Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJ-69376 - Hale Residence Sealed
Castillo Engineering HALE RESIDENCE SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES,LLC 10.260 kW PV SYSTEM 620 N.SUITE 250 WYMORE ROAD, SUITE 50, MAITLAND,FL 32751 TEL:(407)289-2575 ERMOCRATES E.CASTILLO-FL PE 52590 5503 RAI NTRE E TRAIL, COPYRIGHTED By CASTILLO ENGINEERING FORT PIERCE, FL 34982 SREVISONSLC DESCRIPTION DATE REV PROJECT DESCRIPTION: CODES AND STANDARDS OWNER HOUSE PHOTO PROJECT INSTALLER 27x38GOVERNING CODES: HALE, JAMES r ' ROOF O NEON: L SOLAR PHOTOVOLTAIC VOLT MODULES FLORIDA RESIDENTIAL CODE,7TH EDITION 2020(FRC) x _ S U N P R ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES : FLORIDA PLUMBING CODE,7TH EDITION 2020(FPC) ■ � �j PROJECT SITES FLORIDA BUILDING CODE, 7TH EDITION 2020(FBC) INSTALLER SYSTEM SIZE: 10.260 kW DC STC FLORIDA MECHANICAL CODE, 7TH EDITION 2020(FMC) Digitally ooE-cash"", ARRAY AREA#1: 136.52 SQ. FT. NATIONAL ELECTRICAL CODE 2017(NEC) gnaiare ARRAY AREA#2: 273.05 SQ. FT. ASCE 7-16 SUNPRO SOLAR `= Ermocrate ARRAY AREA#3: 117.02 SQ. FT. FLORIDA FIRE PREVENTION CODE,7TH EDITION 2020(FFPC) 4492 Eagle Falls Place, ��. STATE OFF S E '"'�S`OR•OP G2,, Castillo Tampa, FL 33619 EQUIPMENT SUMMARY (866) 450-1012 Date: 22.03.0 27 LG NEON: LG380N1C-A6(380W)MODULES _m.,,�., 2 15:35:5 ��••'•'����•�� 2 15:35:52 27 ENPHASE: IQ7PLUS-72-2-US MICROINVERTERS ENGINEER E '} RACKING: UNIRAC LIGHT RAIL - - PROJECT NAME ATTACHMENT:S-5-N CLAMPS Castillo Engineering Services LLC ' ATTACHMENT:ABASE LOW SLOPE MOUNT 620 N. Wymore Road, Suite 250, Maitland, FL 32751 TEL: (407)289-2575 ` P, . N DESIGN CRITERIA: Ermocrates E. Castillo * w _j 00 WIND SPEED(ULT): 170 MPH License#: FL PE 52590 �s 0 WIND SPEED(ASD): 132 MPH i Z RISK CATEGORY: II SHEET INDEX �" LU W Lill J EXPOSURE: C 0 LU VICINITY MAP - C)f LU SHEET# SHEET DESCRIPTION W Z Q G-01 COVER SHEET � LU A-00 NOTES AND DESCRIPTION PROJECT SITE W Q o 0 A-01 ROOF PLAN = � Q S-01 MODULE LAYOUT LL S-01.1 PARTIAL PRESSURE AND MODULES EXPOSURE 71 STRUCTURAL CERTIFICATION: ELECTRICAL CERTIFICATION: S-02-02.1 ATTACHMENT DETAIL SHEET NAME S-02.2-02.4 STRUCTURE CALCULATION COVER SHEET I ERMOCRATES CASTILLO PE#52590 AN ENGINEER I ERMOCRATES CASTILLO PE#52590 AN ENGINEER E-01 ELECTRICAL LINE DIAGRAM 5503 F.ar1tr2e-•ail Fon LICENSED PURSUANT TO CHAPTER 471, CERTIFY LICENSED PURSUANT TO CHAPTER 471, CERTIFY E 02 WIRING CALCULATIONS "-`- FL 34e8Z, SA THAT THE INSTALLATION OF THE MODULES IS IN THAT THE PV ELECTRICAL SYSTEM AND `s,ales SHEET SIZE COMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED., ELECTRICAL COMPONENTS ARE DESIGNED AND E-03 SYSTEM LABELING ANSI B CHAPTER 3. BUILDING STRUCTURE WILL SAFELY APPROVED USING THE STANDARDS CONTAINED IN DS 01-12 DATA SHEETS ACCOMMODATE WIND LATERAL AND UPLIFT THE MOST RECENT VERSION OF THE FLORIDA 1111 X 17" FORCES, AND EQUIPMENT DEAD LOADS. BUILDING CODE. FBC 107, THE NEC 2017, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY SHEET NUMBER CENTER CERTIFICATION. & G-01 Symbols: Abbreviations: System Description Castillo SOLAR DONE RIGHT® -Sheet where AC Alternating Current This system is a grid-tied, PV system, with PV generation consisting of CASTILLOENGINEERING Section.............. section is located 27x380 LG NEON: LG380N1 C-A6 (380W) Modules with a combined STC rated do sER OACES5LLC X-XX ACD AC Disconnect 620N.WYMOREROAD, output power of 10,260W. The modules are connected into 27 ENPHASE: SUITE 250, X Deta i l l D Lette r APPROX A p MAITLAND,FL 32751 Approximate IQ7PLUS-72-2-US Microinverters. The inverter has electronic maximum power TEL:(407)289-2575 Elevation........... —Sheet where ERMOCRATES E.CASTILLO-FL PE 52590 x-xx section is located AWG American Wire Gauge point tracking to maximize energy captured by the PV modules. The inverter also COPYRIGHTED BY has an internal round fault detection and interruption device that is set to CASSERVITILLO ES LL RING Detail ID Letter CB Combiner Box g p SERVICES,LLC Detail................ X Sheet where disconnect the array in the event that a ground fault that exceeds one ampere REVISIONS x-xx section is located DC Direct Current should occur. The inverter has DC and AC disconnect integrated system and labels DESCRIPTION DATE REV Detail ID Letter provided required b the National Electrical Code. (Enlarged Plan).. Detail........ .. X Area to be enlarged DISC Disconnect are p rov as re q y x-xx -Sheet where (E) Existing When the sun is shining, power from the PV array is fed into the inverter, section is located 1 Keyed note designation Keyed Notes.......... EL Elevation where it is converted from DC to AC. The inverter output is then used to PROJECT INSTALLER on applicable sheet EQ Equal contribute to the power requirements of the occupancy. If PV power meets the requirements of the loads of the occupancy, any remaining PV power is sold back _ Ground Terminal..... GP Generation Panel to the utility. When utility power is available, but PV power is not available, UNIPR � JB Junction Box building loads are supplied by the utility. Grounding Point/rod.... '�AST;4-,,, Digitally MCB Main Combiner Box �:"G 52 PV Modules ....... *:� no.ez���a�l%e wi al �rmocrat Junction ° sAt sE MFR Manufacturer Solar Panel....... or DD Microinverters O S,o E Castillo Module with Source Circuit number MID Micro rid Interconnect Device Point of Date: g Box Utility : „a 2022.03.0 Combiner Box.......... CB MIN Minimum Connection 215:35:5 MISC Miscellaneous Figure 1: PV System Block Diagram Utility Meter PROJECT NAME AC Disconnect.......... ACD MDP Main Distribution Panel (N) New The inverter meets the requirements of IEEE 1547 and UL 1741. N Main Distribution W J op Panel ...................... MDP NAVD North American Vertical datum U < m FALL PROTECTION: z I— OCPD OverCurrent Protection Device ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENT W W LL Fuse �� MUST BE INDEPENDENT OF ANY ANCHORAGE BEING USED TO SUPPORT OR �_ W W POCC Point Of Common Coupling SUSPEND PLATFORMS, AND CAPABLE OF SUPPORTING AT LEAST 5,000 POUNDS W U PER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS: W Z IY Overcurrent Breaker PV Photovoltaic • AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICH 0� Q W MAINTAINS A SAFETY FACTOR OF AT LEAST TWO. W IY 0- SF Squarefoot/feet • UNDER THE SUPERVISION OF A QUALIFIED PERSON Q CO O Inverter.................... STC Standard Test Conditions ADDITIONAL INFORMATION = LO ILL. • 29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD. Transformer............. SD Soladeck • 1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES TBD To Be Determined ••• 1926.502(D)(15) Automatic............... AT$ " SHEET NAME Transfer Switch 41.0 TYP Typical � � NOTES AND Vent,Attic fan DESCRIPTION (Roof obstruction) UNO Unless Noted Otherwise ALLOWABLE/DESIGN PRESSURE PSF LO DOWN PRESSURE 126 PV Roof Attachment SHEET SIZE UM Utility Meter RAILS IN THIS � UPLIFT PRESSURE, 2 RAILS 89 Trusses POSITION UNO ANSI B Conduit VIF Verify In Field UPLIFT PRESSURE, 3 RAILS 126 1111 X 17" Fire Access WP Weather Proof LG NEON: SHEET NUMBER LG380N1C-A6 (380W) MODULES A-00 N 1241-1011 Castillo - - - - - - - - - - - - - - - - - - Engineering W E SOLAR DONE RIGHT® CASTILLO ENGINEERING (N)SOLADECK I SERVICES, LLC S COA#28345 620 N.WYMORE ROAD, 11. IMC, RMC, FMC, LFMC, SUITE 250, EMT OR EQUIVALENT I M TELAND,FL 3 TEL(407)289-257575 CONDUIT RUN ERMOCRATES E.CASTILLO-FL PE 52590 FIRE ACCESS AND PATHWAYS COPYRIGHTED BY AS PER NFPA 1, 11.12.2 CASTILLO ENGINEERING SERVICES,LLC ROOF#1 REVISIONS (07)LG NEON: LG380N1C-A6 EXISTING (380W) MODULES DESCRIPTION DATE REV DRIVEWAY o ♦ ^ ' ♦ PROJECT INSTALLER 6`� ♦ (E)SERVICE POINT AND UTILITY METERING ♦ ���� v� ♦ ♦ \ (E) MAIN SERVICE DISCONNECT/ I 5 U N P R . ♦ �4�1 �e ♦ ♦ aQ MAIN DISTRIBUTION PANEL N)ALTERNATIVE POWER SOURCE 4' g y ( o ♦ ♦ o•E cash"• Digitally ♦ �� qQO ce AC DISCONNECT/RAPID SHUTDOWN /�1 1 *. nn.*zs igna§re Ermocrate ♦ vP ♦ ♦ / v 9••, STATE J� C E O•.,,, fy.: — (N) ENPHASE IQ COMBINER BOX ''�S..NAt Castillo _ I ♦ ♦ I Date: c;` ♦ ♦ ♦ I Z se 2022.03.0 / 3 ♦ — �,�.,,,_m.„�..oao 2 15:35:53 /n1�S ♦ QjP ; PROJECT NAME .7 Fr ♦ rn o rn y & lliy ROOF#3 04 (06)LG NEON: LG380N1C-A6 w —1 rn (380W)MODULES �� I U Q > z (N)(27) ENPHASE: IQ7PLUS-72-2-US F— Q WL.L MICROINVERTERS _ � W DK ROOF#2 cn � ` 4 w z � uj (14)LG NEON: LG380N1C-A6 < �J (380W) MODULES �I w J co Q U-) O _ LO IL SHEET NAME ROOF PLAN SHEET SIZE 1241-1011 ANSI B - FIRE SETBACK-3 FT 11 II X 17" 1 ROOF PLAN WITH FIRE SETBACKS SHEET NUMBER A-01 AND PROPERTY LINES SCALE: 3/32"= V-0° -ZONING SETBACK-2FT A-01 MODULE TYPE, DIMENSIONS & WEIGHT ARRAY AREA & ROOF AREA CALC'S GENERAL INSTALLATION PLAN NOTES: Castillo mk NUMBER OF MODULES=27 MODULES ROOF Engineering MODULE TYPE = LG NEON: LG380N1C-A6(380W) MODULES ARRAY ROOF AREA TRUSS SEAM 1) ROOF ATTACHMENTS TO METAL SEAMS SHALL BE INSTALLED AS SOLAR DONE RIGHT® MODULE WEIGHT=41.01 LBS/ 18.6 KG. ROOF ROOF TYPE AREA AREA COVERED TILT AZIMUTH SHOWN IN SHEET S-02-S-02.1 AND AS FOLLOWS FOR EACH WIND ZONE: MODULE DIMENSIONS =68.5"x 41.0"= 19.50 SF (sq.Ft.) (Sq.Ft.) BY ARRAY SIZE SPACING FOR 18.4°TILT: CAS ENGINEERING SEE UNIT WEIGHT OF ARRAY=2.10 PSF N SERVICES,LLC COA#28345 #1 METAL 136.52 476.18 28.67 18.4° 306° 2"X4" 16"O.C. 620 N.WYMORE ROAD, N NON-EXPOSED MODULES EDGE/EXPOSED MODULES SUITE 250, #2 METAL 273.05 528.60 86.15 39.8° 126° 2"X4" 16"O.C. WIND MAITLAND,FL 32751 TEL:(407)289-2575 #3 FLAT 117.02 316.96 36•92 4.8° 126° 2"X4" 24"O.C. ZONES ERMOCRATES E.CASTILLO-FL PE 52590 w $ ROOF#1 SPAN CANTILEVER SPAN CANTILEVER COPYRIGHTED BY (07)LG NEON: LG380N1C-A6 CASTILLO ENGINEERING (380W) MODULES ZONE 1 2'-8" 0'- 11" 1'-4" 0'-5" SERVICES,LLC REVISIONS S ZONE 1' X X X X (N) UNIRAC LIGHT RAIL ROOF#2 DESCRIPTION DATE REV (14)LG NEON: LG380N 1 C-A6 ZONE 2e 2'-8" -- ill, 1 -4" 0 -5 (380W) MODULES ZONE 2n 1'-4" 0'-5" 1'-4" 0'-5" (88) PV ROOF ATTACHMENT ���v��� ZONE 2r 1'-4" 0'-5" 1'-4" 0'-5" @ 16"&32"O.C. MAX. V� ��� (N) (27) ENPHASE: IQ7PLUS-72-2-US ZONE 3e 1'-4" 0'-5" 1'-4" 0'-5" (SEE SHEET S-02 FOR MICROINVERTERS ZONE 3r 1'-4" 0'-5" N/A N/A PROJECT INSTALLER ATTACHMENT DETAIL) FOR 39.8°TILT: (SEE SHEET S-01.1 FOR PARTIAL Q PRESSURE OF THE MODULE) NON-EXPOSED MODULES EDGE/EXPOSED MODULES U N P 21 "''9 WIND c �26/ ZONES SPAN CANTILEVER SPAN CANTILEVER '�AST;4 Digitally �c ho.52 I8t$8 Wl rmocrat ZONE1 2'-8" 0'- 11" 1'-4" 0'-5" s., <� ZONE 1' X X X X =0•.