HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Prmance Method
eo
CEIVED
Project Name: MYERS RESIDENCE
Builder Name: JA N
12 2022
Street: 2115 KEEN ROAD
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number: St. Lucie County
Owner: DONNIE AND JESSICA MYERS
Jurisdiction: ST LUCIE COUNTY Permitting
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Types(3200.7 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Frame - Wood, Exterior
R=19.0 2914.70 ft2
b. Frame - Wood, Adjacent
R=11.0 286.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
5. Is this a worst case?
No
11. Ceiling Types (2134.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2134.00 ft2
6. Conditioned floor area above grade (ft2)
2134
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
7. Windows(227.0 sqft.) Description
Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ft2
6 200
a. U-Factor: Sgl, U=0.65
227.00 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A
ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
46.0 SEER:20.00
c. U-Factor: N/A
ft2
SHGC:
Area Weighted Average Overhang Depth:
5.278 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.250
a. Electric Strip Heat
34.0 COP:1.00
8. Skylights
Area
c. U-Factor:(AVG) N/A
ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (2134.0 sqft.)
Insulation Area
EF:0.980
a. Slab -On -Grade Edge Insulation
R=0.0 1461.00 ft2
b. Conservation features
b. Raised Floor
R=0.0 673.00 ft2
None
c. N/A
R= ft2
16. Credits
None
Glass/Floor Area: 0.106
Total Proposed Modified Loads: 63.47
PASS
Total Baseline Loads: 74.30
I hereby certify that the plans and specifications covered by
Review of the plans and
g'CKE SrA
-
this calculation are in compliance with the Florida Energy
specifications covered by this
.y� __
Code.
calculation indicates compliance
with the Florida Energy Code.
av mnr�''� '•\�� a
PREPARED BY:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
* °
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
GAD
with the Florida Energy Code.
WE'1¢�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
6/22/2021 11:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 7
• FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
MYERS RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2134
Lot #
Owner Name:
DONNIE AND JESSICA MYE
Total Stories:
2
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
2115 KEEN ROAD
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Detached
FL ,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2134
24368.5
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
GAME RM
90
900 No
0
1
Yes
Yes
Yes
2
POWDER RM
21
210 No
0
1
Yes
Yes
Yes
3
A/C CHASE
6
60 No
0
1
No
Yes
Yes
4
M BATH
113
1130 No
0
1
Yes
Yes
Yes
5
M TOILET
15
150 No
0
1
Yes
Yes
Yes
6
M WIC
47
470 No
0
1
Yes
Yes
Yes
7
MASTER BEDR00
182
1820 No
0
1
1
Yes
Yes
Yes
8
LOFT
115
1150 No
0
1
Yes
Yes
Yes
9
STAIRS UP
84
840 No
0
1
Yes
Yes
Yes
10
DINING RM
110
1100 No
0
1
Yes
Yes
Yes
11
KITCHEN
226
2260 Yes
0
1
Yes
Yes
Yes
12
GREAT RM
346
