Loading...
HomeMy WebLinkAboutBUILDING PERMIT APPLICATION ALL APPLICABLE INFO MUST BE COMPLETED FOg APPLICATION TO BE ACCEPTED Date: 1� � Permit Number: RECEIVED Building Permit Application MAR 0 7 2022 Planning and Development Services St.Lucie County Building and Code Regulation Division Permitting 2300 Virginia Avenue,Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential X PERMIT APPLICATION FOR: Dock/Seawall PROPOSED IMPROVEMEn 'ATIQN Address: 1221 NETTLES BLVD Legal Description: NETTLES ISLAND INC, A CONDO.-SECTION II PARCEL 1221 Property Tax ID#: 4502-501-1408-000-8 Lot No. 1221 Site Plan Name: Block No. Project Name: BUSTTER DOCK Setbacks Front Back: Right Side: Left Side: DEt`AILED ,CONSTRUCT A 160 SQ FT DOCK WITH (1) BOAT LIFT �h n CON r 7RUC7ifONINFORMATION s; Addition a wor to' e oe orme it under t is perm —c ec a t=apply: 1IHVAC Gas Tank ❑Gas Piping Shutters OWindows/Doors 0 Electric 0 [:] _Plumbing Sprinklers Generator Roof Roof pitch Total Sq. Ft-of Construction 160 S . Ft.of First Floor: Cost of Construction: s i Z 06 Utilities:llSewer Septic Building Height: 4WN R/i.ESSEE5 h� a T- T., r Name JOHANNA BUSTTER Name: OTI$LEONARD Address: 1221 NETTLES BLVD Company: OTIS LEONARDS DOCKS&ACCESSORIES City: 'JENSEN BEACH State: FL Address: 1608 APACHE AVE ZipCoder 34957 Fax: STUART �City` State: FL Phone No. 954-592-4287 Zip Code: 34994 Fax: -°E-Mail• jbustter@yahoo.com Phone No. 772-263-2764 Fill in fee simple Title Holder on next page(if different E-Mail: LEONARDSTR(PAOL.COM fi from the Owner listed above) State or County License: 1[:alue of construction is$2500 or more,aRECORDED Notice of Commencement is required. SUP'P1.EMENTAL CONSTRUCTfN LtN lAW'If1� ORii�l4TIQN:� E .>. ,4r DESIGNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: _Not Applicable Name: PAUL WELCH. INC Name: Address: 1984 BILTMORE DR#114 Address: City: PORT ST LUCIE State: FL City: State: Zip: 34982 Phone 2-785-9888 Zip: Phone: FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: _Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such structure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit,I do hereby agree that I will,in all respects,perform the work in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review:room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use WARNING TO OWNER:Your failure to Record'a Notice of Commencement may result in your paying twice for improvements to your property.A Notice of,Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing; consult with lender or an attorney efore commencing work or recording our Notice of Commencement Signature of Owne Cont as en or wner Signature of Contractor/License Holder I-- 2�0 STATE OF COUNTY FLORIDA a STATE OF FLORIDA COUNTY OF f% Y- y l The forgoing instrument was acknowledged before me The for oing instr ment was acknowledged before me this_ieday of ,)(A i3 W ,20 ZJ by this ��ay of `N O/f ggbF_r ,20 21 by 0(1 o nNw rJu 0+e'( C l 1 c, LcU n O-✓q ame of person making statement Name of erson making statement Personally Known OR Produced Identificatiop Personally Known V2 OR Produced Identification Type of Identification ,�"` °Y Type of Identification Produced rt, Q'r LiC(/n'Sk-J o� � Produced \`x���111111111111�j���i 50, 17.?pd;•• 9 (SlgiWture of Notary Public-State of Florida) , _ Signatu a of Notary Public St to ol�lor9& Commission No. L'!Z (Seal) 3 �a Commission No. ,� a .