Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Notice of Acceptance
i {s E CE}.VED FILE COPY MAR 10 2022 MIAMI•DADE � MIAMI-DADS COUNTY ® ST. Lucie County, ilermitting PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)3I15-2590 F(786)315-2599 NOTICE OF ACCEPTANCE OA wvvw.miamidade.gov/buildine s01 N Industries,t Inc. CODE COMPLIANCE Medley,FL 33166 ST. LUCIE COUNTY BOCC 2Z 03 — 07-97 SCOPE: I This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami-Dade County) and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code.' This product is approved as described herein,and has been designed to comply with th6 Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION:Series"SH-7800(Fin Frame)"Aluminum Single Hung Window—L.M.I. APPROVAL DOCUMENT:Drawing No.L7800-0801,titled"Series-7800 Single Hung Fin Frame Impact Window",sheets 1 through 4 of 4,dated 03/31/08,with revision E dated'07/31/20,prepared by manufacturer,and signed and sealed by Thomas J. Sotos,P.E.,bearing the Miami—Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by,the Miami—Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturers name or logo,city,state,series, and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.18-0911.07 and consists of this page 1 and,evidence pages E-1,E-2,E-3 and E-4,as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. NOA No.20-0813.08 MIAMI•DADE COUNTY Expiration Date: November 06,2023 Approval Date: October 08,2020 10/02/20 Page 1 i v i Lawson Industries,Inc. i NOTICE OF ACCEPTANCE: EVIDENCE SUBAWTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS , 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 08-052Z18) 2. Drawing No L7800-0801,titled"Series-7800 Single Hung Fin Frame Impact Window', sheets 1 through 4 of 4, dated 03/31/08,�th revision D dated 11/01/17, prepared by manufacturer,-signed and sealed by Thomas J. Sotos,P.E. (Submitted under NOA No. 17-1212.18) i B. TESTS j 1. Test reports on: 1)Large Missile Impact,Test per FBC,TAS 20 -94 2) Cyclic Wind Pressure Loading peer FBC, TAS 203-94 along with marked-up drawings and installation diagram of an aluminum single hung fin window,prepared by Hurricane Engineering&Testing,Inc.,,Test Report No. HETI-08-2083, dated 03/14/08, signed and sealed by Candido F.Font,P.E. (Submitted under NOA No. 08-0527.18) 2. Test reports on: 1)Large Missile Impact Test per FBC,TAS 201�-94 2) Cyclic Wind Pressure Loading pei FBC, TAS 203-94 along with marked-up drawings and installation diagram of an aluminum single hung fin window,prepared by Hurricane Engineering&Testing,Inc.,'Test Report No. HETI 08-2084, dated 03/14/08, signed and sealed by Candido