Loading...
HomeMy WebLinkAboutProduct ApprovalFlorida Building Code Online Page 1 of 2 RECER1 ._D AN 0.9:2017 :.: "' r1" Bug r &r Ulat i a eas Hdrirc J_:Lop In I user ReyKiratlon ± Not 7opks .Submit Surchalpe :. StaLS fi Facts. PuEltotlons I FBC Stiff r 'acts Site Map ! Links ' OFbdda Product Approval = USER: Public Use r. :- .. , dP➢llGdtlDO.Llit > Application Detail . . FL # FL17147-RI Application Type' Revision Code Version 2014 Application Status Approved Comments Archived.. Product Manufacturer Huber. Engineered Woods LLC. Address/Phone/.Emall. 10925 David Taylor Drive Suite:300 Charlotte, NC 28262 (704) 548-5442 ' ' kurt.koch@hubei:com Authorized Signature Kurt Koch •kurt.kocq@huber.I om Techrilcal' Representative Ken W. Htx Address/Phone/Email 1446.Hwy 334 Commerce, GA 30530 (706)336-3041 ken.hix@huber.com " Quality Assurance Representative Walker Campbell Address/Phone/Email 1446 Hwy 334 Commerce, GA 30530 (704) 562-1053; walker.ca�mppell@hu6er.com Category Struchiral Components, Subcategory Products Introduced as a Resuit:of New Technology r Compliance Method Evaluation Report from a Product Evaluation Entity. Evaluation Entity, ICCEvaluation Service, LLC Quality Assurance Entity ICCEvaluation Service Quality Assurance Contract Expiration Date 10/01/2017 . Vaildafed: By ICC Evaluation Service, LLC. Certificate -of Independence FL17147 R1 COI'Lertificate of ind a ' + nra rrir gvaluation.odr Referenced Standard and Year (of Standard) Ye;9t. ICC-Evaluation Service'AC310 2015; Equlvalence of Product Standards Certified By Approved Evaluation Entity FL17147 RI Eauiv AC310 odf Section41rdln the Code File. copy https://www:floridabuildin :or r/ r a dtl.as x?� aram=wGEVX wtD *Co3Ea iI1Bd... 4/12/2017 g �P P PP— P P Q ... q P ' Florida Building Code Online Page 2 of 2 Product Approval Method 'Meibbd 1 Option C Date Submitted 06%31/2015 Date. Validated 09/16/2615 Date Pending FBC Approval Date Approved _ 09%20/2015 h Summa' of Products pL # Model, Number or Name Deseription 17147.1 ZIP System (R) Wall.Sheathing ZIP System (R) Wall Sheathing Limits of use Approved.for use in HVHtt'No Installation instructions ' . Approv®d for use outside HVHZQ YPS Impact:Resistae: No EL17147 RS II ZIP she�thlna Inctali R anal �m� SF V,eriFled By; ICC Evaluation Service, LLC Design Pressure: N/A. Created b'y Independent Fhlyd'Pa rtY, Other; limited to structural aspects of panel Sveatedon Re FL17147 111' A ' RqR1d7A —If • Beck Ne,R contact ij :::'2601 Blair The State of Florida IS an AA7EEo employer. Ccovrlehr . r3lene head 'rti1Ph- - ^ Dhenrr• as0.4s7-Se24 2007-�01+ tat of Flo 'ic :: ffiYdcv_ C�temr t .. :: 6[ass161ii- HS[an"^"^I :: Amend cr�I.nvn� Under Florida law, email addresses are pubrk awards. B you do not want your a -mall addressreleased in rvspcnsg m apublic-records request, do not send electronic mail to this anety. Instead, contact the office by phone or by traditional mall. If you have any questions; please Contact a50.497,1395: -Pursuant Section 455.275(1); Florida Statutes, effective October 1, 2012, to licensees licensed under Chapter 455, F.S. must provide the Department with an email address B they have one. The smalls Provided may be used far oN1Ual communication with the licensee. However email Sddressrs are public record. If you do not wish to re Public supply a personal address. Please provide the Department with an email address which tah'be card . made available to the pu6tic. . . detem ne�qyou are a Inotlwis under Chapter 455, F.S., please dick hM. Product Approval Accepts! . 'Credit Card Safe 6. h4s://www.fl'oridabuild-ing.or—&tj 4%12✓2017 6 w ZIP:System®Roof & Wall Sheathing INSTALLATION MANUAL -r system Contents FASTER. TIGHTER. ENERGY EFFICIENT. 02 ZIP System® Sheathing Installation: On Roofs : 08 ZIP Systems Roof & Wall Sheathing Window 03. ZIP System- Tape: Installation - Installation Flanged WtndowS &: Brick Mould Windows :Roof Panel. Seams '04.i - •09. ZIP�Systeme Roof ,& Wall Sheathing'=:Window ry ZIP System Tape. Installation = Installation Brick Mould Windows (continued Roof Panel Seams. continued 10 Z1P System® Roof & Wall. Sheathing - 05 Roof Covering Installation .Instructions Penetration, Openings 06 ZIP System° Roof &,Wall Sheathing installation 11 ZIP System® Roof & Wall Sheathing Installation Details 07 ZIP System Tape Installation,- Panel Seams 12: ZIP System® Roof. & Wall Sheathing installation Details (continued) ATTENTION: This installation guide is:interided -to provide general information ior_the designer and end user. The following :ZIP. System Roof & Wall sheathing can be used with a range of exterior guidelines.:. will help you safely end properly install the ZIP System°Roof & Wall wail sheathing. We urge you,: and anyone installing. claddings and roof coverings.:Approved wall oovoings include brick, vinyl, stone, wood fiber cement, wood and. cedar shakos... raditional hard this product, to read.theae guidelines in order to minimize any risk of safety hazards and to prevent voiding any applicable coat stucco and specifled drainable EIFS_ gpplications, however' it: is not recommended for -use .with adhesively attaced EIFS. Approved roof warranties. This manual is , a general installation guide and does not: cover every installation condition. Proper inatallation shall be deemed 'the coverings Include asphalt -fiberglass shingles, metal -files .and panels, day and concrete tiles, slate and slate type shingles and wood shakes'and shingles. to mean most restrictive requirement apeeified oy Huber Engineered Woods ((iEW), Follow all claddirig'and roof covering manufacturers installation instructions. local building code, engineer or architect. of record or other authority having jurisdiction.. lfou:are fully and solely responsible for all safety requirements'and;coda ZIP System Roof &Wall sheathing 'can be used on buildings of Type ill. (Roof Applications ONLY) and Type V compliance. For additional information contact Huber Engineered Woods LLC. construction anti construction permitted under the IRC. ZIP System° Roof a Wall Sheathing Safety Guidelines - Follow all OSHA regulations and any other safety guidelines and safely ZIP Systems Roof & Wall Sheathing lneludes; - ZIP System sheathing panels with built-in moisture barrier with preprinted fastening . practices during installation and construction. and tape guides ZIP System tape - Use approvedsafetybettsand/or hamessesorotherfallprotodonequipmerd _ - !nstalli0 System panels and tape only in dry conditions and on dry. surfaces. Do Storage and Handling not install, In.rain, snow, frost orottier slippery conditions. Wear rubber soled or other high -traction footwear white installing ZiP System -Set panef.stack on three supports (stickers) to keep off the ground.'' - Outdoors, cover panels to with waterproof Protective sheathing in a roof application. Do not wear'foofweai with worn soles or heels. - Ensure .the roofing surface is free from oil, chemicals, material. 'Anchor covers on top of the stack, but keep away from sides and bottom to assure good eirculatlon. sawdust, oirti ;tools, electric cords, air hoses, cloVng arid. anything else that might: create a tripplh9 hazard. air - In high molsture;environments, cut. banding on the panel stack to prevent - Install temporarytoe boards along the ZIP System sheathing roof surface: edge damage. ZIP System• Roof &Wall: Sheathing Notes and Limitations What. Is ZIP System° Roof & WeI1.Sheathingl = Do not use on roofs with'slopes less than'2/12; ZIp:System Roof &Wall sheathing.is code recognized as a wood structural panel, -roofing... underlayment (ICC-ES ESR-1973); - Do not use abutted against general stone or masonry without providing a minimum of a 1/2' gap. water -resistive barrier and air barrier (ICC-ES ESR-1474), ZIP System Roof &Wall sheathing' has a •built-!n moisture bamer• Do not install ZIP System tape in temperatures less Than 20°: F ZIP System products are not recommended form' that lets ycu say good-bye. to building paper or hous.'ewrap on the walls and:felt paper on the roof.• Simply, install the housing applications that are built under a' federal building code administered by the seams, and you have a structural wall sheathing; water- p resistive resistive barrier and, air barrier or a structural root sheathing and roofing the U.S.:Department of Housing and Urban.Devetopment (HUD). Do.not use panel edge dips (H-Clips) vMZIF System Roof & Wall sheathing undedayment.all from one product. without expressed written approval from Huber Engineered. Vlloods." Do. not use ZIP System. tape to permanently seat around circular roof Projections' (plumbing vents, pipes, curved walls, etc.) r Contents (continued Wall Coverings - ZIP System Roof & Wall. sheathing :should be covered with the.finlshed roof covering or exterior cladding within 180 days of installation. Finished roof and extertor'cladding products, should be installed, per the manutacturer!s installation instructions. - Per the recom►iterldation of the Western Red.Cedec Lumber Asso_ ciatlan and the-U.S. Forest Products Laboratory, wood siding should: be primed before installation. When orgtnal roofing or claddings are removed and replaced on existing ZIP System sheathing; the roof or wall should tie' covered with an additional: roofing.undedayment or water resistivebarder prior to installation of the .new finished roofing or cladding., Note: In cladding systems requiring multi Pie of watar-resistive harriers, like traditional hard -coat stucco, Zip System shetithirig Is intended only to replace the firstlayer. Wet Blown Cellulose Insulation In addition' i to following manufacturer installation instructions, we'recom_rrend a maximum moisture content of the celtulpse of less than 25% measured at the inside stMace of the ZIP System panel before closing the will cavity. Secondary.Coatings Do not apply secondary coatings or treatments to ZIP System Roof & Wall sheathing :paneis:with the exception of the following: HEW approved fire resistant. coatings. Fire resistant coatings must be tested and approved liy HEW.for use with ZIP System panels. Field applied water soluble borate insecticide or fungicide treatments applied,to the non overlay side .of the panel. See technical tip, Termite Treatmentsan ZIP System Roof& Wall Sheathing," on iipsystem.'corn for more information. Permeable laminated radiant barrier foil or paint.. For a radiant bonier foil or coating to be considered permeable, it must