HomeMy WebLinkAboutEnergy Efficiency Codec -Qoa.o(V9 FORR405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method n r_nrnrr_n Project Name: 167 SE LUCERO DRIVE Builder Name: Street: Permit Office: FEB 2 3 2022 City, State, Zip: PORT ST. LUCIE, FL, Permit Number: Owner: Design Location: FL, Fort Pierce-,,,,,� Jurisdiction: County: St. Lucie(Florida 6t, Lucie CAbnty ZP nQ Climate oneerml 1. New construction or existingExisting (Projected) 10. Wall Types(864.0 sgft.) Insulation Area 2. Single family or multiple family " Detached a. Concrete Block - Int Insul, ExteriorR=4.1 864.002 b. N/A R= it 3. Number of units, if multiple family 1 c. N/A R= it 4. Number of Bedrooms 2 d. N/A R= it 5. Is this a worst case? No 11. Ceiling Types(796.0 sqft.) Insulation Area a. Under Attic (Vented) R=38.0 796.00 it) 6. Conditioned floor area above grade (ft2) 796 b. Conditioned floor area below grade (ft2) 0 N/A R= it 7. Windows(113.0 sqft.) Description Area 12. Ducts, location & insulation level R it a. U-Factor: Sgl, U=0.65 113.00 ft2 a. a. Sup: Attic, Ret: Attic, AH: AHU 6 125 SHGC: SHGC=0.25 b. b. U-Factor: N/A it C. SHGC: 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 23.6 SEER:16.00 SHGC: Area Weighted Average Overhang Depth: 2.000 it Area Weighted Average SHGC: 0.250 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Strip Heat 17.0 COP:1.00 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 15. Hot Water Systems 9. Floor Types Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R= 0.0 796.00 ft2 E F: 0.950 _ 2 it b. Conservation features c. N/A R= it None 16. Credits None Glass/Floor Area:0.142 Total Proposed Modified Loads: 29.96 PASS Total Baseline Loads: 32.70 I hereby certify that the plans and specifications covered by Review of the plans and STq�� this calculation are in compliance with the Florida Energy specifications covered by this �1 Code. calculation indicates compliance'`.`��' ` b&?_ab9]2Q with the Florida Energy Code. ""' PREPARED BY: Before construction is completed this building will be inspected for ir?j DATE: 2-15-2022 compliance with Section 553.908 Florida Statutes. I hereby certify that this building, as designed, is in complianceGrj�t� with the Florida Ener Co or OWNER/AGENT: _ BUILDING OFFICIAL: DATE: �i / ` Z '2 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSVRESNETACC 380, is not greater than 0.000 On for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 2/15/2022 2:55:38 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FONM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 167 SE LUCERO DRIVE Addresstype: Street Address Building Type: User Bedrooms: 2 Lot#: --- Owner: ConditionedArea: 796 Block/Sub Division: --- Total Stories: 1 PlatBook: --- BuilderName: Worst Case: No Street: Permit Office: RotateAngle: 0 County: St. Lucie Jurisdiction: Cross Ventilation: No City, State, Zip: PORT ST. LUCIE, FamilyType: Detached Whole House Fan: No FL, New/Existing: Existing (Projected) Terrain: Suburban Year Construct: Shielding: Suburban Comment: CLIMATE Design Temp Int Design Temp Heating Design Dailytemp ✓Design Location TmySite 97.5% 2.5% Winter Summer DegreeDays Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 796 6368 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _ 1 BEDROOM 2 111 888 No 0 1 Yes Yes Yes _2 BEDROOM 1 90 720 No 0 1 Yes Yes Yes _3 LIVING/KITCHEN 502 4016 Yes 0 Yes Yes Yes —4 HALL 48 384 No 0 Yes Yes Yes _5 AHU 9 72 No 0 No Yes Yes 6 BATH 36 288 No 0 Yes Yes Yes FLOORS (Total Exposed Area = 796 sq.ft.) # FloorType Space Exposed Perim PerimeterR-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins BEDROOM 2 22 0 111 ft 0.473 --- 0.00 1.00 0.00 —2 Slab -On -Grade Edge Ins BEDROOM 1 19 0 90 ft 0.473 --- 0.00 1.00 0.00 _ 3 Slab -On -Grade Edge Ins LIVING/KITCHEN 59 0 502 It 0.473 --- 0.00 1.00 0.00 4 Slab -On -Grade Edge Ins HALL 4 0 48 ft 0.473 --- 0.00 1.00 0.00 _ 5 Slab -On -Grade Edge Ins AHU 1 0 9 ft 0.473 --- 0.00 1.00 0.00 6 Slab -On -Grade Edge Ins BATH 4 0 36 ft 0.473 --- 0.00 1.00 0.00 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) —1 Hip Composition shingles 839 ft2 0 ft2 Light N 0.5 No 0.5 No 0 18.43 2/15/2022 2:55:38 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ATTIC # Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Vented 150 796 ft2 N N CEILING (Total Exposed Area = 796 sq.ft.) # CeilingType Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type _ 1 UnderAttic(Vented) BEDROOM 2 38.0 Blown 111.0ft2 0.049 0.10 Wood _2 UnderAttic(Vented) BEDROOM 1 38.0 Blown 90.0ft2 0.049 0.10 Wood _3 UnderAttic(Vented) LIVING/KITCHEN 38.0 Blown 502.0ft2 0.049 0.10 Wood _4 UnderAttic(Vented) HALL 38.0 Blown 48.0ft2 0.049 0.10 Wood _5 UnderAttic(Vented) AHU 38.0 Blown 9.0ft2 0.049 0.10 Wood 6 UnderAttic(Vented) BATH 38.0 Blown 36.0ft2 0.049 0.10 Wood WALLS (Total Exposed Area = 864 sq.ft.) Adjacent