F. Font,P.E. (Submitted under NOA No. 08-052ZI8) j 3. Test reports on: 1)Large Missile Impact Test per FBC,TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of an aluminum single hung fin window,prepared by Hurricane Engineering&Testing,Inc.,°Test Report No. HETI 08-2015, dated 01/15/08,signed and sealed by Candido p1.Font,P.E. (Submitted under NOA No. 08-052ZI8) 4. Test reports on: 1)Large Missile Impact Test per FBC,TAS 201�-94 2)Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of an'aluminum single hung tin window,prepared by Hurricane Engineering&Testing,Inc.;Test Report No. IIETI 08-2016, dated 01/15/08, signed and sealed by Candido F.Font,P.E. (Submitted under NOA No. 08-0527.18) � I i i Manuel Peh.13. . j P duet Control Er NOA No.20Expiration Date: November Approv Date: October 08,2020 E-1 i i I I Lawson Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED i 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's(CONTINUED) B. TESTS(CONTINUED) 5. Test reports on: 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,'Loading per FBC, TAS 202-94 3)Water Resistance Test,per FBC, TAS 202-94 4)Forced Entry Test,per FBC 2411 1-3.2.1,and TAS 202-94 along with marked-up drawings and installation diagram of an aluminum single hung fin window,prepared by Hurricane Engineering&Testing,Inc.;Test Report No. IIETI 07-4324, dated 01/15/08, signed and sealed by Candido F.Font,P.E. (Submitted under NOA No. 08-0527.18) 6. Test reports on: 1)Large Missile Impact Test per FBC,TAS 201-94 2)Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of an aluminum single hung fin window,prepared by Hurricane Engineering&Testing,Inc., Test Report No. BETI 07-4325, dated 01/15/08,signed and sealed by Candido F.Font,P.E. (Submitted under NOA No. 08-0527.18) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC, dated 05/16/08 and 07/07/08, prepared by manufacturer,!-signed and sealed by Thomas J. Sotos,P.E. (Submitted under NOA No.12-0127.13) 2. Glazing complies with ASTM E1300-04/09 D. QUALITY ASSURANCE j 1. Miami Dade Department of Regulatory and Economic Resources(RER). ! E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-1114.14 issued to Ku ray America,Ine.for their "Trosifol®Ultraclear,Clear and Color PVB Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 2. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company(MA) for their"Saflez Clear and Color Glass Interlayers"dated 09%07/17, expiring on 05/21/21. I Manuel Perez,P.E. Product Control Ex4wMr NOA No.20413.05/ Expiration Date: November , Approval Date: October 08,2020 E-2 II I� Lawson Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBNIITTED UNDER PREVIOUS NOA's(CONTINUED F. STATEMENTS 1. Statement letter of conformance, complying with FBC Wh Edition (2017) and of no financial interest,issued by manufacturer,dated January 22,2018,signed and sealed by Thomas J. Sotos,P.E. (Submitted under NOA No. 17-1212.18) 2. Statement letter dated 01/22/18 of the editorial drawing changes issued by Lawson Industries,Inc., signed by Nelson Erazo, Senior Design Engineer. (Submitted under NOA No. 17-1212.18) 3. Department of State Certification of LAWSON INDUSTRIES,INC.as a for profit corporation,active and organized under the laws of the State of Florida, dated 04/11/14 and filed at the Secretary of State. (Submitted under NOA No. 14-0908.09) 4. Notification of Successor Engineer for manufacturer,'s NOA document per Section 61G15-27.001 of the Florida Administrative Code;notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to the NOA No. 08-0527.18, dated 02/27/09, signed and sealed by Thomas J. Sotos,P.E. (Submitted under NOA No. 12-012Z13) 5. Laboratory compliance letter for Test Reports No.HETI 08-2083,HETI 08-2084, HETI-08-2015,HETI-08-2016,BETI 07-4324 and HETI-07-4325,all issued by Hurricane Engineering&Testing,Inc., dated from O1/15/08 through 03/14/08, signed and sealed by Candido F. Font,P.E. (Submitted under NOA No. 08-0527.18) 6. Proposal No. 07-2527 issued by the Product Control, dated 03/29/07, signed by Manuel Perez,P.E. (Submitted under NOA No. 08-052ZI8) G. OTHERS 1. Notice of Acceptance No. 17-1212.18, issued to Lawson Industries,Inc. for their Series"SH-7800(Fin Frame)"Aluminum Single Hung Window—L.M.I.,approved on 02/08/18 and expiring on 11/06/18. I' i i I Manuel Peb06, . Product Control Er j NOA No.20 Expiration Date: November Approval Date: October 08,2020 E-3 Lawson Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBAMTED . A. DRAWINGS 1. Drawing No L7800-0801,titled"Series-7800 Single Fin Frame Impact Window", sheets 1 through 4 of 4, dated 03/31/08,with revision E dated 07/31/20, prepared by manufacturer, signed and sealed by Thomas J. Sotos,P.E. B. TESTS 1. None C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 19-0305.02 issued to Kur'aray America,Ina for their "Trosifol®Ultraclear,Clear and Color PVB Glass Interlayers" dated 05/09/19, expiring on 07/08/24. � 2. Notice of Acceptance No. 20-0622.01 issued to Eastman Chemical Company(MA) for their"Saflex PVB Clear and Color Glass Interlayers" dated 08/06/20, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC Th Edition (2020), dated August 03, 2020, issued by the manufacturer, signed and sealed by Thomas J. Sotos, P.E. I G. OTHERS 1. Notice of Acceptance No. 18-0911.07,issued to Lawson Industries,Inc. for their Series"SH-7800(Fin Frame)"Aluminum Single Hung Window—L.M.I.,approved on 10/11/18 and expiring on 11/06/23. i I I ! I Manuel rez,P.E. P Pe roduct Control Er06, r Nl No.20 Expiration Date: November Approval Date: October 08,2020 E-4 I j I I I I 54.371. 