6816.2 No
0
1
Yes
Yes
Yes
13
FOYER
99
1950.3 No
0
1
Yes
Yes
Yes
14
STORAGE
36
360 No
0
1
Yes
Yes
Yes
15
LAUNDRY RM
48
384 No
0
1
No
Yes
Yes
16
ENTRY HALL
98
784 No
0
1
No
Yes
Yes
17
BATH 2
50
400 No
0
1
No
Yes
Yes
18
BATH 3
50
400 No
0
1
No
Yes
Yes
19
HALLWAY
70
560 No
0
1
Yes
Yes
Yes
20
BEDROOM 2
144
1152 No
0
1
1
Yes
Yes
Yes
21
CLST 2
24
192 No
0
1
Yes
Yes
Yes
22
CLST 3
16
128 No
0
1
Yes
Yes
Yes
6/22/2021 11:48 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
23 BEDROOM 3
144 1152
No 0
1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Raised Floor
GAME RM
---- ----
90 ft2
0
1
0
0
2 Raised Floor
POWDER RM
---- ----
21 ft2
0
1
0
0
3 Raised Floor
A/C CHASE
---- ----
6 ft2
0
1
0
0
4 Raised Floor
M BATH
---- ----
113 ft2
0
1
0
0
5 Raised Floor
M TOILET
---- ----
15 ft2
0
1
0
0
6 Raised Floor
M WIC
---- ----
47 ft2
0
1
0
0
7 Raised Floor
MASTER BEDRO
---- ----
182 ft2
0
1
0
0
8 Raised Floor
LOFT
---- ----
115 ft2
0
1
0
0
9 Raised Floor
STAIRS UP
---- ----
84 ft2
0
1
0
0
10SIab-On-Grade Edge Insulation
DINING RM
21 It
110 ft2
----
1
0
0
11SIab-On-Grade Edge Insulation
KITCHEN
34 ft
226 ft2
----
1
0
0
12SIab-On-Grade Edge Insulation
GREAT RM
17 ft
346 ft2
----
1
0
0
13SIab-On-Grade Edge Insulation
FOYER
17 ft
99 ft2
----
1
0
0
14SIab-On-Grade Edge Insulation
STORAGE
4 ft
36 ft2
----
1
0
0
15SIab-On-Grade Edge Insulation
LAUNDRY RM
1 ft
48 ft2
----
1
0
0
16SIab-On-Grade Edge Insulation
ENTRY HALL
1 ft
98 ft2
----
1
0
0
17SIab-On-Grade Edge Insulation
BATH 2
1 ft
50 ft2
----
1
0
0
18SIab-On-Grade Edge Insulation
BATH 3
1 ft
50 ft2
----
1
0
0
19SIab-On-Grade Edge Insulation
HALLWAY
loft
70 ft2
__--
1
0
0
20SIab-On-Grade Edge Insulation
BEDROOM 2
12 ft
144 ft2
----
1
0
0
21SIab-On-Grade Edge Insulation
CLST 2
3 ft
24 ft2
----
1
0
0
22SIab-On-Grade Edge Insulation
CLST 3
2 ft
16 ft2
----
1
0
0
23SIab-On-Grade Edge Insulation
BEDROOM 3
35 ft
144 ft2
----
1
0
0
6/22/2021 11:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip
Metal 2249 ft2
0 ft2
Light
N
0.3
No 0.9
No 0
18.43
ATTIC
V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Vented
150
2134 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented)
GAME RM
30
Blown
90 ft2
0.1
Wood
2
Under Attic (Vented)
POWDER RM
30
Blown
21 ft2
0.1
Wood
3
Under Attic (Vented)
A/C CHASE
30
Blown
6 ft2
0.1
Wood
4
Under Attic (Vented)
M BATH
30
Blown
113 ft2
0.1
Wood
5
Under Attic (Vented)
M TOILET
30
Blown
15 ft2
0.1
Wood
6
Under Attic (Vented)
M WIC
30
Blown
47 ft2
0.1
Wood
7
Under Attic (Vented)
MASTER BEDRO 30
Blown
182 ft2
0.1
Wood
8
Under Attic (Vented)
LOFT
30
Blown
115 ft2
0.1
Wood
9
Under Attic (Vented)
STAIRS UP
30
Blown
84 ft2
0.1
Wood
10
Under Attic (Vented)
DINING RM
30
Blown
110 ft2
0.1
Wood
11
Under Attic (Vented)
KITCHEN
30
Blown
226 ft2
0.1
Wood
12
Under Attic (Vented)
GREAT RM
30
Blown
346 ft2
0.1
Wood
13
Under Attic (Vented)
FOYER
30
Blown
99 ft2
0.1
Wood
14
Under Attic (Vented)
STORAGE
30
Blown
36 ft2
0.1
Wood
15
Under Attic (Vented)
LAUNDRY RM
30
Blown
48 ft2
0.1
Wood
16
Under Attic (Vented)
ENTRY HALL
