Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
- Project Summary Job: wrightsof® Date: Enure House By - QUICK CALCS, INC. 317 ST. LUCIE LANE, Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information For: 167 SE LUCERO DR. PORT ST. LUCIE, FL Notes: ®- • • • Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 12552 Btuh Structure 11636 Btuh Ducts 2389 Btuh Duds 3073 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14942 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 13973 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1419 Btuh Ducts 933 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) 2352 Btuh Area (ftz) 796 796 Equipment latent load Volume (it.) 6368 6368 Air changes/hour 0.61 0.32 Equipment Total Load (Sen+Lat) 16325 Btuh Equiv AVF (cfm) 65 34 Req. total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S241A AHRI ref Coil ASPT291314A AHRI ref 201786066 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating Input 4.3 kW Sensible cooling 16520 Btuh Heating output 14696 Btuh Latentcooling 7080 Btuh Temperature rise 50 OF Total cooling 23600 Btuh Actual airflow 267 cfm Actual airflow 787 cfm Air flow factor 0.018 cfm/Btuh Air flow factor 0.054 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fi•F 2022-Feb-1513:40:06 Rig k-Sute®Universal 2021 21.0.08 RSU08101 Page 1 ACCK amerts\Wrigfisoft HVAC\167 SE LUCERO DRIVE.np Calc= MJB FrortDoor faces: E -EL wrightsoft, Right-J® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LANE, Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@,AOL.COM 1 Room name Entire House BEDROOM2 2 Exposed %ell 108.0 ft 22.0 It 3 Room height 8.0 ft 8.0 It heatt000l 4 Room dimensions 1.0 x 111.0 It 5 Room area 796.0 ft' 111.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (M Load number (Btuhtft;cF) (Btuw or perimeter (ft) (Bhuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 ' 13A6 Oocs 0:258 In , :4 722 44f8 120 99 715 444 0 0 WO o 21 r, . _..oe.229 ._._ _217.. �`.... 0 I�13AB-0as �901D34 58 a 722 4A9 304 275 1987 1235 0 0 0 0 0 0 0 0, 11 !— G W". 4A5-2ow 13A6Otx 0.470 0268 '---'0A70.... e s - 1316 722 36.84 449 2,9 ; 184 0 172 382 1243772 _ 1068 _ 80 68 491 �305' :4A52ow�_._sw a. . d3.16 _'a_. 14.83 12 -178. IWf 13AB-0ocs 0.258 w 722 4.49 256 184 0 1329 948 826 2652 96 24 72 520 316 323 884 � ---G C 4A5.2ow 16638ad w _ 0470 0.026 w __... 1316 ___5t3 3684 i ...�..1,3,0. 72 798 796.._ v79 _ " 1035 111 0 1f1 _.. 81 ___ , 144: F 99A-tnl 0989 2769 0.00 796 108 2991 0 111 22 609 0 61 c) AED excursion 648 1278 Envelope IosJgain 10560 9076 2175 2113 12 a) Infiltration 1992 560 406 114 b) Room ventilation 0 0 0 0 13 Internal gains: Ooc upants @ 230 0 0 0 0 Appliances(other 2000 0 Subtotal (lines 6to 13) 12552 11636 2581 2227 Less e)temalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 167 86 14 Subtotal 12552 11636 2748 2313 15 Dud loads 19% 26% 2389 3073 19% 26% 523 611 FTTotal room load 14942 i 14708 3271 1 2924 Ajr required (clim) 267 7871 59 156 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -tFAd- wriightsoftt 2022-Feb-1513:40:07 Right -Suite® Universal2021 21.0.08 RSU08101 Page 1 ...cumenls\WrightsoftHVAC\167SELUCERODRIVE.nQ Calc=MJ8 Front Door faces: E -1-,wrightsoft, Right-M Worksheet Job: Entire House Date: Br QUICK CALCS, INC. 317 ST. LUCIE LANE, Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@f10L.COM 1 Room name BEDROOMI LIVING/KITCHEN 2 Exposed Hall 19.0 It 59.0 ft 3 Room height 8.0 It heaVcool 8.0 ft heaV000l 4 Room dimensions 10.0 x 9.0 It 1.0 x 502.0 ft 5 Room area 90.0 ft 502.