HomeMy WebLinkAboutProduct ApprovalFlorida Building Code Online
Page 1 of 2
RECER1 ._D AN 0.9:2017 :.: "'
r1" Bug
r &r Ulat i a
eas Hdrirc J_:Lop In I user ReyKiratlon ± Not 7opks .Submit Surchalpe :. StaLS fi Facts. PuEltotlons I FBC Stiff r 'acts Site Map ! Links '
OFbdda
Product Approval =
USER: Public Use
r.
:- .. , dP➢llGdtlDO.Llit > Application Detail . .
FL #
FL17147-RI
Application Type' Revision
Code Version 2014
Application Status Approved
Comments
Archived..
Product Manufacturer Huber. Engineered Woods LLC.
Address/Phone/.Emall. 10925 David Taylor Drive
Suite:300
Charlotte, NC 28262
(704) 548-5442 ' '
kurt.koch@hubei:com
Authorized Signature Kurt Koch
•kurt.kocq@huber.I om
Techrilcal' Representative Ken W. Htx
Address/Phone/Email 1446.Hwy 334
Commerce, GA 30530
(706)336-3041
ken.hix@huber.com "
Quality Assurance Representative Walker Campbell
Address/Phone/Email 1446 Hwy 334
Commerce, GA 30530
(704) 562-1053;
walker.ca�mppell@hu6er.com
Category Struchiral Components,
Subcategory
Products Introduced as a Resuit:of New Technology
r Compliance Method Evaluation Report from a Product Evaluation Entity.
Evaluation Entity, ICCEvaluation Service, LLC
Quality Assurance Entity ICCEvaluation Service
Quality Assurance Contract Expiration Date 10/01/2017 .
Vaildafed: By ICC Evaluation Service, LLC.
Certificate -of Independence FL17147 R1 COI'Lertificate of ind a ' + nra rrir gvaluation.odr
Referenced Standard and Year (of Standard)
Ye;9t.
ICC-Evaluation Service'AC310 2015;
Equlvalence of Product Standards
Certified By
Approved Evaluation Entity
FL17147 RI Eauiv AC310 odf
Section41rdln the Code
File. copy
https://www:floridabuildin :or r/ r a dtl.as x?� aram=wGEVX wtD *Co3Ea iI1Bd... 4/12/2017
g �P P PP— P P Q ... q P
' Florida Building Code Online
Page 2 of 2
Product Approval Method
'Meibbd 1 Option C
Date Submitted
06%31/2015
Date. Validated
09/16/2615
Date Pending FBC Approval
Date Approved _
09%20/2015
h Summa' of Products
pL # Model, Number or Name Deseription
17147.1 ZIP System (R) Wall.Sheathing ZIP System (R) Wall Sheathing
Limits of use
Approved.for use in HVHtt'No
Installation instructions ' .
Approv®d for use outside HVHZQ YPS
Impact:Resistae: No
EL17147 RS II ZIP she�thlna Inctali R anal �m� SF
V,eriFled By; ICC Evaluation Service, LLC
Design Pressure: N/A.
Created b'y Independent Fhlyd'Pa rtY,
Other; limited to structural aspects of panel
Sveatedon Re
FL17147 111' A ' RqR1d7A —If
•
Beck Ne,R
contact ij :::'2601 Blair
The State of Florida IS an AA7EEo employer. Ccovrlehr
.
r3lene head 'rti1Ph- - ^ Dhenrr• as0.4s7-Se24
2007-�01+ tat of Flo 'ic :: ffiYdcv_ C�temr t
.. :: 6[ass161ii- HS[an"^"^I :: Amend cr�I.nvn�
Under Florida law, email addresses are pubrk awards. B you do not want your a -mall addressreleased in rvspcnsg m apublic-records request, do not send
electronic mail to this anety. Instead, contact the office by phone or by traditional mall. If you have any questions; please Contact a50.497,1395: -Pursuant
Section 455.275(1); Florida Statutes, effective October 1, 2012,
to
licensees licensed under Chapter 455, F.S. must provide the Department with an email address B
they have one. The smalls Provided may be used far oN1Ual communication with the licensee. However email Sddressrs are public record. If you do not wish to
re Public
supply a personal address. Please provide the Department with an email address which tah'be card
.
made available to the pu6tic. . .
detem ne�qyou are a Inotlwis under
Chapter 455, F.S., please dick hM.
Product Approval Accepts! .
'Credit Card
Safe
6.
h4s://www.fl'oridabuild-ing.or—&tj 4%12✓2017
6
w
ZIP:System®Roof & Wall Sheathing
INSTALLATION MANUAL
-r system
Contents
FASTER. TIGHTER. ENERGY EFFICIENT.
02 ZIP System® Sheathing Installation: On Roofs
: 08 ZIP Systems Roof & Wall Sheathing Window
03. ZIP System- Tape: Installation -
Installation Flanged WtndowS &: Brick Mould Windows
:Roof Panel. Seams
'04.i
-
•09. ZIP�Systeme Roof ,& Wall Sheathing'=:Window
ry
ZIP System Tape. Installation =
Installation Brick Mould Windows (continued
Roof Panel Seams. continued
10 Z1P System® Roof & Wall. Sheathing -
05 Roof Covering Installation .Instructions
Penetration, Openings
06 ZIP System° Roof &,Wall Sheathing installation
11 ZIP System® Roof & Wall Sheathing
Installation Details
07 ZIP System Tape Installation,- Panel Seams
12: ZIP System® Roof. & Wall Sheathing
installation Details (continued)
ATTENTION: This installation guide is:interided -to provide general
information ior_the designer and end user. The following
:ZIP. System Roof & Wall sheathing can be used with a range of exterior
guidelines.:.
will help you safely end properly install the ZIP System°Roof & Wall
wail sheathing. We urge you,: and anyone installing.
claddings and roof coverings.:Approved wall oovoings include brick,
vinyl, stone, wood fiber cement, wood and. cedar shakos... raditional hard
this product, to
read.theae guidelines in order to minimize any risk of safety hazards
and to prevent voiding any applicable
coat stucco and specifled drainable EIFS_ gpplications, however' it: is
not recommended for -use .with adhesively attaced EIFS. Approved roof
warranties. This manual is ,
a general installation guide and does not: cover every installation
condition. Proper inatallation shall be deemed 'the
coverings Include asphalt -fiberglass shingles, metal -files .and panels, day and
concrete tiles, slate and slate type shingles and wood shakes'and shingles.
to mean most
restrictive requirement apeeified oy Huber Engineered Woods ((iEW),
Follow all claddirig'and roof covering manufacturers installation instructions.
local building code, engineer or architect. of record or other authority
having jurisdiction.. lfou:are fully and solely responsible for all safety
requirements'and;coda
ZIP System Roof &Wall sheathing 'can be used on buildings of Type
ill. (Roof Applications ONLY) and Type V
compliance. For additional information contact
Huber Engineered Woods LLC.
construction anti construction
permitted under the IRC.