<< ° = s E 9, STATE OF :�/' Castillo ZONE 2e 2'-8" 0'- 11" V-4" 0'-5" `S°" °^ Date: ZONE 2n 2'-8" 0'- 11" 1'-4" 2022.03.0 7,9 ZONE 2r 2'-8" 0'- 11' 1'-4" 0'-5" �) 2 15:35:5 1106° ZONE3e 1'-4" 0'-5" V-4" 0'-5" ZONE 3r 2'-8" 0'- 11" 2'-8" 0'- 111, PROJECT NAME FOR 4.8°TILT: ,� - ��-��� NON-EXPOSED MODULES EDGE EXPOSED MODULES N Y�p � 17 �� WIND W J 00 ZONES U Q � SPAN CANTILEVER SPAN CANTILEVER z c') wLL J ZONE 1 4'-0" 1'-4" 2'-0" 0'-8" W 0A_3 ZONE 1' 4'-0" V-4" 4'-0" V-4" (n I_ W U 28/ ZONE2 4'-0" 1'-4" 2'-0" 0'-8" W z W ^ 's ZONE3 2'-0" 0'-8" 2'-0" 0'-8" ^^^^^^ SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS. w M 2) EXISTING RESIDENTIAL BUILDING IS A METAL ROOF & A FLAT ROOF = LO LL WITH A MEAN ROOF HEIGHT OF 15 FT AND SYP 2"X4" ROOF TRUSSES ROOF#3 SPACED 16" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEM 06 LG NEON: LG380N1C-A6 ( ) RETROFIT IS 18.4, 39.8 &4.8 DEGREES. CONTRACTOR TO FIELD VERIFY (380W)MODULES AND SHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD CONDITIONS. SHEET NAME LEGEND 3) FIRE SETBACK TO BE 3' FROM RIDGES AND EDGES, AND 18" EACH MODULE LAYOUT LEGEND F J - WIND ZONE 1 (TYP) WAY FROM HIPS AND VALLEYS PER NFPA 1, 11.12.2. - WIND ZONE 1 (TYP) - WIND ZONE 2e (TYP) 4) THE EXISTING ROOF AND STRUCTURE WILL NOT BE ADVERSELY SHEET SIZE AFFECTED DUE TO THE ADDITIONAL LOADS IMPOSED BY THE SOLAR ANSI B - WIND ZONE 1' (TYP) �— - WIND ZONE 2n (TYP) SYSTEM. �" X 71I - WIND ZONE 2r(TYP) I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN 1 MODULE LAYOUT - WIND ZONE 2 (TYP) _ WIND ZONE 3r(TYP) COMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED. CHAPTER 3. SHEET NUMBER S-01 SCALE: 1/8"= V-0" LLLLLLLLLLL - WIND ZONE 3 (TYP) LLLLLLLLLLL - WIND ZONE 3e (TYP) BUILDING STRUCTURE WILL SAFELY ACCOMMODATE WIND LATERAL S-O AND UPLIFT FORCES AND EQUIPMENT DEAD LOADS. N FOR NON-EXPOSED MODULES (FOR 4.8°) FOR NON-EXPOSED MODULES (FOR 18.4°) Castillo(p 1 1' 2 3 1 1 1 1' 1 2e 2n 2r 3e 3r Engineering%zo!JJ W $ SOLAR DONE RIGHT® 38.5 16 50.9 67.3 48.2 0 48.2 60.5 60.5 60.5 71.3 CASTILLO ENGINEERING Module Size 19.5 Sq.ft. SERVICES,LLC s COA#28345 Module Size 19.5 Sq. ft. 620 N.WYMORE ROAD, Non-Exposed modules Partial SUITE250, MAITLAND,FL 32751 1 1' 2e 2n 2r 3e 3r Pressure TEL:(407)289-2575 Non-Exposed modules Partial P1 15.35 0 0 0 4.15 0 0 50.82 ERMOCRATES E.CASTILLO-FL PE 52590 1 1' 2 3 Pressure P2 14.73 0 0 0.61 1 3.98 0 0.18 51.31 COPYRIGHTED BY CASTILLO ENGINEERING Ps 0 0 19.50 0 50.90 FOR NON-EXPOSED MODULES (FOR 39.8°) SERVICES,LLC 1 1' 2e 2n 2r 3e 3r REVISIONS \> V / DESCRIPTION DATE REV 37 0 37 42.9 37 52.1 1 29.7 T Module Size 19.5 Sq.ft. Non-Exposed modules Partial ROOF#2 1 1' 2e 2n 2r 3e 3r Pressure P3 11.48 0 0 0.49 7.22 0 0.30 37.04 PROJECT INSTALLER (14)LG NEON: LG380N1C-A6 (380W) MODULES P4 11.96 0 0 0 7.54 0 0 37.00 ROOF#1 P5 19.50 0 0 0.00 0 0 0 37.00 (07) LG NEON: LG380N1C-A6 P6 18.71 0 0 0.79 0 0 0 37.24 (380W) MODULES FOR EXPOSED MODULES (FOR 4.8°) S U N P 2h2 1' 2 3 0 cd$n4. P6 <<< <<< GEN"•.O' Digitally �� 57.8 16 76.4 100.9 �o ,=�rs�sie W. a rmocrat P5 OR10P,:2.` S E Module Size 19.5 Sq. ft. `gSONAtE?G` Castillo Date: P1 > 2022.03.0 Exposed modules Partial 215355 A� >>��j>>� P2 ' �7- 1 1' 2 3 Pressure "Op 17 l P7 0 0 19.50 0 76.40 PROJECT NAME P4 �� �� ALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS: 89 PSF P3 7� � W J 00 IJ Q P7 ���� Z IY J W ~ LEGEND LIJ - LEGEND � LLi ^ W I--- U Z-P8 WIND ZONE 1 (TYP) ® W IY - EXPOSED MODULE LLI ^^^^ _17 - WIND ZONE 1' (TYP) ® - EDGE MODULE W �7� 0 - NON- EXPOSED MODULE J MO cIf 7 - WIND ZONE 2 (TYP) Q Ln � 1-17 - MISSING MODULE � 1_1 2 ILL. �F B 0 - WIND ZONE 3 (TYP) - MIN. MODULE EDGE DISTANCE LINE LLLLLLLLLLL ,qc - MODULE EXPOSURE LINE ROOF#3 FOR METAL ROOF FOR FLAT ROOF - WIND ZONE 1 (TYP) SHEET NAME (06) LG NEON: LG380N1C-A6 - WIND ZONE 2e (TYP) PARTIAL PRESSURE AND (380W)MODULES 2h2 DISTANCE : 1'-0" 2h2 DISTANCE : 1'-0" MODULES EXPOSURE 0.5h DISTANCE : 7' -6" 0.5h DISTANCE : 7' -6" - WIND ZONE 2n (TYP) NOTE: PARTIAL PRESSURES OF THE WIND ZONES ON SHEET SIZE ALL MODULES HAVE BEEN VERIFIED AND ARE WITHIN - WIND ZONE 2r(TYP) ANSI B THE ALLOWABLE PER THE MANUFACTURER - WIND ZONE 3r(TYP) 11" X17" SPECIFICATION, INSTALLER SHOULD FOLLOW THE 1 PARTIAL PRESSURE AND MODULES EXPOSURE LAYOUT TO AVOID HIGHER ZONAL PARTIAL SHEET NUMBER PRESSURES. ANY CHANGES IN LAYOUT SHOULD BE LLLLLLLLLLL - WIND ZONE 3e (TYP) S-01.1 SCALE: 1/8"= V-0" REPORTED BACK TO THE ENGINEER OF RECORD. S-01 •1 Castillo Engineering END CLAMP MID CLAMP SOLAR DONE RIGHT® PV MODULE 3/8-24 X 0.8" ROUND POINT SETSCREW CASTILLO ENGINEERING (N)SNAPNRACK RAIL UR-60 RAIL(TYP.) h2 SERVOACES5 S-5-N CLAMP LLC 620 N.WYMORE ROAD, SUITE 250, MAITLAND,FL 32751 TEL:(407)289-2575 _ ERMOCRATES E.CASTILLO-FL PE 52590 OO OO p COPYRIGHTED BY CASTILLO ENGINEERING 7 7 3-- SERVICES,LLC — REVISIONS 16" SEAM SPACING � DESCRIPTION DATE REV (E)SNAP-LOCK SEAM 1" HIGH AND 16" O.C. 1 ATTACHMENT DETAIL (FRONT VIEW) PROJECTINSTALLER S-02 SCALE- 1 1/2" = V-0" SUNPRG ,.dE'crisri4'., Digitally Ermocrate 9 STATE �. s E Castillo �7® Date: 2022.03.0 215:35:54 °S o u O N 00 o N M O o p.83 PROJECT NAME Lq 04 W rn Z W ~ J 0 w � 3.54 � W Z � W J Mo Q� 2.00 [50.801 1 =3.14 LLo O Units are Inches with 3,26 LL mm in brackets O General Notes: SHEET NAME 1. S-5-N Clamp 2. M8-1.25 SS Hex Flange Bolt(13mm Socket) IN 3. 3/8-24 SS Round Point Setscrew(3/16 Hex Drive) Y„ ATTACHMENT DETAIL 4. Example Roof � �\ SHEET SIZE ANSI B 2 ATTACHMENT DETAIL (FRONT VIEW) 1111 X 17" SHEET NUMBER S-02 SCALE: NTS S-02 Castillo Engineering SOLAR DONE RIGHT® SEE (2/S-02.1) FOR SOLAR MODULE CASTILLO ENGINEERING ENLARGED VIEW h2 SERVICES,LLC COA#28345 620 N.WYMORE ROAD, SUITE 250, MAITLAND,FL 32751 FLAT ROOF TEL:(407)289-2575 ERMOCRATES E.CASTILLO-FL PE 52590 COPYRIGHTED BY Q CASTILLO ENGINEERING SERVICES,LLC REVISIONS DESCRIPTION DATE REV 2"X4" TRUSSES @ 24" O.C. PROJECT INSTALLER 1 ATTACHMENT DETAIL S U N P RG 7-02.1 SCALE: 1" = V-0" "`E'crisri4'., Digitally Ermocrate GROUNDING & END/MID CLAMP STATE OF :W S E O•. Castillo Date: 2022.03.0 2 15:35:55 UNIRAC LIGHT RAIL PROJECT NAME L-FOOT N E0 w —.1 00 QMLSH: ABASE LOW 0 U Q 0-) SLOPE MOUNT z � c� w � J 0 W Lu FLAT ROOF Cn F U W ZIlf E CURB PITCH PANS 0� — W_ ATTACHMENT ALIGN W � 0- TWO FASTENERS WITH J o � TRUSS UNDERNEATH Q (D O 1711 _ Ln LL SHEET NAME ATTACHMENT DETAIL 4"X4"TRUSS SPANNER FOR 2"X4"TRUSSES @ 24" O.C. MISSED TRUSS SPANNER (IF REQUIRED) 5/16"DIA. X 3"MIN. EMBEDMENT LAG SCREW AT SHEET SIZE EACH ATTACHMENT POINT INTO EXISTING FRAMING ANSI B 11" X 17" MAINTAIN 3/4" DISTANCE 2 ATTACHMENT DETAIL (ENLARGED VIEW) FROM THE EDGE PER SHEET NUMBER S-02.1 SCALE: 1"=4" NDS 2015 S-02.1 130 126 115 Castillo 140 115 in Engineering 150 120 SOLAR DONE RIGHT® x CASTILLO ENGINEERING ISS .r { w SERVICES, LLC LOSS n. d r COA#28345 V_ 140 620 N.WYMORE ROAD, 14A • SUITE 250, 150 Emgm sa.a MAITLAND,FL 32751 ba TEL:(407)289-2575 150 ERMOCRATES E.CASTILLO-FL PE 52590 a asr 140 om COPYRIGHTED BY am+ CASTILLO ENGINEERING Y° a.P SERVICES,LLC ti 160 Mo- ISO REVISIONS 1. values• ulllmulu desle.3-setond gust r wine speeds io miles per hwr (.7s)at 33 - 1 170 DESCRIPTION DATE REV tt (li).have ground iw Fsposure C tat- d a.r °gory. ryiaa 2. Lima-interpolation wt-..contours 160 Yon s permitted. -i oa1M 3. ]slams and cwstal areas ontside the lest contour shall use the last Wind speed 179 Ont.-.1 the Cwat.1 area. 4. .main.terrain, gorges, « n prmnt°r be ees:and special�ina regions snau a,Inca Ear w°: 1 Wind court- 180 PROJECT INSTALLER tions. S. xi,d speeds c respond to appr°xtmat Sly 180 a 7%probability of exteedance in Se years rs (A-1 Exceedance Probability=e.ea143, Mal-7"years). SUNPR . : . FOR TILT 18.40 FIGURE 1609.3(1) ULTIMATE DESIGN WIND SPEEDS.VOLT.FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES ,o``E'crisri4�..,,, Digitally DESIGN PRESSURES �. .h°.523 igne1pre WIND LOAD CALCULATIONS FOR MODULES INSTALLED ON ROOFS WITH A HEIGHT LESS THAN 60' : = Ermocrate ROOF ZONE DOWN UP O'•.STATE OF 4: s E SITE INFORMATION 1 20.7 -70.5 psf °gSONAtEpp Castillo FBC VERSION 2020 RISK CATEGORY II r X X psi Date: MEAN ROOF HEIGHT(1) 15.0 EXPOSURE CATEGORY C 2e 20.7 -70.5 psi Module allowable uplift pressure 126 psf : 2022.03.0 ROOF LENGTH (ft) 47.6 ROOF SLOPE 4 /12 2n 20.7 -88.5 psf Module allowable down pressure 126 psf 2 15:35:55 ROOF WIDTH (ft) 44.5 ROOF SLOPE(°) 18.4 2r 20.7 -88.5 psf PARAPET HEIGHT(ft) 0.0 ROOF TYPE GABLE 3e 20.7 -88.5 psf PROJECT NAME MODULE LENGTH(in) 68.5 ULTIMATE WIND SPEED 170 mph 3r 20.7 -104.3 psi MODULE WIDTH(in) 41.00 NOMINAL WIND SPEED 132 mph ARRAY FACTORS MODULE ORIENTATION PORTRAIT EXPOSURE FACTOR(Ce) 1.000 W J 04 00 MODULE AREA(sq.ft) 19.50 TEMPERATURE FACTOR(Ct) 1.000 ARRAY EDGE FACTOR(EXPOSED) 1.5 SOLAR PANEL PRESSURE M GROUND SNOW LOAD(psf) 0.0 IMPORTANCE FACTOR(IS) 1.000 ARRAY EDGE FACTOR(NON-EXPOSED) 1 EQUALIZATION FACTOR 0.68396 z cM DEAD LOAD(psf) 3.0 SLOPE FACTOR(Cs) 0.793 w LLI LL SLOPED ROOF SNOW LOAD(psf) 0.0 KD 0.850 ADJUSTED DESIGN PRESSURES 0 LU LLI EFFECTIVE WIND AREA(ft) 19.5 KZT 1.000 ROOF ZONE DOWN UP(Exposed) UP(N.Exposed) (n U GROUND ELEVATION(ft) 13.0 Ke 1.000 1 16.0 -72.4 -48.2 psf w z 0� HVHZ NO KZ 0.849 1' X X X psf Q W 2e 16.0 -72.4 -48.2 psf w [' 0- 2n 16.0 -90.8 -60.5 psf J cM H DESIGN CALCULATIONS 2r 16.0 -90.8 -60.5 psf Q � Of VELOCITY PRESSURE(q)= .00256*KEKzKzrKDV 3e 16.0 -90.8 -60.5 psf = Lo � VELOCIfYPRESSURE(ASD) 32.0 psf 3r 16.0 -107.0 -71.3 psf WIDTH OF PRESSURE COEFFICIENT 44.5'*10% = 4.45' ZONE WIDTH A 4 FT ATTACHMENTS USED 15'*40% = 6' ZONE 2 WIDTH NIA (FOR{°)<7°) ATTACHMENT MODEL S-5-N ATTACHMENT STRENGTH 369 Ibs SHEET NAME ZONE 3 WIDTH N/A (FOR{°)<7°) STRUCTURE MAX DESIGN LOADS ALLOWABLE CALCULATION EXTERNAL PRESSURE COEFFICIENT ZONE 1 0.467 -2.023 LIMIT MAX SPAN TO 36 in ZONE T X X RAFTERISEAM SPACING 16 in NO.OF RAILS Exposed: 2 Non.Exp: 2 ZONE 2e 0.467 -2.023 ROOF ZONE DOWN UP(Exposed) UP(N.Exposed) SPANS(E) SPANS(N.E) SHEET SIZE ZONE 2n 0.467 -2.585 1 121.8 275.4 367.2 Ibs 16 in 32 in ANSI B ZONE 2r 0.467 -2.585 1' X X X Ibs X in X in 11 II X 1711 ZONE 3e 0.467 -2.585 2e 121.8 275.4 367.2 Ibs 16 in 32 in 2n 60.9 345.6 230.4 Ibs 16 in 16 in ZONE 3r 0.467 3.078 2r 60.9 345.6 230.4 Ibs 16 in 16 in SHEET NUMBER 3e 60.9 345.6 230.4 Ibs 16 in 16 in S_O 2 a 2 INTERNAL PRESSURE COEFFICIENT{+/) 0.18 3r 60.9 271.5 Ibs 16 in 16 in 130 126 115 Castillo 140 115 in Engineering 150 120 SOLAR DONE RIGHT® x CASTILLO ENGINEERING SERVICES, LLC LOSS n. d r COA#28345 V_ 140 620 N.WYMORE ROAD, 14A • SUITE 250, 150 Emgm sa.a MAITLAND,FL 32751 ba TEL:(407)289-2575 150 ERMOCRATES E.CASTILLO-FL PE 52590 a asr 140 om COPYRIGHTED BY am+ CASTILLO ENGINEERING Ir. a.. SERVICES,LLC ti 160 Mo- ISO REVISIONS 1. values• ulllmulu deslgn 3-setond gust r wine speeds io miles per hwr (.7s)at 33 - 1 170 DESCRIPTION DATE REV Et (li).have ground iw Fsposure C tat- d a.r e gory. ryiaa 2. Lima-interpolation wtsreen contours 160 Yon s permitted. -i oa1M 3. ]slams and cwstal areas ontside the lest contour shall use the last Wind speed 179 Ont.