have an applied permearice of five palms or greater as tested by.lhe:AS fM E 95 wet cup standard. Fora radiant foil, the pe.rmeance evaluation would include any adhesive and/or backer used to laminate a: foil; For a radiant pairit/coating, the permeance evaluation should be condutited at the applied thickness of the paint/coating. ZIP System Roof and will sheathing replaces only the first layerin.muto+undedayment systems. Edge support is not required by code with 1/2 (32/i6 span rated) and 61B (4MO span rated) performance'dategury sheathing it the framing does nal exeed 24' e.o. and the total load does not exead 93 psi fat M and t56 psi for US performance categories. Thisis based an Mao deflection vitena for total load. ZIP.Syster0 Roof & Wall Sheathing Installation Manual 02 ZIPS... tem° Sheathing.litstallation on Roofs Overview: ZIP System Root &Wall sheathing is Composed of ZIP System, panels and ZIP System seams sealing tape. ZIP System' Roof 8-Wall Sheathing panels should be fully installed before, the seem sealing tape is applied; In general, the ZIP System roof sheattiing'panels should be Installed from the lowest'point on the roof to the highest It is at the discretion of the instafier whether to apply tape from the top down ar from the bottom up.: However, workio from the: st p9jst sections of- the roof and worldrtg clown will minimize foottraffid on the tape. The following Installation steps are.presented as guidellnes.and.a general outline of the installation process. These are manufacturer.Instaliation recommendations -please visit zipsystem.com tor.a library of flashing and installation details. You are fully and solely responsible for all safety requirements Good construction and:safety, practices should be followed at all times. Step 1: Ensure that the panel surface is dryand Gean of any nails; sawdust, or . other debris.or protrusions prior to Installing or walking on the panels. • After ensuring :compliance with all"OSHA and. local code safety . guidelines, Install ZIP *09m- sheathing g panels w8h the moisture barrier surface facing:outside.:7he long edge (81) should be oriented perpendicular to the framing members, -and panels should'be' installed with the 4' edge: seams staggered a minimum of 24'. .1/8' spacing between square edges of a0 adladent panels is recommended, in accordance with industry standards for wood sheathing: (Tongue & Groove panels are designed.to.self-space and do not -require manual e' Panet Edges 4' Panel Edges spacing_ on the 8' edges.) its, 1fir x t + The unique edge pro@e is Maintain 1/8• space designed to accommodate where 4' edges:meei. Incremental panel Unique edge profile is on expansion'and does not W edges only. require manual gapping along the 9 edges; te Ensure that ZIP System panels span at least three framing members and a framing -member supports the entire.4' edge: of the panels. w - Fasten the System Roof & Wall' sheathing panel to the framing.: members With code approved. fasteners spaced at the appropriate edge"and intermediate spacing..ltIs the responsibility of the general contractor to verify proper fastener type and spacing priarto installation. - Apply the fasteners•3/8' from the panel ends and, comers. An Ideal installation would be where fastener heads are flush with the ' panel surface. However, due to variations in materials and limitations on equipment, this may be difflcult to achieve in some situations. It Is not required to tape over overdriven fasteners' unless the fastener head creates:a :hole through the entire panel.thickness Please see. the.technlcaf tip; °Overdriven Fasteners in ZIP System Roof and Wall Sheathing," for more information. Install temporary toe boards as necessary'When applying the ZIP System sheathing. panels up the slope of the roof planes.: all 03 ZIP Sy;3teln"' Tape. Installation - Roof Panel Seams Apply ZIP System tape utter all ZIP System Roof & Wall sheathing panels are fully fastened to roof -framing mem6 rs. Only ZIP System tape should be used to seal the seams of ZIP' System panels. Ensure that the panel surfaces are dryand free of any nails; sawdust�arid other debris, or protrusions, Avoid stepping. . anaape in high temperature environments. ZIP System tape is a: contact tape that requires pressure for an adequate sash . v. Step 1. apply - ZIP Systemtape.to every vertical and horizontal panel seam. It is at the'discretion of the installer whether to apply to a from the top down PP Y P or.from the bottom up.' However., working.from the highest sections of I roof and working down will minimize foot traffic on the tape. - Ensure that the tape'Is centered over the. within +/-1/2° to provide - adequate coverage and to ensure that wrinkles in the tape are minimized. Ensure that tape lengths are continuous across the 8' horizonlat edge ci the panels. If splices are unavoidable, creat6 an' overlapping splice of at least 3':'Apply moderate pressure onto the surface of the tape -to ensure a secure bond between the panel and the tape. Use ZIP System tape gun, or tape roller to apply pressure to the tape and smooth out any.wrinkles: Take special care to remove any voids.andlor (rapped air at splice areas and T-joints. Ste 2 P For valley areas of