30
Blown
98 ft2
0.1
Wood
17
Under Attic (Vented)
BATH 2
30
Blown
50 ft2
0.1
Wood
-
18
Under Attic (Vented)
BATH 3
30
Blown
50 ft2
0.1
Wood
19
Under Attic (Vented)
HALLWAY
30
Blown
70 ft2
0.1
Wood
20
Under Attic (Vented)
BEDROOM 2
. 30
Blown
144 ft2
0.1
Wood
21
Under Attic (Vented)
CLST 2
30
Blown
24 ft2
0.1
Wood
22
Under Attic (Vented)
CLST 3
30
Blown
16 ft2
0.1
Wood
23
Under Attic (Vented)
BEDROOM 3
30
Blown
144 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
1
E
Exterior Frame - Wood
GAME RM
19 10
0 10
0
100.0 ft2
0
0.1
0.3
0
2
E
Exterior Frame - Wood
POWDER R
19 3
0 10
0
30.0 ft2
0
0.1
0.3
0
3
S
Exterior Frame - Wood
POWDER R
19 3
0 10
0
30.0 ft2
0
0.1
0.3
0
4
E
Exterior Frame - Wood
M BATH
19 8
0 10
0
80.0 ft2
0
0.1
0.3
0
5
S
Exterior Frame - Wood
M BATH
19 10
0 10
0
100.0 ft2
0
0.1
. 0.3
0
6
S
Exterior Frame - Wood
M TOILET
19 3
0 10
0
30.0 ft2
0
0.1
0.3
0
6/22/2021 11:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
o
7
S
Exterior
Frame - Wood
M WIC
19
11
0
10
0
110.0 ft2
0
0.1
0.3
0
8
W
Exterior
Frame - Wood
MWIC
19
5
0
10
0
50.0ft2
0
0.1
0.3
0
9
W
Exterior
Frame - Wood
MASTER BE
19
14
0
10
0
140.0 ft2
0
0.1
0.3
0
10
N
Exterior
Frame - Wood
LOFT
19
18
0
10
0
180.0 ft2
0
0.1
0.3
0
11
W
Exterior
Frame - Wood
LOFT
19
5
0
10
0
50.0 ft2
0
0.1
0.3
0
12
N
Exterior
Frame - Wood
STAIRS UP
19
12
0
10
0
120.0 ft2
0
0.1
0.3
0
_ 13
E
Exterior
Frame - Wood
STAIRS UP
19
7
0
10
0
70.0 ft2
0
0.1
0.3
0
14
S
Exterior
Frame- Wood
STAIRS UP
19
3
0
10
0
30.0 ft2
0
0.1
0.3
0
15
W
Exterior
Frame - Wood
STAIRS UP
19
4
0
10
0
40.0 ft2
0
0.1
0.3
0
16
N
Exterior
Frame- Wood
DINING RM
19
10
0
10,
0
100.0 ft2
0
0.1
0.3
0
17
E
Exterior
Frame - Wood
DINING RM
19
11
0
10
0
110.0 ft2
0
0.1
0.3
0
18
N
Exterior
Frame - Wood
KITCHEN
19
17
0
10
0
170.0 ft2
0
0.1
0.3
0
19
E
Exterior
Frame - Wood
KITCHEN
19
3
0
10
0
30.0 ft2
0
0.1
0.3
0
20
W
Exterior
Frame - Wood
KITCHEN
19
14
0
10
0
140.0 ft2
0
0.1
0.3
0
21
W
Exterior
Frame - Wood
GREAT RM
19
17
0
19
8
334.3 ft2
0
0.1
0.3
0
22
N
Exterior
Frame - Wood
FOYER
19
6
0
19
8
118.0 ft2
0
0.1
0.3
0
23
E
Exterior
Frame - Wood
FOYER
19
9
0
19
8
177.0 ft2
0
0.1
0.3
0
24
S
Exterior
Frame - Wood
FOYER
19
2
0
19
8
39.3 ft2
0
0.1
0.3
0
25
E
Exterior
Frame - Wood
STORAGE
19
4
0
10
0
40.0 ft2
0
0.1
0.3
0
26
S
Garage
Frame - Wood
STORAGE
11
3
0
10
0
30.0 ft2
0
0.1
0.3
0
27
E
Garage
Frame - Wood
LAUNDRY R
11
8
0
8
0
64.0 ft2
0
0.1
0.3
0
28
S
Garage
Frame - Wood
LAUNDRY R
11
6
0
8
0
48.0 ft2
0
0.1
0.3
0
29
E
Garage
Frame - Wood
ENTRY HALL
11
2
0
8
0
16.0 ft2
0
0.1
0.3
0
30
S
Garage
Frame - Wood
ENTRY HALL
11
4
0
8
0
32.0 ft2
0
0.1
0.3
0
31
W
Exterior
Frame - Wood
HALLWAY
19
10
0
8
0
80.0 ft2
0
0.1
0.3
0
32
S
Exterior
Frame - Wood
BEDROOM 2
19
12
0
8
0
96.0 ft2
0
0.1
0.3
0
33
E
Garage
Frame - Wood
BEDROOM 2
11
12
0
8
0
96.0 ft2
0
0.1
0.3
0
34
S
Exterior
Frame - Wood
CLST 2
19
3
0
8
0
24.0 ft2
0
0.1
0.3
0
35
S
Exterior
Frame - Wood
CLST 3
19
2
0
8
0
16.0 ft2
0
0.1
0.3
0
36
N
Exterior
Frame - Wood
BEDROOM 3
19
11
0
8
0
88.0 ft2
0
0.1
0.3
0
37
S
Exterior