-°E the Cwatil area. 4. .main.terrain, gorges, « n prmntor be ees:and special�ina regions snau a,Inca Ear was 1 Wind court- - 180 PROJECT INSTALLER tions. S. xi,d speeds c respond to appr° -ly 180 a 7%probability of exteedance in SO years (A-al Exceedance Probability=e.00143, Mal-7"years). pia SUNPR FOR TILT 39.80 FIGURE 1609.3(1) ULTIMATE DESIGN WIND SPEEDS.VOLT.FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES ,o``E'crisri4�..,,, Digitally DESIGN PRESSURES :` ho.523 igna§re WIND LOAD CALCULATIONS FOR MODULES INSTALLED ON ROOFS WITH A HEIGHT LESS THAN 60' : = Ermocrate ROOF ZONE DOWN UP s E R 1 30.9 541 sr ss> -E�� Castillo SITE INFORMATION P ONAt FBC VERSION 2020 RISK CATEGORY II 1' X X psf Date: MEAN ROOF HEIGHT(ft) 15.0 EXPOSURE CATEGORY C 2e 30.9 -54.1 psf Module allowable uplift pressure 89 psf ': 2022.03.0 ROOF LENGTH (ft) 47.6 ROOF SLOPE 10 /12 2n 30.9 -62.7 psf Module allowable down pressure 126 psf "" 2 15:35:56 ROOF WIDTH (ft) 44.5 ROOF SLOPE(°) 39.8 2r 30.9 -64.1 psf PARAPET HEIGHT(ft) 0.0 ROOF TYPE GABLE 3e 30.9 -76.2 psf PROJECT NAME MODULE LENGTH(in) 68.5 ULTIMATE WIND SPEED 170 mph 3r 30.9 43.4 psf MODULE WIDTH(in) 41.00 NOMINAL WIND SPEED 132 mph ARRAY FACTORS MODULE ORIENTATION PORTRAIT EXPOSURE FACTOR(Cc) 1.000 w J 04 00 MODULE AREA(sq.ft) 19.50 TEMPERATURE FACTOR(Ct) 1.000 ARRAY EDGE FACTOR(EXPOSED) 1.5 SOLAR PANEL PRESSURE 0.68396 Q GROUND SNOW LOAD(psf) 0.0 IMPORTANCE FACTOR(Is) 1.000 ARRAY EDGE FACTOR(NON-EXPOSED) 1 EQUALIZATION FACTOR z CM DEAD LOAD(psf) 3.0 SLOPE FACTOR(Cs) 0.465 w J LL SLOPED ROOF SNOW LOAD(psf) 0.0 KID0.850 0 LU ADJUSTED DESIGN PRESSURES _ � EFFECTIVE WIND AREA(ft 2) 19.5 Kzr 1.000 ROOF ZONE DOWN UP(E)posed) UP(N.Exposed) (n U GROUND ELEVATION(ft) 13.0 Ke 1.000 1 16.0 55.5 -37.0 psf uJ Z Of HVHZ NO K7 0.849 1' X X X psf 0� Q LU 2e 16.0 55.5 -37.0 psf LU [' 0- 2n 16.0 -64.3 -42.9 psf cM H DESIGN CALCULATIONS 2r 16.0 55.5 -37.0 psf Q c) of VELOCITY PRESSURE(q)= .00256"KEKzKz(KDV2 3e 16.0 -78.2 -52.1 psf = Lo � VELOCITY PRESSURE(ASD) 32.0 psf 3r 16.0 44.5 -29.7 psf WIDTH OF PRESSURE COEFFICIENT 44.5'"10% = 4.45' ZONE WIDTH A 4 FT ATTACHMENTS USED 15'*40% = 6' ZONE 2 WIDTH NIA (FOR{°)<7°) ATTACHMENT MODEL S-5-N ATTACHMENT STRENGTH 369 bs SHEET NAME ZONE 3 WIDTH NIA (FOR{°)<7) STRUCTURE MAX DESIGN LOADS ALLOWABLE CALCULATION EXTERNAL PRESSURE COEFFICIENT ZONE 1 0.784 -1.510 LIMIT MAX SPAN TO 36 in ZONE 1' X X RAFTERISEAM SPACING 16 in NO.OF RAILS Exposed: 2 Non.Exp: 2 ZONE 2e 0.784 -1.510 ROOF ZONE DOWN UP(Exposed) UP(N.Exposed) SPANS(E) SPANS(N.E) SHEET SIZE ZONE 2n 0.784 -1.777 1 121.8 211.2 281.6 Ibs 16 in 32 in ANSI B ZONE 2r 0.784 -1.510 1' X X X Ibs X in X in 11 II X 1711 ZONE 3e 0.784 -2.200 2e 121.8 211.2 281.6 Ibs 16 in 32 in 2n 121.8 244.6 326.2 Ibs 16 in 32 in ZONE 3r 0.784 1.176 2r 121.8 211.2 281.6 Ibs 16 in 32 in SHEET NUMBER 3e 60.9 297.5 198.3 Ibs 16 in 16 in S-02 a 3 INTERNAL PRESSURE COEFFICIENT(+/) 0.18 3r 121.8 338.9 225.9 Ibs 32 in 32 in Castillo (( neeri 130 Enging\.n 120 115 SOLAR DONE RIGHTO 140 115 13e CASTILLO ENGINEERING Ise 120 SERVICES, LLC a COA#28345 ada 620 N.WYMORE ROAD, SUITE 250, � MAITLAND,FL 32751 140 -,� • 14e TEE.CA CASTILLO 75 1 ERMOCRATES E CASTILLO-FL PE 52590 h lye f r••• Anan i COPYRIGHTED BY 150 CASTILLO ENGINEERING .` ,`... SERVICES,LLC 140 oa. REVISIONS Man oao ? 160 DESCRIPTION DATE REV MoLas` ISO 1. Values are UIUaare design 3-3,econd gust an wiM speeds in silos Per hear(a/s)at 33 170 ft(Ida)abode pound for Esposure c cat- egorY. nnM+ 2. Linear interpolation botwann suntans 160 s permi d tte . - i aea - 3. Islands and coastal areas outside the last contour shall use the last wind speed 170 .+n PROJECT INSTALLER contour of the coastal was. 4. Mountainous terrain,gorges, ae prmnt-i.., and special.1nd rcgi os a M 1 shall aain far unusual wind ndi- ISO tuns. no ids. Mind spee corspond to approsisately ISO 71:prab.eility of e.t dante - so y S U N P R .. (aual Ezceedaa►rabtlilitY=d.eai43e3, m ns MMI.700 years). r„BAST;'. Digitally FIGURE1609.30) n, vn ignalare FOR TILT 4.80 ULTIMATE DESIGN WIND SPEEDS,V ur r,FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES Ermocrate o,.FTATE pF s E FS(pR Castillo p•.S/ONA�Ec\•• WIND LOAD CALCULATIONS FOR MODULES INSTALLED ON ROOFS WITH A HEIGHT LESS THAN 60' DESIGN PRESSURES a°PE Date: ROOF ZONE DOWN UP 2022.03.0 SITE INFORMATION 1 16.0 56.4 psf : , m.,,�.,.,oao 2 15:35:56 FBC VERSION 2020 RISK CATEGORY II 1' 16.0 23.1 psf MEAN ROOF HEIGHT(ft) 15.0 EXPOSURE CATEGORY C ROOF LENGTH (ft) 47.0 ROOF SLOPE 1 /12 2 16.0 74.5 psf Module allowable uplift pressure 89 psf PROJECT NAME ROOF WIDTH (ft) 43.1 ROOF SLOPE(°) 4.8 3 16.0 -98.4 psf Module allowable down pressure 126 psf PARAPET HEIGHT(ft) 0.0 ROOF TYPE FLAT MODULE LENGTH(in) 68.5 ULTIMATE WIND SPEED 170 mph ARRAY FACTORS _ N MODULE WIDTH(in) 41.0 NOMINAL WIND SPEED 132 mph W J 00 MODULE ORIENTATION PORTRAIT EXPOSURE FACTOR(Ce) 1,000 ARRAY EDGE FACTOR(EXPOSED) 1.5 SOLAR PANEL PRESSURE U 0.68396 M MODULE AREA(sq.fL) 19.50 TEMPERATURE FACTOR(G) 1.000 ARRAY EDGE FACTOR(NON-EXPOSED) 1 EQUALIZATION FACTOR z l- J GROUND SNOWLOAD(psf) 0.0 IMPORTANCE FACTOR(Is) 1,000 Q Lw LL. DEAD LOAD(psf) 3.0 SLOPE FACTOR(Cs) 1.004 - LU SLOPED ROOF SNOW LOAD(psf) 0.0 KID0,850 ADJUSTED DESIGN PRESSURES U) � Q EFFECTIVE WIND AREA(its) 19.5 Kn 1.000 ROOF ZONE DOWN UP(Exposed) UP(N.Exposed) W z Of W 1' 16.0 -116.0 GROUND ELEVATION(ft) 13.0 Ke 1.000 1 16.0 - 6.0 -116.0- 6.0 psf psf Q_ W HVHZ NO KZ 0.849 J M 2 16.0 76.4 50.9 psf O DESIGN CALCULATIONS 3 16.0 67.3 psf = LO LL VELOCITY PRESSURE(q)_ .00256*KEK2KzTKDV2 ATTACHMENTS USED VELOCITY PRESSURE(ASD) 32.0 psf ATTACHMENT MODEL Simplified Qbase WIDTH OF PRESSURE COEFFICIENT 43.11'*10% = 4.311' ZONE WIDTH A 9 FT ATTACHMENT STRENGTH 625 Ibs 15'*40% = 6' ZONE 2 WIDTH 9 FT (FOR(°)<7°) SHEET NAME ZONE 3 WIDTH 3 FT (FOR(°)<7) MAX DESIGN LOADS ALLOWABLE STRUCTURE LIMIT MAX SPAN TO N/A in CALCULATION EXTERNAL PRESSURE COEFFICIENT ZONE 1 0.271 -1.580 RAFTERISEAM SPACING 24 in NO.OF RAILS Exposed: 2 Non.Exp: 2 ZONE V 0.271 0.900 ROOF ZONE DOWN UP(Exposed) UP(N.Exposed) SPANS(E) SPANS(N.E) SHEET SIZE ZONE 2 0.271 -2.146 1 182.7 330.1 440.1 Ibs 24 in 48 in ANSI B ZONE 3 0.271 -2.893 1' 182.7 182.7 182.7 Ibs 48 in 48 in 1111 X 17" 2 182.7 436.2 581.6 Ibs 24 in 48 in INTERNAL PRESSURE COEFFICIENT(+/-) 0.18 3 91.3 576.1 384.1 Ibs 24 in 24 in SHEET NUMBER S-02.4 Castillo p gi Enneering SOLAR ARRAY(10.260 kW-DC STC) SOLAR DONE RIGHT® (27)LG NEON:LG380N1C-A6(380W)MODULES (03)BRANCHES OF 09 MODULES CAS TILL ER ENGINEERING c c c c G G G G c SERVICES,LLC NOTE: COA#28345 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO 620 N.WYMORE ROAD, SUITE 250, MEET THE REQUIREMENTS OF THE NEC 2017, AND MAITLAND,FL32751 OCABLES THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY ERMOCRATTEL ESE(CAST$L-2575 PE52590 CENTER CERTIFICATION, INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF 7CASTILLO PYRIGHTED BY MODULES PER STRING, MAXIMUM OUTPUT, MODULE ENGINEERING MANUFACTURER AND MODEL NUMBER, INVERTER ERVICES,LLC MANUFACTURER AND MODEL NUMBER,AS APPLICABLE. REVISIONS 2.PROVIDE TAP BOX IN COMPLIANCE WITH NEC 312.8 IF PANEL GUTTER SPACE IS INADEQUATE. DESCRIPTION DATE REV ti ti 3. IF THE FUSED AC DISCONNECT WIRE RUN EXCEEDS — — — — — c 10 FT FROM THE POINT OF INTERCONNECTION, CABLE LIMITERS OR CURRENT-LIMITED CIRCUIT BREAKERS ENPHASE:IQ7PLUS-72-2-US MUST BE INSTALLED FOR EACH UNGROUNDED MICROINVERTERS CONDUCTOR PER NEC 705.31. 4.REFER SHEET DS-12 FOR LOAD CALCULATIONS. PV MODULES PROJECT INSTALLER #6 BARE CU WIRE PROTECTED PER NEC 250.64(B) S U N P R TO UTILITY GRID SUPPLY SIDE CONNECTION Digitally USING INSULATION PIERCING OR 9 y (N)SOLADECK POLARIS TAPS PER NEC 705.12(A) L1 L2 N ,% M1".ers igna$re • Ermocrate 600V,NEMA 3R (E)BI-DIRECTIONAL STATE OF '�� S E P 2. UL LISTED (N)ALTERNATIVE POWER o SERVICE POINT AND CBStIIIO SOURCE AC DISCONNECT/ UTILITY METERING G L2 -1 L2 L1 L2 -1 RAPID SHUTDOWN: 1-PHASE,240V Date: (N)125A ENPHASE IQ COMBINER 3 240V,60AMP RATED, s "�� '" 2022•03•0 G L2 L1 L2 a L2 L1 (X-IQ-AM1-240-3 [WITH UPTO 4 L1 L2 N -m FACTORY INSTALLED ) ( ) NEMA 3R,UL LISTED 2 15:35:57 10A OR 15A BREAKER 2-POLE BREAKERS AND ENVOY LOCKABLE&FUSIBLE FOR ENVOY COMMUNICATION GATEWAY] WITH 60A FUSES L1 L2 N PROJECT NAME (3)10/22 ROMEX RUN IN ATTIC L1 R L1 L1 (3)#10 AWG THWN-2-RED L2 2 L2 (3)#10 AWG THWN-2-BLACK N N N J EGC#6 AWG THWN-2 GND W 00 IN V IMC,RMC,FMC,LFMC, — — G G G (E)MAIN BREAKER U Q 0-) EMT OR EQUIVALENT 200A/2P,240V z Of CONDUIT RUN w __J — `u1 LL Q (3)#6 AWG THWN-2 (3)#6 AWG THWN-2 L1 — � LLI (1)#6 AWG THWN-2 GND IN 1"PVC,IMC,RMC,LFMC, L1 U) � (� (3)#10 AWG THWN-2-RED IN 1"PVC,IMC,RMC,LFMC, RTRC,LFNC,EMT OR FMT L2 L2 W Z 11� (3)#10 AWG THWN-2-BLACK RTRC,LFNC,EMT OR FMT CONDUIT RUN LLI EGC#6 AWG THWN-2 GND L1 L1 Q — IN 1"IMC,RMC,LFMC,PVC, CONDUIT RUN w RTRC,LFNC,FMT OR EMT L2 L2 M 1-- CONDUIT RUN c � L1 L1 Q ) O (N)JUNCTION BOX L2 L2 = 600V,NEMA 3R UL LISTED 20A/2P L1 L1 L1 N EXISTING L2 L2 L2 20A/2P G GROUNDING SHEET NAME L1 L1 ELECTRO L1 SY SYSTEM DE ELECTRICAL (E)MAIN SERVICE — L2 L2 L2 20A/2P DISCONNECT/MAIN LINE DIAGRAM L1 L1 L1 DISTRIBUTION PANEL, L2 L2 - 200A RATED,240V SHEET SIZE - - - - - - G]-- - - G - - - - - - - - G - - ANSI B N G 1 ELECTRICAL LINE DIAGRAM 1111 X 17" E-01 SCALE: NTS SHEET NUMBER E-01 ELECTRICAL CALCULATION Castillo ELECTRICAL NOTES Engineering MODULE MANUFACTURER LG MODULE PROPERTIES SOLAR DONE RIGHT® MODULE MODEL LG3BON1 C-A6 VDc 41 .9 ISc 1 1 .39 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED CASTILLO ENGINEERING INVERTER MANUFACTURER ENPHABE VMPP 35.7 IMP 1 0.65 FOR ITS APPLICATION. SERVICES, LLC INVERTER MODEL ENPHABE IQ 7 PLUS TO VOC -0.26%/ 'C TC VMP -C.34%/�C COA#28345 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 620 N.WYMORE ROAD, MODULES/BRANCH CIRCUIT 1 9 PMP 3BO.❑ NOCT 45 'C SUITE250, DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75 MAITLAND,FL32751 MODULES/BRANCHDEGREE C. TEL:('°7)289-2575 CIRCUIT 2 9 M❑DULE5/BRANCH CIRCUIT 3 g 3. THE WIRES ARE SIZED ACCORDING TO NEC 110.14. TOTAL ARRAY POWER (KW) 10.26❑ ERMOCOPYRIGHTED BYL52590 SYSTEM AC VOLTAGE 240V 1-PHASE 4. WIRING, CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL CASTILLO ENGINEERING INVERTER PROPERTIES BE ROUTED DIRECTLY TO,AND LOCATED AS CLOSE AS POSSIBLE TO SERVICES,LLC DESIGN TEMPERATURE OUTPUT VOLTAGE 240 L-L 1-PH THE NEAREST RIDGE, HIP, OR VALLEY. REVISIONS MIN. AMBIENT TEMP. �F 32 MAX INPUT DC VOLTAGE 60 VDC 5. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL DESCRIPTION DATE REV MAX. AMBIENT TEMP. 'F 1 17 OPERATING RANGE 1 6 - 6❑ VDC EQUIPMENT SHALL COMPLY WITH NEC 110.26. CALCULATED MAX. VOC 45 MPPT VOLTAGE RANGE 27 - 45 VOc 6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CALCULATED MIN VMP 28 START VOLTAGE 22 VDC CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, CONDUIT FILL MAX INPUT POWER 440 WOO FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND NUMBER OF CONDUITS 1 CONTINUOUS AC POWER 290 VA STANDARDS. 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE PROJECT INSTALLER AMPACITY CALCULTIONS NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 1 .25 X 9❑ °C AMBIENTT TEMP CONDUIT FILL DERATED MAXIMUM CIRCUIT 8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND CIRCUIT MAX AMPS MAX AMPS AWG AMPACITY EMP °F DERATE FILL DEBATE AMPACITY BREAKER READILY VISIBLE. . 9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE S U N P R CIRCUIT 1 10.9 13.6 #1❑ 40 130 0.76 6 ❑.B 24.32 20 A FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Digitally CIRCUIT 2 10.9 13.6 #1❑ 40 130 0.76 6 ❑.B 24.32 20 A 10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER •,.••``°e.'casri4.,,, G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. :' No.szs igua%ge v Ermocr ate CIRCUIT 3 10.9 13.6 #1❑ 40 130 0.76 6 ❑.B 24.32 20 A 11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE gi..�rarE S E 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL ;s`°• °P�?'' AC COMBINER nS�oNAtE;.*`•� Castillo 32.67 40.B #6 75 95 0.96 3 1 72 60 A PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE Date: PANEL OUTPUT ENTRANCE. 