framing, we recommend you use 6°.wide ZIP System tape: This tape is wider than panel seam tape and Is designed to give you optimal protection In valley areas Starting from the bottom and working your way up; apply one continuous Piece of.6' tape so that the center of the tape!' over the valley seam. Use the tape gun or tape roller to apply pressure to the tape to ensure Proper contact with the: panel and to eliminate any wrinkles that might have occurred in the tape. Take special care to seat tape completely Into the valley: : . Note: . It is important to pay.extra •attention to valley taping as:water is directed toward the valleys during rain events. . - Self -adhering ice and water barriers. maybe required by code. ZIP System tape is not considered a replacement -for self -adhering ice. . . and water barriers. Therefore, when self -adhering to. and water barriers are required,: they should be installed in addition to ZIP ystem tape: . . ZIP System* Roof &Walt Sheathing Installation Manual 04 ZIP System'" Tape Installation - Aoof Panel Seams (continued) [Ste.p3' if6.ZIPS System yst tape is riot available, use two continuous pieoeti of 3.75- ZIP System panel seam tape over. the entire length of the valleyseam, ovedapping.the"places on the Valley seam by at least 1'.' tariingthe bottom, Install the first:piece of tape overlapping the... valley seam' by at least. f ". First piece Use the tape gun or tape roller to apply pressure to.the.tape to'' nsure t proper contact with the panel and to eliminate any wrinkles that might have occurred In the tape. Apply the second piece of tape, overlapping the first piece In the valley' "seam: by 1'. Repeat use of the tape.guri:or roilerto make sure the:tape is adequately adhered and tightly pressed into the valley seam. Note: : second piece d tape It is important to pay extra attention to valley taping as water is directed toward the valleys during rain events. Self -adhering ice and water barriers may -be required by code. ZIP System tape is not considered a replacement for self-adhering"ice and water barriers. Therefore, when self -adhering ice and water ... barriers are required, they should be installed in additinrrto ZIP ravedap System tape. ep.4.. To, provide temporary, weather' .protection to roof/Wall' intersections of dormers or other wood -sheathed projection;, apply 2" of the tape Width up -the; vertical projection from Where it:intersects with the roof. The remaihing tape width can be adhered to"the.Zip System roof -sheathing panels. Use the tape.gun or tape roller to apply pressure to the tape and smooth " out any wrinkles: Step 5. Install ZIP System tape over hips and Odges by centering the tape over the peak seam'. Apply tape in sufficient length to'completely extend the length of the hip or ridge. Starting from.the lowest point of the hip and working up, press tape Into Place keeping tape centered over the hip. Apply moderate pressure onto the surface of,the tape to ensure a secure bond between the panel and the tape. Cut ridge tape as required" for ventilation prior to Installing ridge vent. Step 6. Tape:over toe board nail holes once the toe boards are rembved,.working from the highest toe boards to the lowest., Roof. Covering Installation Instructions ZIP System Fioo}.& Wall sheathing is a code recognized sheathing and underayment and is approved for:use.wlth the following roof coverings: Asphalt -fiberglass Shingles = .Metal Roofs (shingles and panels) - Clay Tile Concrete Tile Slate and Slate type Shingles - Wood Shingles - Wood Shakes Wheninstalling roof coverings, follow applicable codes and Manufacturer's.suggested Instructions. Some root coverings require aslip-sheet.In addition to conventional underiayment. Where slip -sheets are:required, they should be Installed aver ZIP System sheathing panels. Note:. Visit zipsystem:corn for,updates. and installation details. Asphalt -fiberglass Shingles Apply asphalt -fiber es directly to ZIP System sheathing: For roofs with a slope of.2/12 or greater but less than 4/12, additional undedayment:may be required. Install asphalffibeglass shingles according to applicable codes and manufacturer's installation Instructions. Metal Roof Coverings Metal roof coverings may be applied to codes -are foil owedZIP System sheathing provided that the roof covering manufacturer's Installation Instructions and applicable ... Fasteners used to, secure the ZIP System,Roof S Wall sheathing panels to.supporting framing must be compatible with the specific metal roof covering used. Galvanized fasteners -shall be used with galvanized roof_coverings; aluminum -zinc -coated fasteners shall be used with aluminum-ino coated roof coverings and 300 series es stainless steel fasteners shall be used with copper roofs. Stainless steel fasteners are acceptable with all metal roof types. In addition; metalroof flashing shall also be made of a material compatible with the specific metal roof covering used. Apply metal shingles'on roots with slopes of 3/12' orgreater: Clay and Concrete Tile Roof Coverings ZIP System Roof & Wall sheathing is Intended to replace the first layer in a two -layer or.muftklayer underiayment system. When installing clay or concrete tile roof