Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
Florida Building Code Online https://Www floridabuilding.org/pr/pr_app dtl.aspx... tow BCIS Home Log In User Registration HotToplcs SubmltSurcharge k Stats&Facts Publications Contact Us ! BCIS S@e Map [ Unks Search % is rida rc Product Approval USER:Public User 1}"7"i..sfi 3`rxaY( . Product Approval Menu>P raduct o r Acpltatia n Search>A�plicatio n List>Agpllcatian History.>Applica i ion Detail _ o. e FL# RECEN90 FL10626-R23 Application.Type Revision Code Version MAR 1 2022 2020 . Application Status Approved St.Lucie County Permitting Comments i Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (800)766-34.0 mstieh@gaf.com I• Authorized Signature Robert Nieminen Ireith@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany,NJ 07054 (800)766-3411 Technica[QubstionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing " Subcategory Underlayments. s Q Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report Hardcopy Received i Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity' UL LLC Quality Assurance Contract Expiration Date 12/31/2024 Validated By John W.Knezevich, PE 20._ Validation Checklist-Hardcopy Received I Certificate of Independence FL10626 R23 COI 2021 01 COI NIEMINEN.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D4533(tear) ' 2015 ASTM D4798(weathering) 2011 ASTM D4869(water transmission) 2016 ASTM D5035(tensile) 2011 ASTM D6164 2011 1 Of 2 ASTM D6757 2016 3/15/22, 07:43 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx... FM 4474 2011. FRSA/TRI,6th Edition; 2018 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D- Date Submitted 12/16/2021 Date Validated 12/19/2021 Date Pending FBC Approval. 12/23/2021 Date Approved 02/08/2022 Summary of Products i FL# Model,Number or Description Name 10626.1 GAF Roof Roofing Underlayments for use insloped roof systems Underlayments for use in FBC non-HVHZ jurisdictions Limits of Use Installation Instructions Approved for use in HVHZ:No FL10626 R23 II 2021 12 14 FINAL ER GAF UNDERLAYMENTS FL10626- Approved for use outside HVHZ:Yes R23,Ddf Impact Resistant:N/A Verified By:Robert Niemien 59166 Design Pressure:+N/A/-442.5 Created by Independent Third Party:Yes Other:1.)The design pressure noted Evaluation Reports II in this application relates to one FL10626 R23 AE 2021 12 14 FINAL ER GAF UNDERLAYMENTS FL10626- particular underlayment system.Refer to R23.1)df ER Section 5.8.3 for details.2.)Refer to Created by Independent Third Party:Yes ER Section 5 for other Limits of Use. Beck N. Contact Us::2601 Blair Stone Road,Tallahassee FL aZ3UN Phone:c 5 487-1824 The Stale of Flor da is an AA/EEO employer.Copyright 2007-2013 State of Flodda::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your email address releasedilln response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by tradfional mail.If you have arty questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Departinent with an email address if they have one.The emanls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you area licensee undr Chapter 455,F.S.,please crick here. li Product Approval Accepts:, Credit Card 1 2 of 2 3/15/22, 07:43 I NEMO 1 etc. Certificate of Authorization#32455" 353 Christian Street,Unit#13 Oxford,Cr 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT i i January 1, 2021 I RE: Certification of Independence, Florida F.A.C. Rule 61G20-3 To Whom It May Concern: This letter serves to document the following in accordance with Florida,!F.A.C. Rule 1G20-3: i 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it.evaluates. .2. NEMO ETC, LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation repiorts are being issued. 