ZIP System° Roof a Wall Sheathing Safety Guidelines
- Follow all OSHA regulations and any other safety guidelines and safely
ZIP Systems Roof & Wall Sheathing lneludes;
- ZIP System sheathing panels with built-in moisture barrier with preprinted
fastening
.
practices during installation and construction.
and tape guides
ZIP System tape
- Use approvedsafetybettsand/or hamessesorotherfallprotodonequipmerd
_
- !nstalli0 System panels and tape only in dry conditions and on dry. surfaces.
Do
Storage and Handling
not install, In.rain, snow, frost orottier slippery conditions.
Wear rubber soled or other high -traction footwear white installing ZiP System
-Set panef.stack on three supports (stickers) to keep off the ground.''
- Outdoors, cover panels to with waterproof Protective
sheathing in a roof application. Do not wear'foofweai with worn soles or heels.
- Ensure .the roofing surface is free from oil, chemicals,
material.
'Anchor covers on top of the stack, but keep away from sides and bottom
to assure good eirculatlon.
sawdust, oirti ;tools,
electric cords, air hoses, cloVng arid. anything else that might: create a
tripplh9 hazard.
air
- In high molsture;environments, cut. banding on the panel stack to prevent
- Install temporarytoe boards along the ZIP System sheathing roof surface:
edge damage.
ZIP System• Roof &Wall: Sheathing Notes and Limitations
What. Is ZIP System° Roof & WeI1.Sheathingl
= Do not use on roofs with'slopes less than'2/12;
ZIp:System Roof &Wall sheathing.is code recognized as a wood structural
panel, -roofing...
underlayment (ICC-ES ESR-1973);
- Do not use abutted against general stone or masonry without providing a
minimum of a 1/2' gap.
water -resistive barrier
and air barrier (ICC-ES ESR-1474), ZIP System Roof &Wall sheathing'
has a •built-!n moisture bamer•
Do not install ZIP System tape in temperatures less Than 20°: F
ZIP System products are not recommended form'
that lets ycu say good-bye. to building paper
or hous.'ewrap on the walls and:felt paper on the roof.• Simply, install the
housing
applications that are built under a' federal building code administered by
the seams, and you have a structural wall sheathing; water-
p resistive
resistive barrier and, air barrier or a structural root sheathing and roofing
the U.S.:Department of Housing and Urban.Devetopment (HUD).
Do.not use panel edge dips (H-Clips) vMZIF System Roof & Wall sheathing
undedayment.all from one product.
without expressed written approval from Huber Engineered. Vlloods."
Do. not use ZIP System. tape to permanently seat around circular roof
Projections' (plumbing vents, pipes, curved walls, etc.)
r
Contents (continued
Wall Coverings
- ZIP System Roof & Wall. sheathing :should be covered with the.finlshed
roof covering or exterior cladding within 180 days of installation.
Finished roof and extertor'cladding products, should be installed, per
the manutacturer!s installation instructions.
- Per the recom►iterldation of the Western Red.Cedec Lumber Asso_ ciatlan
and the-U.S. Forest Products Laboratory, wood siding should: be primed
before installation.
When orgtnal roofing or claddings are removed and replaced on existing ZIP
System sheathing; the roof or wall should tie' covered with an additional:
roofing.undedayment or water resistivebarder prior to installation of the
.new finished roofing or cladding.,
Note: In cladding systems requiring multi
Pie of watar-resistive harriers,
like traditional hard -coat stucco, Zip System shetithirig Is intended only to
replace the firstlayer.
Wet Blown Cellulose Insulation
In addition' i to following manufacturer installation instructions, we'recom_rrend
a maximum moisture content of the celtulpse of less than 25% measured at
the inside stMace of the ZIP System panel before closing the will cavity.
Secondary.Coatings
Do not apply secondary coatings or treatments to ZIP System Roof & Wall
sheathing :paneis:with the exception of the following:
HEW approved fire resistant. coatings. Fire resistant coatings must be
tested and approved liy HEW.for use with ZIP System panels.
Field applied water soluble borate insecticide or fungicide treatments
applied,to the non overlay side .of the panel. See technical tip, Termite
Treatmentsan ZIP System Roof& Wall Sheathing," on iipsystem.'corn for
more information.
Permeable laminated radiant barrier foil or paint.. For a radiant bonier foil or
coating to be considered permeable, it must have an applied permearice of
five palms or greater as tested by.lhe:AS fM E 95 wet cup standard. Fora
radiant foil, the pe.rmeance evaluation would include any adhesive and/or
backer used to laminate a: foil; For a radiant pairit/coating, the permeance
evaluation should be condutited at the applied thickness of the paint/coating.
ZIP System Roof and will sheathing replaces only the first layerin.muto+undedayment systems.
Edge support is not required by code with 1/2 (32/i6 span rated) and 61B (4MO span rated) performance'dategury sheathing it the framing does nal exeed 24' e.o.
and the total load does not exead 93 psi fat M and t56 psi for US performance categories. Thisis based an Mao deflection vitena for total load.