2022.03.0 13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. - 2 15:35:57 MAXIMUM CIRCUIT VOLTAGE DROP 2% 14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT PROJECT NAME VOLTAGE DROP CALCULATIONS RESISTANT PER NEC ARTICLE 300.6 (C)(1)AND ARTICLE 310.10(D). CIRCULAR MAX 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR CIRCUIT AWE MILLS LENGTH I v USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). CIRCUIT 1 #1❑ 1 03BO 1 0.9 240 1 7B FEET 17. THIS SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN OF PV w J CONDUCTORS IN COMPLIANCE WITH NEC 690.12. 00 CIRCUIT 2 #1❑ 1 03B❑ 10.9 240 1 7B FEET Q CIRCUIT 3 #1❑ 10380 1❑.9 240 1 7B FEET 18. LABELING IN COMPLIANCE WITH NEC 690.12 AND 690.56(C) IS SHOWN M AC COMBINER PANEL OUTPUT #6 26240 1 32.7 1 240 1 49 FEET ON SHEET E-03. w H J 19. ALL CONDUITS TO BE INSTALLED A MIN OF 7/8"ABOVE THE ROOF Q IW LL SURFACE. - � W NOTES N TEMP DERATE BASED ON NEC TABLE 310.1 5(B)(2)(A) N 0L CONDUIT FILL DERATE BASED ON NEC TABLE 31 0.1 5(B)(3)(A) LL MAXIMUM VOC CALCULATED USING MODULE MANUFACTURE TEMPERATURE COEFFICIENTS PER NEC 690.7(A) W UNLESS OTHERWISE SPECIFIED, ALL WIRING MUST BE THHN OR THWN-2 COPPER C) ALL WIRE SIZES LISTED ARE THE MINIMUM ALLOWABLE Lo O IN ANY CELL INDICATES THAT THE SYSTEM IS SAFE AND COMPLIES WITH NEC REPUIREMENTS I ERMOCRATES CASTILLO PE#52590 AN ENGINEER L.L IN ANY CELL INDICATES A POTENTIALLY UNSAFE CONDITION LICENSED PURSUANT TO CHAPTER 471, CERTIFY INFORMATION INPUT BY SYSTEM DESIGNER THAT THE PV ELECTRICAL SYSTEM AND INFORMATON OBTAINED FROM MANUFACTURER DATASHEETS ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN SHEET NAME THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 107, THE NEC 2017, AND WIRING CALCULATIONS THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION. SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-02 A WARNING PHOTOVOLTAIC SYSTEM AC DISC • EnginCastillo ELECTRIC SHOCK HAZARD RATED AC OPERATING CU' ' SOLAR PV SYSTEM EQUIPPED SOLAR DONE RIGHT® TERMINALS ON BOTH LINE AND AC NOMINALOPERATING VOLTAGE • CASTILLO ENGINEERING LOAD SIDES MAY BE ENERGIZED WITH RAPID SHUTDOWN SERVICES, LLC IN THE OPEN POSITION LABEL LOCATION: WYM 28345 620 N.WYMORE ROAD, AC DISCONNECT,POINT OF INTERCONNECTION SUITE 250, LABEL LOCATION: (PER CODE:NEC 690.54) MAITLAND,FL 32751 AC DISCONNECT,POINT OF INTERCONNECTION TEL:(407)289-2575 ERMOCRATES E.CASTILLO-FL PE 52590 (PER CODE:NEC 690.13(B)) TURN RAPID SHUTDOWN COPYRIGHTED BY AWARNING DUAL POWER SOURCE POWER SWITCH TO THE CASSIERVIC LLO SINLCRING SECOND SOURCE IS PHOTOVOLTAIC SYSTEM SOURCE OUTPUT • • • „ „ soLAR ELECTRic OFF POSITION TO PVPANELS REVISIONS LABEL LOCATION: NOT RELOCATE THIS OVERCURRENT DEVICE SHUT DOWN PV SYSTEM DESCRIPTION DATE REV POINT OF INTERCONNECTION (PER CODE:NEC 705.12(B)(2)(3)(b)) LABEL LOCATION: AND REDUCE POINT OF INTERCONNECTION (PER CODE:NEC 705.12(B)(2)(3)(b)) SHOCK HAZARD PHOTOVOLTAIC SYSTEDATA PER PANEL IN THE ARRAY WITH RAPID • OPERATING AC VOLTAGE240 PROJECT INSTALLER SHUTDOWNLABEL LOCATION: NOMINALOPERATING AC FREQUENCY— AC DISCONNECT,POINT OF INTERCONNECTION LABEL LOCATION: MAXIMUM AC (PER CODE:NEC 690.56(C)(1)(a),IFC 1204.5.1 AC DISCONNECT POWER— S U N P R (PER CODE:NEC 690.56(C)(3)) MAXIMUM AC CURRENT— CAUTION !1.21 ADHESIVE FASTENED SIGNS: Digitally •THE LABEL SHALL BE VISIBLE,REFLECTIVE AND SUITABLE FOR MAXIMUM OVERCURRENT DEVICE RATING POWER TO THIS BUILDING o"E:'crisri4.,, THE ENVIRONMENT WHERE IT IS INSTALLED[NFPA 1,11.12.2.1] FOR • •ULE PROTECTION PER CIRCUIT- 20 nn.ers igna$re •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD SUPPLIED • MULTIPLE SOURCES . Ermoc rate APPLIED LABELS,WARNINGS,AND MARKINGS SHOULD 9•, STATE OF S E COMPLY WITH ANSI Z535.4[NEC 110.21(B)FIELD MARKING]. FS`SoA:oP�2o` •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF 0S�NAtEp` Castillo PROPERLY ADHERED.VINYL SIGNS SHALL BE WEATHER LABEL LOCATION: RESISTANT[IFC 605.11.1.31 COMBINER BOX EMERGENCYRESPONDER: Date: (PER CODE:NEC 690.52) " 2022.03.0 WARNING THIS SOLAR PV SYSTEM IS EQUIPPED 2 15:35:58 AC COMBINER • IN CASEOF . • RAPID: WITH SHUTDOWN. PROJECT NAME LABEL LOCATION: ■ ■ • • ■ COMBINER BOX I I (PER CODE:NEC 690.52) PH. NO. • • 450-1012 TURN RAPID SHUTDOWN SWITCH TO THE "OFF" LABEL LOCATION: POSITION TO SHUTDOWN ENTIRE 'V SYSTEM LLI J 00 DISCONNECT' MAIN DISCONNECT R Q (PER CODE:NFPA-1,11.12.2.1.5) PV SOLAR ARRAY • Z M LABEL LOCATION: ON ROOF LL.I J AC DISCONNECT,POINT OF INTERCONNECTION W LL (PER CODE:NEC 690.54) • • ■ $ ()� W DISCONNECT • LOCATED . . SERVICE POINT AND UTILITY METERING LLI z 0� PHOTOVOLTAIC MAIN SERVICE DISCONNECT/ W LABEL LOCATION. MAIN DISTRIBUTION PANEL w !Y SYSTEM AC DISCONNECT,POINT OF INTERCONNECTION ALTERNATIVE POWER SOURCE AC c) O MIC ■ • ■ TERS (PER CODE:NEC 690.54) oa 9� DISCONNECT/RAPID SHUTDOWN L ENPHASE IQ COMBINER BOX = LO LL. LOCATED PV MODULE ROOF • • TOP ■ ARRAY SHEET NAME LABEL LOCATION: SYSTEM LABELING INVERTER (PER CODE:NEC 690.52) SOLAR . SHEET SIZE 5503 RAINTREE TRAIL, FORT PIERCE, FL 34982 ANSI B LINE SIDE TAP LABEL LOCATION: MAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANEL,PV DISCONNECT 11° X 17" LABEL LOCATION: LOCATED NO MORE THAN 3FT(1 M)FROM THE SERVICE DISCONNECT POINT OF INTERCONNECTION (TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8") SHEET NUMBER (PER CODE:NEC 705.12(A)) (PER CODE:NEC 690.56(B),NEC 705.10,NFPA 1,11.12.2.1) E-03 Castillo Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES,LLC COA#28345 ^/ LG N e O N®L ® �- 620 N.WYMORE ROAD, SUITE 250, MAITLAND,FL32751 LG N TEL:(407)289-2575 ONO2 LG370N1C-A6 I LG375N1C-A6 I LG380N1C-A6 Preliminary ERMOCRATESE.CASTILLO-FL PE52590 COPYRIGHTED qP BY � General Data Electrical Properties(STC*) CASTILLO ENGINEERING Cell Properties(MateriaVType) Monocrystalline/N-type Model LG370N1C-A6 LG375N1C-A6 I LG380N1C-A6 SERVICES,LLC LG370N1C-A6 I LG375N1C-A6 I LG380N1C-A6 Preliminary Cell Maker LG Maximum Power(Pmax) [W] 370 375 380 REVISIONS Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) [VJ 34.9 35.3 35.7 Module Dimensions(L x W x H) 1,740mm x 1,042mm x 40mm MPP Current(Impp) [A] 10.61 10.63 10.65 DESCRIPTION DATE REV 3 7 0 W 13 7 5 W 13 8 0 W Weight iss, it Open Circuit Voltage(Voc,!%) [A] 1.31 41.9 Glass(Material) Tempered Glass with AR Coating Short Circuit Current(Isc,!5%) [A] 11.31 11.35 11.39 Backsheet(Color) White Module Efficiency [%] 20.4 20.7 1 21.0 ® Frame(Material) Anodized Aluminium The LG NeONO 2 is LG's best selling solar module and one of the . � BifacialityCcefficierltofPower [%] 10 Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes Power Tolerance % 0-+3 most powerful and versatile modules on the market today.The cells [ ] --:MA Cables(Length) 1,t00mm x 2EA *STC(Standard Test Condition):Irradiance 1000 W/m•,cell temperature 25°C,AM 1.5 are designed to appear all-black at a distance,and the performance connector(rype/Maker) Mca/Mc PROJECT INSTALLER warranty guarantees 90.6%of labeled power output at 25 years. ♦-♦:.••-- Operating Conditions ♦♦• ••• Certifications and Warranty MaudmOperating elnem Volt [M ao-0 ♦♦. ''• IEC 6121 S0 90-1,IS0146,IEC 61730-1/2.2016, Maximum System Voltage N] 1,200 4, UI us UL 61730-1:2017,UL 61730-2:2017 ®, ' Certifications" Maximum Series Fuse Raring [tp 20 U N P R I50 9001,15014001,I50 50001 25' OHSA518001 Mechanical Tes[Load'(Front) [Pa/Psf] 5,400 MaAe in a� � Salt Mist Corrosion Test IEC 61701:2012 Severity 6 Mechanical Test Load'(Rear) [Pa/PSq 4,000 YEAR /t •. ® ® Mechanical is lTCtLoads2:2016(TestLoad based n IEC6115:20ctor(1.5)) Digitally USAF Ammonia Corrosion Test IEC 62716:2013 'Based on IEC6Loads6,0016(Test Load-Dsign oadx Safety15:Fact CAST r, ,, ;I, ♦ ®® Module:Fire Performance Type 1 L 61730) •.. - Fire Rating CWssC(UL790,ULC/ORDC1703) #': no.ers igna$,re ® ® Packaging Configuration Ermocrate Solar Module Product Warranty 25 Year Limited 9'•, STATE OF ��/. ® Number of Modules per Pallet [EA] 25 O ,..o�,ag. 1�� S E Solar Module Output Warranty Linear Warranty* '�. ton 10,.'� /'� ' Number of Modules per 40'Container [EA] 650 F•��'!ys/ONAtEOa��,, Castillo :Improved:1"year 98.5%,from 2-24th year.0.33%/yeariown,90.6%at year 25 •*In Progress Number of Modules per 53'Container [EA] 850 Date: >r Packaging Box Dimensions(L x W x H) [mm] 1,790 x 1,120 x 1,213 2p22.03.0 Temperature Characteristics Packaging Box Dimensions(Lx W x H) [in] 70.5 x 44.1 x 47.8 NMOT* rcl 42 t 3 Packaging Box Gross Weight [kg] 500 � 2 15:35:58 Pmax [%/'c] -0.34 Packaging Box Gross Weight [Ib] 1,102 voc [%/°c] -0.26 PROJECT NAME Inc [%rc] 0.03 Dimensions(mm/inch) *NMCT(Nominal Module Operating Temperature):Irradiance 800 W/m',Ambiemtempeature 20-C, Wind speed 1 m/s,Spectrum AM 1.5 Features 1042.0/41.0(Size of Shun Side) Electrical Properties(NMOT) 1002.0/39.4(D,m,-beureen GmuMing B Mounting Holes) N Model LG370N1C-A6 LG375N1C-A6 LG380N1C-A6 4o0/1.n w J 00 Enhanced Performance Warrant 25-Year Limited Product Warrant 5.0/G9 Y Y Max mum Power(Prom) [WJ 277 281 285 ' \ < Lk 16-B.Ox3.0/03x01 v �l O O MPP voltage(Vmpp) [v] 322 33.2 33.5 ownHoles LG NeONO 2 has an enhanced The NeONO 2 is covered by a 25-year limited (_) (.) z L� M MPP Current Qmpp) [A] 8A6 BAB 8.49 s-e4.3/o.z /unction sox r performance warranty.After 25 product warranty.In addition,up to$450 of G-ndiigHok W J Open Circuit Voltage(Voc) [v] 39.3 39.4 39A LLI LL. years,LG NeON®2 is guaranteed at labor costs will be covered in the rare case that P 9 e-e.6x,2.o/o.3xo.s Q least 90.6%of initial performance. a module needs to be repaired or replaced. Short Circuit Current(Ist) [A] 9.09 9.13 9.16 Mwnrig Hie LLl LIj I-V Curves w z 1100/43.3 Cable Lengrh > > - Of 12.0 1Grow Q Solid Performance on Hot Days + Roof Aesthetics w , � 10.0 BOOW P' s LG NeONO 2 performs well on hot days LG NeONO 2 has been designed with J ~ T due to its low temperature coefficient. J aesthetics in mind using thinner wires 80 60OW s s Q LO that appear all black at a distance. 1 6.0 _ LO ILL 400W c. u 4.0 zoow 20 0.0 00 50 10.0 150 20.0 25.0 300 35.0 40.0 45.0 VoltageM SHEET NAME When you go solar, ask for the brand you can trust: LG Solar DATA SHEET About LG Electronics USA,Inc. LG Electronics USA,Inc. Product specifications are subject to change without notice. LG Electronics is a global leader in electronic products in the clean energy markets b offering solar PV panels and energy storage systems.The company first embarked on a solar Solar Business Division LG370-38ON1 C-A6 AUS.df SHEET SIZE 9 Pr 9Y ip Y 9 P 9Y 9 Y Pa^Y ® LG ® LG P 2000 Millbrook Drive arch r in 1985 su orted b LG Grou's vast ex erience in the semi-conductor LCD chemist and materials industries.In 2010 LG Solar successful) 121520 energy source rese p ogram ke y p p ry Y Lincolnshire,IL 60069 released its first MgnoX®series to the market,which is now available in 32 countries.The NeON®(previous MonoX®NeON),NeON62,NeON®2 BiFacial won the"IntersoWr ANSI B AWARD"in 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. Llfe's Good Lifes Good www.lg-solarcom ©2020 LG Electronics USA,Inc.All rights reserved. 