coverings, follow the installation recommendations of FRSA/TRI.07320. Install fil Installation Instructions. e roofs according to applicable codes and manufacturer s Slate and Slate -type Shingles Apply slate and slate -type shingles on roofs with slopes of 4/12 or greater. Install slate and slate -type shingles according to;applicabla codes and manufacturees Installation instructions. Wood Shingles ZIP System. Roof &Wall sheathing is Intended to replace the first layer of underiayment required by the 18C and/or the IRC. Additional layers of underlayment may be required by code depending on the local climate. Apply wood shingles on roofs with slopes of 3/12 or greater.. Install wood shingles according:to applicable codes and manufacturees:tnstallation instructions. Wood Shakes ZIP System Roof $Wall sheathing is intended to.replace the first layer of underiayment required by the IBC and/orthe.IRC. Additional layers of underiayment may be required by code depending on the local climate. ZIP System roof sheathing is not.to be construed as a replacement for Intedayment. Apply.wood shakes: on roofs with slopes of 4/12 or greaser. Install wood shakes according to applicable codes and manufacturer's installaton instructions. ZIP System' Roof &Wall Sheathing Installation Manual 06 ZIP: $ystem® Sheathing ,Installation tyn. Walls Overv(ew: ZIP.System Root & Wall sheathing is composed of ZIP System pariels.and ZIP System seaniseating tape. ZIP System° F... p Wall Sheathing Panels should be fully'installed before the seam sealing tape. is applied. The following installation steps are presented as a .general outline of the installation process: These are manufacturer fristallation recommendations —:please visit zipsystem.com-for a library of flashing and insfaliatian details. You solely responsible for all safety requirements. Good construction and safety are fully and practices should.be followed at all Umes. ZIP ' System Roof & Wall !sheathin g panels positioned With water -resistive barrier facing outside: The. panels may alled with the long .side of the panel oriented either tal) or'verticalty to the framing members. Walls that'are` lall " d to resist lateral shear forces :and sheathed with wood: l panels typically require solid framing or blocking behind l edges. If oriented hodzoritally, block horizontal Joints if Wallis designed for bMciog or, as a shear wall: VT spacing between square edges of -all adjacent panels is: recommended -in -accordance with Industry'standards for.wood _sheathing installation, 8' and O B' Panel Edges Penet Edges 4' Panel Edgee II II . II The unique edge profile is Maintain 1/8, space where Maintain 1/8- space designed to accommodate B' panel edges meet 4' where 4' edges meet, incremental panel. panel edges. Unique edge Unique edge profile is• on expansion and does not profile does not provide 8' edges only., require manual gapping the full 1.18, recommended along the 8' edges.• 'space id this situation., Step 2. Fasten the' nets to the framing members with code approved fasteners. Space fasteners s- o.o: along supported edges and 12° o.c. at intermediate' supports,; unless otherwise specified by'local - code or the designer of redord,' It is the responsibility of the' general contractor to verify -proper fastener type and spacing prior.to installation: Apply the fasteners 3/8' •Jrom the ends and corners.. An -ideal installation would be where fastener heads are flush with the panel surface. However, ,due to variations in materials and limitations on equipment, this may be difficult to -achieve In -some situations: It is not required fo tape over overdriven fasteners unless.the fastener head creates a hole through the entire panel thickness. Please see the technical tip 'overdriven -Fasteners in Zip System Roof and. W611 Sheathing," on ilpsystem.com for more information.. M. ZIP $ysteln'" Tape Instillation - Walt Panel. Seams Apply ZIP System tape utter all ZIP System Roof & Wall sheathing panels are full fastened to wail -framing members, Only ZIP System tape should be used to seal the seams of:ZIP System panels. Ensure that the penal. surface is dry a d free. of. sawdust and dirt prior to. taping. System tape that requires pressure for. an adequate seal, ZIP. tapeIs a contact ;. Step1. Tape:all;seams using ZIP System tape; Ensure that the tape:. %s centered over .the. seam within 4- i/2" to provide adequate :coverage and that wrinkles in tape are minimal. Use the ZIP. System tape gun or roller to apply pressure to the laps ap and smooth• out any wrinkles. . Step 2 Wherever tape splices occur at a horizontal or vertical seam, create: an oJedapping splice Of -at .least 3'. At T-joints, the tape pieces should overlap by at leasf V.-Apply moderate pressure onto the surface of the tape to ensure a secure bond between the panel and the :tape; Use the ZIP System tape gun or roller to apply pressure to the tape And smooth out any wrinkles. . Take special care to remove any voids and/or trapped air at splice:: areas and T-Joints.. . 