ZIP.Syster0 Roof & Wall Sheathing Installation Manual
02
ZIPS... tem° Sheathing.litstallation on Roofs
Overview: ZIP System Root &Wall sheathing is Composed of ZIP System, panels and ZIP System seams sealing tape. ZIP System' Roof 8-Wall Sheathing
panels should be fully installed before, the seem sealing tape is applied; In general, the ZIP System roof sheattiing'panels should be Installed from the lowest'point
on the roof to the highest It is at the discretion of the instafier whether to apply tape from the top down ar from the bottom up.: However, workio from the: st p9jst
sections of- the roof and worldrtg clown will minimize foottraffid on the tape. The following Installation steps are.presented as guidellnes.and.a general outline of
the installation process. These are manufacturer.Instaliation recommendations -please visit zipsystem.com tor.a library of flashing and installation details. You are
fully and solely responsible for all safety requirements Good construction and:safety, practices should be followed at all times.
Step 1:
Ensure that the panel surface is dryand Gean of any nails; sawdust, or .
other debris.or protrusions prior to Installing or walking on the panels.
• After ensuring :compliance with all"OSHA and. local code safety .
guidelines, Install ZIP *09m- sheathing
g panels w8h the moisture
barrier surface facing:outside.:7he long edge (81) should be oriented
perpendicular to the framing members, -and panels should'be' installed
with the 4' edge: seams staggered a minimum of 24'.
.1/8' spacing between square edges of a0 adladent panels is recommended,
in accordance with industry standards for wood sheathing: (Tongue &
Groove panels are designed.to.self-space and do not -require manual e' Panet Edges 4' Panel Edges
spacing_ on the 8' edges.) its, 1fir
x t +
The unique edge pro@e is Maintain 1/8• space
designed to accommodate where 4' edges:meei.
Incremental panel Unique edge profile is on
expansion'and does not W edges only.
require manual gapping
along the 9 edges;
te
Ensure that ZIP System panels span at least three framing members and
a framing -member supports the entire.4' edge: of the panels.
w - Fasten the System Roof & Wall' sheathing panel to the framing.:
members With code approved. fasteners spaced at the appropriate
edge"and intermediate spacing..ltIs the responsibility of the general
contractor to verify proper fastener type and spacing priarto installation.
- Apply the fasteners•3/8' from the panel ends and, comers.
An Ideal installation would be where fastener heads are flush with the '
panel surface. However, due to variations in materials and limitations
on equipment, this may be difflcult to achieve in some situations. It
Is not required to tape over overdriven fasteners' unless the fastener
head creates:a :hole through the entire panel.thickness Please see.
the.technlcaf tip; °Overdriven Fasteners in ZIP System Roof and Wall
Sheathing," for more information.
Install temporary toe boards as necessary'When applying the ZIP System
sheathing. panels up the slope of the roof planes.: all
03
ZIP Sy;3teln"' Tape. Installation - Roof Panel Seams
Apply ZIP System tape utter all ZIP System Roof & Wall sheathing panels are fully fastened to roof -framing mem6 rs. Only ZIP System tape should be used to
seal the seams of ZIP' System panels. Ensure that the panel surfaces are dryand free of any nails; sawdust�arid other debris, or protrusions, Avoid stepping. .
anaape in high temperature environments. ZIP System tape is a: contact tape that requires pressure for an adequate sash .
v. Step 1.
apply -
ZIP Systemtape.to every vertical and horizontal panel seam. It is
at the'discretion of the installer whether to apply to a from the top down
PP Y P
or.from the bottom up.' However., working.from the highest sections of
I
roof and working down will minimize foot traffic on the tape.
- Ensure that the tape'Is centered over the.
within +/-1/2° to provide -
adequate coverage and to ensure that wrinkles in the tape are minimized.
Ensure that tape lengths are continuous across the 8' horizonlat edge
ci the panels. If splices are unavoidable, creat6 an' overlapping splice
of at least 3':'Apply moderate pressure onto the surface of the tape -to
ensure a secure bond between the panel and the tape.
Use ZIP System tape gun, or tape roller to apply pressure to the tape
and smooth out any.wrinkles:
Take special care to remove any voids.andlor (rapped air at splice
areas and T-joints.
Ste 2
P
For valley areas of framing, we recommend you use 6°.wide ZIP System
tape: This tape is wider than panel seam tape and Is designed to give you
optimal protection In valley areas
Starting from the bottom and working your way up; apply one continuous
Piece of.6' tape so that the center of the tape!' over the valley seam.
Use the tape gun or tape roller to apply pressure to the tape to ensure
Proper contact with the: panel and to eliminate any wrinkles that might
have occurred in the tape. Take special care to seat tape completely
Into the valley: : .
Note: .
It is important to pay.extra •attention to valley taping as:water is
directed toward the valleys during rain events. .
- Self -adhering ice and water barriers. maybe required by code. ZIP
System tape is not considered a replacement -for self -adhering ice. . .
and water barriers. Therefore, when self -adhering to. and water
barriers are required,: they should be installed in addition to ZIP
ystem tape: . .
ZIP System* Roof &Walt Sheathing Installation Manual
04
ZIP System'" Tape Installation - Aoof Panel Seams (continued)
[Ste.p3'
if6.ZIPS System
yst tape is riot available, use two continuous pieoeti of 3.75-
ZIP System panel seam tape over. the entire length of the valleyseam,
ovedapping.the"places on the Valley seam by at least 1'.'
tariingthe bottom, Install the first:piece of tape overlapping the...
valley seam' by at least. f ".
First piece
Use the tape gun or tape roller to apply pressure to.the.tape to'' nsure t
proper contact with the panel and to eliminate any wrinkles that might
have occurred In the tape.
Apply the second piece of tape, overlapping the first piece In the valley'
"seam: by 1'.
Repeat use of the tape.guri:or roilerto make sure the:tape is adequately
adhered and tightly pressed into the valley seam.
Note: : second piece
d tape
It is important to pay extra attention to valley taping as water is
directed toward the valleys during rain events.
Self -adhering ice and water barriers may -be required by code. ZIP
System tape is not considered a replacement for self-adhering"ice
and water barriers. Therefore, when self -adhering ice and water
... barriers are required, they should be installed in additinrrto ZIP ravedap
System tape.
ep.4..
To, provide temporary, weather' .protection to roof/Wall' intersections
of dormers or other wood -sheathed projection;, apply 2" of the tape
Width up -the; vertical projection from Where it:intersects with the roof.