1111 X 17" SHEET NUMBER DS-01 Castillo p gi Enneering SOLAR DONE RIGHT® L LG Electronics U.S.A., Inc. CASTILLO ENGINEERING SERVICES, LLC 111 Sylvan Avenue COA#28345 Englewood Cliffs, NJ 07632 620 N.URE I EO 50 ROAD, 201.816.2000 MAITLAND,FL 32751 TEL:(407)289-2575 Friday, February 5, 2021 ERMOCRATES E.CASTILLO-FL PE 52590 COPYRIGHTED BY CASTILLO ENGINEERING RE: Mechanical Load Testing to Determine Structural Performance under Uniform Static Pressure SERVICES,LLC REVISIONS To: Castillo Engineering, DESCRIPTION DATE REV Upon your request we have conducted in house tests to determine the structural performance of the LG Module frames listed below. Our test results meet the requirements you presented in our conference call on January 29th. We will present the test criteria, results, and product limitations that may result from PROJECTINSTALLER these test conditions in this letter. The specifications and conditions presented in this letterapply retroactivelyto the following LG module(s); , .. SUNPR :. 2 Rails 3 Rails Front 9,000Pa 9,000Pa Digitally Rear 6,35013a 9,000Pa n.*zs igna$re Ermocrate Model LGxxxN1C(K)-N5(L5), LGxxxN1C(K)-A6(B6) s E ,, SS7�NAtE?. LGxxxQ1C(K)-V5, LGxxxQ1C(K)-A6 Castillo Date: *The result is based on test load. 2022.03.0 2 15:35:59 Our R&D department has tested these modules to determine the structural performance of under uniform static loading to represent the effects of a wind load on the module. This test was designed only to PROJECT NAME determine structural performance; the revised specifications apply only to the mechanical performance of the module. A safety factor of 1.5 should be applied to these test loads for obtaining design loads. It is not recommend designing anysystem to the full test load. W J 00 Q M - z M UJ J 0 WLL _- -=} W z w PmRpn load PI L daro W1 (mm) fianYRear(Pa) (mrr) Eiw..(Pa) _ - J A 13•306 2AOM165 — � urn 0 231 310 59U]lD60 �-.-. O B sz-ox, 6gmo,gwa = LO IL The scope of this test does not include electrical functionality or performance testing. Subjecting the module to these pressures may result in power degradation or total power loss. The electrical function and power generation warranties and specifications of these products are not altered by this document. SHEET NAME DATA SHEET If you have any additional questions or concerns about this letter or the test protocol, contact your LG Solar Sales Representative. SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-02 Castillo Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC Data Sheet Enphase IQ 7 and IQ 7+ Microinverters WYMO RE 345 szo N Enphase Microinverters N.SUITE 50 ROAD, Region:US MAITLAND,FL 32751 INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US TEL:(407)289-2575 Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ ERMOCRATES E.CASTILLO-FL PE 52590 Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules COPYRIGHTED BY Maximum input DC voltage 48 V 60 V CASTILLO ENGINEERING Peak power tracking voltage 27 V-37 V 27 V-45 V SERVICES,LLC Operating range 16 V-48 V 16 V-60 V REVISIONS The high-powered smart grid-ready Min/Max start voltage 22 V/48 V 22 V/60 V DESCRIPTION DATE REV Enphase Enphase IQ 7 Micro'"and Enphase IQ 7+ Micro'" Max DC short circuit current(module lsc) 15A 15A Overvoltage class DC port II II Q7 and I Q 7+ dramatically simplify the installation process while DC port backfeed current D A 0 A achieving the highest system efficiency. PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; Microinverters AC side protection requires max 20A per branch circuit Part of the Enphase IQ System,the IQ 7 and OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter PROJECT INSTALLER IQ 7+Microinverters integrate seamlessly with Peak output power 250 VA 295 VA the Enphase IQ Envoy'",Enphase Q Aggregator'" Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V/ Enphase IQ Battery',and the Enphase Enlighten'" 211-264V 183-229V 211-264V 183-229V � monitoring and analysis software. Maximum continuous output current 1.0 A 1.15 A 1.21 A 1.39 A J UN P R Nominal frequency 60 Hz 60 Hz IQ Series Microinverters extend the reliability Extended frequency range 47-68 Hz 47-68Hz AC short circuit fault current over 3 c ,.•``E,casri4•., Digitally cycles 5.8 Arms 5.8 Arms standards set forth by previous generations and y Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(240 VAC) :` No.szs ignatyre undergo over a million hours of power-on testing, 13(208 VAC) 11(208 VAC) * * Ermocrate -leading III s Eenablin Enphase to provideanindustry OvervoltageclassACport III �SS7�NAtE?G` Castillo warranty of up to 25 years. AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Date: Power factor(adjustable) 0.7 leading..0.7 lagging 0.7 leading..0.7 lagging �,° m„� „oao 2022.03.0 EFFICIENCY @240 V @208 V @240 V @208 V 2 15:35:59 Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% Easy to Install CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% PROJECT NAME MECHANICAL DATA IQ 7 Microinverter Lightweight and simple Ambient temperature range -400C to+65°C Faster installation with improved,lighter two-wire cabling Relative humidity range 4%to 100%(condensing) Built-in rapid shutdown compliant(NEC 2014&2017) Connectortype MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) J Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) w Q 00 Productive and Reliable 00 lie Weight 1.08 kg(2.38 Ibs) z M Cooling Natural convection-No fans J Optimized for high powered 60-cell and 72-cell*modules Approved for wet locations Yes w W LL More than a million hours of testing Pollution degree PD3 0 W LLI j Class II double-insulated enclosure Enclosure Class II double-insulated,corrosion resistant polymeric enclosure (LJ UL listed Environmental category/UV exposure rating NEMA Type 6/outdoor w z FEATURES LLl Smart Grid Ready Communication Power Line Communication(PLC) w Monitoring Enlighten Manager and MyEnlighten monitoring options. M � a Complies with advanced grid support,voltage and Both options require installation of an Enphase IQ Envoy. LLf � oil frequency ride-through requirements Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break LID Remotely updates to respond to changing disconnect required by NEC 690. = LL grid requirements Compliance CA Rule 21(UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, Configurable for varying grid profiles CAN/CSA-C22.2 NO.107.1-01 Meets CA Rule 21 (UL 1741-SA) This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. SHEET NAME U *The IQ 7+Micro is required to support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at https://ennhase.com/en-us/srlpyort/module-com atp ibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. DATA SHEET 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. ® E N P H A S E. To learn more about Enphase offerings,visit enphase.com E N P H A S E To learn more about Enphase offerings,visit enphase.com `� ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. SHEET SIZE P 9Y 9 P P Y P 9Y• 2018-02-08 ANSI B 11" X 17" SHEET NUMBER DS-03 Castillo Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES,LLC Data Sheet Enphase IQ Combiner 3 WYMO 620 N.WYME 50 E ROAD, Enphase Networking MODEL NUMBER MAITLAND,FL 32751 IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy'printed circuit board for integrated revenue grade PV TEL:(407)289-2575 X-IQ-AM1-240-3 production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). ERMOCRATES E.CASTILLO-FL PE 52590 ACCESSORIES and REPLACEMENT PARTS(not included,order separately) COPYRIGHTED BY Enphase Mobile Connect' CASTILLO ENGINEERING CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 SERVICES,LLC CELLMODEM-01(313/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, REVISIONS CELLMODEM-M1(413 based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5%). DESCRIPTION DATE REV Enphase The Enphase IQ Combiner 3'" with Enphase CT-200-SPLIT *Consumption monitoring is required for Enphase Storage Systems IQ EnvoyT" consolidates interconnection Ensemble Communications Kit Installed at the IQ Envoy.For communications with Enphase Encharge'"'storage and Enphase Q Combiner 3 COMMS-KIT-01 EnpowerTM smart switch.Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner' equipment into a single enclosure and and allows wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. (X-IQ-AM1-240-3) streamlines PV and storage installations by BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 PROJECT INSTALLER providing a consistent, pre-wired solution for BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity-one pair residential applications. It offers up to four XA-SOLARSHIELD-ES Replace the default solar shield with this Ensemble Combiner Solar Shield to match the look and feel of the Enphase Enpower'smart switch and the Enphase Encharge"storage system U N P R 2-pole input circuits and Eaton BR series XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) busbar assembly. XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS Digitally ,o•E,casii4•.,, Rating Continuous duty ' " e ignatlre System voltage 120/240 VAC,60 Hz * * Ermocrate 9 STATE of J C E Eaton BR series busbar rating125 A O,��NAtEp Max.continuous current rating(output to grid) 65 A Castillo Date: Max.fuse/circuit rating(output) 90 A 2022.03.0 Smart Branch circuits solar and/or storage) U to four 2-pole Eaton BR series Distributed Generation DG breakers only not included) ( g ) P P ( ) Y( ) 2 15:36:00 „ Includes IQ Envoy for communication Max.continuous current rating(input from PV) 64 A and control Max.total branch circuit breaker ratio (input) 80 A of distributed generation/95 A with IQ Envoy breaker included 9(� P ) 9 Y PROJECT NAME Flexible networking supports Wi-Fi, Ethernet,or cellular Envoy breaker 10A or 15A rating GE Q-line/Siemens Type QP/Eaton BR series included I Optional AC receptacle available for PLC bridge Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy L Provides production metering and optional consumption MECHANICAL DATA L I I monitoring Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). w J 0000 Supports Ensemble Communications Kit for Weight 7.5 kg(16.5 Ibs) U Q 0 communication with Enphase Encharge'"storage and I Enphase Enpower smart switch Ambient temperature range -400 C to+460 C(-400 to 1150 F) z _J '" J Cooling Natural convection,plus heat shield L1J LU ILL. Sim le Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction 0 LLI - p Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors [)f U • Reduced size from previous combiner 60 A breaker branch input: 4 to 1/0 AWG copper conductors LJ Z Of Centered mounting brackets support single stud Main lug combined output: 10 to 2/0 AWG copper conductors W Q mounting Neutral and ground: 14 to 1/0 copper conductors a- Always follow local code requirements for conductor sizing. w lcl� Supports back and side conduit entry Altitude To 2000 meters(6,560 feet) J co I— Up to four 2-pole branch circuits for 240 VAC plug-in INTERNET CONNECTION OPTIONS Q L breakers(not included) _ Ln O • 80 A total PV or storage branch circuits Integrated Wi-Fi 802.11b/g/n IL Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) Cellular CELLMODEM-M1 4G based LTE-M cellular modem(not included).Note that an Enphase Mobile Reliable Connect cellular modem is required for all Ensemble installations. • Durable NRTL-certified NEMA type COMPLIANCE 3R enclosure Compliance,Combiner UL 1741, CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 SHEET NAME O Production metering:ANSI C12.20 accuracy class 0.5(PV production) UL Five-year limited warranty Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 DATA SHEET UL listed LISTED I o learn more about Enpnase Offerings,visit enonase.com ^ To learn more