4. Robert Nieminen,P.E.does not have,norwill acquire,a financial interest in any other entity involved in the approval process of the product. 5. Building Code Evaluations issued by NEMO I etc.and Robert Nieminen, P.E.are not,in any way,to be construed to mean or implythat NEMO I etc.or Robert Nieminen,P.E;.are the Designer of Record for any project on which the Evaluation Report is/was used for permitting or design guidance unless retained specifically for that purpose on a given project., I' �I �I Please contact our office with any questions. Robert Nieminen, P.E. President Florida Reg. No.59166 NEMO ETC,LLC PHONE: (203)262-9245 MW FAX: (203)262-9243 nCCxED�iEU ACCAm1TEV Obw CM9 www.nemoetc.com i NEMO 1 etc. Certificate of Authorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT, EVALUATION .O. GAF Evaluation Report 01506.04.08-R23 1Campus Drive IFL10626-R23 Parsippany, N1 07054 Date of Issuance:04/25/2008 (800)766-3411 Revision 23:12/14/2021 SCOPE: This Evaluation Report is issued under Rule 61G203 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products, described herein have been evaluated for compliance with the 7th Edition(2020) Florida Building Code sections noted - herein. `DESGRIPTIONA GAF Roof Underlayments faE use In"FBA non H1l�IZ�urlsdlct�ons�` .r;, � � � _� x -- - - LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products)changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility, location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Florida Product Approval Number(FL#)preceded by thewords"NEMO Evaluated"may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION;Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site.at the request of the Building Official. i This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M.Nieminen P.E. ; The facsimileseal:. ..9t : appearing was authorized by Robert Florida Regis No.59166 Florida DG4 ANE1983 `' Nieminen,P.E.on 12/14/2021.This does not serve as an g s -' ' t �, electronically.signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in;any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufactuiring or distributing products for which the evaluation reports-are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E,are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC,LLC I I I NEW etc. ROOFING COMPONENT.EVALUATION: SCOPE:1. Product Category: Roofing 11 Sub-Category: Underlayment Compliance Statement: GAF Roof Underlayments,as produced by GAF,have demonstrated compliance with the following sections of the 71 Edition(2020)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Liii mitations/Conditions of Use set forth herein. 2. STANDARDS: Pro a J a .w r. w FStadard ��" ' i t� Year _MOM _.... rt�C ._ m .y x . ter_. .. 1504.3.1 Wind resistance FM 4474 2011 1507.1.1,1507.2.4,1507.2.9.2/R905.1.1, Material standard ASTM D1970 2015 I, R905.2.8.2 1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ " Tear Strength ASTM D4533 2015 R905.1.1.1(2&3,Exception),R905.1.1.1(5) li 1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ Tensile strength ASTM D5035 2011 11905.1.1.1(2&3,Exception),R905.1.1.1(5) 1507.1.1.1(5)/R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1507.1.1/R905.1.1 Material standard ASTM D6757 2016 1507.3.3,R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018 1507.11.2 Material standard ASTM D6164 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: NT '.,'""' '�" t r Date Entl .EXamItli1ti01n x ..