51.375' 54.375' WINDOW FIN FRAME WIDTH WINDOW FIN FRAME WIDTH WINDOW FIN FRAME WIDTH C - l4.123' 11.125• 19lZS' O 012 SAS ANCHORS. Il 13/16' r12 SAS.ANCHORS• 012 SAS.ANCHORS 1-0.125' 11.12S'K OqCA)7 PER FRAME HEAD p[, CA)4 PER FRAME HEAD CA)4 PER FRAME READ O CO<B>4 PER FRAME SILL A� CB)4 PER FRAME SILL A 4""* t8I4 PER FRAMELL "*• Co tq r CC)6 PER FRAME JAMB 6' 6, IL>6PER FRAME JAMH� ¢ tG)6 PER FRAME JAMH� 6' A M V1 C>= V 0 c I L I Max. D.L.O.Width 14.500' - 14.250' a 48 I1 16 O o •• O I w 0 II 14250' G II [] � C zo G q t1 p D 11,LSD ° D m 2 a z $ L Max. D.L.O.Width Max. I "• Max. D,L.O. Widths .� ql B �' o as tt is �� �� uzso• � Btt 16 � �C3� 6, �� •Z. � � 14500' ,i xGm O I� 10 C; o 14.500' w �— 41 j N CVJ� o 6 I b 140.125' I--,O.125' I- 40.125' VI kk 52C S2.125• S WINDOW BUCK WIDTH WINDOW BUCK V1DTH WINDOW BUCKUCK WIDTH ✓ (�+ UN-EQUAL LITE RADIUS UN-EQUAL LITE EQUAL LITE A ELEVATION ELEVATION ELEVATION �_z Z SERIES-7800 SINGLE HUNG IMPACT WINDOW — FIN FRAME General Notes: I 4, yyyy 1.) THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY WITH THE E REQUIREMENTS OF THE FLORIDA BUILDING CODE (2017-et.h Edition & 2020-7th Edition) INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ) AND ASTM 1300-98. THIS PRODUCT IS IMPACT RESISTANT. WINDOW INSTALLATION NOTES: 2 IL o 2.) 2 X WOOD BUCKS SHALL BE INSTALLED AND ANCHORED SO THAT THE [XT.GRADE BACK BEDDING N N -----BUILDING-RESISTS-THE-SUPERIMPOSED_LOADS-IN_ACCORDANCE_WITH________—__ B TO HE APPLIED BEHIND I. THE WINDOW OPENING MUST BE PROTECTED WITH A , , , i o - _ _ _- ---VINDGV_FRAME FIN By-- tV REQUIREMENTS OF F.B.C. & TO BE REVIEWED BY BUILDING OFFICIAL INSTALLER tiYPJ CODE APPROVED FELT OR-MOISTURE/WEATHER-BARRIER,- a-WEATHERPROOF APPROX. 12' WIDE THROUGHOUT ENTIRE PERIMETER OF € I 3.) ANCHORS SHOWN ABOVE ARE A3 PER TEST UNITS. ANCHORS ON ALL WINDOW BARRIER J SIZES ARE NOT TO EXCEED THESE MAXIMUM SPACINGS ON CENTER (O.C.). BY DTHERSCTYP.) THE WINDOW MOUNTING FIN. CNOT BY LAWSON INDUSTRIES) s B 3 9 z W 4.) ANCHOR CONDITIONS NOT DESCRIBED IN THESE DRAWING'S ARE TO BE 2, THE WINDOW FRAME FIN TO HE BACK-BEDDED AN EFT, gg GRADE CAULK THROUGHOUT THE ENTIRE PERIMETER OF FIN tI ENGINEERED ON A SITE SPECIFIC BASIS, UNDER SEPARATE APPROVAL AND I BY WINDOW INSTALLER (TYPJ TO BE REVIEWED BY BUILDING OFFICIAL. - 3. THE EXPOSED EXT. PERIMETER OF THE WINDOW'FRAME TO B. WINDOWS ARE QUALIFIED FOR USE WITH SINGLE GLAZE LAMINATED GLASS 4<ir +- BE SEALED W/ AN APPROVED EXTERIOR GRADE CAULK ' a — -- TYPES-TABULATED_HEREIN-(SEE_SHEET_//3). > y >?