The remaihing tape width can be adhered to"the.Zip System roof
-sheathing panels.
Use the tape.gun or tape roller to apply pressure to the tape and smooth "
out any wrinkles:
Step 5.
Install ZIP System tape over hips and Odges by centering the tape over
the peak seam'. Apply tape in sufficient length to'completely extend the
length of the hip or ridge.
Starting from.the lowest point of the hip and working up, press tape Into
Place keeping tape centered over the hip. Apply moderate pressure
onto the surface of,the tape to ensure a secure bond between the panel
and the tape.
Cut ridge tape as required" for ventilation prior to Installing ridge vent.
Step 6.
Tape:over toe board nail holes once the toe boards are rembved,.working
from the highest toe boards to the lowest.,
Roof. Covering Installation Instructions
ZIP System Fioo}.& Wall sheathing is a code recognized sheathing and underayment and is approved for:use.wlth the following roof coverings:
Asphalt -fiberglass Shingles =
.Metal Roofs (shingles and panels)
- Clay Tile
Concrete Tile
Slate and Slate type Shingles
- Wood Shingles
- Wood Shakes
Wheninstalling roof coverings, follow applicable codes and Manufacturer's.suggested Instructions. Some root coverings require aslip-sheet.In addition to
conventional underiayment. Where slip -sheets are:required, they should be Installed aver ZIP System sheathing panels.
Note:. Visit zipsystem:corn for,updates. and installation details.
Asphalt -fiberglass Shingles
Apply asphalt -fiber es directly to ZIP System sheathing: For roofs with a slope of.2/12 or greater but less than 4/12, additional undedayment:may be required.
Install asphalffibeglass shingles according to applicable codes and manufacturer's installation Instructions.
Metal Roof Coverings
Metal roof coverings may be applied to
codes -are foil owedZIP System sheathing provided that the roof covering manufacturer's Installation Instructions and applicable
...
Fasteners used to, secure the ZIP System,Roof S Wall sheathing panels to.supporting framing must be compatible with the specific metal roof covering
used. Galvanized fasteners -shall be used with galvanized roof_coverings; aluminum -zinc -coated fasteners shall be used with aluminum-ino coated roof
coverings and 300 series
es stainless steel fasteners shall be used with copper roofs. Stainless steel fasteners are acceptable with all metal roof types.
In addition; metalroof flashing shall also be made of a material compatible with the specific metal roof covering used. Apply metal shingles'on roots with
slopes of 3/12' orgreater:
Clay and Concrete Tile Roof Coverings
ZIP System Roof & Wall sheathing is Intended to replace the first layer in a two -layer or.muftklayer underiayment system. When installing clay or
concrete tile roof coverings, follow the installation recommendations of FRSA/TRI.07320. Install fil
Installation Instructions. e roofs according to applicable codes and manufacturer s
Slate and Slate -type Shingles
Apply slate and slate -type shingles on roofs with slopes of 4/12 or greater. Install slate and slate -type shingles according to;applicabla codes and manufacturees
Installation instructions.
Wood Shingles
ZIP System. Roof &Wall sheathing is Intended to replace the first layer of underiayment required by the 18C and/or the IRC. Additional layers of underlayment
may be required by code depending on the local climate. Apply wood shingles on roofs with slopes of 3/12 or greater.. Install wood shingles according:to
applicable codes and manufacturees:tnstallation instructions.
Wood Shakes
ZIP System Roof $Wall sheathing is intended to.replace the first layer of underiayment required by the IBC and/orthe.IRC. Additional layers of underiayment
may be required by code depending on the local climate. ZIP System roof sheathing is not.to be construed as a replacement for Intedayment. Apply.wood
shakes: on roofs with slopes of 4/12 or greaser. Install wood shakes according to applicable codes and manufacturer's installaton instructions.
ZIP System' Roof &Wall Sheathing Installation Manual
06
ZIP: $ystem® Sheathing ,Installation tyn. Walls
Overv(ew: ZIP.System Root & Wall sheathing is composed of ZIP System pariels.and ZIP System seaniseating tape. ZIP System° F... p Wall Sheathing
Panels should be fully'installed before the seam sealing tape. is applied. The following
installation steps are presented as a .general outline of the installation
process: These are manufacturer fristallation recommendations —:please visit zipsystem.com-for a library of flashing and insfaliatian details. You
solely responsible for all safety requirements.
Good construction and safety
are fully and
practices should.be followed at all Umes.
ZIP ' System Roof & Wall !sheathin g panels positioned
With water -resistive barrier facing outside: The. panels may
alled with the long .side of the panel oriented either
tal) or'verticalty to the framing members. Walls that'are`
lall
"
d to resist lateral shear forces :and sheathed with wood:
l panels typically require solid framing or blocking behind
l edges. If oriented hodzoritally, block horizontal Joints if
Wallis designed for bMciog or, as a shear wall:
VT spacing between square edges of -all adjacent panels is:
recommended -in -accordance with Industry'standards for.wood
_sheathing installation,
8' and O
B' Panel Edges Penet Edges 4' Panel Edgee
II II
.
II
The unique edge profile is Maintain 1/8, space where Maintain 1/8- space
designed to accommodate B' panel edges meet 4' where 4' edges meet,
incremental panel. panel edges. Unique edge Unique edge profile is• on
expansion and does not profile does not provide 8' edges only.,
require manual gapping the full 1.18, recommended
along the 8' edges.• 'space id this situation.,
Step 2. Fasten the' nets to the framing members with code approved
fasteners. Space fasteners s- o.o: along supported edges and 12°
o.c. at intermediate' supports,; unless otherwise specified by'local
- code or the designer of redord,' It is the responsibility of the' general
contractor to verify -proper fastener type and spacing prior.to
installation: Apply the fasteners 3/8' •Jrom the ends and corners..
An -ideal installation would be where fastener heads are flush with
the panel surface. However, ,due to variations in materials and
limitations on equipment, this may be difficult to -achieve In -some
situations: It is not required fo tape over overdriven fasteners
unless.the fastener head creates a hole through the entire panel
thickness. Please see the technical tip 'overdriven -Fasteners in
Zip System Roof and. W611 Sheathing," on ilpsystem.com for
more information..