about Enphase offerings,visit enphase.com v E N P H A S E ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the ` E N P H A S E SHEET SIZE trademarks of Enphase Energy,Inc.Data subject to change.2021-05-20 ANSI B 1111 X 17" SHEET NUMBER DS-04 SOLAR DONE RIGHTO ENGINEERING SERVICES,LLC 1 SOLARMOUNT .. U N I RAC620 N.WYMORE ROAD, OPTIMIZED COMPONENTS 1 1 ' 1 1 1 1 1 1 1 1• ' 1 1 1 '1 1 •1 1 INTEGRATED BONDING&PRE-ASSEMBLED PARTS 1• 1 • •1 , 1, 1 1 • , I I 1• • •1 , I 1 Components are pre-assembled and optimized to reduce installation steps and save --- labor time.Our new grounding&bonding process eliminates copper wire and grounding INTEGRATED BONDING 1 1 1• 1 ,• 1, ,•• 1 1 1• , •, •1 •, •1•• 1 , •1 1 ,1 1•, straps or bonding jumpers to reduce costs.Utilize the microinverter mount with a wire MIDCLAMP --- management clip for an easier installation. END VERSATILITY --• ;t CAPS ONE PRODUCT-MANY APPLICATIONS Quickly set modules flush to the roof or at a desired tilt angle. Change module INTEGRATED BONDING orientation to portrait or landscape while securing a large variety of framed modules on SPLICE BAR flat,low slope or steep pitched roofs.Available in mill,clear and dark anodized finishes to outperform your projects financial and aesthetic aspirations. AUTOMATED DESIGN TOOL Digitally - DESIGN PLATFORM A YOUR SERVICESTA7E ' Creating a bill of materials is just a few clicks away with U-Builder,a powerful online ® It TEGRATED BONDING tool that streamlines the process o designing a code compliant solar mounting system. L FOOT w/T-BOLT • Save time by creating a user profile,and recall preferences and projects automatically ® Date: when you log in.You will enjoy the ability to share projects with customers;there's no 2022.03.0 need to print results and send to a distributor,just click and share. FRONT INTEGRATED BONDING ' ' ► TRIM MICROINVERTER MOUNT w/ • 1 . WIRE MANAGEMENT BONDING&GROUNDINGLU •• MmUL2703SYSTEM MECHANFIRECLASIFI FIRE CLASSIFICATION UNIRAC CUSTO AER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ' 1 1 1 • iI k L I n kI I 1 1 1 UNMATCHED CERTIFIED ENGINEERING BANKABLE DESIGN PERMIT i i �. i i� i, . i i �. EXPERIENCE QUALITY EXCELLENCE WARRANTY TOOLS DOCUMENTATION TECHNICAL SUPPORT CERTIFIED QUALITY PROVIDER BANKABLE WARRANTY Unirac's technical support team is dedicated to answering Unirac isthe only PV moon ing vendor with ISO certifications Don't leave your project to chance,Unirac has the financial questions & addressing issues in real time. An online for 90012015, 140012 15 and OHSAS 18001:2007, strength to back ur products and reduce your risk.Have peace FAST INSTALLATION. UPERIOR AESTHETICS library of documents including engineering reports, which means we deliverthe highest standards for fit, of mind knowingyou are receiving products of exceptional stamped letters and technical Jata sheets greatly form, and function. These certifications demonstrate our quality.SOLARM UNT is covered by a twenty five(25)year ' simplifies your permitting and prof ct planning process. excellence and commitment to first class business practices. limited produdw rmntyandafive(5)yearlimitedfinishwarranty. OPTIMIZED COMPONENTS • VERSATILITY • DESIGN TOOLS • QUALITY PROVIDER PROTECT YOUR REPUTATI N WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE A14D A SUPERIOR SUPPLY CHAIN PUB2017FEB28-PRINTED i Castillo Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA#28345 620 N.WYMORE ROAD, ■■ ; SOLAR ; SUITE 250, 89-2 MAITLAND,FL 32751 ■■■ � � TEL:(407)289-2575 ERMOCRATES E.CASTILLO-FL PE 52590 MOUNT INSTALLATION GUIDE ; PAGE COPYRIGHTED BY ■■ ' CASTILLO ENGINEERING SERVICES,LLC SMREVISIONS --------------------------------------------------------------------------------------------------------------------------------------------- DESCRIPTION DATE I REV 4n PROJECTINSTALLER G T.e /N o�k ... S U N P R :. Digitally BONDING MIDCLAMP ASSEMBLY BONDING MIDCLAMP ASSEMBLY BONDING RAIL SPLICE BAR RAIL TO L-FOOT w/BONDI NG T BOLT nn.ers igna$re •° Ermocrate Bonding Hardware creates bond between splice Serrated flange nut removes L-foot anodization o',STATE OF :��; S E P:1.. 0 Aluminum mid clamp with stainless steel bonding pins that pierce module frame 0 bar and each rail section to bond L-Foot to stainless steelT-bolt CBStIIIO anodization to bond module to module through clamp ,,,oNA;„,,. Aluminum splice bar spans across rail gap to Serrated T-bolt head penetrates rail anodization °"_o�,t,1=!.o°"Pt Date: © create rail to rail bond.Rail on at least one side to bond T-bolt,nut,and L-foot to rounded 2022.03.0 Stainless steel nut bonds aluminum clamp to stainless steel T bolt ® 9 of splice will be grounded. SM railer 2 15:36:01 © Serrated T-bolt head penetrates rail anodization to bond T-bolt,nut,clamp,and Note: Splice bar and bolted connection are modules to SM rail non-structural. The splice bar function is rail alignment and bonding. PROJECT NAME D=_ s,. E o Note: �4l NUT W/CAPTIVE �° i SOS/ W Q Cf7 Only one lug per module row required LACK WASHER ��. U M BOND 'T-BOLT' ©��F�•P��`c vt OpAFR�/R W W _j E p ,_, J�� F W W K SYSTEM BONDING BONDING RAIL �� O W z � OUND MICROINVERTER SPLICE BAR © Q W ® Option 1: MOUNT W W Ground Through SEE NOTE WEEBLUG(OR ILSCO LUG),- M ~ Enphase Trunk Cable '� Q LO Of - -- — _ � 0 BONDING MICROINVERTER MOUNT RACK SYSTEM GROUND OHex nut with captive lock washer bonds metal O WEEB washer dimples pierce anodized rail to microinverter flange to stainless steel T-bolt create bond between rail and lug BONDING MIDCLAMP Serrated T-bolt head penetrates rail anodization ASSEMBLY ` ,'-`. © Solid copper wire connected to lug is routed to SHEET NAME to bond T-bolt,nut,and L-foot to grounded A provide final system ground connection. � C SM rail :,stem ground including racking and .may be achieved through the trunk cabi sed wh:_ secured to DATA SHEET Option 2:Ground Lug w/ RAIL TO L-FOOT of approved microinverter systems. See pag, the side of the rail. See page K for details Bare Copper Wire w/BONDINGT-BOLT _ details SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-06 Castillo Engineering SOLAR DONE RIGHT® MEN I No CASTILLO ENGINEERING SERVICES,LLC COA#28345 620 N.WYMORE ROAD, © SUITE 250, © • • • • angled MAI LAND,FL 3 TEE L:(407)289-2575 S=510 wider throat, and an insert for easy installation and best fit for 75 ERMOCRATES E.CASTILLO-FL PE 52590 The Right • . • profiles. COPYRIGHTED B Y CAS ENGINEERIN G Y A AND SEEVICES,LLC POV REVISIONS50 VRED S—S—N Clamp DESCRIPTION DATE REV The • ht • The S-S-Nand s-S-N Mini clamps are each supplied with !.57,n the hardware shown to the right.Each box also includes [39.9rnm] Clamp a bit tip for tightening setscrews using an electric screw FP gun.The S-5-N is a structural aluminum attachment introduces the new and clamp,compatible with most common metal roofing PROJECT INSTALLER improved • materials(excluding copper).All included hardware is �� design features an inn• 300 series stainless steel.Please visit www.5-5.com for that ensures a •- • • more information including CAD details,metallurgical ot E compatibilities,and specifications. » . . .. . . . E S U N PR older ones. s 5-5!1 holding strength is unmatched in the industry. o ci LO �,o`E;'crisri4'•.,, Digitally 0 The S-5-N (standard)clamp is the • Fits Panels Up to .82" igna$re Ermocrate • best choice for snow retention ; (Note:Not to scale) 0.79in cc Lee J C E • • • load-critical [20.1 mm] -.T�...o..ow2�• • • r 82 0,/ONAtEp Castillo 4-1 applications.It is designed for useDate: • • popular 2022.03.0 roofs,E metal including: :gym.„�..oao. 2 15:36:02 • —Nail Relief 4-6 Easy • •• S-5-N Mini Clamp V. • Roofing', • PROJECT NAME ®Meridian, 1.57in [39.9mm] 11 Schlebach 1" Nail Strip,and roofing •" • • (NOTE:Seams that exceed maximum allowance at the widest part of the seam will require hand crimping to allow the clamp to fit). CO 1' ' J FEATURES AND BENEFITS E 1116. • Mini It Ease of Installation...in 1...2...3 W J Clamp ^a w IL Installation Simplified S-5-N is still just as quick and easy to -4Q w The S-5-N Mini • • • installation • special tools install as other S-5 clamps.But now,we've angled the setscrews )_—E — � w• • toward the installer,allowing easier access with a screw gun, me • • standard simplifying tool removal once the setscrew has been tightened- the •but • and has one Fits seam profiles having base of ensuring the clamp sits straighter on the seam.Choose the S-5-N for W Z 11� • • • setscrew a non-penetrating solution that protects the roof while providing Q w rather • riimensin excellent holding strength. •-. • • • • rooftop •• • clamp body • 300 • 20.1 minm [30.Om^7] J O signs, 9 Q � O 2 IL . . . _&strength - rooftop lighting,conduit, . insert to . cilitate . . - • load applications*, • _ ensures •• 5-5!®Warning!Please use this product responsibly! Distributed by Products are protected by multiple U.S.and foreign patents.Visit the website at www.5-5.com for SHEET NAME clamp position • �• complete information on patents and trademarks.For maximum holding strength,setscrews should be tensioned and re-tensloned as the seam material compresses.Clamp setscrew tension should be -S-51 Mini clamps are not compatible with,and should not be usei •• verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ge steel, with S-51 SnoRail-/SnoFence-or ColorGarce snow retention _ and between 130and 150 inch pounds forall other metals and thinnergauges ofsteel.Consult the S-51 DATA SHEET •• website at www.5-5.com for published data regarding holding strength. laaaa Copyright 2019,Metal Roof Innovations,Ltd.5-5!products are patent protected. 5-51aggress-i lyprotects its patents,trademarks,and copyrights,Version 020619. SHEET SIZE S5_Pmduct-Sheet_SSN NEW_2.O v4.indd 1 2/6/19 3:37 PM S5_Pmduct-Sheet_S5N_NEW 2.0 v4.indd 2 2019 3:37 PM ANSI B 1111 X 17" SHEET NUMBER DS-07 Castillo Engineering ® SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC AQL IRONRIDGE QBase° Mount quICktvAount' QBASE SUITE20 620 N.WYMORE ROAD, SUITE 5 , MAITLAND,FL 32751 TEL:(407)289-2575 ERMOCRATES E.CASTILLO-FL PE 52590 COP BY Build Your System, Your Way CASTIIL O ENGINEERING SERVICES,LLC The QBase°Mount is a strong and versatile base-and- 1.25 REVISIONS post mounting system with various post height option;. DESCRIPTION DATE REV The components are available separately and combined to build a custom Solution that best suits your project. 1 (Formerly sold as QM,LSH and QMQDM kits or BTO) The QBase°Mount is made of super-strong cast aluminum, with four gussets to support 8 post heights 2 PROJECT INSTALLER from 3.25 to 17.5"—for a wide variety of roof types and 375"OA installations. QBase°Mount's versatility and superior strength will provide decades-long confidence. 3 ... 0 t 1.50" S U N P RV:. .50" This component is part of the QuickMounts E:'crisri4., Digitally product line. Attaches to Roof Deck or Structural Member nn.ers igna%Ire When utilized as a rafter-attached mount,two 5/16"x3" 4 -' Ermocrate 9••, STATE OF :�/ C C stainless steel lag screws with a minimum of 2"embedment .32II 0•.