�,� { �RefererlGea" ? n.. „ ERD(TST6049) ASTM D1623&FRSA/TRI(Slippage) G34150.08.11 11/14/11 ERD(TST6049) ASTM D6164(GA) G4063d.01.14-2B-R2 01/07/14 ERD(TST6049) ASTM D6164(GA) G46160.09.14-3A 09/09/14 ERD(TST6049) ASTM D1970(GA) GAF-SC13285.03.17-3 1 03/01/17 ERD(TST6049) ASTM D1970(GA) GAF-SC13285.03.17-4 ,� 03/01/17 ERD(TST6049) ASTM D1970(GA) GAF-SG13285.03.17-1 03/08/17 ERD(TST6049) ASTM D1970(IN) GAF-SC16440.12.17 12/31/17 - Intertek(TST1558) ASTM D4869(Dadra,India) F8549.02-106-18 11/08/16_ NEMO(TST6049) Physical Properties(ON) 4q-GAF,-19-SSMBB-03.A 05/13/19 NEMO(TST6049) ASTM D1623 4p-DOW-I9-SSLAP-01.A-R2 10/01/19 NEMO(TST6049) ASTM D1970 4j-FTS-20-SSUDL-01.A 12/01/20 NEMO(TST6049) ASTM D1970 4j-GAF,,20-SSUDL-01.A 12/22/20 NEMO(TST6049) ASTM D4798,TAS 103 4j-GAF-20-SSUDL-02.A 03/15/21 MEMO(TST6049) ASTM D4798 4j-FTS-2I-SSUDL-02.A 06/09/21 PRI(TST5878) ASTM D226(OK) GAF-339-02-01 03/13/12 PRI(TST5878) Wind-Uplift GAF-434-02-01 09/16/13 PRI(TST5878) Wind Uplift GAF-434-02-03 . 09/16/13 PRI(TST5878) Wind Uplift GAF-434-02-04 09/16/13 PRI(TST5878) ASTM D4533(various) GAF-8i8-02-01 12/05/17 PRI(TST5878) ASTM D1970(AL) MSA-047-02-01 04/11/18 PRI(TST5878) ASTM D4533(Dadra,India) GAF-847-02-01 06/04/18 PRI(TST5878) ASTM D4533(Dadra,India) GAF-914-02-01 04/10/19 PRI(TST5878) ASTM D4533,D5035(VA) 376T0012 07/15/19 PRI(TST5878) ASTM D4533(Parzai,India) 376T0018 07/31/19 PRI(TST5878) ASTM D4533(Umerkui Kilvani,India) 376T0018 07/31/19 PRI(TST5878) ASTM D1970(AR) 376T0032 10/22/19 PRI(TST5878) ASTM D4533(Gujarat,India) 376T0058 02/18/20 NEMO ETC,LLC Evaluation Report 01S06.04.08=R23 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R23 GAF Roof Underlayments Revision 23:12/14/2021 Page 2 of 8 - I i NEMO etc xamination ' _ .. . Reference` . :_ PRI(TST5878) ASTM D226(S-CA) 376T0054 02/18/20 PRI(TST5878) ASTM D5035(various) 376T0103 .09/11/20 PRI(TST5878) ASTM D4533,D5035(Rajasthan,India) 376T01$1 12/22/20 PRI(TST5878) ASTM D4533,D5035(Gujarat,India) 376T0113 12/22/20 PRI(TST5878) ASTM D5035(Gujarat,India) 376T0146 03/11/21 PRI(TST5878) ASTM D4533,D5035(Rajasthan,India) 376T0161 05/07/21 PRI(TST5878) ASTM D226,Type 11 376T0192 09/16/21 NEMO Traceability FBC Cross-Listing • 04/22/20 NEMO Traceability FBC Cross-Listing 04/08/21 UL,LLC(QUA9625) Quality Control Service;Confirmation(AL) 05/04/20 UL,LLC(QUA9625) Quality Control Service Confirmation(various) 06/10/21 UL,LLC(QUA9625) Quality Control Florida BCIS Current I! I PRODUCT4. DESCRIPTION: 4.1 GAF Extended Dry-In Membrane ASTM D1970 Langley,BC Canada Liberty-SBS Self-Adhering Base/Ply Mt.Vernon,IN 4.2 Sheet ASTM D1970 Savannah,GA 4.3 StormGuard®Film-Surfaced Leak Barrier ASTM D1970(Table 1)1 Mt.Vernon,IN Savannah,GA Arkadelphia,AR WeatherWatch®Mineral-Surfaced Leak 4.4 ASTM D1970 Savannah,GA Barrier Tuscaloosa,AL Deck-Armor'"'Premium Breathable Roof 1507.1.1.1(2&3,Exception)/ 4.5 Deck Protection R905.1.1.1(2&3,Exception) Dadra,India I Dadra,India 1507.1.1.1(2&3,Exception), Gujarat,India 4.6 FeltBuster®Synthetic Roofing Felt 1507.1.1.1(5)/R905.1.1.1(2&3,C (CPP)Rajasthan,India Exception),R905.1.1.1(5) (MIP)Rajasthan,India Richmond,VA Spartanburg,SC 4.7 Shingle-Mate®Roof Deck Protection ASTM D226,Type II(Table 1) Pryor,Shaff Cer,CA 4.8 SiormSafeT Anchor Sheet 1507.1.1.1(2&3,Exception)/ North Bay,ON R905.1.1.1(2&3,Exception) Dadra,India 4.9 Tiger PawT"Premium Roof Deck 1507.1.1.1(2&3,Exception)/ Gujarat,India Protection R905.1.1.1(2&3,Exception) Parzai,India Umerkui Kilvani,India VersaShield®Fire-Resistant Roof Deck 4.10 Protection ASTM D226,Type II Conover,NC 4.11 Ruberoid®Mop Granule ASTM D6164 Savannah,GA FRSA/TRI,09-18 4.12 Ruberoid®Mop Granule FIR ASTM D6164 FRSA/TRI09-18 1 Savannah,GA i StormGuard®Film-Surfaced Leak Barrier has been found through comparative testing to have a lesser coefficient of friction than ASTM D225 roofing felt when tested at standard laboratory conditions. Agreement between purchaser and seller,'I s set forth in Section 4.3,Note 1 of ASTM D1970-15,should be established as to slip resistance. NEW ETC,LLC Evaluation Report 01506.04.08-1123 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION I FL10626-1123 GAF Roof Underlayments Revision 23:12/14/2021 Page 3 of 8 I • W., NEMOletc. 