HomeMy WebLinkAboutFloor PlanSt.
DUCT LABEL EXPLANATION EXHAUST FAN— EF1— PANASONIC M# FV-0510VS1
OOX,f
50/80/100CFM SLECTIONS
\ROUND DUCT
Ground Level Floor Plan
Scale: 1/4- = 1'--0"
Climatic & Geographic Design Criteria
Weathering: Negligible Termite Area: Very Heavy
Flame Spread Index & Smoke Developed Index
Insulation Flame Spread: Not to exceed 25
Insulation Smoke Developed Index. Not to exceed 45D
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 20D
Building Data
Occupancy Type: Group R
Construction Type: V
Number of Stories: Two
Prcject Area: 3012 s.f.
Building Code
7th Ed. (2020) Florida Building Code:
Residential
2017 Ed. National Electric Code
ASCE 7-16
Area Tabulation
1st Living:
1461
2nd Living:
673
Total Living:
2134
Garage:
622
Porch:
218
Entry:
38
Total: 3012
Total Gubic Volume: xxxx
Second Level Floor Plan
Scale: 1/4-= 1'-0"
Prcject Data
Prcject Name: Myers residence
Street Address: 2116 Keen Rd.
City: Ft. Pierce
County: St. Lucie
State: Florida
Scope of Work
New two level CBS single family
residence
Design Loads
Roof Live Load: 20.0 p.s.f.
Floor Live Load: 40.0 p.s.f.
Wind Speed: 150 MPH
Wind Importance Factor: 1.0
Building Category: It
Wind Exposure: B
Internal Pressure CcefFicent: .13
Structure Designed: Enclosed
Soil bearing capacity: 2000 p.s.f.
U