� c:4 ii20 .��ndeb��® igl CcSZA����`� MillN REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev.8/2/17 i 1 w�y � f S`9'LQ Nettles Island Inc., A Condominium f t 98ot South Ocean Drive,Jensen Beach, PI.34957 (772) 229-2930 Fax: (772)229-9901 i FL0R1�4' Email: NIBoardPcomcast.net www.Nettle§IslandCondo.com i i September 151h,2021 Johanna Bustter 1071 Hamlin Terrace APPROVED 'Davie,FL 33325 JBUSTTERRYAHOO.COM 4 RE: Lot 1221 —Dock and Boat Lift Dear Ms.Busster, i The Association approves of your plans to install a dock and boatlift on the water within the rear property pins of Lot 1221,as indicated on the documents submitted with this request.Please be advised of the following j Nettles Island Rules and Regulations: i i Article 9.1, "Rescue ladders will be required on all dock construction for safety." t i Article 10.1(a), "Nothing may be affixed, attached, over, or bear weight, in any way, on the seawall and cap, except conduits for water and electric may extend over the seawall to a Unit Owner's dock or boat lift and must not be affixed to the seawall or cap." Please review and adhere to all N.I.waterfront property usage rules and regulations and present copies of all i applicable county permits to the condo office prior to construction. Any further modifications must be submitted to condo office for approval.Also,please be advised that all Architectural approvals issued by { Nettles Island are valid for six(6)months.If additional time is needed,owners must submit supporting documentation to request an additional six(6)months. Respectfully, Chuck Rutherford or Tom Fitzgerald Nettles Island Board of Directors I Cc: Kelly Warden,Mgr.,File CR/TF/ko r i Please be advised that Architectural Conintittee assumes no responsibility for the strirchiral adequacy,capacity or safety features of the proposed construction,alteration or addition,or forpeiforniance,workmanship or quality of ivork of any contractor or of the completed alteration or description and shall not be relied upon as an approval or warranty regarding engineering and structural design, building or zoning code compliance,feasibility or mat ketability for any pui pose,or compliance with applicable building ordinances,standards,ds,or regulations. By approving the plans and specifications,neither the Architectural Conintillee or the members thereof, the Association, the Board,its employees and representatives assinnes any liability or responsibility therefore, or for any defect in,any structure constructed there from,and said persons fiuYher specifically exchide from such approval any implied warranty of nierchantability and fitness for arry pen pose. 1 I i t 1 � _ { ' r- I 1 kVell�eS`B�vd� SS !r?rt? �c�� ���ic jens.eii Beachs FL 34957 ® m a m \� 0 0 15 e L � J, x 4, � � I f � i i. `.. PAUt-WELCH INC. i[tir_ 1 MECH-ELECT-CIVILENG. 