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. I 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1I505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the'prepared roof covering. 5.6 Allowable Roof Covers: ` t - TABLE 1 ROOF CovER OPTIONS;: J y: ,,, „ FBCSecttax. 13D7 2 15QT 3, ,, 35D7 4 and507 5 1507 7 I50T S and;15079, and Concrete 7t�e' Metal Slate or; Wood' Under(ayment �Phalt Mechanical Adhesive- 4' SlattelType� Shmgles xy Panels< 5hingles Shingles Shakes Yes Yes GAF Extended Dry-In Membrane Yes No No. Yes Yes YI s (Joint strips, Uoint strips, 11507.1.13/ 1507.1.1.3/ R905.1.1.3) R905.1.1.3) Liberty-SBS Self-Adhering Yes Yes Base/Ply Sheet Yes No No No No No isount .1s% 1507.1..1oint 3/ R905.1.1.3) R905.1.1.3) StormGuard®Film-Surfaced Leak Yes Yes Yes No No Yes Yes Yes (Joint strips, (Jolnt strips, Barrier R9051.13) R905113) WeatherWatch®Mineral-Surfaced Yes Yes . Leak Barrier Yes No No No No No 1507.11oint s/ 1507.1.1s, oint 3/ R905.1.1.3) R905.1.1.3) Deck-Armor-Premium Breathable . Roof Deck Protection Yes No No Yes Yes Yes No No FeltBuster®Synthetic Roofing Felt Yes No No No No No No -No Shingle-Mate'Roof Deck Protection Yes No No No . No No No No Tiger Paw-Premium Roof Deck Protection Yes No No Yes Yes Yes No No VersaShield®Fire-Resistant Roof Deck Protection Yes No No No No No No No Yes Yes Ruberoid®Mop Granule No (Cap Sheet in (cap sheet in No No No No No 2-plysystem) 2-ply system) See 5.6.1 Yes ® Yes (Cap Sheet in Ruberoid Mop Granule FR No (Cap Sheet in No No _ No No No 2-ply system) 2-ply system) See 5.6.1 i NEMO ETC,LLC Evaluation Report 01506.04.08-R23 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R23 GAF Roof Underlayments Revision 23:12/14/2021 Page 4 of 8 I' MEMO j etc. 5.6.1 Adhesive-set is limited.to use of following underlayment/tile-adhesive combinations. TABLE IA �1LLOINABLE UNDERLAY)}AENT�TILE Co r Underla`merit Adhesme a y Florida Product Approval Ruberoid®Mop Granule;Ruberoid®Mop Granule FR Dupont"Tile Bond'""Roof Tile Adhesive" FL22525 i 5.7 Allowable Substrates: TABLE Y SUBSTRATE C{PTIONS FOR ADHERE©UNDERLAYMENTS t Underlayment Applrgtionz Premed; �„, Substrates GAF Extended Dry-In Membrane self-adhering None plywood LibertyT"SBS Self-Adhering Base/Ply Sheet StormGuard®Film-Surfaced Leak Barrier self-adhering (Optional) plywood ASTM D41 Weather Watch®Mineral-Surfaced Leak Barrier LibertyTm SBS Self-Adhering Base/Ply Sheet StormGuard®Film-Surfaced Leak Barrier self-adhering None ASTM D226 felt,Type II Weather Watch®Mineral-Surfaced Leak Barrier Liberty"SBS Self-Adhering Base/Ply Sheet StormGuard®Film-Surfaced Leak Barrier self-adhering ASTM D41 metal.(flashing metal,valley metal, etc.) Weather Watch®Mineral-Surfaced Leak Barrier Ruberoid®'Mop Granule Ruberoid®Mop FR Granule hot asphalt ASTM D41 structural I concrete Ruberoid®Mop Granule GAFGLAS®#80 UltimaTM Base Sheet hot asphalt None or Ruberoid®20 Smooth Ruberoid®Mop Granule FR 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the ianufacturer's installation instructions,but—for mechanically attached base sheets-not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein(for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications- The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required.under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. z Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLC Evaluation Report 01506.04.08-1123 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION F1.10626-1123 GAF Roof Underlayments Revision 23:12/14/2021 Page 5 of 8 i I I fONEMOJetc. #1 Maximum Design Pressure=-442.5 psf. Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction Base Sheet: GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet,GAFGLAS#80 Ultima Base Sheet,GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping,of ASTM D3121 Type IV hot asphalt at 20 to 25 Ibs/square. Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. 5.8.3.2 Mechanically-Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that.required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively,the maximum design pressure for the selected assembly'shall meet-or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked With an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for enhancements. #2 Maximum Design Pressure=-45 psf. . Deck:_ Min. 19/32-inch plywood to -meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 UltimaT" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8,inch diameter tin caps spaced 9-inch o.c. at the min.4-inch wide side laps and 9-inch o.c.at two(2),equally spaced,staggered center rows in the field of the sheet. Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. #3 Maximum Design Pressure=-75 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.. Base Sheet: GAFGLAS® #80 Ultima'"" Base Sheet or Ruberoid®20 Smooth mechanically attached with 12 ga., min.1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch D.C. at the min.4-inch wide side laps and 8-inch D.C.at three(3),equally spaced,staggered center rows in the field of the sheet. Cap Sheet: . Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. #4 Maximum Design Pressure=-97.5 psf. i Deck: Min. 19/32-inch plywood to meet project requirements to satisfa Ition of Authority Having Jurisdiction. Base Sheet:. GAFGLAS® #80 UltimaTm Base Sheet or Ruberoid® 20.Smooth mechani i ally attached with 11 ga., min. 1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameteritin caps spaced 4-inch o.c. at the min.2-inch wide side laps and 4-inch o.c.at four(4),equally spaced center rows in the field of the sheet. Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. t NEMO ETC,LLC Ev,luation Report 01506.04.08-1123 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.10626-1123 GAF Roof Underlayments Revision 23:12/14/2021 Page 6 of 8 fONEMOJetc. 5.9 Exposure Limitations: w ' Maximum � Underlayment ^' � re pare d Ro� ov Expasu at�on7ypee days) Y 5 5 s r , Install ( e Deck-Armor"Premium Breathable Roof Deck Protection,FeltBuster®Synthetic Roofing Felt,Shingle-Mate®Roof Deck Protection,StormSafe'"Anchor Sheet,Tiger Paw-Premium Roof Deck Protection,VersaShield®Fire-Resistant Roof Deck Mechanically attached 30 Protection,LibertyTM SBS Self-Adhering Base/Ply Sheet,StormGuard®Film-Surfaced Leak Barrier and WeatherWatch®Mineral-Surfaced Leak Barrier GAF Extended Dry-In Membrane Mechanically attached 180 Adhesive-set tile'roof system 180 Ruberoid®Mop Granule and Ruberoid®Mop Granule FR I' Mechanically attached UNLIMITED i .5.10 Tile Slippage Limitations:When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4 TILE SLIPPAGE ltIUI1TAT1OPIS FOR D)RECT DECK TILE NSTALLATIONS '. , Underlayment „ f, Tfe Profile ,, < „` ;Staging Melod, i Maximum5tagmg;5lope , Flat Max.10-tile stack 4:12 Ruberoid®Mop Granule Flat Max.6-tile stack(4 over 2) 5:12 Lugged Max.10-tile stack 5:12 Flat or Lugged Max.6-tile stack(4 over 2) 5:12 Ruberoid®Mop Granule FR Lugged Max.10-tile stack i 4:12 i I INSTALLATION:6. 6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. I 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application and prime the substrate(if applicable). 