M.
ZIP $ysteln'" Tape Instillation - Walt Panel. Seams
Apply ZIP System tape utter all ZIP System Roof & Wall sheathing panels are full fastened to wail -framing members, Only ZIP System tape should be used
to seal the seams of:ZIP System panels. Ensure that the penal. surface is dry a d free. of. sawdust and dirt prior to. taping. System
tape that requires pressure for. an adequate seal,
ZIP. tapeIs a contact
;. Step1. Tape:all;seams using ZIP System tape; Ensure that the tape:.
%s centered over .the. seam within 4- i/2" to provide adequate
:coverage and that wrinkles in tape are minimal.
Use the ZIP. System tape gun or roller to apply pressure to the laps
ap
and smooth• out any wrinkles. .
Step 2 Wherever tape splices occur at a horizontal or vertical seam, create:
an oJedapping splice Of -at .least 3'.
At T-joints, the tape pieces should overlap by at leasf V.-Apply
moderate pressure onto the surface of the tape to ensure a secure
bond between the panel and the :tape;
Use the ZIP System tape gun or roller to apply pressure to the tape
And smooth out any wrinkles. .
Take special care to remove any voids and/or trapped air at splice::
areas and T-Joints.. .
91ep:3. Tape Inside and outside comer seams.
y1 �
Inside comer seam
.. :.. .
. .
Ouktde comerseam
. .. _
Note: Tape.over any mews of the panel or tape that are damaged during, construction.
ZIP system® Roof $'Wall Sheathing Installation Manual
08
ZIP System - Window Installation olscLAlmtR:TheroNowlnBclePsrepresentageneralwerviawfor the proparinslaRaftfo.fwlntlowtlash ,Pieesedetertdoorisufl
the IrgteValion Instructions o1 your w ndow manufachirer as well as code requlremeida in your iurlsdkiion a full Instftll wh'details:
Flanged Windows "
Ftape may be used as pan flashing if
n accordance With flanged -window
details posted onzipsystem.com.
sive-based(lashingtapes (must meeteptance; Criteria for Flashing Materials
may be used as pan flashing If installed i
per ASTM 2112--07. Apply the flashing to cover
the bottom of the opening, overhanging onto the
sheathing by at least 2" and extending a minimum
of 6' up each, jamb.
3. Apply sealant around inside lace of mounting
flange. Sealant must be gapped. at the sill
to permit drainage. Install and level window per
manufacturer's installation instructions. Verify.
sealant compatibility with window manufacturer.
When using ZIP- System. tape as pan flashing,
butyl, lo0% silicone or polyurethane sealants
are acceptable. Do not use:latex'or other water -
based sealants.
4. Cut two pieees.6. ZIP System tape or another
adhesive -backed flashing tape (must meet ICC-
ES Acceptance Criteria for Flashing Materials
(AC148)) and apply -to each of the window jamb
flanges, ensuring .the jamb flashings overlap the
sill flashing.
Once.the tape is in place, use the tape gun or roller
to seat the flashing to the sheathing.
S. Cut a fength. of ZIP System .tape or another
adhesive -backed flashing tape (must meet 1CC-
ES Acceptance Criteria. for Flashing Materials
(AC148)) and apply,to the header, ensuring that
the flashing overlaps the jamb (lashings.'
Once the tape is in place, use the tape gun or roller
-to seal the flashing to the, sheathing.
'�0 NOT Wpa bottom Qarige. I
6. From the Intefior,_apply low-pressure polyurethane:.
foam (for windows] between the rough opening
Ind the window frame. (Caulk sealant compatible
with fhe. siiLtlashing may be used. at the; sill if the
opening between the sill flashing and window
is too narrow to allow the use of low-pressure
{
polyurethane foam.)
a !
When using ZIP System tape, butyl, t00%
;s
.-silicone or polyurethane:sealants are acceptable.
Do not use latex sealants with ZIP System tape. If
using another flasfing tape, follow the. flashing
manufacturer's recommendation in selecting a
sealant -compatible with that flashing:
Brick Mould Windows
1. Fasten the ZIP System sheathing
to the wood frame and install
ZIP System tape to all wall panel
seams, -as detailed in sections
02 and 03> .
� 1
2 If recommended by. the window
manufacturer, cut a strip of wood
to function:as a back dam at the,
sill. The wood strip should have
a length equal to the width of the
rough opening and a height and
Width of at feast112". Position the
block, at. the inside edge of the
Window frame.
!"
y t i %
09
ZIP System — w%ift(IQ1A/ Installation asCuuMER:Thefokowingslepsrepresentageneral'odervew(orthe properlristagatldnolwintlowflashing.Please defer to/conauk
the InategaUdn' nstructions of your w ndow manufactuMe as well as code raquiren�nrs in your jurisdiction for full installation details.
Brick Mould IMndows (continued)
3. ZIP System tape may tie used as:pan flashing if
installed in accordance. with brick mould window
Installation details posted on- zipsystem.com.
Other adhesive -based flashing tapes.(must meei-
ICC-ES AcceptanceCriteria for Flashing Materials
(A6148)) may be used as pan flashing if installed
per ASTM 2112-07. Apply.the if to cover
the bottom of the opening, overhanging onto the
sheathing by:at least 2' and extending a minimum
of 6' up each Jamb.
4. For vertical Janibs, cut ZIP System tape or ariother
adhesive -backed flashing tape (must meet ICC.
ES Acceptance Criteria for Flashing, Materials
(AC148)) -and apply to each of the window Jambs.
Ensure that they cover the entire inside of the rough n
opening as well as overlap onto the' sheathing by
at: least 2". Flashing shall also :extend above the \ .
rough opening,.such that it will project 1' beyond '
the exterior trim of the window.