91ep:3. Tape Inside and outside comer seams. y1 � Inside comer seam .. :.. . . . Ouktde comerseam . .. _ Note: Tape.over any mews of the panel or tape that are damaged during, construction. ZIP system® Roof $'Wall Sheathing Installation Manual 08 ZIP System - Window Installation olscLAlmtR:TheroNowlnBclePsrepresentageneralwerviawfor the proparinslaRaftfo.fwlntlowtlash ,Pieesedetertdoorisufl the IrgteValion Instructions o1 your w ndow manufachirer as well as code requlremeida in your iurlsdkiion a full Instftll wh'details: Flanged Windows " Ftape may be used as pan flashing if n accordance With flanged -window details posted onzipsystem.com. sive-based(lashingtapes (must meeteptance; Criteria for Flashing Materials may be used as pan flashing If installed i per ASTM 2112--07. Apply the flashing to cover the bottom of the opening, overhanging onto the sheathing by at least 2" and extending a minimum of 6' up each, jamb. 3. Apply sealant around inside lace of mounting flange. Sealant must be gapped. at the sill to permit drainage. Install and level window per manufacturer's installation instructions. Verify. sealant compatibility with window manufacturer. When using ZIP- System. tape as pan flashing, butyl, lo0% silicone or polyurethane sealants are acceptable. Do not use:latex'or other water - based sealants. 4. Cut two pieees.6. ZIP System tape or another adhesive -backed flashing tape (must meet ICC- ES Acceptance Criteria for Flashing Materials (AC148)) and apply -to each of the window jamb flanges, ensuring .the jamb flashings overlap the sill flashing. Once.the tape is in place, use the tape gun or roller to seat the flashing to the sheathing. S. Cut a fength. of ZIP System .tape or another adhesive -backed flashing tape (must meet 1CC- ES Acceptance Criteria. for Flashing Materials (AC148)) and apply,to the header, ensuring that the flashing overlaps the jamb (lashings.' Once the tape is in place, use the tape gun or roller -to seal the flashing to the, sheathing. '�0 NOT Wpa bottom Qarige. I 6. From the Intefior,_apply low-pressure polyurethane:. foam (for windows] between the rough opening Ind the window frame. (Caulk sealant compatible with fhe. siiLtlashing may be used. at the; sill if the opening between the sill flashing and window is too narrow to allow the use of low-pressure { polyurethane foam.) a ! When using ZIP System tape, butyl, t00% ;s .-silicone or polyurethane:sealants are acceptable. Do not use latex sealants with ZIP System tape. If using another flasfing tape, follow the. flashing manufacturer's recommendation in selecting a sealant -compatible with that flashing: Brick Mould Windows 1. Fasten the ZIP System sheathing to the wood frame and install ZIP System tape to all wall panel seams, -as detailed in sections 02 and 03> . � 1 2 If recommended by. the window manufacturer, cut a strip of wood to function:as a back dam at the, sill. The wood strip should have a length equal to the width of the rough opening and a height and Width of at feast112". Position the block, at. the inside edge of the Window frame. !" y t i % 09 ZIP System — w%ift(IQ1A/ Installation asCuuMER:Thefokowingslepsrepresentageneral'odervew(orthe properlristagatldnolwintlowflashing.Please defer to/conauk the InategaUdn' nstructions of your w ndow manufactuMe as well as code raquiren�nrs in your jurisdiction for full installation details. Brick Mould IMndows (continued) 3. ZIP System tape may tie used as:pan flashing if installed in accordance. with brick mould window Installation details posted on- zipsystem.com. Other adhesive -based flashing tapes.(must meei- ICC-ES AcceptanceCriteria for Flashing Materials (A6148)) may be used as pan flashing if installed per ASTM 2112-07. Apply.the if to cover the bottom of the opening, overhanging onto the sheathing by:at least 2' and extending a minimum of 6' up each Jamb. 4. For vertical Janibs, cut ZIP System tape or ariother adhesive -backed flashing tape (must meet ICC. ES Acceptance Criteria for Flashing, Materials (AC148)) -and apply to each of the window Jambs. Ensure that they cover the entire inside of the rough n opening as well as overlap onto the' sheathing by at: least 2". Flashing shall also :extend above the \ . rough opening,.such that it will project 1' beyond ' the exterior trim of the window. Once the tape is in place, use the tape gun or roller to:seal the flashing to the sheathing. rd ly sealant to Jambs and header allowing for nage at the, sill in accordance with window ufacturer's. installation instructions. When g ZIP'System tape, use a butyl, polyurethane 00"/o silicone sealant Do not use latex or other water -based sealants with ZIP System tape. When using another flashing tape, follow the flashing manufac-turer's recommendations in " selecting a sealant compatible with that flashing: 6.' Iristall and level window 'per Mariufacturer's .installation instructians:_ V 7. Cut a piece of rigid head flashing so that when installed, (His flush with the edges of the exterior moulding of the window. Apply a bead of sealant to the back and bottom surface of the rigid head flashing, -Use sealant recommended. by. the Flashing manufacturer. 8: Secure the rigid head flashing to ZIP System wall sheathing. 9. Cut a length of ZIP System tape, or: another adhesive -backed flashing tape (must meet ICC-ES Acceptance Criteda for Flashing Materials (AC148)) and apply to the rigid head flashing, ensuring I hat the adhesive -backed flashing overlaps the Jamb (lashings. Once the tape fs in.place, use the tape gun or roller to seal the flashing to the sheathing. 