Frame - Wood
BEDROOM 3
19
12
0
8
0
96.0 ft2
0
0.1
0.3
0
38
W
Exterior
Frame - Wood
BEDROOM 3
19
12
0
8
0
96.0 ft2
0
0.1
0.3
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated
ENTRY HALL
None
.23
3
6
18 ft2
6/22/2021 11:48 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
#
Wall
Ornt ID Frame
Panes
NFRC
U-Factor SHGC Imp Area
Overhang
Depth Separation
Int Shade
Screening
1
2
3
4
5
6
7
8
9
10
11
E 1 Metal
S 5 Metal
W 9 Metal
E 13 Metal
E 17 Metal
N 18 Metal
W 21 Metal
E 23 Metal
E 23 Metal
S 32 , Metal
N 36 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.65 0.25 Y 15.0 ft2
0.65 0.25 Y 16.0 ft2
0.65 0.25 Y 15.0 ft2
0.65 0.25 Y 15.0 ft2
0.65 0.25 Y 20.0 ft2
0.65 0.25 Y 24.0 ft2
0.65 0.25 Y 48.0 ft2
0.65 0.25 Y 20.0 ft2
0.65 0.25 Y 24.0 ft2
0.65 0.25 Y 15.0 ft2
0.65 0.25 Y 15.0 ft2
2 ft 0 in
2 ft 0 in
2 ft 0 in
2 ft 0 in
2 ft 0 in
2 ft 0 in
12 ft 0 in
8 ft 0 in
8 ft 0 in
2 ft 0 in
2 ft 0 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
704 ft2
704 ft2
35 ft 8 ft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000363
2030.7 111.41 209.16
.1373
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1 34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 20 46 kBtu/hr 1380 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type
SubTpe
Location
EF Cap Use
SetPnt
Conservation
1
Electric
None
Garage
0.98 50 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
6/22/2021 11:48 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
DUCTS
---- Supply
----
---- Return ---
Air
CFM 25
CFM25
HVAC #
v # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6
200 ft2
Attic
20 ft2
Default Leakage
Garage
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat:
N
Ceiling Fans:
Cooling Jan
Feb
Mar
A r
Ma
Jun
Jul
X Aug
X Se
Oct
Nov
Dec
��Xj Feb
Heatingg Jan�Xj
H
Mar f
Apr
I
May
Jun
rj
Jul
ri
AugSep
I
Oct
JX�
Nov
Dec
Ventin Jan
Feb
Mar [X
Apr
May
Jun
Jul
Aug
Se
Oct Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
6B
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
GAME RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
POWDER RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
A/C CHASE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LOFT
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STAIRS UP
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STORAGE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY RM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
ENTRY HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
6/22/2021 11:48 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MYERS RESIDENCE Builder Name:
Street: 2115 KEEN ROAD Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Y
U
Owner: DONNIE AND JESSICA MYERS Jurisdiction: ST LUCIE COUNTY
W
Design Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and anygaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal
envelope shall be sealed to the sub -floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/22/2021 11:48 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1