HomeMy WebLinkAboutNotice of Acceptance (4) REVIEWED FOR
CODE COMPLIANCE FILE COPY
ST. LUCIE COUN SOCC 0
MILAM
/ MIAMI-DADE COUNTY
PGS �I Z PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AN NOMIC RE OU CES(RER) 11805 SW 26 Street,Room 209
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCFE� ) www.miamidade.eov/economy
Gardner Asphalt Corporation
4161 W.716 Avenue FEB 2 5 2022 �
Tampa,FL.33605
@t,l-uala�a�ntY �
permOng
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miarni Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County).and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to performjin the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revolve, modify,or suspend the use
of such product or material within their jurisdiction. RER reserves the right tol revoke this acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Gardner Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo; city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
i
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official,
This NOA revises NOA# 17-1221.15 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
.........:. .. :: ... .... .
NOA: 18-0409.06
MIat4N>zaue eounrnr Expiration Date: 03/28/23
Approval Date: 05/10/18
Page 1 of 6
I
i
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: Asphalt
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
APOC Tuff-Felt 26 36"x 72' rolls ASTM D 226 Type II !Asphalt Satul ated Felt underlayment,2
Manufacturing square 430.
Location #1, 2
United FGUR20 36"x 72' rolls ASTM D 226 Type II Asphalt SatuI ated Felt underlayment,2
Manufacturing square#30.
i
Location #1, 2
APOC 25 36"x 72' rolls ASTM D 226 Type 11 Asphalt Saturated Felt underlayment,2
Manufacturing !square#30.
Location #1, 2
No.30 ASTM 36"x 72' rolls ASTM D 226 Type 11 Asphalt Saturated Felt underlayment,2
Manufacturing square#30.
Location #1, 2
APOC Tuff-Felt 46 36"x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4
Manufacturing square#15.
Location #1
I
E
10 36"x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4
g square#15.
APOC45 36"x 144'rolls ASTM D 226 Type IAsphalt Saturated Felt underlayment,4
Manufacturing square#15.
Location #1, 2
I
No. 15 ASTM 36"x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4
Manufacturing square#15.
Location #1, 2
I
United FGUR70 18"x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 1
Manufacturing square#30.
Location #1, 2
I
I
MIAMMADE COUNTY NOA: 18-0409.06
I Expiration Date: 03/28/23
Approval Date: 05/10/18
Page 2 of 6
I
I
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specification Description
i
GatorSkin 42"x 285.8'rolls ASTM D 226 Type II Synthetic roof underlayment comprised
Manufacturing iof layers of polyolefin film.
Location #3
GatorSkin-10 42 x 285.8 rolls ASTM D 226 Type II Synthetic roof underlayment comprised
Manufacturing �of layers of polyolefin film.
Location #5
I
Weather-Armor CX-L 37.25"x 145'rolls ASTM D 226 Type II High strength hybrid underlayment
Manufacturing comprised of two layers of polyolefin and
Location 93 polyester synthetic fabric with a thin layer
of modified bitumen between the two
iplies.
Weather-Armor SB-1 36"x 65' 8"rolls ASTM D 1970 Glass fiber reinforced,polymer modified
Manufacturing asphalt,granulated self-adhered
Location #4 underlayment.
Gard-Lock 36"x 65' 8"-rolls ASTM D 1970 Glass fiber reinforced,polymer modified
Manufacturing asphalt, granulated self-adhered
Location #4 underlayment.
I
Weather-Armor HT3 39"x 65' 8"rolls ASTM D 1970 60-mils thick(nominally),self-adhering
Manufacturing membrane composed of elastic polymers,
Location 94 bitumen,glass reinforcements and a cross
laminated shleet surfacing.
Weather-Armor FT3 39"x 65' 8"rolls TAS 103 60-mils thick(nominally),self-adhering
Manufacturing membrane composed of elastic polymers,
Location #4 bitumen polyester and glass
reinforcement.