> i< ,.wr.::; BY OTHERS (TYPJ ` 6.) WINDOWS ARE QUALIFIED FOR USE WITH DOUBLE GLAZE LAMINATED ' y�®��Io INSULATED GLASS TYPES TABULATED HEREIN (SEE SHEET #3). E�4` < <E4« �e 1j 7.) SEE SHEET 3 FOR LOCK DETAILS & OPTIONS. '' 6\'T'�0 PRODUCT REVISED 5••;a.,,y,, DOV FRAME FIN a� C ID N �, BJ SEE SHEET 3 FOR GLAZING DETAILS & OPTIONS AND DESIGN PRESSURES. a oomp(qIng with the Fioride I+u :� N p CiL 9.) WOOD OPENING SHALL BE PROTECTED WITH AN APPROVED MOISTURE Building @ode $� W RESISTANT WEATHERBARRIER (BY OTHERS). PRIOR TO WINDOW INSTALLATION. Noa PIo, 20.0813.08 J =m (SEE SHEET #1 FOR DETAIL) Ex Iretlon Deb 1/08/2023 'LO its O,'C a ' EXT.GRADE PERIMETER .�•. 10.) MATERIALS; INCLUDING BUT NOT LIMITED TO STEEL SCREWS, THAT COME INTO CAULKING NOT BY 9 a i � C; CONTACT WITH OTHER DISSIMILAR MATERIALS SNAIL MEET THE REQUIREMENTS LA SON WDUSTRIES•, ©y1 F � OF FLORIDA BUILDING CODE. stucco OR EXTERIOR TO APPLIED BY OTHERS Mlxm ede Produef Co rol p + �~� 11.) EXT. & INT. FALSE COLONIAL MUNTINS ARE OPTIONAL & AND ARE APPLIED W/ SILICONE FINISH BY OTHERS(TYPJ a . ^r•t"•'l�U� WINDOW INSTALLATION DETAIL A EXPOSED WINDOW FRAME FIN TO [ - i ), NOTE; r HE PROTECTED WITH AN APPROVED Ey C (Nw aemd (mM. sm.) MOISTURE/WEATHER BARRIER TIP. m. ALL ANCHORS TO BE #12 SMS OR WD. SCREW THROUGHOUT ENTIRE PERIMETER OF FIN �.• - WITH A MINIMUM OF 1 1/2' PENETRATION INTO c o CY o .;y;C;,: #. N12 SMS or WS W/ �Yf:,: �`� B32 SMS or WS W/ ism C y r� 0Y OTHERS(TYP.) .,.�,•. 1 1/2'MIN.WOOD EMBEDMENT(TYP.) " ?� d 1 1/2'MIN.WOOD EMBEDMENT(TYP.) WOOD. ( REFER TO WINDOW ELEVATIONS ON to m A ;t.7, '`�`'`• ;���x. SHEET 1 FOR MAX, ALLOWABLE ANCHOR SPACING) ALL WOOD FRAMINGf`t xy�W ALL WOOD FRAMING 1 ENGINEERED SEPARATELY ..5'q Tz ENGINEERED SEPARATELY a WHEN THE GAP BETWEEN THE WINDOW FRAME AND N p Qs p _ 6 TO BE REVIEWED ';�%�'+; 6 TO BE REVIEWED BLDG.OFFICIAL(TYP.) �? BLDG.OFFICIAL(TYPJ THE BUCK IS LESS THAN 1/8°, SHIMS ARE NOT m C C C N ^va• REQUIRED. •it is' %��.�;Y loin) ji .�4.��w� (owl �4 v ~ ''L l/4•Max.GAP ° ' w o� 1 i SHIM SPACE AL 1/4'MAX. 0, A (TYP.) RADIUS HEAD i SHIM SPACE m o � o HEAD 8 17 ' a c 1 ! 19 2 i ,9 U �y U N 9 12 SMS or WS W/ Cy ®~1 1/2 MIN.WOOD EMBED 2 BY 4 MIN. 7 y Qz SEE ELEVATION FOR O (n d LAMINATED GLASS FASTENER SPACING W000 BUCK �f C 4 U cf) 15 ;MATED GLASS W a C 9 1B CLEAR SILICONE ADHESIVE 4 N BEDDING COMPOUND 1/4'SHIM GAP p„1,,, a,e; SHIM SPACE (mMJ E'1 INTERIOR (TYP.) �Y: V7 $ 0 � g t9 P,le al A (n MS )1 EXTERIOR INTERIORas»+zw.>»+ w rrrtwrrw+ ? 