10. From the interior, apply low-pressure polyurethane. - foam (for windows) between the rough opening and " the window frame. (Caulk sealant compatible with the sill:flashing may be used at the st fif the opening between the an flashing and window is too narrow to allow the use of low-pressure polyurethane foam.) When using'ZIP System tape, butyl,1 o0% silicone l or .polyurethane sealants are acceptable: Do not use latex or other 'water -based • sealants with ZIP System tape. If using another flashing tape, follow the flashing manufacturer's 'recommendation In selecting a sealant compatible with that flashing. ZIP System® Roof & Wall Sheathing in Manual ZIP System -Penetration Openings 01� � fep � RONing steps represagt a ge iersl overview for the proper instagadon of penetrat on f✓eshfng, please deter. Io/consuN Gu your iudsd ctian fadu details. WOO wiLrAsS,sEAiety LPS Al DWALL SHEA719F1G G GR LT. GA. METAL STt1D5 11e4NCH GAP RECOMMEND OAT PANEL EDGES UNLESS . . OTHERMSE PROVIDED BY . MACHINED PROFILED EDGES' h� T LNSTALLM SYSTEMOTAPEOR S' ADHESwE SACKED FLASHING (MUST MEETACty)IN.SEQUENCE FROM SOTTOM, SIDES, THEN TOP TO ENSURE SHINGLE LAP OF AONESNE BACKED FLASHING.a n\ ZIP SYSTEMOTAPE INST _ ( ALI,Ep ... WALL SHEATHIN INLP SVSTEMp , OVERLAP TAPE A MINIMUM OF WNCH AT ALL TJOINTS USE FLANGED ELECTRICAL. BOXES OR MEMBRANE FLASHING TO PROVIDE FLANGES FOR . ELECTWCALSOXEs 8Y61FL�WNL 6�ATIO,IG wom oq LT. UlWALIrnmi -1___!/R _ - . 1@ M mG""AT PINELEG 111EM WOYEGPROFmmwG - . GM=TEEMTAIFP6TALLm W4LP .WaYSTE" WIEAT?P" GYEFUPTHEA lw T�ATMLT.A-n, W TIt1. LP i1'SRt10 THE �T IL. IDITEAgII COAxE0.4 FFA571AEN W . SWAM coM Oa Lom N WALLASSEMBLY - VINYI,/WOODIFIBER CEMENT SIDING (INSTALLED IN ACCORDANCE WITH CLADDING MANUFACTURER'S INSTALLATION RECOMMENDATIONS) ZIP SYSTEM® WYALL SHEATHING WOOD OR LT. GA- METAL STUDS TOP EDGE OF FLASHING TAPED TO WALL'SHEATHIWIZ TAPE OR ADHESIVENG BACTHKEDIPSYSTEM® _ FLASHING. (MUSTMEETAC148) CODE APPROVED FLASHING FOUNDATION --TUW-QWIWER CEMENT SIDING INSTALLED IN ACCORDANCE CLADDING WNUFACTUREAS INSTALLATION RECO W/ENDAnpNSI IP SYSTELIO WALL SHEATHING WOW OR LT. GA METALSTUW^ .1"CH DAP RECCMMENDEDAT PANEL EDGES UNLESS OTHEMMSE PROVIDED BY 'tiy YACHOlED PROFILED EDGES ZPSOVER AL JOINTS I"ZOSYSTE OWALL VER ALL D1aPSYBTE/A0 OVFFIMTAPEA 1111" IY OF \\� 14MCH AT ALL7iJDITTg IAFWCH DAP RECOMMENDED AT. PANEL EDGES OTHEFNAEE PROVIDED D BY MACHINED PROFILED EDGES FASTEN ZIP SYSTEMS WALL. SHEATHING AS REOUBIED BY DESIGNEROF41SCORD OR LOCAL a1DDWOCWE WALL ASSEMBLY BRICK VENEER AIR SPACE (AS PRESCRIBED BY LOCAL BUILDING. CODE) •�,�j ZIP SYSTEM® WALL SHEATHING WOOD .`�\�: OR LT. GA. METAL STUDS TOP EDGE OF FLASHING TAPED WITH �•;� ZIP SYSTEM® TAPE OR ADHESIVEBACKED:FLASHING. �•`� , (MUST MEETAC148)' . .CODE APPROVED BASE FLASHING' ' WEEP HOLES (AS PRESCRI13ED BYLOCALBUILDING CODE) WALL ASCF1d8LM BRICH.YENEER AIRSPACE (AS PRESCRIBED BY LOCAL BUXMNG CODE) .ZIP SYSTEMS WALL SHEATKNO WOOOOR LT. GA.METALSTUDS 1M*ICH GAP RECOMMENDED AT PANEL EDGES UNLESS.. OTHERWISE PROVIDED BY . MACHINED PROFILED EDGES 21P SYSTEMS TAPE (I15TALlED OVER ALL VOINTS IN LP SYSTFJAS .WALL'SHEATHING} OVERLAP TAPE A 14INIMLBI OF N 1 INCH ATALLTJOINTS I1a4NCH GAP RECOMUENDFO ED BY OR LOCAL .. . Ote. Far optimal air leakage reduction, all untaped'edg'es of the panels can be caulked, gasketed or sealed with a weather stripping material. ZIP:System Sheath in9Installation Details on Walls (continued) WALL BEYOND. WALL ASSEMBLY BRICK— VENEER BACKDAM PER .WINDOW AIR SPACE (AS PRESCRIBED BY • `` i >•,; MANUFACTURER'S INSTALLATION RECOMMENDATIONS LOCAL BUILDING CODE) •'• ZIP SYSTEM® WALL SHEATHING \; •.• •., .WOOD OR LT. GA, METAL STUDS INSTALL CODE -RECOGNIZED ��. SILLIPAN FLASHING IN ROUGH TOP EDGE OFFLASHING TAPED `,\'. OPENING PRIOR TO WINDOW INSTALLATION. WITH ZIP SYSTEM TAPE OR ADHESIVE BACKED FLASHING' (MUST MEET AC148) -- CODE APPROVED FLASHING .. WEEPS (AS PRESCRIBED BY LOCAL BUILDING CODE) STEEL LINTEL INSTALL WINDOW IN ACCORDANCE WITH DETAILS 24A-24D OR.25A725D .. WALL BEYOND TOP EDGE OF FLASHING TAPED' WITH 110, P SYSTEM®TAPE OR' ADHESIVE BACKED FLASHING. (MUST MEETAC148) ----� ` WEEPS'(AS PRESCRIBED BY LOCAL BUILDING CODE) `rsz s CODE 'APPROVED FLASHING WALL ASSEMBLY BRICK VENEER AIRRSPACE (AS'PRESCRIBED,BY LOCAL BUILDING CODE) ZIP SYSTEM® WALL SHEATHING WOOD OR LT. GA. METAL STUDS WALL ASSEMBLY CODE CODEAPPRpVED CLADDING (INSTALLED IN ACCORDANCE WITH CLADDING MANUFACTURER'S INSTALLATION RECOMMENDATIONS) EXTERIOR RIGID INSULATION DRAINAGE PLANE (MIN. Y") ZIP SYSTEM@ WALL SHEATHING. WOOD OR LT. GA. METAL STUDS TOP EDGE OF FLASHING TAPED TO WALL SHEATHING WITH ZIP SYSTEM@ . TAPE OR ADHESIVE BACKED, . FLASHING. (MUST MEETAC148) = CODE APPROVED FLASHINA; FOUNDATION Note: For optimal air leakage reduction, all untaped;edges of the panels can be caullied,,gasketed. or sealed with a weatherstripping material. ,w'"Wr i^' '�.'" k- i%' e.6,.., t ,. a. i.•4A',�'i` "%.yi. 