< r:ac J e into the structural member are recommended.For non-rafter gs Oryp E J°' Castillo Stainless steel attached applications,consult with a Structural Engineer to Date: [�PDM rubber rack attachment specify the type,size,and quantity of roof screws. sea Is top ofipost`' _ hardware " �my� oao 2022.03.0 ' 2 15:36:02 ! C) `�► PROJECT NAME Oe Detachable post fastens to 4.00° W J_ oNp QBase•Mount with in€hided bolt 2.50" C) Q I- QBase•Mount supports Z Of co multiple post heights up LJJQ W ILLto 17.5 in€hestall 8 Available Post Heights _ iY W Posts include post-to-rack hardware,with sizes available in U) U 3.25",4.5",6.5",8.5",11.5",12.5",14.5",and 17.5". w Z 0 MOUNT HEIGHT IS POST LENGTH + 1/2" POST LENGTHS AVAILABLE IN w i� ,. D�� THE FOLLOWING SIZES: Q Lo 0 Fourgusse[s subsGi3ntially u 3.25",4.5",6.5",8.5", 11.5", LID � Choice of improve load capacity = ILL 2-or4-bolt DEPARTMENT OF BUILDING AND SAFETY 12.5", 14.5", 17.5" mounting �:- t Fi,(mwA ITEM NO DESCRIPTION R t I I.DING CONlAtLSSION 1 CAP SCREW,5/16"X1"W/1"CAPTIVE WASHER SHEET NAME 44I. 2 WASHER,SEALING,5/16"ID X 1-1/4"OD,EPDM E30NDED Eta us 7i� DATA SHEET Best-in-Class Testing&Approval 3 POST, 1-1/4"OD X VARIED HEIGHT ABASE MOUNT Components have been formally approved by the City of LA 4 QBASE, 1-1/4"ID Intertek (LARK#26194)and the State of Florida(FL#29846). L A DO NOT SCALE DRAWING SHEET SIZE 5 CAP SCREW,HEX HEAD,5/16"X3/4" wE,HT 1.161 lb: SHEETI OF ANSI B ©2020 QuickMount PV All rights reserved.Visit w .quickmountpv.com or call 1-800-227-9523 for more information. QBASE MAN Rev 1.0 Nano 11" X 17" SHEET NUMBER DS-08 Castillo p neeri Enging SOLAR DONE RIGHTO CASTILLO ENGINEERING SERVICES, LLC Quick&Aount620Chemlink E-Curb Flashing Installation InstructionsSUITE20 N.WYMORE ROAD, SUITE 50, MAITLAND,FL 32751 Find more information at www.chemlink.com/index. h /chemlink roducts/e-curb-s stem. ERMOCRATES E(QCASTILLO FL PE 52590 Installation Tools Required: Drill and impact gun with appropriate bit and driver for selected fasteners, one tube of p p p Y sealant compatible with roofing materials, pencil,chalk line. E-Curbs are designed for use on granulated modified bitumen,asphalt and coal tar B.U.R.(built up roofing). E-Curbs are COPYRIGHTED BY CASTILLO ENGINEERING specified for PVC,PIB,and TPO single ply roofing membranes. E-Curbs are highly versatile for sealing penetrations around SERVICES,LLC Note:The QBase Mount ships without fasteners, allowing the project engineer to specify the fastener that best fits the solar panel mounts,HVAC,electrical,and any type of structural supports. TPO Primer is required for use with TPO. project requirements. Prior to installation insure you procure the appropriate type, size and quantity of fasteners for REVISIONS your application. For rafter attachment, use two 5/16"x 3"Stainless Steel lag screws, ensuring minimum penetration of DESCRIPTION DATE REV 2"into the structural members Materials Required:Chem Link's 5"E-Curb,M-1 Structural Adhesive/Sealant,1-Part Pourable Sealant PROJECTINSTALLER SUNPR - dE' '--- Digitally CAST,��p igna�re Ermocrate S E Castillo Locate the desired mount placement per the plan set.The mount can Drill pilot holes for the fasteners based on American Wood Council Install QBase to structural member. For Seal around the base of mount using Apply three 1/4" beads of M-1 to the flat ;E Date: be attached to structural members or direct to the roof deck based on recommendations.Make sure to drill perpendicular to the roof. more details refer to the QBase Low Chem Link's M-1. Coat the QBase,bolts base of both E-Curb sections. 2022.03.0 site-specific criteria.Using the base as a template,mark the penetration Backfill the pilot holes with a sealant compatible with roofing Slope installation instructions. and post with M-1 to 3"above roof line. 2 15:36:03 points with either a pen or light drilling.When attaching to a structural materials. member,use two opposing hales on the base plate,parallel to the struc- tural member. PROJECT NAME w J oo I i , 71 F/71 [. A w J r' Q W ILL �I tfanut W C) LL1 z LL I� Q w I' Place E-Curb sections to form a circle Apply M-1 around circumference of Fill the E-Curb cavity to the top with W of 0- around the QBase, making sure to lock E-Curbs and where the two sections Chem Link's 1-Part solution. Q Lo Of Prior to attaching the base to the roof, place the grade-8 hex Attach the top hardware to the top of the post.This ensures them together. Press firmly in place intersect. Use the wooden spatula to = LO 0 bolt into the bottom of the base.Fully seat the post into the the post will be sealed from weather exposure before racks are until excess adhesive extrudes from the spread the sealant to form a smooth LID ILL base,using slip-joint pliers if necessary.Attach the base and installed.You are now ready to flash the mount,roof around it, outside edges. surface. post assembly to the roof with the fasteners specified for the and attach racking.For built-up roofs and membrane roofs,be project. sure to use manufacturer-specified flashing methods or utilize the services of a certified roofer. SHEET NAME For additional Information refer to the ABASE Tech Tips: 0113ase Tech Ti Florida Product Approval,2020 Code: FL29846-R1 NOTE:Be sure to thoroughly read and follow manufacturer instructions for installing Chem Link's E-Curb Penetration System. DATA SHEET LA RESEARCH REPORTS(LARR): Approved for use in the City of Los Angeles per LARR#26194 Find instructions here:www.chemlink.com/e-curb SHEET SIZE BI 7.2.3-5_1 Jan-2017,Rev 3 ©2020 QuickMount PV All rights reserved.Visit www.quickmountpv.com or call 1-600-227-9523 for more information. ABASE MAN Rev 1.0 ANSI B 11" X 17" SHEET NUMBER DS-09 Castillo p Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC _ COA#28345 620 N.WYMORE ROAD, SUITE 250, E CuR6°SYSTEM Step 1 MAIE LAND,FL 32751 HEM LINK Remove all previously applied caulk, mastic, cement, TEL SERVICE asphalt, and other contaminants from penetrations ERMOCRATES E.CASTILLO-FL PE 52590 SOLAR PENETRATION SEALS with a wire brush. Clean all smooth substrates with COPYRIGHTED BY ASOPRE IN GROUP COMPANY isopropyl or denatured alcohol. Brush away all gravel CASTILLO ENGINEERING or loose granules. Seal the base of each penetration SERVICES,LLC Technical Data Sheet Polyether Technology CSI Section No. 07 1213 with M-1. Coat penetrations with M-1 to 3"above the REVISIONSroof line. - -_r DESCRIPTION DATE REV CHEM LINK Last Revision: 07/20/20 Construction &Maintenance Document No. DS1350S Telephone:800-826-1681 Step 2 Fax:269-679-4448 f Is_ % ) Hold a section of E-Curb, flat side up, and apply NT 353 E. Lyons Street a 1/4" bead of M-1 to the entire bottom perimeter. Schoolcraft, MI 49087 - ' ` Apply 1 additional 1/4" bead of M-1 down the center PROJECT INSTALLER www.chemlink.com — of the section. Do not tool the beads flat. Place the �- E-Curb section on the roof surface to form a half circle j Product Description �_�- around the penetration(s). Press down firmly until M-1 —'-. ` extrudes from the outside edges. E-Curb penetration seals replace old-style metal pitch U N P R pans with versatile, precast components and pourable sealants. CHEM LINK's E-Curb system can usually be ._.•__ installed in under 15 minutes and never requires flashing or mechanical attachment. Step 3 y Digitally Apply M-1 to the second section of E-Curb as describedY. E• ••4 E-Curbs are designed for use on granulated modified above. Place the second section of curb on the roof ` :' �o *zs i8na$re (( surface to form a circle with the first section. Press ,,r Ermocrate bitumen, asphalt and coal tar B.U.R. (built up roofing). 1 9, STATE OF E-Curbs are specified for PVC, EPDM, PIB, and TPO firmly in place until excess adhesive extrudes from the S E p E-Curb System Components outside edges. Apply a bead of M-1 around the outside II ,soNA;E�,`` Castillo single ply roofing membranes. TPO Primer is required .E-Curb exterior rings,straights,and corners. base of the installed E-Curb,and tool to form a smooth Pt Date: for use with TPO single-ply roof membrane. fillet. For non E-Curb penetrations seals, add M-1 to _ C°mg 2022.03.0 •M-1 Structural Adhesive/Sealant used for bonding the E-Curb components,sealing and priming the ,arfjoint surfaces and tool smooth. 2 15:36:03 When installed properly, this system forms a durable, waterproof rubber seal around penetrations. An penetration. extended manufacture warranty against leaks is •1-Part"moisture cure"pourable sealer,used to form a PROJECT NAME activated with submittal of a completed warranty card. durable,water-tight seal around the roof penetration. Step 4 Cut tip off 1-Part cartridge at widest point on plastic Special Characteristics E-Curb precast form components are composed of light nozzle and pierce the foil seal. Insert into caulking gun •Rapid installation-"Slip-fit"light weight curb design weight nylon resin. The E-Curb is 2-inches high and is and pump E-Curb full. When using a 1-Part pouch, - CV remove cap,pour,squeeze out excess air,and reseal. reduces labor significantly. available in a variety of shapes and sizes. q ', J_ 00 Standard sizes include bisected circular pieces with Note:To provide an adequate rubber seal,maintain f p� •Excellent adhesion to most roofing materials. p 1" distance between penetrations and inside edge of - U Q � •No flashing or mechanical attachment required. inside diameters of 3,4, 5,6 or 9 inches; corner pieces M the E-Curb. z •Service Temperature-40°F to 200°F(-40°C to 93°C) with a 2-inch radius; straight pieces in 3-inch or 8-inch w J •1-Part®accommodates movement and is suggested lengths; and a 4.5"x 3.4" rectangle. The outer surface W Q ` ILL for use on all granulated membranes and details is impervious to ice, corrosion, UV(ultraviolet)light and _ � W with excessive movement. ponding water. All properties described in this document are derived from testing conducted in laboratory conditions.Properties and performance (n I.— Q • For sloped roof applications, substitute DuraLink®50 will vary depending on environmental conditions and application technique.Test and evaluate to determine appropriate usage. Lli Z 0� non-slump adhesive/sealant for 1-Part and M-10 Visit www.chemlink.com for the Safety Data Sheet,Technical Data Guides and full warranty for this product. 