25 l 12 ]1 12 GLAZING SEALANT } i»�'•>»a -_"" _`"" """ {� � ti 2, ' o E%POSED-WINDOW-FRAME-FIN-TO B _JAMB— r n' B - - BE PROTECTED WITH AN APPROVED —-O-— - --—- - MOISTURE/WEATHER BARRIER JAMB EXTERIOR GRADE E THROUGHOUT ENTIRE PERIMETER OF FIN PERIMETER CAULKING (TYP.) 1/8, BY OTHERS<TYP $ 9 3 9 Z w 25 WINDOW FRAME WIDTH O 17 14 5 F E WINDOW FRAMEME FIN WIDTH ru d d W p (MAX.) SILL. ::a.,•, 1/4'MAX GAP Y+'•ii SHIM SPACE �. C 'fr I cTYPa PRODUCT REVISED s•,�, ',,.•11r'., eoeo %InpwiththeFlorida ::,'�) [v O EXTERIOR GRADE '�+„+• ' 2 BY 4 MIN. Eullding o • <N ('� PERIMETER CAULKING "l,j WOOD BUCK NOA-No. 20�OB73.OB ,1 Sw - y Ex Iretlon Dalej41L99L20 3 .I Ni '�+ F+ Mlem •Produof^Co rol s �y '*r„„ri e d`•h,:1r 12 S 1 MI. O O W/ SEE ELEVATION FOR EMBED (u /////�Y(•,�i Nl�E418ID.) C q 7800 FIN IMPACT SINGLE HUNG WINDOW-EQUAL LITE 7800 FIN IMPACT SINGLE HUNG-VIEW WINDOW 26 y WINDOW Glass Glass Glass Glass Glass WINDOW Glass Glass Glass Glass Glass o C DIMENSIONS Type"1" Type"2" Type"3" Type"4" Type"5" DIMENSIONS Type"1" Type"2" Type"3" Type"4" Type"S' z CODE Width Hel ht P+! P+l• P+/- p+/- p+/- CODE.....__Width ,_Height__P(+/1.-.._P(+!_).....-.._P(t!-)... P(+l L...._P(*L)_ G7 r� -- ---9..--. _(..-)..._..(._-..).... (._.-).... .. .(__._) -.(._.)-... SIZE in in s s s s SIZE in In s s s s s 12 18.125 25 60 60 46 46 60 14-2 18.125 1 49.625 60 60 46 46 60 y o U to c 14-3 18,125 49.625 60 60 46 46 60 13 18.125 37.375 60 60 46 46 60 5 a 15-3 18.125 62 60 60 46 48 60 2 0 � 14 18.125 49.625 60 60 46 46 60 3 y , o 15-4 18.125 82 60 60 46 48 60 14-5 18.125 57,125 60 60 48 46 60 Z� o O W`k Exi 16-4 18.125 73.25 60 60 46 46 60 15 18.125 62 60 60 46 46 60 16-45 18.125 73.25 60 60 46 46 60 6 6 o w x 16 18.125 73.25 60 60 46 46 60 16-5 18.125 73.25 60 60 46 46 60 a to 9 b m H32 25.5 25 60 60 46 46 60 A 46 46 60 � o H34-2 25.5 49.625 60 60 z i H33 25.5 37.375 60 60 46 46 60 H34-3 25.5 49,625 60 60 46 46 60 r MT 0 H34 25.5 49.625 60 60 46 46 60 H35-3 25.5 62 60 60 46 48 60 25 21 0 0la a H34-5 25.5 57.125 60 60 46 46 60 H35-4 25.5 62 80 60 46 46 60 z H35 25.5 82 60 60 46 46 60 H36-4 25.5 73,25 80 80 46 48 60 H36 25.5 73.25 60 60 46 46 60 H36-45 25.5 73.25 60 60 46 46 6017 ;:) z 22 36 25 60 60 46 46 60 H38-5 25.5 73.25 60 80 46 48 60 LOCK (LATCH AND SWEEP) OPTIONS ®~ ' 23 36 37.375 60 60 46 46 60 24-2 36 49.625 80 60 46 48 60 1. BOTH EXTRUDED ALUMINUM AND.PLASTIC LIFT rs Z 24 36 49,625 60 60 46 46 60 24-3 36 49.625 60 60 46 46 60 HANDLE LOCKS ARE QUALIFIED FOR USE ON 24-5 36 57.125 60 60 46 46 60 25-3 36 62 60 60 46 46 60 ALL WINDOWS. W C4 25 36 62 60 60 46 46 60 25-4 36 62 60 60 46 46 60 2, BOTH DIE CAST AND NYLON CAN SACKS ARE N