Cavity Width Height Area U- Sheath Frm. Solar Below ✓# Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade -1 S Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 10.0 0 8.0 0 80.0 0.149 0 0 0.50 0 % -2 W Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 12A 0 8.0 0 96.0 0.149 0 0 0.50 0 % -3 E Exterior Conc. Blk - Int Ins BEDROOM 1 4.1 10.0 0 8.0 0 80.0 0.149 0 0 0.50 0 % -4 S Exterior Conc. Blk - Int Ins BEDROOM 1 4.1 9.0 0 8.0 0 72.0 0.149 0 0 0.50 0 % _5 N Exterior Conc. Blk - Int Ins LIVING/KITCHEN 4.1 15.0 0 8.0 0 120.0 0.149 0 0 0.50 0 % _ 6 E Exterior Conc. Blk - Int Ins LIVING/KITCHEN 4.1 24.0 0 8.0 0 192.0 0.149 0 0 0.50 0 % _ 7 W Exterior Conc. Blk - Int Ins LIVING/KITCHEN 4.1 20.0 0 8.0 0 160.0 0.149 0 0 0.50 0 % _ 8 S Exterior Conc. Blk - Int Ins HALL 4.1 4.0 0 8.0 0 32.0 0.149 0 0 0.50 0 % 9 E Exterior Conc. Blk - Int Ins BATH 4.1 4.0 0 8.0 0 32.0 0.149 0 0 0.50 0 % DOORS (Total Exposed Area = 20 sq.ft.) Width Height V# Ornt Adjacent To DoorType Space Storms U-Value Ft In Ft In Area 1 N Insulated LIVING/KITCHEN None 0.39 3.00 0 6.00 8 20.0ft2 WINDOWS (Total Exposed Area = 113 sq.ft.) Wall ----- Overhang ----- ✓# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation InteriorShade Screening _ 1 S 1 Metal Low-ESingle Yes 0.65 0.25 Y N 12.0ft2 2.0 ft 0 in 1.0 ft 4 in None None -2 W 2 Metal Low-E Single Yes 0.65 0.25 Y N 24.0ft2 2.0 ft 0 in 1.0 ft 4 in None None -3 E 3 Metal Low-ESingle Yes 0.65 0.25 Y N 12.0ft2 2.0 ft 0 in 1.0 ft 4 in None None -4 E 6 Metal Low-E Single Yes 0.65 0.25 Y N 9.0ft2 2.0 ft 0 in 1.0 ft 4 in None None _ 5 W 7 Metal Low-E Single Yes 0.65 0.25 Y N 48.0ft2 2.0 ft 0 in 1.0 ft 4 in None None 6 E 9 Metal Low-ESingle Yes 0.65 0.25 Y N 8.0ft2 2.0 ft 0 in 1.0 ft 4 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) _1 Wholehouse ProposedACH(50) 0.00025 531 29.11 54.66 0.0902 5.0 All 2/15/2022 2:55:38 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS # Mass Type Area Thickness Furniture Fraction Space _ 1 Default(8lbs/sq.ft.) 0 ft2 O ft 0.30 BEDROOM 2 —2 Default(8lbs/sq.ft.) 0 ft2 O ft 0.30 BEDROOM 1 _ 3 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 LIVING/KITCHEN 4 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 HALL _ 5 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 AHU 6 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 BATH HEATING SYSTEM # System Type Subtype AHRI # Efficiency Capacity----GeothermalHeatPump---- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Strip Heat None COP: 1.00 17.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit Split/Single SEER:16.0 23.6 0 0.70 sys#1 1 HOT WATER SYSTEM # SystemType Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipelength 1 Electric None AHU 0.95 (0.93) 50.00 gal 61 gal 120 deg Standard None 66 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff ` 1 No NA NA NA No NA NA NA None DUCTS VDuct ---------Supply--------- --------- Return-=-- -- # Location R-Value Area Location R-Value Area LeakageType Air Handler CFM 25 CFM 25 HVAC # TOT OUT QN RLF Heat Cool 1 Attic 6.0 125 ft2 Attic 6.0 15 ft2 DefaultLeakage AHU (Default) (Default) 1 1 TEMPERATURES Program able Thermostat: N Ceiling Fans: N Cooling I] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [I Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference ScheduleType 1 2 Hours 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 _ Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 2/15/2022 2:55:38 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES(Continued) _ Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 2/15/2022 2:55:38 PM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 167 SE LUCERO DRIVE Builder Name: Street: Permit Office: City, State, Zip: PORT ST. LUCIE, FL, Permit Number: Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General Acontinuous airbarriershall beinstalled in the building envelope. Air -permeable insulation shall requirements The exteriorthermal envelope contains acontinuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exteriorthermal envelope insulation forframed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation andcantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrowcavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatlyto fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall onexteriorwall and tubs shall separate them from the showers and tubs. beinsulated. Electrical/phonebox The air barrier shall be installed behind electrical or onexteriorwalls communication boxes or air -sealed boxes shall beinstalled. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering orceiling penetrated bythe boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended bythe manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 2/15/2022 2:55:38 PM EnergyGauge@ USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1