'ry w, w • .r; •': +�+i } # r+.. lk ;4 'ar, " ' 7a`" x# a`~ t to 9 k,�^' ,r � ` 0 �, i, :; T� i h �a' � f�` 'w i iJ" i`�.,. >'' � ,��" *y�,•�a�•"' y'S'`^ s Y«''�"�` � �n� 1 "b ♦ w i } +, ,_ + ♦ :. � '� r. '�.' sr i� hcaxa�2q #v � ^-/,` 1.a p"��� � �"�++ k y .. ♦ , "r, a^.:. J� � ima-ix� c �raraf .a�'rr..rfz� "" " :.'� � rc 3, �` '�`if i^ �^y x 1 i� c .�,# ,*- 1 - " „�:, �..a ar"` �, pie... FxUin � >..�• �,. €^ � `r #,' � ,.. a. �• � "fit } i'�•. .,"+ # � r { "'� + J S� �^ � "* F �aa r" 1'�`-, i* s K. "+°{4 , ;�"'.r,K.� } l,r* • r � a• � $ ;# r �"i < < !Y ,� ' 4rp� 4, .s �#�¢" ,� •�'' �4 � k.¢as �, •� �:'"� o +r # r• _.. �r �, �. 1 t ha �i �"'°i. �* ,.e x�.. a` •� �,�� � � { Y �.�,� `�e?m$,`„ e��k" �' "� '' � � � �", 9 `'7� # � � ,e '�t: r , - - "'rr 'i = - r s *^x� , r,ar -max a '�, ♦ s �`_ ' � �` � � { ♦t r . * s � *#q..`3�+ p °'et i � L � ,�"+�* `" �1 �"+�' =v s � ,��� "�. �' �� � •a'J".a�'+" ' '� �'^• «' ,R`'.�., Iry ,,* bl.. ` ¢ r4 ° a tn*k "a .t m•` E i •:n "ryr• T. r oy S� .�--7 ���T �, x `�,• *• �.i° �{r h`�' rah t� o li�,'�,;c t ,'} `"� � .�; i 7S x ,11 i Y a ix r a LL •�� tV? rr '�,ti tL�"'#� �`[ .'�"` �w+`'o: ��,s�'"A"�.ryyY 5��:. �y�' d n�A * w �.w�jk p'pq}�' 4.�'� x;'?' .,� R� .`�i^.'d A ,�M.�+Yµv «. f,4�� atc Y�.' "M._�yn j? *� r �;,. •' y°3a f 'r '*Pa.' � � tom• � "yam"}{ �'1i s,�� � w'. �R � 8 44 i. • s a. i �- y y M ,+' w� ry Y � . i �r_ �J r 4 ys § � ^e �?' � �dC' �e t` .� R �'' `�' r� ] + ;_ � �� k ;ka+s f!' � C ' � r *• �,` ,G Sx " ilR ,k,:,W r % a G r, ^ •�;``,.. `` ^« r ,+a yd ` R g +'iiyG °��w ati'r � �,y �� � of +.�•.: rr' ,: ��,c Y 4"+r. 1 ry `` s� 1`w 'Lk 4 �,. .� �.. �+} ^ rx � � yyA..� `. � � a , *. r r � �� ,`.rt` _� �,�"`'1•« s`� '6-�, � - �,#,� k w -: ��n `���y � r R. ' , ,Yr +,' #, . 4 � ',l�. r r ,:,•r«'�.y�, �' �' :i"��#r ' 9 ^+ems r °a'. y""•`•� Mt � � � '� � � < �, S„ a '•E � 'L= ,g �` �' I, f"a�• n�;` f t x�".Se'P j. ,th.4 p e�, ,� � `�"" y "E 'g'•n# z rxs 47. �` .. �,' S '„y c # � r »� ;�" `, � ' r � "�' � � • r rq d ,� vnv aA_ `'*, r, R A. Y q ,• r ", - C r ii' ~R r � it e, - ~+ 'f •.- . •"+� , E r ! - " "r ,+ -' ,�' ' • .. .� r*a` a -♦ .=`fir { � • , .K. f+rrw,.. r , , +.•ra" f wa ':9".v ,"'�" .d '4:ae"f% .�+i.�`�k.LorF` 'µ' + ' r F �• ZIP SYSTEM® SHEATHING WITH HARD COAT STUCCO AT: BLOCK FOUNDATION WALL- OPTIONA- ..H 2: TRADITIONAL HARD -COAT STUCCO. -' INSTALLED IN ACCORDANCE W" THE LATH i .:.MANUFACTURER'S OR THE PORTI.AND ' CEMENTASSC,(PCA) ' RECOMMENDATIONS VYITH THE MOST r: - =• RESTRICTIVE CONTROLLING. ONE LAYER OF WATER.RESISTIVE VAPOR -PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO GRADE D BUILDING PAPER ZIP SYSTEM® SHEATHING' , TOP EDGE OF WEEP SCREED TAPED TO WALL SHEATHING' • - WITH ZIP SYSTEM® TAPE OR :+ •: ADHESIVE BACKED FLASHING, ' (MUST MEET AAMA 711 OR AC148) - i::,� WOOD OR LT. GA. METAL STUDS ADHESIVE SACKED MEMBRANE ' "• BRIDGE FLASHING CENTERED OVER TRANSITION JOINT (ZIP' SYSTEM TAPE MAY BE USED AS e THE BRIDGE FLASHING) o 0 CODE -APPROVED :WEEP SCREED AT BASE OF WALL ... VERTICALANDHORIZONTAL CONTROL JOINTS AS NEEDED. = :' DESIGNER -OF -RECORD TO SPECIFY TYPE AND LOCATION. MASONRY BLOCK WALL 7JP SYSTEM® SHEATHING IS APPROVED TO REPLACE. ONLY THE FIRST LAYER OF A TWO- AYER UNDERLAYMENTSYSTEM.: DRAWING_NOT•TO SCALE N '����'" Sales Office:_ 70925 pavid Taylor Drive o Suite 360 : Charlotte; NC 28262 o SHEATHING 8 TAPE Telephone:.800.933.9220 - www.zipsystem,cam �Ui` �I II D ENGINEERED Woons es e construction etails are provided to assist.in a nstal allon o ZI ystem product s) and'may'not apply to every situation.. Manufacturer accepts no responsibility liability or for the use of these or other construction details. ZIP SYSTEM®SHEATHING WITH HARD COAT:ST000O AT BLOCK- FOUNDATION WALL ' OPTION A:.-.. H '2 WALL ASSEMBLY ... �. TRADITIONAL: HARD -COAT STUCCO METAL LATH ONELAYER WATER-RES. BARRIER ' ZIP SYSTEM® SHEATHING" ' W00D OR LT. GA. METAL STUDS TOP EDGE OF WEEP. SCREED TAPED TO WALL SHEATHING' WITH'ZIP.SYSTEM® TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AAMA 711 OR % AC148) CODE -APPROVED WE SCREED AT BASE OF WALL ADHESIVE BACKED'MEMBRANE BRIDGE FLASHING CENTERED OVER . 1 TRANSITION JOINT (ZIP SYSTEM.: 1 ... TAPE MAY BE USED AS THE BRIDGE FLASHING) MASONRY BLOCK WALLap ` .. ` _ .. i.AT11 — \ r . TOP EDGE OF.WEEP SCREED TAPED TO WALL SHEATHING WITH ZIP \ SYSTEMS TAPE OR ADHESIVE BACKED FLASHING.:(MUST MEET AAMA 7'I1' OR AC148) ... TRADITIONAL HARD-COAT-sTUCCO INSTALLED IN ACCORDANCE WITH THE. \ MANUFACTURER'S OR THE PORTLAND :CEMENT Assc. (PCA) RECOMMENDATIONS WITH THE MOST' .... RESTRICTIVE CONTROLLUNG. I ONE. LAYER; OF WATER -RESISTIVE , VAPOR -PERMEABLE BARRIER WITH A . . . PERFORMANCE AT. LEAST EQUIVALENT TO GRADE D BUILDING PAPER. COD&APPROVED WEEP SCREED AT BASE OF WALL ADHESIVE BACKED MEMBRANE BRIDGE FLASHING CENTERED OVER TRANSITION JOINT (ZIP SYSTEM TAPE.MAY BE USED AS THE BRIDGE FLASHING) : . MASONRY BLOCK WALL• ., . ' 'ZIP SYSTEM®SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO LAYER.UIVDERIAYMETYI`SY$11<MOT TO'SCALE Sales Office:-10925 David Taylor Drive . Suite 300 - Chadotte, NC.28262 .. Ws D ENGINEERED SHEATHING TAPE Telephone::600.'933.9220 - www.zipsystemcomU u r WOODS ese construct on etai s are provi a to assist (n the insta atlon o IP stem y proot apply to everysituation. Manufacturer accepts no responsibility or Ilabirty for the use of these or other construction details.