A. 28-4 36 73.25 80 60 48 46 g0 QUALIFIED FOR USE ON ALL WINDOWS. a tj 26 36 73.25 60 60 46 46 60 (i 11 z 3. ONLY TWO (2) LOCKS ARE REQUIRED PER EACH 26-45 36 73.25 60 60 46 46 60 VENT. W Tn 32 52.125 25 60 60 46 46 60 26-5 36 73.25 80 60 48 48 60 33 52.125 37.375 60 60 46 46 60 34-2 52.125 49.625 60 60 46 46 60 A W a 34 52.125 49.625 60 60 46 46 60 z Tn t 34-3 52,125 49.825 80 80 46 48 ' 60 34-5 52.125 57.125 60 60 46 46 60 35-3 52.125 62 60 60 48 46 60 ~ 35 52.125 62 60 60 46 46 1 60 35-4 52.125 62 60 60 1 46 46 60 36 1 52.125 1 73.25 1 60 1 60 46 1 46 1 60 36-4 1 52.125 73.25 80 60 46 46 60 g $ Note- (a) WINDOWS WITH GLASS TYPES '4 & 5' INSTALLED ABOVE 36-45 52.125 73,25 80 60 46 48 60 30FT.IN THE HVHZ, THE I,G. EXTERIOR LITE SHALL BE TEMPERED. 36-5 52,125 73.25 60 60 1 46 46 1 60 9 S G4 17 20 (M) 0125' ANN & HS. GLASS (OUTBOARD) S 11 G1 G2 03 (NOT QUALIFIED FOR SMALL MISSILE IMPACT) ------------- - - --- ---- ----- (xx)-0125'-TEMPERED-GL-ASS-<OUT-BOARD) =- ---------------- -_---- -- ------- -A- - - -o ------' --- - -- - - - -- - - - - - -(QUALIFIED FOR SMALL MISSILE IMPACT) E G4 OboO•-�- GS o.606•-{- 8 9 S 9 z z W GLAMUG DEPTH 23 GLARING DEPTH 3 .gg .q@ INSULATED NATED GLASS COMPOSITION e 4 x 6 C �4� LAMINATED GLASS COMPOSITION - e 1, & e 2 y3 19[M GLASS DESCRIPTION DIiTA1L LAI@IATE 089CRa7TON 01 r= GLASS DESCRIPTION DETAIL- IAMINATE DESCRIPTION of Is c 0 p 1 1/8•HCAT-STRENGHTENED GLASS '- 1-iRDSIP➢L PVB 1 1/0'ANNEALED GLASS tot,0-) .-, _, 33 $$ --- - _ __ ---e-0.090•-PLASTIC-INTERLAYER -`_ - �,�.__ _ -- T 13 A: iq 009G'PLASTIC INTERIAYER �P :.. or �- CAPLEX PVB by, S 1/8'HEAT-STRENGHTENED GLASS 1 Ww 2-SAfLE%PVB 3 1/8•ANNEALED GLASS - _ 1T Enstnnn Chenkal Ca, ", J A 1/4'INSULATED AIR SPACE - y{- 4 t •' • °~^ efJ'r. S 1/8'ANNEALED GLASS J �•' PRODUCT REVISED LAMINATED GLASS COMPOSITION - e 3 OeOom I Iny wkh The Florida ° u o�.l IPEM O1A99 DESCBIPTON DB1Ad LAMINATE DESCRIPTION INSULATED LAMINATED CIA33 COMPOSITION e 5 P Y d ) J. BYllding 6O o ° 4I l VS'ANNEALED GLASS ITIDr GLASS DESCRIPTION D1iTAR IAL@)AT8 D65CR1Pt10N NOA-No. 20-0813.08 u;: T .! i! 0.090•PLASTIC INTER! m 1 SArLEE PVB I., I L/8•MEAT-STRENGHTENED GLASS _ 1 BN IrIRIOn D041 /Q16; D 3 l` C� v J Esstnnn ChaNcol Co. U 3 VS'ANNEALED GLASS ANa• a OA90•PLASTIC INTERLAYER © 3 1/8•HEAT-STRENGHTENED GLASS TRDSIrOL PVB by. By O fti + Nuroroy Anerl-Inc. /,•. Laamina a Ines & Option 4 4 1/4'INSULATED AIR SPACE WIu MIOm OdO PEOdYO�CO r01 ° tly ia._T/� D 1/8•HEAT-STRENGHTENED GLASS W 1) Trosi(ol PVB by: Kuraray America Inc. 1>. '4//I•;�'.