1984 BILTMORE ST. #114 PORT SAINT LUCIL, FL 34984 PAUL WELCH R.E. FLA REG NO.29945 1"= 5' BUSTTER r j f-��- Jerner&Associates, Inc. 5 ET 1 r — Marine&Environmental Consulting Date:911121 1221 NETTLES BLVD _� 2537SEAlfonsoAve. FortSt.Lucie,FL34952 Ph.(772)283-2950 JENSEN BEACH : JERNER@BELLSOUTH.NET OCT 0 7 2021 z 0 z x �.1 t " p PROVEC'T SITES 1Y i a , n BUSTTER Jerner&Associates,Inc. Sh ET z `— —� Marine&Environmental Consulting Date:911121 1221 NETTLES BLVD -�# l ?E J 2537SE Alfonso Ave. Por-tSt.Lucie,FL34952 l � Ph.(772)283-2950 JENSEN BEACH ERNER@BELLSOUTH.NET 0 C T 0'T2021 NORTH i NETTLES ISLAND INC,A CONDO-SECTION II PARCEL 1221 �i• i EXISTING STEEL SHEET iQ PILE W DECKED CAP Q' NO ELECTRIC/WATER/STRUCTURE 34.64'5HORELINE 16.5'x 1' VERWATER i ATTACHMENTS TO SEAWALL CAP i --� CONCRETESEA WALL CAP I SEEN I Iju ......................................r j�`,ffc:-� N. ! o! `` , 1 2Q VESSEL �. TURBIDITY 10'X II'MARGINAL PIER=110 SQ FT CURTAIN 2'X 17MARGINAL PIER=34 SQ FT BARREN SANDY CANAL BOTTOM WITH 16.5'X1'OVERWATER DECK CAP= 16.5' OYSTER&SHELL FRAGMENT. SAVSURVEY TOTAL DOCKAREA =160.SSQ FT PERFORMED WITHIN 50'RADIUS OF PROJECT MANMADE CANAL SITE ON AUGUST 31,2021 BY BRUCEJERNER j 5' BUSTTER �i—l�—�, Jerner�rAssociates,Inc. 5 ET 3 � � :, ; Marine�r Environmental Consulting Date:911/21 1221 NETTLES BLVD ` !"'` e 2537SEA1fonsoAve. Port St.Lucic,FL34952 Ph.(772)283-2950 JENSEN BEACH s k r JERNER@BELLSOUTH.NET OCT' 0�T 7 2021 UQCILIGH BOLTS 3- TO DOCK \ . PLACES \}\ _ N13T SUPPLICD « . . SEAWALL.�/ . /_, \ �� k �.\g. ■ 2a � � | � . | | } 61* �\ � | | � \�< . \MEM\ ; NON SKID STEPS ML WL EXTRUDED t • � � � SCHEDULE40 ALUMINUM TUBING - � � & ��X�»��2«���¥ � � _.,, . :■ # -19 , , ' jerner&Associates, : ' , ■ Date: 1221 \ , t / Environmental '2537SE Alfonso Avc. Port St. . . . JENSEN : 8 , ' ' ( 4 1 .0 . Pier Section Thru Pier Plan View Live Load 40 lbs./Sq Ft Dead Load 5 lbs./Sq Ft 2'- 10' SGL Bolts, Nut, r Washers 5/8"S.S.-► °' " (304) w Nut Fully e „ Threaded ` ______•=.�s.=._-._._._._.= h 2- 10' 9 Composite Decking w o; minimal plank spacing. s Fasten w#10 3"SS(304) Screws, 2 per Stringer " �A LO • �A� I� _� Al } IAI II col `Y 2"x 8"P.T. SYP, .40 co ACQ treated stringers to be butt jointed, butt joints to be staggered. ; of 2"x 8"P.T. SYP, .40 .....LW._.. ACQ treated DBL bents AI //�� 101 101 co , i e_I R I ' --------------- GRADE - Stringers 24" - -` 0.C.Max Min. 8"Dia. 2.5 CCA treated piles Center Stringer(s)foe Nailed w(2)#16 SS(304)Ring Shank Nails @ Each Bent, Outside Stringers Face Nailed w#16 SS(304)Ring Shank Nails Inside or Outside New Pilings jetted to a minimum depth of 6'and as Design Windload Information necessary to provide adequate bearing and stability Code:FBC 2017 6TH ADD/FRC 2017/ ASCE 7-10 Wind Speed: 170 MPH, 3 Second Gust Exposure`D" Importance Factor: 1.0 Internal Pressure Coeff.:0.00 Height <10 Ft. Mean B USTTER 'L4- Jerner&Associates,Inc. SH T 5 1221 NETTLES BLVD { ' '�� Marinee'r Environmental Consulting Date:.911�/21 f, 2537SEA1fonsoAve. Port Sr.Lucie,FL34952 a Pk(772)283-2950 / JENSEN BEACH .' r