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area Load number (Btuhlft-°F) (Btu or perimeter (ft) (B>uh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A6 Oocs : 0:258 n 722 449 %4 0 0 0 120 99 715 '444. ,0.3907492 Aa 2 229 ..__,_y21. W 13AB-0ocs 0258 a 722 449 80 6B 491 305 442 192 9 183 1322 118 822 332 11 W 4A5-2ow 0470 a 13.16 3664 W.A__0 12 158 S _ 0 _ .4A5r 0.4 0 . 13. 6. ,,,..14.83 .... > �U ..�_7D 0 _..0 . O . _ 0 __. _ 0 W L—G 13AB-0ocs 0256 w 722 4.49 0 0 0 0 0 160 48 112 0 809 632 503 1768 4A5-2ow 0.470 w 13.16 07.3..502 W.B4 0 0 0 502 _._...,.. 365. __,.653. F 22A tpl 0.989 27.69 0 00 90 19 526 0 502 59 1634 0 61 c) AED excursion 1 0 1363 Envelope losslgain 1761 1188 5825 5101 12 a) Infiltration 350 98 1088 306 b) Room ventilation 0 0 0 0 13 Internal gains O=pants@ 230 0 0 0 0 Appliances/other 01 2000 Subtotal (lines6to13) 2111 1286 6913 7407 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 180 87 74 39 14 Subtotal 2292 1373 6988 7446 15 Dud loads 19% 26% 436 363 190/0 26% 1330 1966 Total room load 2728 1736 8318 9412 Air required (dm) 49 93 1491 504 Calculations aDDroved bvACCAto meet all requirements of Manual J 8th Ed. -Fj.F• 2022-Feb-1513A"7 A "` ' ..- " "`""'" " Rigk-SuteO Universal 2021 21.0.08 RSU08101 Page 2 AGC,. ....rds\WrigltsoftHVAC\167SELUCERODRIVE.rLp Calc=MJ8 FrortDoorfaees: E g + wrightsoft• Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS ,AOL.COM 1 Room name HALL AHU 2 Exposed mall 4.0 ft 0 ft 3 Room height 8.0 It heaU000l 8.0 ft heat/cool 4 Room dimensions 12.0 x 4.0 It 3.0 x 3.0 ft 5 Room area 48.0 ft' 9.0 ft2 Ty Construction U-value Or HTM Area (M Load Area (its Load number (Btuh/ft-'F) (B or perimeter (ft) h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13 6 Oocs 0258 �n 722 = 449 0 0 6 0 0 0380 092 0 4 0 .m _...9 W 13AB-Oocs 0.258 a 7.22 4A9 0 0 0 0 0 0 0 0 0 0 0 11 4A5�2ow 13AB-0oC7a _4A5 2puvA _ _ 0470 0258 OA70 a s �.. s1 1316 722 13.1.6: ,_ 3684 449 1483 70 :. 32 _..A 0 32 _. D 0 231144 0 0 0 Q 0 0 ;Q _ _�', k0_ WI - L--G 13AB-Oocs 0.258 w 7.22 4A9 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2ow 0.470 :.., ,_.., Q26 w 13.16 ..0,7.. 36.84 ,130 0 : 48 0 _ 48 35 ..,.„..._ 62 noaa 97aa nnn......,,, au a ill n q n.w.._n n 61 c) AED excursion 1 -9 0 Envelope loss(gain 377 197 7 11 12 a) Infiltration 74 21 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Ooalpants@ 230 0 0 0 0 Appliances/other 0 0 Subbtal (lines6 to 13) 451 218 7 11 Less extemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution -451 -218 -7 -11 14 Sublotal 0 0 0 0 15 Dud loads 19% 26% 0 0 190/0 26% 0 0 Total room load 0 0 0 :10 Airrequired (dm) 0 0 0 Calculations aDDroved bvACCAto meet all requirements of Manual J 8th Ed. -FW wrGghtsolFt^' 