�l�'at'�, ® 2) Satlex PVB by: Eastman Chemical Company GLAZING DETAILS OPTIONS AND DESCRIPTION A OFRAME HEAD FIXED MEETING RAIL BILL OF MATERIALS L-7801 L-7704 O I1094—I O � ITEM JJ PART Ip R•EgD, DESCRIPTION REMARKS q� 1 L-7801 I FIN FRAME HEAD 6063-T6 ALUMINUM e$ c Z 1'Ijg ——062 I FRAME TOP CORNER 2 L-7802 I FIN FRAME SILL 6063-T6 ALUMINUM GO A L 1 q Y A62 3 L-7803 2 FIN FRAME JAMB 6063-T6 ALUMINUM Nn a .1 E '7 F. o7a— — z2es 4 L-7704 1 FRAME FIXED MEETING RAIL6063-T6 ALUMINUM c .• a 844 5 L-7705 1 VENT MEETING (TOP) RAIL 6063-T6 ALUMINUM 3 4 M P. J 5046 L-7706 1 VENT BOTTOM (LATCH) RAI 6063-T6 ALUMINUM 7 L-7707 2 VENT JAMB (SIDE) RAIL 6063-T6 ALUMINUM 2.6s1 8 L-7708 AS REO'D. GLAZING BEAD ( 3/8' ) 6063-TS ALUMINUM ulO FRAME HEAD 9 FS-006 AS REO'D. FRAME ASSEMBLY SCREWS 09 X 3/4' P•H. PHILLIPS 'b o L-7� 51LL 802 L-RAME 603J� 10 FS-040 AS REOD• INSTALLATION SCREWS #12 X 1 1/4' F.N./PHIL• o 11 L-7531 AS REO'D. BULB VINYL WTS'P 1/4' DIA. BULB #3033 a ^1.4a rnAME.AMR 12 1 PWS-003 JAS REO'D• FIN SEAL WEATHERSTRIP .187'x•230' Q 13 PWS-005 AS REO'D. FIN SEAL WEATHERSTRIP 187'x•350' U o 2.437 14 PWS-009 AS REO'D. FIN SEAL WEATHERSTRIP 187'x.310' ®,Z I 15 HC-024-1 2 SELF ADHESIVE PILE PAD 1/4' X 1 1/2' ~ 16 L-7711 AS REO'D. GLAZING BEAD 6063-T5 ALUMINUM Y cr Z 062� 2.643 17 L-4204 AS REO'D• GLAZING BEAD 6063-T5 ALUMINUM w o Q 18 L-7723 1 SASH BALANCE CAM/GUIDE (2 X VENT) a O •062 1.125 462 19 L-7725 2 RIGID VINYL SASH STOP (2 CC FRAME) r- g 20 L-7727 2 BLOCK 6 TACKLE BALANCE BSI Balance Systems ((f rA r.- � � 21 L-7539 2 VENT EXTRUDED LATCH (2 X VENT) 2.713 --1.129-- I--•781-- f--[91 22 L-7523 2 VENT LATCH SPRING (1 x LATCH) Q w ca , VENT INTERLOCK RAIL VENT BOTTOM RAIL VENT JAMB RAIL O FRAME S 23 SM-5731 AS REO'D• GLAZING SILICONE SM-5731 Zi IL K L-7705 L-7706 L-7707 24 r 2 Laminated Glass SEE GLAZING DETAILS OO ] FRAME BOTTOM CORNER 25 HC-057-1 2 VENT MOLDED LATCH MOLDED NYLON O 26 IHC-058-11 2 VENT SWEEP LATCH MOOED NYLON 27 a 2 FRAME SILL FOAM GASKET SELF ADHESIVE � s 1.373--- VENT TOP CORNER 28 HC-026-1 1 SCREEN FRAME 4 MESH O l 29 L-7730 1 PRODUCT LABEL o a n a i - o6a ' 9 30 M 2 Assembly Jolnt Gasket AT FRAME SILL � 2.062 2.000 ,062 SM- - n e N 31 5504 AS REO'D• JOINT SEALANT SM 5504 f0Q °6z el 32 ■ AS REO'D• PERIMETER ACRYLIC CAULK OSI POLYSEAMSEAL B YFuT Jaue A$$$3 9 c$$9� —L075--I 1235-- VEM TOP RAIL V p 1686W VENT SPRING LATCH GLAZING BEAD GLAZING BEAD GLAZING BEAD -- — -- - °' ....r''' L-7539 L-7708 L-7711 � L-4204 , PRODUCT REVISED m o `•;. 6 .062 8 O Bulldlnp on:with the Florida II NOA-No. 20.Ot113.OB a w `�;•(�' O 1050 Expiration Dote 1/06/2023 ASO VENT BOTTOM RAIL em omp 1'01� .391 VENT TTOM CORNER ,'.'. Mlem4ade Produo" rol .115� S ,fir t! �+•'�, eti.. —�I ,692 I�773�I •773-� •466 FRAME & SASH CORNER DETAILS A