Loading...
HomeMy WebLinkAboutFloor PlanSt. DUCT LABEL EXPLANATION EXHAUST FAN— EF1— PANASONIC M# FV-0510VS1 OOX,f 50/80/100CFM SLECTIONS \ROUND DUCT Ground Level Floor Plan Scale: 1/4- = 1'--0" Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Flame Spread Index & Smoke Developed Index Insulation Flame Spread: Not to exceed 25 Insulation Smoke Developed Index. Not to exceed 45D Wall Finishes: Not greater than 200 Ceiling Finishes: Not greater than 20D Building Data Occupancy Type: Group R Construction Type: V Number of Stories: Two Prcject Area: 3012 s.f. Building Code 7th Ed. (2020) Florida Building Code: Residential 2017 Ed. National Electric Code ASCE 7-16 Area Tabulation 1st Living: 1461 2nd Living: 673 Total Living: 2134 Garage: 622 Porch: 218 Entry: 38 Total: 3012 Total Gubic Volume: xxxx Second Level Floor Plan Scale: 1/4-= 1'-0" Prcject Data Prcject Name: Myers residence Street Address: 2116 Keen Rd. City: Ft. Pierce County: St. Lucie State: Florida Scope of Work New two level CBS single family residence Design Loads Roof Live Load: 20.0 p.s.f. Floor Live Load: 40.0 p.s.f. Wind Speed: 150 MPH Wind Importance Factor: 1.0 Building Category: It Wind Exposure: B Internal Pressure CcefFicent: .13 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. U Q. D 0 ci 000 C" L w � z J LL cs� r v T U) w n 03 r_ d J L 4 r U Jcn LO C' N w CD > tr Id - di a.ewn si Ch66%e0 s� date fi117121 eca1e es anted Joh ��mha� 21ala Aheet A-1