JERNER@BELLSOUTH.NET OCT 4-T-2Q21 ' 1 HURRICANE BOAT LIFTS CATEGORY-5 VERTICAL LIFTS ENGINEERING SPECIFICATIONS 5 B 8 s 7 PLM SPACM I1� a ® aAPMl1OT/ A B RECOMMENDED 92� 4.500 US 150' 1327 It•To 10'DIA 7 rJ DIRECT DRIVE 7,000 US 1D0' 144 Ir To 1o•DIA Piing Penetration OPTION 10,000 IS 150' 150' g'To 10'DIA To Be 10'Into The II� 4 1 1 4 I, 13.000 LB 150' 15T g•To 10'DIA Sand Bottom 0r 5' 1e,00o LB 150' Fee• 9•To—IV'DIA Into The Rock strata 3 4 20A00 LB 1e6• 15W 10•To 12•DIA Recommend 2 24,000 US 192• 1gr f0'To 1Y DIA a Plw 2 9 A WT-TO-DLrr B cwat-10-cwat 4 III T DR DIRECT DRIVE OPTION OUT—TO—OUT to" 1 2 3 4 5 6 7 8 9 G� Top 2 Cradles Bunk Q�We D.D. U.H.S. Uft Bean pr lift g� Cab,e Poet IfteringsWNdrGer Oer Cop, Ckannel I—Bean Hsee Motor SIM size ( ) eight M.P. Motor 2 Ea ON x 4'W (2 Ea) (2 Ea.) 2W x..1 x 132/O (4) 3/4 H.P. 1 H.P. 5/1W 120/20A 150•4 4,03 WIL/Lin Ft 8' 240/10A 2 Ea.5M x.te (2 Ea) (2 Ea.) x•35.21 1 H.P. 5Hx4 7,000/ 2.25 W :144/0 1 Part (5 Ea,) 1 1/2 H.P. 1t10' 4.70 WL/Lln Ft Yxe'dM' 375'DI 2440 240/t0A P r I I k BH x.17 e�liu Wood Y Sdk1 LUMOJUM SOLID (2 Ea.) (2 Ea.) 101000/ 2.5 W S/4 H.P. x.20 x 1 O Carpeted WINDER 120/20A 1 M.P. Stainless Steel PAing Mount Bracket 150' e.1B WL/LIn FL (4) 8061—Te 240 OA 240/l0A B'H x 5'W E'—� (2 Ea.) With 2-3/8'Bolts Connecting The 7H x.17 5/15' ALUM. Bracket To The Assembly. x.2g .02 W!/LYi FL SST. 1 1/2 H.P. 2-3/B'xr Stainless Steel Lag Bolts 150' (2 Ea.) 240/t0A Into The Side Of Piing 7H x.210 IO.41 x• W x10'x144• 2 Part (2 Ea.) 15,000/ 3.5 W x&0 PT 1 H.P. 1 1/2 H.P. 150• B5{WL/LH FL wood 240/10A 240/110A 10'H x e'W 3'rA0'xi6e' (2 Ea) 20,000/ i7S w x.41 .25 PT (4) (e Ea) ie841 L64 WL/un0t Crpp ted s/1eWood • 10' Y Sdid SOL D~ 12/1. 10'H x e'W YxiPrdg2' M. 6001-7d LuKMM (2 Ea.) 2{,000/ 17tf.25 w x jp0�'p ALUM. I WINDER 1 1/2 H.P. 411 for 10.25 Wt/Lin FL C pelted 1 3 Part 240/10A THE WORK SPECIFIED HEREIN HAS BEEN DESIGNED &ALL WORK SHALL BE IN ACCORDANCE WITH STRUCTURAL PROVISIONS OF THE 7th EDITION 2020 FLORIDA BUILDING CODE. NOTE: THIS LIFTING STRUCTURE HAS BEEN DESIGNED TO WITHSTAND WIND LOADS ASSOCIATED WITH WIND SPEEDS OF Vut= 180 MPH, VAm = 139 MPH (3 SEC. GUST) EXPOSURE'D' WITHOUT A BOAT ON THE LIFT PER ASCE 7-10 USING ABOVE GROUND SIGN/WALL METHOD, THE LIFTING STRUCTURE INCLUDING BOAT HAS BEEN DESIGNED TO WITHSTAND NAND SPEEDS OF Wlt=90 MPH IN EXPOSURE'C' OR 80 MPH IN EXPOSURE'D'. OWNER RESPONSIBLE TO REMOVE BOAT FROM LIFT DURING.WINDSTORM EVENT IN EXCESS Vaed AS CALA70 BELOW, PER FBC 3105.5.3 STRUCTURES DESIGNED TO BE READILY REMOVED OR REPOSITIONED DURNING PERIODS OF HIGH WIND VELOCITY SHALL BE POSTED WITH A LEGIBLE AND READILY VISIBLE DECAL OR PAINTED INSTRUCTIONS TO BE THE OWNER OR TENANT TO REMOVE OR REPOSITION THE STRUCTURE OR PART THEREOF DURNING SUCH PERIODS OF TIME AS ARE DESIGNATED BY THE U.S. WEATHER BUREAU AS BEING A HURRICANE WARNING OR ALERT. THE LIFT OWNER SHALL BE NOTIFIED OF THESE CONDITIONS BY THE PERMIT HOLDER. NO WARRANTY, EXPRESSED OR IMPLIED, IS CONTAINED HEREIN. Vasd MAY BE CALCULATED BY THE FOLLOWING FORMULA: Vasd - v0.6 a VuIL DESIGN OF BOAT WIND LOADING HAS BEEN PERFORMED WITH