MANUFACTURING LOCATIONS:
1. Tacoma,WA.
2. Eutaw,AL.
3. Hangzhou,China.
4. Springville,AL.
5. Tampa,FL.
' I
MtAMFDADECOUNTY , NOA: 18-0409.06
...� Expiration Date: 03/28/23
Approval Date: 05/10/18
Page 3 of 6
i
i
EVIDENCE SUBMITTED: i
Test Agency Test Identifier Test Name/Reuort Date
PRI Construction Materials GGI-100-02-01 ASTM DI 226 06/22/12
Technologies GGI-101-02-01 ASTM D 226 06/22/12
GGI-132-02-01 ASTM D 226 04/28/15
GGI-176-02-01 ASTM E 226 09/26/16
GGI-178-02-01 ASTM D 1970 10/25/16
GGI-194-02-01 ASTM D 1970 08/04/17
GGI-196-02-01 TAS 103 08/08/17
GGI-206-02-01 ASTM 6,226 03/09/18
GGI-207-02-01 ASTM 226 03/09/18
GGI-201-02-01 ASTM D 1623 01/29/18
GGI-178-02-01 ASTM D 1970 01/29/18
GGI-178-02-02 ASTM D 1970 01/29/18
' GGI-199-02-02 ASTM D 226 12/12/17
APPROVED ASSEMBLIES:
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck.
I
Anchor Sheet: One or more plies of APOC Tuff-Felt 26,United FGUR20,United FGUR70,APOC 25,No. 30
ASTM,GatorSkin,GatorSkin-10 or Weather-Armor GX-L with a minimum 4"headlap and a 6"
end lap mechanically fastened to deck with approved nails and tin caps 6 inches o.c.minimum
at all laps and three staggered rows fastened at 12 inches o.c.minimum in the field of the roll.
Nails shall be driven flush and 90 degrees to the roof deck.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes,&shingles,quarry
slate,metal roof applications, and as an anchor sheet iri roof tile applications.Must Comply with
applicable Roofing Application Standards and Building Codes. 11
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
,
Anchor Sheet: Minimum 2 plies or more of APOC Tuff-Felt 46,United FGUR 10,APOC 45,or No. 15 ASTM
with a minimum 19"headlap and a 6"end lap mechanically fastened to deck with approved
nails and tin caps 6 inches o.c.minimum at all laps and three staggered rows fastened at 12
inches o.c.minimum in the field of the roll.Nails shall be driven flush and 90 degrees to the
roof deck.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes,&shingles,quarry
slate,metal roof applications, and as an anchor sheet in roof tile applications.Must Comply with
applicable Roofing Application Standards and Building Codes.
j NOA: 18-0409.06
Mu►MNnane COUNTY Expiration Date: 03/28/23
Approval Date: 05/10/18
Page 4 of 6
I
I
I
I
i
i
Deck Type 1: Wood,Non-insulated
Deck Description: 1962" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck,membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4"headlap and a
6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Weather-Armor SB-1,Gard-Lock,or Weather-Armor HT'self-adhering
membrane adhered to the anchor sheet with a minimum 3"headlap end 6"end lap.
Surfacing: Shall be acceptable for use in approved asphaltic shingles,wood shakes,&shingles,quarry
slate,and metal roof applications.Must Comply with applicable Roofing Application Standards
and Building Codes.
i
Deck Type 1: Wood,Non-insulated f
Deck Description: "/32" or greater plywood or wood plank
i
System E(4): Anchor sheet mechanically fastened to deck,membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626 with a minimum 4"headlap and a
6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Weather-Armor FT' self-adhering membrane adhered to the anchor sheet
with a minimum 3"headlap and 6"end lap.
I
acing: • Weather-Armor FT3 Shall be acceptable for use in approved asphaltic shingles,wood
shakes,&shingles, quarry slate,metal roof,and mechanically fastened roof tile
applications.
• Weather-Armor FT3 may be used with any approved adhered roof tile system as specified in
their current NOA using the following tile adhesives with current NOA:
■ The Dow Chemical Company's TILE BOND Roof Tile Adhesive
■ ICP Adhesives and Sealants,Inc.'s ICP Adhesive Poly set AH�160
f
Must Comply with applicable Roofing Application St ndards and Building Codes.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city,
state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
Product Control Seal as shown below.
MIAMMADE COUNTY
i I
1
NOA: 18-0409.06
MIAMNDADECOUNTY Expiration Date: 03/28/23
Approval Date: 05/10/18
Page 5 of 6
I
i