Once the tape is in place, use the tape gun or roller
to:seal the flashing to the sheathing.
rd
ly sealant to Jambs and header allowing for
nage at the, sill in accordance with window
ufacturer's. installation instructions. When
g ZIP'System tape, use a butyl, polyurethane
00"/o silicone sealant Do not use latex or
other water -based sealants with ZIP System
tape. When using another flashing tape, follow the
flashing manufac-turer's recommendations in "
selecting a sealant compatible with that flashing:
6.' Iristall and level window 'per Mariufacturer's
.installation instructians:_
V
7. Cut a piece of rigid head flashing so that when
installed, (His flush with the edges of the exterior
moulding of the window. Apply a bead of sealant
to the back and bottom surface of the rigid
head flashing, -Use sealant recommended. by. the
Flashing manufacturer.
8: Secure the rigid head flashing to ZIP System
wall sheathing.
9. Cut a length of ZIP System tape, or: another
adhesive -backed flashing tape (must meet ICC-ES
Acceptance Criteda for Flashing Materials (AC148))
and apply to the rigid head flashing, ensuring
I hat the adhesive -backed flashing overlaps the
Jamb (lashings.
Once the tape fs in.place, use the tape gun or roller
to seal the flashing to the sheathing.
10. From the interior, apply low-pressure polyurethane. -
foam (for windows) between the rough opening and "
the window frame. (Caulk sealant compatible with
the sill:flashing may be used at the st fif the opening
between the an flashing and window is too narrow
to allow the use of low-pressure polyurethane foam.)
When using'ZIP System tape, butyl,1 o0% silicone l
or .polyurethane sealants are acceptable: Do not
use latex or other 'water -based • sealants with ZIP
System tape. If using another flashing tape, follow
the flashing manufacturer's 'recommendation In
selecting a sealant compatible with that flashing.
ZIP System® Roof & Wall Sheathing in Manual
ZIP System -Penetration Openings 01� � fep � RONing steps represagt a ge iersl overview for the proper instagadon of penetrat on f✓eshfng, please deter. Io/consuN
Gu your iudsd ctian fadu details.
WOO
wiLrAsS,sEAiety
LPS Al DWALL SHEA719F1G
G GR LT. GA. METAL STt1D5
11e4NCH GAP RECOMMEND OAT
PANEL EDGES UNLESS . .
OTHERMSE PROVIDED BY .
MACHINED PROFILED EDGES' h�
T
LNSTALLM SYSTEMOTAPEOR S' ADHESwE SACKED FLASHING (MUST
MEETACty)IN.SEQUENCE FROM
SOTTOM, SIDES, THEN TOP TO
ENSURE SHINGLE LAP OF AONESNE
BACKED FLASHING.a
n\
ZIP SYSTEMOTAPE INST _ ( ALI,Ep ...
WALL SHEATHIN INLP SVSTEMp ,
OVERLAP TAPE A MINIMUM OF
WNCH AT ALL TJOINTS
USE FLANGED ELECTRICAL.
BOXES OR MEMBRANE FLASHING
TO PROVIDE FLANGES FOR .
ELECTWCALSOXEs
8Y61FL�WNL 6�ATIO,IG
wom oq LT. UlWALIrnmi
-1___!/R _ - .
1@ M mG""AT
PINELEG 111EM
WOYEGPROFmmwG
-
.
GM=TEEMTAIFP6TALLm
W4LP .WaYSTE"
WIEAT?P"
GYEFUPTHEA lw
T�ATMLT.A-n,
W TIt1. LP i1'SRt10 THE �T IL.
IDITEAgII COAxE0.4
FFA571AEN W
.
SWAM
coM Oa Lom
N
WALLASSEMBLY -
VINYI,/WOODIFIBER CEMENT SIDING
(INSTALLED IN ACCORDANCE WITH
CLADDING MANUFACTURER'S
INSTALLATION RECOMMENDATIONS)
ZIP SYSTEM® WYALL SHEATHING
WOOD OR LT. GA- METAL STUDS
TOP EDGE OF FLASHING TAPED TO
WALL'SHEATHIWIZ
TAPE OR ADHESIVENG BACTHKEDIPSYSTEM®
_
FLASHING. (MUSTMEETAC148)
CODE APPROVED FLASHING
FOUNDATION
--TUW-QWIWER CEMENT SIDING
INSTALLED IN ACCORDANCE
CLADDING WNUFACTUREAS
INSTALLATION RECO W/ENDAnpNSI
IP SYSTELIO WALL SHEATHING
WOW OR LT. GA METALSTUW^
.1"CH DAP RECCMMENDEDAT
PANEL EDGES UNLESS
OTHEMMSE PROVIDED BY 'tiy
YACHOlED PROFILED EDGES
ZPSOVER AL JOINTS
I"ZOSYSTE
OWALL VER ALL D1aPSYBTE/A0
OVFFIMTAPEA 1111" IY OF
\\�
14MCH AT ALL7iJDITTg
IAFWCH DAP RECOMMENDED AT.
PANEL EDGES OTHEFNAEE PROVIDED D BY
MACHINED PROFILED EDGES
FASTEN ZIP SYSTEMS WALL.
SHEATHING AS REOUBIED BY
DESIGNEROF41SCORD OR LOCAL
a1DDWOCWE
WALL ASSEMBLY
BRICK VENEER
AIR SPACE (AS PRESCRIBED BY
LOCAL BUILDING. CODE)
•�,�j
ZIP SYSTEM® WALL SHEATHING
WOOD
.`�\�:
OR LT. GA. METAL STUDS
TOP EDGE OF FLASHING TAPED
WITH
�•;�
ZIP SYSTEM® TAPE OR
ADHESIVEBACKED:FLASHING.
�•`� ,
(MUST MEETAC148)'
. .CODE APPROVED BASE
FLASHING' '
WEEP HOLES (AS PRESCRI13ED
BYLOCALBUILDING CODE)
WALL ASCF1d8LM
BRICH.YENEER
AIRSPACE (AS PRESCRIBED BY
LOCAL BUXMNG CODE)
.ZIP SYSTEMS WALL SHEATKNO
WOOOOR LT. GA.METALSTUDS
1M*ICH GAP RECOMMENDED AT
PANEL EDGES UNLESS..
OTHERWISE PROVIDED BY .
MACHINED PROFILED EDGES
21P SYSTEMS TAPE (I15TALlED
OVER ALL VOINTS IN LP SYSTFJAS
.WALL'SHEATHING}
OVERLAP TAPE A 14INIMLBI OF N
1 INCH ATALLTJOINTS
I1a4NCH GAP RECOMUENDFO
ED BY
OR LOCAL .. .