THE FOLLOWING RATIOS AS CONFIRMED BY OTHERS: B/s-3, s/h a 0.75. FOR A Cf of 1.6 MAXIMUM WHERE H IS THE HEIGHT TO TOP OF BOAT, B IS HORIZONTAL DIMENSION, AND S IS VERTICAL DIMENSION. CERTIFICATION OF BOAT LIFT TO EXISTING STRUCTURE AND ALL ELECTRICAL OR MECHANICAL CERTIFICATIONS ARE BY OTHERS; ENGINEER SEAL CERTIFIES ASSEMBLY OF LIFT ONLY. THIS DETAIL IS PREPARED AS A GENERAL NON-SITE SPECIFIC MASTER PLAN SHEET DETAIL TYPICAL FIELD CONDITIONS ARE ASSUMED IN THE DESIGN. WOOD PILES SHALL BE SEASONED WOOD WITH G-0.55 OR BETTER. SHOULD ANY SPECIFIC LOCATION DIFFER FROM THAT SPECIFIED HEREIN, OR STANDARD FIELD CONDITIONS, ADDITIONAL SPECIFIC ENGINEERING MAY BE REQUIRED AS DETERMINED BY THE BUILDING INSPECTOR AND PERMITTING CONTRACTOR. CARE SHALL BE TAKEN BY CONTRACTOR IN ALL APPLICATIONS OF THIS DETAIL AS THIS IS NOT A SITE SPECIFIC DRAWING, IT IS THE RESPONSIBILITY OF OTHERS TO ENSURE THE INTEGRITY OF INSTALLATION TO THE HOST STRUCTURE. ALUMINUM MATERIAL 6051 T6 ALUMINUM ALL WELDS ARE MIN. 1/4' FULL FILLET WELD USING 5556 FILLER ALLOY. ALL WELDING MUST CONFORM TO AISC STEEL CONSTRUCTION MANUAL 13TH ED AS INSPECTED AND VERIFIED BY OTHERS.THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALUMINUM MEMBERS FROM DISSIMILAR METALS TO PREVENT ELECTROLYSIS. FASTENERS ALL ANCHORS TO BE HILT! BRAND OR MFR EQUIVALENT. ALL BOLTS SHALL BE HOT DIPPED GALVANIZED, OR STAINLESS STEEL& MEET THE REQUIREMENTS OF ASTM A304 WITH HARDENED WASHERS AND HEX NUTS. WASHERS SHALL BE USED BETWEEN WOOD&BOLT HEAD &BETWEEN WOOD &NUT. WHERE GENERIC FASTENERS ARE LABELED IN DETAILS, CAPACITIES SHALL BE EQUAL TO OR GREATER THAN HILTI KWIK BOLT 11 OR RED HEAD THRU BOLTS. EMBEDMENT DEPTHS SPECIFIED HEREIN ARE DEPTHS INTO SOLID SUBSTRATE AND DO NOT INCLUDE THICKNESS OF STUCCO OR OTHER FINISHES. ALUMWEIGHTNUM) 11.7�milsR(0.3000NTACT WTH CONCRETE mm)MIN. TOTAL THICKNESSDIWOOD ACCCCORDANCE WITH CURRENT SHALL BE PROTECTED FLORIDA BUILDING Y"KOPPERS MINOUS C DE.PAINT' WELDS PER FLORIDA EBUILDING CODE. PE UHMW ULTRA HIGH MOLECULAR SPECIALTY ENGINEERING SERVICES&SOLUTIONS INC. HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. SPECIALTY ENGINEERING SERVICES&SOLUTIONS INC. SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE VERIFIED PRIOR TO CONSTRUCTION. SPECIALTY ENGINEER SERVICES&SOLUTIONS. SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. ENGINEERING SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR at al. INDEMNIFIES& SAVES HARMLESS THIS ENGINEER FOR ALL COSTS&DAMAGES INCLUDING LEGAL FEES&APPELLATE FEES RESULTING FROM MATERIAL FABMICATION, SYSTEM ERECTION &CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, &FEDERAL CODES&FORM DEVIATIONS OF THIS PLAN, EXCEPT AS EXPRESSLY PROVIDED IN HEREIN, NO CERTIFICATION OR AFFIRMATIONS ARE INTENDED. THIS SPECIFICATION SHEET GOOD ONLY AT THIS NAME AND ADDRESS VOID WITHOUT HURRICANE SEAL OVER NAME NAMEL Oscar M. Bermudez, PE. DATE: ADDRESSI Reg. Florida No. 55141 CITYi STATEL ZIP, HURRICANE BOAT LIFTS 3301 S.E. Slater Street 2237 W Engineering, Woods Edge Circle Stuart, Florlda 34997 Orlando, FL 32817 (772)-781-2556 Fax (772)-781-4854