6 3' Deck Armor""Premium Breathable RoafDeck Protection or Tiger!Paw 'Premium Rob.,Deck Protection_* 6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception) or 1507.1.1.1(3,Exception)or FBC Residential R9O5.1.1.1(2,Exception)or R9O5.1.1.1(3,Exception)for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6 4 FeltBuster®Synthetic Roofing Felt: t ` 6.4.1 Shall be installed in compliance with requirements forasynthetic underlayment in FBC 1507.1.1.1(2,Exception), 1507.1.1.1(3,Exception)or 1507.1.1.1(5)or FBC Residential R9O5.1.1.1(2,Exception),R9O5.1.1.1(3,Exception) or R9O5.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6 5' StormSafe'"'Anchor Sheet_: ' 6.5.1 StormSafe'""Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems. 6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception) or 1507.1.1.1(3,Exception)or FBC Residential R9O5.1.1.1(2,Exception)or R9O5.1.1.1(3,Exception)for the type of prepared roof covering to-be installed,and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. I NEMO ETC,LLC Evaluation Report 01506.04.08-R23 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R23. GAF Roof Underlayments Revision 23:12/14/2021 Page 7 of 8 WNEMO[etc. 6.5.3 One the same day, install LibertyTM' SBS Self-Adhering Base/Ply; StormGuard® Film-Surfaced Leak Barrier or WeatherWatch®Mineral-Surfaced Leak Barrier over the StormSafeym Anchor Sheet. G 6 6 5hfngle Mate°Robb Deck Protection - � _ 3 6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM D226,Type 11)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.111 for the type,of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. j 6 7 "Verrsa5hield�Flretesrstant Roof 6.7.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM D6757)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1:1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions._ FBC requirements take precedence over the manufacturer's installation instructions. N.6 8 yGAFExtenddd Dry tnMernbra�ne,tarty'"SBSS�If1dteringase/Plyyheet;StarmGuard�Fllm Surfaced Leak Banner orWeathel�tatcFr®Mineral Surfaced�Leak Barrier _ *s, .Q _ >.. ., IXI 6.8.1 Shall be installed in with requirements for an approved self-adhering underlayment(ASTM D1970)in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or 11905.1.1 j3 for the type of prepared roof covering to be installed',and the manufacturer's installation instructions. 6.8.2 Back-nailing is required. Back-nailing shall consist of Approved cap nails;spaced 18-inch o.c.,encapsulated within min.4-inch side laps. 6.8.3 When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt,the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.8.4 GAF Extended Dry.-In Membrane,Liberty'"'SBS Self-Adhering Base/Ply Sheet,StormGuard®Film-Surfaced Leak 'Barrier or WeatherWatch® Mineral-Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6.9.1 Shall be installed in compliance with requirements as an alternate to the"Hot Asphalt�Applied Cap Sheet"in the "Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,and the manufacturer's installation instructions. 6.9.2 Refer to Section 5.8 herein for attachment limitations. 6.9.3- Refer to Table 4 for tile staging limitations. BUILDING7. • As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING �i PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A iC.Rule 61G20,13 CIA requirements. Refer to Section 4 herein for products and production locations having met codified materiall standards. QUALITY9. UL,LLC.—QUA9625;(613)371-2765;Jacob.Stewart@ul.com - -END OF EVALUATION REPORT- i NEMO ETC,LLC Evaluation Report 01506.04.08-R23 Certificate of Authorization#32455 7-EDITION(2020)FBC NON=HVHZ EVALUATION FL10626-R23 GAF Roof Underlayments Revision 23:12/14/2021 Page 8 of 8 II