Ote. Far optimal air leakage reduction, all untaped'edg'es of the panels can be caulked, gasketed or sealed with a weather stripping material.
ZIP:System Sheath in9Installation Details on Walls (continued)
WALL BEYOND.
WALL ASSEMBLY
BRICK— VENEER
BACKDAM PER .WINDOW
AIR SPACE (AS PRESCRIBED BY
• `` i
>•,;
MANUFACTURER'S INSTALLATION
RECOMMENDATIONS
LOCAL BUILDING CODE)
•'•
ZIP SYSTEM® WALL SHEATHING
\; •.• •.,
.WOOD OR LT. GA, METAL STUDS
INSTALL CODE -RECOGNIZED
��.
SILLIPAN FLASHING IN ROUGH
TOP EDGE OFFLASHING TAPED
`,\'.
OPENING PRIOR TO WINDOW
INSTALLATION.
WITH ZIP SYSTEM TAPE OR
ADHESIVE BACKED FLASHING'
(MUST MEET AC148) --
CODE APPROVED FLASHING ..
WEEPS (AS PRESCRIBED BY
LOCAL BUILDING CODE)
STEEL LINTEL
INSTALL WINDOW IN
ACCORDANCE WITH DETAILS
24A-24D OR.25A725D ..
WALL BEYOND
TOP EDGE OF FLASHING TAPED'
WITH 110,
P SYSTEM®TAPE OR'
ADHESIVE BACKED FLASHING.
(MUST MEETAC148) ----�
`
WEEPS'(AS PRESCRIBED BY
LOCAL BUILDING CODE)
`rsz s
CODE 'APPROVED FLASHING
WALL ASSEMBLY
BRICK VENEER
AIRRSPACE (AS'PRESCRIBED,BY
LOCAL BUILDING CODE)
ZIP SYSTEM® WALL SHEATHING
WOOD OR LT. GA. METAL STUDS
WALL ASSEMBLY
CODE CODEAPPRpVED CLADDING
(INSTALLED IN ACCORDANCE WITH
CLADDING MANUFACTURER'S
INSTALLATION RECOMMENDATIONS)
EXTERIOR RIGID INSULATION
DRAINAGE PLANE (MIN. Y")
ZIP SYSTEM@ WALL SHEATHING.
WOOD OR LT. GA. METAL STUDS
TOP EDGE OF FLASHING TAPED TO
WALL SHEATHING WITH ZIP SYSTEM@ .
TAPE OR ADHESIVE BACKED, .
FLASHING. (MUST MEETAC148) =
CODE APPROVED FLASHINA;
FOUNDATION
Note: For optimal air leakage reduction, all untaped;edges of the panels can be caullied,,gasketed. or sealed with a weatherstripping material.
,w'"Wr i^' '�.'" k- i%' e.6,.., t ,. a. i.•4A',�'i`
"%.yi. 'ry w, w • .r; •': +�+i } # r+.. lk ;4 'ar, " '
7a`" x# a`~ t to 9 k,�^' ,r � ` 0 �, i, :; T� i h �a' � f�` 'w i iJ" i`�.,. >'' � ,��" *y�,•�a�•"' y'S'`^ s Y«''�"�` � �n�
1
"b ♦ w
i }
+, ,_ + ♦ :. � '� r. '�.' sr i� hcaxa�2q #v � ^-/,` 1.a p"��� � �"�++ k y
.. ♦ , "r, a^.:. J� � ima-ix� c �raraf .a�'rr..rfz� "" " :.'� � rc 3, �` '�`if i^ �^y x 1 i� c .�,# ,*- 1
- " „�:, �..a ar"` �, pie... FxUin � >..�• �,. €^ � `r
#,' � ,.. a. �• � "fit } i'�•. .,"+ # � r { "'� + J S� �^ � "* F �aa r" 1'�`-, i* s K. "+°{4 , ;�"'.r,K.�
} l,r* • r � a• � $ ;# r �"i < < !Y ,� ' 4rp� 4, .s �#�¢" ,� •�'' �4 � k.¢as �, •� �:'"� o +r # r• _.. �r
�, �. 1 t ha �i �"'°i. �* ,.e x�.. a` •� �,�� � � { Y �.�,� `�e?m$,`„ e��k" �' "� '' � � � �", 9 `'7� # � � ,e '�t:
r , - - "'rr 'i = - r s *^x� , r,ar -max a '�, ♦ s �`_ '
�
�` � � { ♦t r . * s � *#q..`3�+ p °'et i � L � ,�"+�* `" �1 �"+�' =v s � ,��� "�. �' �� � •a'J".a�'+" ' '� �'^• «' ,R`'.�.,
Iry ,,* bl.. ` ¢ r4 ° a tn*k "a .t m•` E i •:n "ryr•
T. r
oy
S� .�--7 ���T �, x `�,• *• �.i° �{r h`�' rah t� o li�,'�,;c t ,'} `"� � .�;
i
7S x ,11 i Y a ix r a
LL
•�� tV? rr '�,ti tL�"'#� �`[ .'�"` �w+`'o: ��,s�'"A"�.ryyY 5��:. �y�' d n�A * w �.w�jk p'pq}�' 4.�'� x;'?' .,� R� .`�i^.'d
A ,�M.�+Yµv «. f,4�� atc Y�.' "M._�yn j? *� r �;,. •' y°3a f 'r '*Pa.'
� � tom• � "yam"}{ �'1i s,�� � w'. �R � 8
44
i. • s a. i �- y y M ,+' w� ry Y � . i �r_ �J r 4 ys § � ^e �?' � �dC' �e t` .� R �'' `�' r� ] + ;_ � �� k ;ka+s
f!' � C ' � r *• �,` ,G Sx " ilR
,k,:,W r % a G r, ^ •�;``,.. `` ^« r ,+a yd ` R g +'iiyG
°��w ati'r � �,y �� � of +.�•.: rr' ,: ��,c Y 4"+r. 1 ry `` s� 1`w 'Lk 4 �,.
