Loading...
HomeMy WebLinkAboutProject Information WORKS RECEIVED 1- FEB 2 8 2022 IISt.Lucie County Section A (General Information). 1 Permitting Master Permit No. Process No. I Contractors Name: License# 1 I Job Address 1 I 9 ROOF CATEGORY ❑Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles XMetal Panel/Shingles OW ood Shingles/Shakes ❑ Prescriptive BUR- ROOF wII'C e ❑ New roof ❑ Repair ❑ Maintenance o 1MCE ❑Recove in[LE COPY ROOF SYSTEM` i FQ�MGM C UN d T .®OCC Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total(SF) Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. FT I _J - 11 1 APk u I i 1 I . G i f: I I` i i Section D (Steep Slope Roof Systems) Roof System Manufacturer: '7 a` Lr M e� Notice of Acceptance Number: Minimum Design Wind Pressures, if Applicable(From RAS 127 or Calculations): Zone 1: Zone 2e: Zone 2n: Zone 2r: Zone 3e: Zone 3r: "I Deck Type: 1 v w o 0 1 I I Type Underlayment: S A Roo Slope: ' Insulation: Fire Barrier: j I I PI Ridge Ventj[ ion? Fastener Type &Spacing: � lz i�vG, S�t'Ay(fir i�•'� h NA I 1 Adhesive Type: [ Type Cap Sheet Mean Roof Height: I G Roof Covering: Type&Size Drip Edge: ' I I I I ST. LUCM WORKS {' Section C (Low Slope Roof) surfacing: i Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: manufacturer Zone 1':—" oc @ Lap,#Row ® a0 (If a component is not used,identify as."NA")� Zone 1:�" oc @ Lap,#Rows ® "oa ' �k ��5 System Manufacturer: L PZPA� Zone 2:r" oc @Lap, #Rows ® "oc ' FL•� p �j Zone 3: " oc @ Lap,#Rows �. "or, Approval No.: C V����• V �. i I Number of Fasteners Per Insulation Board: Design Wind Pressures,From-RAS 128 Or Calculations: Zone 1': Zone 1: ZonIe 2: Zone 3: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate ComponeInts Noted andd Details as Applicable: Max. Design Pressure,from the specific product approval Woodblocking, Gutter, Edge 1 Termination, Stripping, system: Flashing, Continuous Cleat, Cant Strip, Base Flashing, Ccunterflashing, C ping, Etc., Deck: eM Indicate: Mean.Roof Height, Parapet Height, Height of Base Type: t 1 Flashing,Component Material, Material'Thickness, Fastener Type,Fastener Spacing or Submit Manufacturers Details that Gauge Thickness: U Comply with RAS 111 and Chapt I er 16.. Slope: oc Anchor/Base Sheet&No.df Ply(s): Gt FT. Anchor/Base eYt Fa ener/Bonding M terial: rj II S�`lco Insulation Base Layer: tl i Y r Base Insultation Size and Thickness: X jt I Rarapet Base Insulation Fas enerjBonding M terial• Height Top Insulationlayer: 'SO,N&Z x a Top Insulation Size and Thickness: � 1t FT. Top Insulation Fastener/Bonding Material: o,'Q I Mean Base Sheet(s)&No.of Ply(s): Roof Base Sheet Fastener/Bonding Material: Height I Ply Sheet(s)'&No.of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: j Top Ply Fastener/Bonding Material: I l