUBLE WIDE MARRIAGE LINE DETAILS AS OUTLINED IN THE SET-UP MANUAL (EXCEPTION: NAILING ONLY IS REQUIRED AT FLOOR CONNECTION. NO STRAPS ARE ' REQUIRED TO BE INSTALLED ACROSS THE FLOOR CONNECTION AT THIS AREA.) NOTES: G ENQtE6PRDVSAL E.'CQn DAPIA APPROVAL T 1. FOR WAD SECTIONS. EACH 'DOUBLE SECTION' OF THE UNIT SHALL BE DESIGNED N0. APPROVED Vp. . INDEPENDENT OF THE OTHER STRUCTURE (IL SHEARWALLS, TlE-DDWNS, RIDGE- /ENEA70357 BEAMS, COLUMN SUPPORTS, ETC... ARE CALCULATED FOR EACH MULTI-SECTION.)JUN _ 1 5 FINC "�'� "ram ' •...... r''�G� �� aalR,aArAwwmsTNa�e Ill., NOTICE DRAVIN BY: DATE: REV. LETTER: JACOBSEN HOMES THESE SPEOnCA11ONS AND DRAWNCS ARE C.L.Y. 5-16-95 WONAL PROPRIETARY. AND OJWWTIAL DRAWING TITLE: P.O. BOX 368 MATERIALS OF JACOBSEN MAJUFACMUG ADDENDUM -INT. UNITS . SAFETY HARBOR. FLORIDA 34695 KCCKNT FOR S'ECFX FJW= NO MM BE PHONE (813) 726-1138 wF cwwnk AND SEM nKu 011m ORAWING NUMBER PHONE 78 ALT. ROOF ASSEMBLY FOR MULTI—WIDES CENTERLINE CONNECTION FOR QUAD UNITS IS THE SAME AS FOR THE MAN UNIT (REFER TO SET-UP DETALS� NOTES: 1. 30 GA. GALV. STRIPS USED MAY BE WIND DEFLECTORS REMOVED FROM ROOF IN ORIGINAL CONDITION (EXCEPT FOR STAPLE HOLES). STEEL STRIN MAY BE CONTINUOUS OR PIECED. 2. SHINGLES IN THE DORMER AREA OF THE MAN UNIT MAY BE SHIPPED LOOSE AND INSTALLED ON SITE AFTER THE UNITS HAVE BEEN ATTACHED TO PREVENT ANY TRANSIT DAMAGE AND TO ENSURE THE SHINGLES UNE-UP FROM ONE SECTION TO THE NEXT. 30 GA. CALK STEEL STRIP INSTALLED OYU MATING LINE JOINT (SEE PUN NEW BELOW) ROOF PERIMETER RAL OR ROM BEAM CROSS-SECTION 30 GA. GALV. STEEL STRIP 8' X LENGTH OF,ROOF SSECTIONS MAYBE OVERLAPPED 2 MIN.) W/STAPLES AS SHOWN. INSTALL ROOF CAP PER SET- UP MAN. OVER GALV. STRIP. (SEE NOTE 1) 30 GA. CALV. STEEL STRIP SECURED WITH 7/16' X 16 GA. STAPLES FULL PENETRATION INTO DECKING 2 " D.C. MAX. SPACING (TYP.) O •G\STf9••..F Q� No. Fp % ENE-8703571 •. mv ..sins; e; '• EN�,. 31 X 5• LAC SCREWS 1B' O.C. (ZONES 2 k 3) STAGGERED ��7 3Y g F E1s' .A)N 1 5 -M INC N097CE N 111f nwvt,: DATE: REVETTER: . L JACOBSEN HOMES THESE SPEOIICATONS AND DRAWI0 ARE C.I.Y. 5-16-95 ■ C MIX. PRWRIETMY. AND CDIa10ND M DRAWING nTLE: �� P.O. BOX 368 Nc am r m JACOM " TO THE ALT. ROOF ASSEMBLY SAFETY HARBOR FLORIDA 34695 WMENT FOR 7W FUl"M NO MST K DRAWING NUMBER: QUADAD02 PHONE (813) 726-1138 IVT ODTWRAL AND sm nm orrm 79 IFIE]FIF ElElEF-1 ElIFF-1 ElElEl JACOBSEN HOMES 600 PACKARD COURT SAFETY HARBOR, FLORIDA 34695 (727) 726-113 8