Loading...
HomeMy WebLinkAboutFBC Energy Conservation 03-21-18Planning & Development Services; Building & Code Regulation Division 2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 FBC ENERGY CONSERVATION CODE R402.4.1.2 House Infiltration Test (Blower Door) Certification Prescriptive and Performance Method Date: 03IZ112018 Permit #: no 6 - OZZ7 Contractor: p g Hor nn Job Address: Construction: (✓) New Construction — Complete ( ) Existing —After Addition House Infiltration Test. Results SLC Climate Zone 2 r CFM (50) = I1 y GI Test Date: 03 ki [go I Volume = 1 6Lt57 ACH (50) = CFM (50) x 60 / Volume = y 19 Me4lianical Ventilation required less than 3 ACH Passing results must be & ACH (50) or less (�/) Pass ( ) Fail FBC, Energy R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: kve-fiec Address: 9570 he4ert4/ �nuune glud *Hto Toc6onyi ke I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: nib &Oc�ke8o, Ili I License/Certification #: =YX4VS APPROVED Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 772-462-2165 Fax 772462-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method Date: Permit #: _ Contractor. M VV Construction: k'roost Construction Test OAR I iill Permtwng Qepartment St. Wcle County L`ot#: u Address: S. ❑ Rough -in Test Test Conditions: Date: V Floor Area (ft2): Time: Primary Location of Supply Ductwork �L Indoor Temperature (F): I Primary Location of Return Ductwork �. Outdoor Temperature (F): �o Total Leakage Test (Outside) � Duct Leakage: ❑ Default ❑ Prop. Leak Free Proposed On = Test Pressure: (Pa) Baseline Duct Pressure optional) (Pa) Duct Press. (Pa) Flow Ring Fan Press Flow (cfm) Results: ass ❑ Fail Installed Pa Total Leakage (cfm): Total Leakage per 100 sgit: s CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sgft. Testing Company �¢ Company Name: Q.�`(4��CL Address: `�57c) I hereby certify tha�tthheabo DuctSNfrg Leakage results demonstrate compliance with 5"h Edition FBC Energy Conservation requirements in accordance with Section R403.2.2. Signature: Printed Name: r�� �� �) License/Certificate M / ~ Planning & Development Services; Building & Code Regulation Division 2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 RZ-GD FBC ENERGY CONSERVATION CODE R402.4.1.2 Off' i 6IQ" House Infiltration Test (Blower Door) Certification pNowe�a� Prescriptive and Performance Method Date: I b Permit #: 7 d� - 6 as Contractor: Job Address: 3(7- r Construction: ( ) New Construction — Complete ( ) Existing —After Addition House Infiltration Test Results SLC Climate Zone 2 / CFM (50) = 5'�s k Test Date: 0314 k� Volume = o ACH (50) = CFM (50) x 60 / Volume = - b b Mechanical Ventilation required less than 3 ACH Passing results must be & ACH (50) or less Pass ( ") Fail FBC, Energy +', R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: � �—i-2� Address. 1 �7o ��'�i , �-�iC�kc�s (�I. I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordpee wit Sec-tid—n R4 .4.1.2 Climate Zone 2. Signature: Printed Name: License/Certification #: / Dous� DISAPPROVED