HomeMy WebLinkAbout21-145B Ocean Harbor South - Rep 3 - 03.08.22M L Engineering Inc. Consulting Engineers Threshold Inspector 2030 37th Avenue Vero Beach, Florida 32960 Phone: (772) 569-1257 Fax: (772) 569-4041 www.mlengineeringinc.com Project No. 21-145B Report No. 3 Client: Building Official: Contractor: File Mr. Gene Ross- Elliott Merrill SLC Building Department Mr. Bob Stark-Structure-Con Mr. Khris McConnell-Structure Con Page 1 of 3 OCEAN HARBOR SOUTH CONDOMINIUMS 4200 NORTH HWY A1A – SOUTH BLDG – BLDG. B THRESHOLD INSPECTION REPORT SLC BUILDING PERMIT NUMBER: 2106-0288 PROJECT NAME: Ocean Harbor South – Bldg. B DATE: March 8, 2022 CLIENT: Elliott Merrill Community Mgmt. LOCATION: Ft. Pierce, FL CONTRACTOR: Structure-Con PROJECT MGR: Khris McConnell INSPECTED BY: Todd Rhoten WEATHER: Sunny WORK INSPECTED: Units 409 & 609 – Demo & pre-pour. OBSERVATIONS: Post shores are in place from the ground floor up to the bottom of the sixth-floor slab. Unit 409 • The north balcony edge has been removed and (6) uniform post tension (PT) cables were located. • The (2) #4 bursting bars behind the PT cable anchors are corroded. • The west balcony edge was sounded and the concrete is in serviceable condition. • Remnants of the original railing posts were left in the slab when the railings were cut off and replaced with surface mounted railings several years ago. Unit 609 • A new PT cable section has been spliced to the broken uniform cable. • Anchor plates have been placed at the balcony edge and the edge repair was poured. • Remnants of the original railing posts were left in the slab when the railings were cut off and replaced with surface mounted railings several years ago. RECOMMENDATIONS: Unit 409 • All railing post remnants to be removed at the balcony edge. • Lock off (6) PT cables to replace the corroded bursting bars along the north balcony edge. Unit 609 • All railing post remnants to be removed at the balcony edge. • Re-stress the PT cable and provide a new sleeve. • Provide (2) new #5 dowels under the sliding glass door track and epoxy 6” into the existing column, parallel to the door. • The existing PT cable sleeves running in the east to west direction require repair. • Power tool clean and coat all exposed reinforcing bars prior to new concrete placement. ______________________________ _________________________________ Michael Lue, P.E. Todd Rhoten M L Engineering Inc. Consulting Engineers Threshold Inspector 2030 37th Avenue Vero Beach, Florida 32960 Phone: (772) 569-1257 Fax: (772) 569-4041 www.mlengineeringinc.com Project No. 21-145B Report No. 3 Client: Building Official: Contractor: File Mr. Gene Ross- Elliott Merrill SLC Building Department Mr. Bob Stark-Structure-Con Mr. Khris McConnell-Structure Con Page 2 of 3 Pic 1 – 09 stack North elevation Pic 2 – Unit 409 Corroded bursting bars along the north edge of the balcony. Pic 3 – Unit 409 Corroded PT cable anchor. M L Engineering Inc. Consulting Engineers Threshold Inspector 2030 37th Avenue Vero Beach, Florida 32960 Phone: (772) 569-1257 Fax: (772) 569-4041 www.mlengineeringinc.com Project No. 21-145B Report No. 3 Client: Building Official: Contractor: File Mr. Gene Ross- Elliott Merrill SLC Building Department Mr. Bob Stark-Structure-Con Mr. Khris McConnell-Structure Con Page 3 of 3 Pic 4 – Unit 609 New PT cable splice coupler. Pic 5 – Unit 609 Edge repair at new PT cable end.