2022-Feb-1513AO:07 A & Rigtt-Sute®Universal 202121.0.08RSU08101 Page ...aments\Wriglisoft HVAC1167 SE LUCERO DRIVE.nQ Calc= MJ8 Front Door faces: E + wrightsoft, Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LANE, IT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS ,AOL.COM 1 Room name BATH 2 Exposedmil 4.0 It 3 Room height 8.0 It heaV000l 4 Room dimensions 4.0 x 9.0 It 5 Room area 36.0 ftz Ty Construction U-value Or HTM Area (M Load Area Load number (Btuhlft-°q (Btu or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 -13A6 DOCs 0.258 � n i22 448 Q 0 0 0 IW 13A6-0ocs 0258 a 7.22 449 32 24 173 108 �--G 4A5-2ow 0.470 a 1316 36.84 8 0 105 295 11 'W, : 13AB Ocxs 0258 s ' 722 = 4.A9 ; 0 1-1 0 0 0 :-Cy .4f15 tow . 0.47013.16. T4.83 D �... «...._.0 W 13AB-0ocs 0258 w 7.22 449 36.84 0 0 0 0 0 0 0 0 _L—G 4A5-2ow 0.470 w 13.116 ... -µ36 w F 22A-tol 0.989 27.69 0.00 4 ill 0 61 c) AED excursion 1 16 Envelope loss(gain 416 465 12 a) Infiltration 74 21 b) Room ventilation 0 0 13 Internal gains Oocupants@ 230 0 0 Applianoes/other 0 Subtotal (lines 6 to 13) 489 486 Less extemalload 0 0 Lessiransfer 0 0 Redistribution 36 17 14 Subtotal 525 503 15 Dud loads 19% 26% 100 133 Total room load 626 1 636 Air required (dm) 11 34 Calculations aDDroved bvACCA to meet all requirements of Manual J 8th Ed. -1°f.1- wrGg"tsoft- 2022-Feb-1513:40:07 149GP. Rigtt-Sute®Universal 202121.0.08RSU08101 Page —mments\WrighsoftHVAC1167SELUCERODRIVE.nQ Calc=MJ6 Front Doorfaees: E - wrightsoft° Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM For: 167 SE LUCERO DR. PORT ST. LUCIE, FL External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest fiction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.362 in/100ft 267 cfin 138 Job: Date: By: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.362 i n/100ft 787 clin Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 636 11 34 0.493 4.0 Ox 0 VIFx 6.3 95.0 BEDROOM 1 c 1736 49 93 0.483 6.0 Ox 0 VIFx 8.5 95.0 BEDROOM2 c 2924 59 156 0.509 7.0 Ox0 VIFx 3.2 95.0 LNING/KrrCHEN c 3137 50 168 0.364 7.0 Ox 0 VIFx 22.2 115.0 st1 LIVING/KrrCHEN-A c 3137 50 168 0.362 7.0 Ox 0 VIFx 23.0 115.0 st1 LIVING/KrrCHEN-B c 3137 50 168 0.373 7.0 Ox 0 VIFx 19.0 115.0 st1 Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 PeakAVF 149 504 0.362 923 10.0 0 x 0 VInIFIX Return, Branch Detail: Table, Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox 0 61 202 0 0 0 0 Ox 0 VIFx rb1 Ox 0 99 336 0 0 0 0 Ox 0 VIFx rb4 Ox 0 107 249 0 0 0 0 Ox 0 VIFx Boldritallo values have been manually overridden * wr ghtsoft- �• pAai+N1��MmthHwrwy<omry.y Rigk-Sute®Universal 2021 21.0.08 RSU08101 ...cements\Wrightsoft HVAC\167 SE LUCERO DRIVE.np Calc= MJ8 Front Door faces: E 2022-Feb-1513:40:12 Page 1 ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FORLCQMPLIANCE REVIEWED BY 13 /11, DATE PLANS AND PERMIT MOSTE KEPT ON JOB OR NO INSPECTION WILL BE MADE. Jobe:. Performed €or 167SEL- CERO.DR, FORTsf.wm'FL FILE COPY 00C,K CALCS, INC. scaler 1 : 66 i'age1 317 M 1 CELANE Rir .Su ?llr vesai2p21 FT.PF,RCE,FL34M 2 ('MU08(01 Plane 771 ? 2MxFab 15131 2 QU0KCALCS(4A0LCONi AHVA0t167SE=ERODRVEn0