.� �.. �+} ^ rx � � yyA..� `. � � a , *. r r � �� ,`.rt` _� �,�"`'1•« s`� '6-�, � - �,#,� k w -: ��n `���y � r R. ' , ,Yr +,'
#, . 4 � ',l�. r r ,:,•r«'�.y�, �' �' :i"��#r ' 9 ^+ems r °a'. y""•`•� Mt � � � '� � � < �,
S„ a '•E � 'L= ,g �` �' I, f"a�• n�;` f t x�".Se'P j. ,th.4 p e�, ,� � `�"" y "E 'g'•n#
z rxs
47.
�` .. �,' S '„y c # � r »� ;�" `, � ' r � "�' � � • r rq d ,� vnv aA_ `'*, r, R A.
Y q ,• r ", - C r ii' ~R r � it e, - ~+ 'f •.- . •"+�
, E r
! - " "r ,+ -' ,�' ' • .. .� r*a` a -♦ .=`fir
{ � • , .K. f+rrw,.. r , , +.•ra" f wa ':9".v ,"'�" .d '4:ae"f% .�+i.�`�k.LorF` 'µ' + ' r F �•
ZIP SYSTEM® SHEATHING WITH HARD COAT STUCCO AT:
BLOCK FOUNDATION WALL- OPTIONA-
..H 2:
TRADITIONAL HARD -COAT STUCCO.
-'
INSTALLED IN ACCORDANCE W" THE
LATH
i .:.MANUFACTURER'S OR THE PORTI.AND
' CEMENTASSC,(PCA) '
RECOMMENDATIONS VYITH THE MOST
r: - =• RESTRICTIVE CONTROLLING.
ONE LAYER OF WATER.RESISTIVE
VAPOR -PERMEABLE BARRIER
WITH A PERFORMANCE AT LEAST
EQUIVALENT TO GRADE D
BUILDING PAPER
ZIP SYSTEM® SHEATHING'
,
TOP EDGE OF WEEP SCREED
TAPED TO WALL SHEATHING'
• -
WITH ZIP SYSTEM® TAPE OR
:+ •:
ADHESIVE BACKED FLASHING,
'
(MUST MEET AAMA 711 OR
AC148) -
i::,�
WOOD OR LT. GA.
METAL STUDS
ADHESIVE SACKED MEMBRANE
'
"•
BRIDGE FLASHING CENTERED
OVER TRANSITION JOINT (ZIP'
SYSTEM TAPE MAY BE USED AS
e
THE BRIDGE FLASHING)
o
0
CODE -APPROVED
:WEEP SCREED AT
BASE OF WALL
... VERTICALANDHORIZONTAL
CONTROL JOINTS AS NEEDED.
= :'
DESIGNER -OF -RECORD TO
SPECIFY TYPE AND LOCATION.
MASONRY BLOCK WALL
7JP SYSTEM® SHEATHING IS APPROVED TO REPLACE. ONLY THE
FIRST LAYER OF A TWO- AYER UNDERLAYMENTSYSTEM.:
DRAWING_NOT•TO SCALE
N
'����'"
Sales Office:_ 70925 pavid Taylor Drive
o
Suite 360 : Charlotte; NC 28262
o
SHEATHING 8 TAPE
Telephone:.800.933.9220 - www.zipsystem,cam
�Ui`
�I II
D ENGINEERED
Woons
es e construction etails are provided to assist.in a nstal allon o ZI ystem product s) and'may'not apply to
every situation.. Manufacturer accepts no responsibility liability
or for the
use of these or other construction details.
ZIP SYSTEM®SHEATHING WITH HARD COAT:ST000O AT
BLOCK- FOUNDATION WALL ' OPTION A:.-.. H '2
WALL ASSEMBLY ...
�.
TRADITIONAL: HARD -COAT STUCCO
METAL LATH
ONELAYER WATER-RES. BARRIER '
ZIP SYSTEM® SHEATHING" '
W00D OR LT. GA. METAL STUDS
TOP EDGE OF WEEP. SCREED
TAPED TO WALL SHEATHING'
WITH'ZIP.SYSTEM® TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AAMA 711 OR %
AC148)
CODE -APPROVED WE
SCREED AT BASE OF WALL
ADHESIVE BACKED'MEMBRANE
BRIDGE FLASHING CENTERED OVER . 1
TRANSITION JOINT (ZIP SYSTEM.: 1 ...
TAPE MAY BE USED AS THE BRIDGE
FLASHING)
MASONRY BLOCK WALLap
`
.. ` _ ..
i.AT11 — \ r .
TOP EDGE OF.WEEP SCREED TAPED
TO WALL SHEATHING WITH ZIP \
SYSTEMS TAPE OR ADHESIVE BACKED
FLASHING.:(MUST MEET AAMA 7'I1' OR
AC148) ...
TRADITIONAL HARD-COAT-sTUCCO
INSTALLED IN ACCORDANCE WITH THE. \
MANUFACTURER'S OR THE PORTLAND
:CEMENT Assc. (PCA)
RECOMMENDATIONS WITH THE MOST' ....
RESTRICTIVE CONTROLLUNG. I
ONE. LAYER; OF WATER -RESISTIVE ,
VAPOR -PERMEABLE BARRIER WITH A
. . . PERFORMANCE AT. LEAST EQUIVALENT
TO GRADE D BUILDING PAPER.
COD&APPROVED WEEP
SCREED AT BASE OF WALL
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED OVER
TRANSITION JOINT (ZIP SYSTEM
TAPE.MAY BE USED AS THE BRIDGE
FLASHING) : .
MASONRY BLOCK WALL• ., . '
'ZIP SYSTEM®SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO LAYER.UIVDERIAYMETYI`SY$11<MOT TO'SCALE
Sales Office:-10925 David Taylor Drive
. Suite 300 - Chadotte, NC.28262 .. Ws
D ENGINEERED
SHEATHING TAPE Telephone::600.'933.9220 - www.zipsystemcomU u r WOODS
ese construct on etai s are provi a to assist (n the insta atlon o IP stem
y proot apply to
everysituation. Manufacturer accepts no responsibility or Ilabirty for the use of these or other construction details.