0� Q W_ Restrictions M-1 Structural Adhesive/Sealant is a durable, self- LIMITED WARRANTY:CHEM LINK warrants this product's performance,provided it is properly stored and applied within 1 year. w [)f 0- Please contact customer service for application fixturing moisture cure mastic. Cartridges of M-1 are If this CHEM LINK material is proved to be defective,return remaining product and purchase receipt for refund or replacement J � � guidelines with temperatures below 32°F(0°C). supplied in each E-Curb Kit. Components are also sold of product exclusive of labor or cost of labor.This is the sole and exclusive remedy for defects or failure of this product. User Q � O •guidelines not apply h rain is anticipated within 4 hours. separately. must read and follow the direction of the current Technical Data Guide and SDS prior to product use.User determines suitability = to ILL •Do not use on Hyn is a ti smooth APP modified 1-Part is a highly flexible, self leveling moisture cure of product for intended use and assumes all risks. Manufacturer shall not be liable for damages (including consequential or incidental damages)in excess of the purchase price, except where such exclusion or limitation is prohibited by state law. bitumen membrane. For smooth APP,torch down pourable sealer that eliminates mixing. It is also 100% THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,WRITTEN OR ORAL, STATUTORY, EXPRESS OR IMPLIED a target of granulated APP before installation. solid rubber, has a very low VOC content, will not melt INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE;except for the above •TPO Primer must be used for TPO applications. or shrink,and is resistant to deterioration. It is supplied express warranty given by manufacturer,the product is sold with all faults. CHEM LINK SHALL NOT BE RESPONSIBLE FOR •Do not prime bonding surfaces with asphalt primer. in 10.1-oz and 28-oz cartridges or 1/2 gallon pouches. SHEET NAME THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENTOR ANY OTHER INTELLECTUAL PROPERTY •Do not use asphalt cement as a"night sealant". Unused sealant can be capped and reused. RIGHTS HELD BY OTHERS.This warranty gives you specific legal rights,and you may also have other rights in the U.S.which Use M-1 for this purpose. Made in the USA-ISO 9001:2015 certified vary from state to state. For warranty claim information,call 800-826-1681. DATA SHEET •E-Curb kits are designed to contain enough 1-Part to fill each curb with displacement in consideration. A American IMUffNAT,oNALRefer to our penetration calculator under contractor [911111anufac!"ers Architectural ����„� C111HEmMUNK) SHEET SIZE resources at chemliink.com to verif volumes. AEMBEATION Y Association MEMBER SOPREMA GROUP COMPANY ANSI B 11" X 17" SHEET NUMBER DS-10 Castillo p gi Enneering SOLAR DONE RIGHT® CASTILLO ENGINEERING SERVICES, LLC COA#28345 620 N.WYMORE ROAD, SUITE 250, MAITLAND,FL 32751 TEL:(407)289-2575 ERMOCRATES E.CASTILLO-FL PE 52590 Ilk r� C111"HEMLINK COPYRIGHTED BY C,HEMLINK\ Structural 1 =Part CAS SER ENGINEERING VICES,LLC V PANY SER Adhesive/Sealant Pourable Penetration Sealant ��P;SOPREMA'GROUP COM REVISIONS POLYMER INNOVATION DESCRIPTION DATE REV Technical Data Sheet Polyether Technology CSI Section No. 07 92 13 Technical Data Sheet Polyether Technology CSI Section No. 07 14 16 CHEIM LINK Last Revision: 1/07/21 CHEM LINK Last Revision: 04/20/18 Construction&Maintenance Document No.DS1270 Construction&Maintenance Document No.DS1428 Telephone:800-826-1681 Telephone:800-826-1681 PROJECT INSTALLER Fax:269-679-4448 Fax:269-679-4448 353 E.Lyons Street 353 E.Lyons Street Schoolcraft,MI 49087 Schoolcraft,MI 49087 www.chemlink.com www.chemlink.com U N P R ' Product Description Advantages Product Description U.S. PATENT NO. RE41,586 E P 9 1-Part is a moisture curing, pourable sealant designed M-14D is a moisture curing,polyether adhesive/sealant •Solvent free,100%solids will not shrink for use in pitch pans and warranted ChemCurb/E-Curb Advantages designed for applications in damp,dry,or cold climates. •Non-slump,applies vertically and overhead penetration seals. 1-Part is suitable for application •Solvent free,1 iDO%solids will not shrink "�dsn ., Digitally M-10 is solvent free and contains no isoc anates. •20 minute skin over ° ..N g y y in damp, dry, or cold climates. 1-Part is solvent free, •20 minute skin over ' M-10 will not shrink upon curing,will not discolor when •No out gassing on dam surfaces „°.szs igna$re 9 9 P contains no isocyanates and will not shrink upon curing. •No outgassing on damp surfaces = Ermocrate exposed to UV light,and can not"out-gas",or bubble •Good color stability,will not suntan 1-Part can not"out-gas" or bubble on damp surfaces •Good UV stability,will not suntan 9•. STATE OF ._•; on damp surfaces as urethane sealants often do. •Paintable within 24 hours(See limitations) as urethane sealants often do. 1-Part has resilient •Paintable within 24 hours(See limitations) °F~`,oq;o"•'�°` S E M-1®is capable of joint movement in excess of 35% •Gun grade,no special tools or mixing re uired "elastomeric"properties erties and excellent adhesion to most •Self leveling,nos special tools or mixing required ''ss;° Castillo in both compression and extension. M-1®can be used g P 9 q P p g' p 9 q ;t Date: Application at temperatures as low as 32°F(0°C) construction materials. 1-Part can be used effectively Application at temperatures as low as 32°F(0°C) effectively in many difficult construction site conditions •Made in the USA-ISO 9001:2015 certified in many difficult construction site conditions and cures •Extended warranties available ,m''T' 2022.03.0 such as wet or dry climates and at temperatures as low in wet or d climate conditions and at low temperatures "= '"`"�' "'""°°°" as 32°F 0°C. dry P 2 15:36:04 ( ) (32°F/0°C). 1-Part's low durometer accommodates Applicable Performance Standards Colors urethane sealants.reater movement in penetration seals than typical ASTPROJECT NAME • Uses C920,Type S,Grade NS,Class 35 _,; EIUr NK White,Gray,Tan,Limestone&Black Uses E Ti, la G,A&O �. *Color matching is available in batch quantity only Cure Time Colors • ASTM E84,ClassA � - 1-Part is a moisture cure sealant. Rate of cure is White,Gray&Black • ASTM D4586 Spec dependent on atmospheric conditions. Curing proceeds • Federal Specification TT-C-541,0 y Type II,Class B at a rate of 1/4"a week at 70°F(22°C)and 50%Relative 00 �� J � • Corps of Engineers CRD-C-541,Type II,Class B • Canadian Standards Board CAN 19,13-M82 Humidity. Lower temperature and humidity will inhibit CHEMUNK L J the rate of cure. Higher temperature and humidity will Q • SWIG Institute Validated(Sealant Waterproofing and �,, 9 P tY U � Restoration) :.:<,: accelerate rate of cure. Depths of more than 2"will cure z M • Miami Dade County,Florida. NOA No.:19-0709.02 ,',n through in 2 to 3 months. LLI J Expiration Date:09/19/2024 DO NOT install if rain is anticipated within 4 hours. Q `W LL Regulatory Compliance Packaging Regulatory Compliance Packaging IY W• Conforms to OTC Rule for Sealants and Caulks •5 oz Squeeze Tube(148 ml) Conforms to OTC Rule for Sealants and Caulks •10.1 oz(300 ml)Gray only i.— • Meets requirements of California Regs: ;,' 36 tubes/carton,40 cartons/ allet �/ _ ,� P Meets requirements of California Regs: 24 cartridges/carton,45 cartons/pallet w Z � CARB,BAAQMD and SCAQMD e. o •10.1 oz(300 ml) CARB,BAAQMD and SCAQMD - Other colors available by special order 0L Q W • This product does not contain cancer causing sr 24 cartridges/carton,es/carton,45 cartons/ allet This product does not contain cancer causing chemicals �,,;,.. 9 P P 9 -28 oz(825 ml)Gray only w � chemicals listed in California Proposition 65. �; •20 oz(600 ml) listed in California Proposition 65 12 cartridges/carton,40 cartons/pallet M • Conforms to USDA Requirements for Non-food Contact *,_• 12 sausages/carton,40 cartons/pallet Conforms to USDA Requirements for Non-food Contact • Other colors available by special order Q � � •28 oz(825 ml) • •1/2 Gallon Pouch Gray,White,&Black O 12 cartridges/carton,40 cartons/pallet _ 4 pouch/carton,48 cartons/pallet = to � Green Standards: White only-Other colors available by •20 oz sausages,2 and 5 gallon pails or 50 gallon © � Q special order Green Standards: drums available by special order •LEE=D 2.2 for New Construction and Major •2 and 5 gallon pails or 50 gallon drums Renovations: p„1„„„ available by special order •LEED 2.2 for New Construction and Major Renovations: Low Emitting Materials(Section 4.1)1 Point ATTENTIONICAUTION Low Emitting Materials(Section 4.1)1 Point SHEET NAME IRRITANT •NAHB Model Green Home Building Guidelines: ATTENTIONi�A6°:' •NAHB Model Green Home Building Guidelines: 5 Global Impact Points 5 Global Impact Points emu DATA SHEET NATIONAL •VOC Content:less than 19 rams/liter ASTM D2369 American VOC Content:less than 17 grams/liter ASTM D2369 � 9 IIII1I ROOFINGMIAMI•DADEC lm ��coGIFING oIs EPA Method 24 tested at 240°F/115°C Ah [a rIan LecturersMINATIONAL ASSOCATIORs7 SEPA Method 24(tested at 240°F/115°C) �Ne, � moN ( ) ManufacturersASSOCIATION.. tut! MEMBER Association MEMBER 9001:2008 SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-11 Castillo Engineering SOLAR DONE RIGHT® CASTILLO ENGINEERING Residential Optional Calculation 25-09-1997 SERVICES, LLC COA#28345 rS—A Version 2011 L 620 N.WYMORE ROAD, STEP 250, 1 Article 220.82(B)(1),(2) Marc Jones Construction,LLC Sunpro Solar SUITE FL 2751 sq.ft W 1708 General Lighting load 5,124 VA 0 M TE LAND,FL 375 9 9 TEL:(407)289-2575 4 Small Appliance 6,000 VA 0 ERMOCRATES E.CASTILLO-FL PE 52590 1 Laundry circuit 1,500 VA 0 COPYRIGHTED BY Gen.Lgt,Sm App.&Laun.Load 12,624 VA 21-02-202213:59 CASTILLO ENGINEERING SERVICES,LLC REVISIONS STEP 2 Article 220.82(C) 0 General lighting,Sm.Appl.&Laundry 12,624 VA DESCRIPTION DATE REV A/C Condenser&Fixed Electric Space Heating QTY Total 1 5 ton W 7,130 VA AHU 1 9.6kW W 10,800 VA 1 . Heating Load 1 7,440 VA A/C#2 W VA AHU 2 Select w VA Cry w CU Load 1 8,330 VA A/C#3 W VA AHU 3 Select w VA Qty W A/C#4 W VA AHU 4 Select w VA Qty w Electric Space Heat @ 65%<4,40%>3,vs.A/C @ 100% 8,330 VA A/C#5 W VA AHU 5 Select w VA Ql' w PROJECT INSTALLER STEP 3 Article 220.82(B)(3) Appliance Demand Load 8,566 VA 4,500 VA W 1 Water Heater 4,500 VA 1,400 VA w 1 Refrigerator 1,400 VA Dryer Demand Load 5,000 VA ,10 Freezer VA S U N P R 30 VA W 1 Dishwasher 1,030 VA Range Demand Load 10,000 VA 690 VA W Disposal VA 400 VA_ w R/Hood VA Service Demand 28,806 VA Digitally 1,630VA W 1 Microwave 1,630VA pdE,'GFST%40, ❑ 4,000 VA V Microwave VA Demand Load 120 A nn.ers igna$ire Ermocrate 170VA _. Mini Refrig VA 9 of STATE :�/. ❑ 400VA V Wine Or VA Neutral Demand 77 A s<<oR oP 2 S E ❑ 5,000 VA w Insta Hot VA OS�.NAtEp` Castillo 1,500 VA w Ironing Center VA Min.Service Req. 125 A Date: ❑ select 'r Jacuzzi Tub VA 2022.03.0 ❑ select w'.,,. Sprinkler Pump VA Min.Feeder size 2 "= . m„�.,,oao 2 1 5:36:04 ❑ select Well Pump VA Min.Neutral size 4 select Fountain Pump VA Eq.Girding Cond. 6 select Elevator VA ❑ Copper PROJECT NAME Pool Equip.Panel VA Apply Demand ❑ GATES VA No Demand ❑ 6 Other load 6 VA No Demand Total Appliance Load 8,566 VA STEP 4 Article 220.82(B)(3) J � Electric Clothes Dryers 5,000 VA w Q D7 STEP 5 Article 220.82(B)(3) Electric Ranges 10,000 W Col C demand 8000 Z Of M or Number of appliances w ~ J Cooktop Col B demand Q Lw ILL. ❑Check Box for Gas Range Cooktop Col B demand — Ly Oven(s) Col B demand U Oven(s) Col B demand wN z 0� Number of appliances 0 Dem.Factor 0. Q w Cooktop&Oven Demand Load 0- jmp1ids(a.comcast.net W »»»»»»»»»»»»»»»»»»»»»>««««««««««««««««««««««««< J C Pool Panel Feeder Calculation (See Note) A B N Continuous Non-continuous 2 LO O Continuous Motors 0 ...... 0 0 0 Motors Motnrs Non-continuous 0 ...... 0 0 0 select ❑ 240v select ❑ 240v Spa heater 11 kVA .... 0 0 select ❑ 240v select ❑ 240v Pool heater 3.5 ton 0 0 select ❑ 240v select . ❑ 240v Pool heater 5 ton 0 0 select ❑ 240v select ❑ 240v .•.. SHEET NAME Pool Light select V 0 ... 0 0 0 select a 240v select ❑ 240v Blower select IV 011 240v 0 0 0 other load 0 ❑ 240v 0 0 0 0.0 Motor Neutral Load DATA SHEET other load 0 ❑ 240v 0 0 0 ❑ Min.Copper Pool Feeder AWG A A A Max.Unbalanced Neutral Load Minimum Panel Rating A Phase Amperes Neut.load SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-12