HomeMy WebLinkAboutNotice of Acceptance I
RECEIVED
MIAMI-DADE COUNTY 1
FEB 2 8 2022 PRODUCT CONTROL SECTION
St.Lucle County 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RPWitting Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T I(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Qov/economy
Interwrap,Inc.
32.923 Mission Way REVIEWED FOR
Mission,BC, Canada V2V-6E4 CODE COMPLIANCE FILE COPY
SCOPE: ST. IUC�E COUNlyt �'
This NOA is being issued under the applicable rules and regulations governing Ith e onstruction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
!
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (Iu Miami Dade County) and/or the AHJ (in areas other than Miamii Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply]with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code. j
j
DESCRIPTION: Titanium®UDL-30,Titanium®UDL-50,RhinoRoof U10,RhinoRoof U20,Titanium UDL25
Synthetic Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product;
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure;to comply with any section-
of this NOA shall be cause for termination and removal of NOA..
I
ADVERTISEMENT: The NOA number preceded by.the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official. ;
This NOA renews NOA No. 14-0603.18 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
I I
I
- I
f i .
MIAMI•DADE COUNTY NOA No.: 18-0814.09
� { Expiration Date: 08/08/23
Approval Date: 08/30/18
j Page 1 of 4
i
I
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: Polypropylene
SCOPE:
This acceptance is for,Titanium®UDL-30,Titanium®UDL-50, ,,,,,RhinoRoof U20,Titanium UDL25, and
Synthetic Underlayments as described in this Notice of Acceptance, for use with approved prepared roof assemblies
where ASTM D226 Type underlayment is specified and installed with prescribed approved'fasteners and fastener
densities.Designed to comply with the Florida Building Code including the High Velocity flurricane Zone of the
Florida Building Code
PRODUCT DESCRIPTION:
Test Product
Product Dimensions Specification Description
48"x 250'rolls ASTM D226 Woven sy
Titanium®UDL-30 nthetic polymer underlayment with two
Type I&H sides coate U p d with V rotected and slip resistant
Manufacturing 1
Location #1 polymer s&bilized polypropylene on both sides.
Titanium®UDL-50 48"x 250' rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing Type I&ll sides coated with UV protected and slip resistant
Location#1 polymer stabilized polypropylene on both sides.
RhinoRoof U20 42"x 286' rolls ASTM D226 Woven synthetic polymer underlayment with two
Manufacturing �
Type I and H sides.coated with UV p I rotected and slip resistant
Location #1 polymer stabilized polypropylene on both sides.
rTi
tanium:L�25 � 48"x 250' rolls ASTM D226 Woven syetic polymer underlayment with two
Manufact
17 Type I and H sides coated with UV protected and slip resistant
Location #1 polymer stabilized polypropylene on both sides.
RhinoRoof U10 42"x 286'rolls ASTM D226 Woven synthetic polymer underlayment with two
Type I&II sides coated with UV protected and slip resistant
Manufacturing i
Location #1 polymer stabilized polypropylene on both sides.-
I
MANUFACTURING LOCATIONS:
I I
1. ML2
I
4
I
I
i
I
NOA No.: 18-0814.09
MIAMI•DADECOUNTY Expiration Date: 08/08/23
Approval Date: 08/30/18
j Page 2 of 4
i
i, I
I
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Intertek Testing Services #3031783 TAS 104� .02/19/03
3119607COQ-003B ICC-ES AC48 02/20/08
3124826-01 ASTM E108 02/19/08
3124826MID-007 1 ASTM E168 02/25/08
311801000Q-003 ASTM D226 02/20/08
3130639COQ-002A ASTM D226 02/20/08
3146738COQ-003A ASTM D226 06/20/11
3146738COQ-003B ASTM D 1876/ AS 117 03/28/08
101465036COQ-001 ASTM D19�70 06/27/14
100539395COQ-006 ASTM D226 06/02/14
101863861COQ-OOIA ASTM D226 10/28/14
101823107COQ-011 ASTM D226 12/09/14
Trinity ERD 115010.05.10 ASTM D4798/13226 05/14/10
I38010.08.11 ASTM D226 08/11/11
I35520.08.11 ASTM D2523 /JD1781 08/17/11
INSTALLATION SPECIFICATIONS:
Titanium® UDL-30,. Titanium® UDL-50, RhinoRoof U10, RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments
L Titanium®UDL-30,Titanium®UDL-50,RhinoRoof U10,RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall be installed in strict compliance with applicable Building Code.
2. Titanium@ UDL-30,Titanium@ UDL-50,RhinoRoof U10,RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments shall be installed with a minimum 4-inch head lap in a shingle layer fashion.
3. Titanium@ UDL-30,Titanium®UDL-50,RhinoRoof U10,RhinoRo If U20, and Titanium UDL25 Synthetic
Underlayments shall be fastened with Miami-Dade approved corrosion resistant tin-caps and 12 gauge 1 1/4"
annular ring-shank nails, spaced 6"o.c. at all laps and three staggered,ll rows fastened 12"o.c. in the field of the
roll.
4. Titanium®UDL-30, Titanium@ UDL-50,RhinoRoof U10,RhinoRoof U20, and Titanium UDL25 Synthetic
Underlayments may be used with Asphaltic shingles,Wood shakes and shingles,Non-structural metal roofing,
and quarry slate:Titanium@ UDL-30,Titanium®UDL-50,RhinoRoof U10,RhinoRoof U20, and Titanium
UDL25 Synthetic Underlayments shall not be used as roof tile underlayments.
5. For Roof Tile applications;may be used as an anchor sheet in roof the applications when used in combination
with a top membrane layer,consisting of a Miami-Dade approved TAS 103 self-adhering underlayment. (See
current NOA listing of approved TAS 103 self-adhering underlayment for installation guidelines and
limitations of use).
6: For fire classification of specific roof assemblies using Titanium@.UDL-30, Titanium®UDL-50, RhinoRoof
U10, RhinoRoof U20, and Titanium LDL25 Synthetic.Underlaymelnts refer to a current Approved Roofing
Materials Directory for fire ratings of this product.
I
_ NOA No.:18-0814.09
MIAMI•DADE COUNTY Expiration Date: 08/08/23
Approval Date: 08/30/18
Page 3 of 4 .