Loading...
HomeMy WebLinkAboutAPPROVED Stamped_Plans_MirandaPagan,_Miguel_Rev_ACOVER SHEET SCOPE OF WORK GENERAL NOTES REV NAME DATE COMMENTS A AC AFCI AZIM COMP DC (E) ESS EXT INT MAG MSP (N) NTS OC PRE-FAB PSF PV RSD TL TYP V W AMPERE ALTERNATING CURRENT ARC FAULT CIRCUIT INTERRUPTER AZIMUTH COMPOSITION DIRECT CURRENT EXISTING ENERGY STORAGE SYSTEM EXTERIOR INTERIOR MAGNETIC MAIN SERVICE PANEL NEW NOT TO SCALE ON CENTER PRE-FABRICATED POUNDS PER SQUARE FOOT PHOTOVOLTAIC RAPID SHUTDOWN DEVICE TRANSFORMERLESS TYPICAL VOLTS WATTS PAGE REV: A 03/01/2022 1000 GILLS DRIVE, STE 200, ORLANDO, FL 32824 PHONE 0 FAX 0 MIGUEL MIRANDAPAGAN 5332 OAKLAND LAKE CIR, FORT PIERCE, FL, 34951 PROJECT NUMBER: 801R-332MIRA SHEET DESIGNER: JASON DITTMAN CUSTOMER RESIDENCE: TEL. (787) 360-7128 APN/TMK #: 1311-800-0029-000-3 EC13007964 (415) 580-6920 ex3 ENGINEER ADDRESS: 225 BUSH ST, SUITE 1400 SAN FRANCISCO, CA 94104 P: 949-383-0993 TABLE OF CONTENTS PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE PV-1.0 VICINITY MAP • SYSTEM SIZE: 10200W DC, 7200W AC • MODULES: (30) HANWHA Q-CELLS: Q.PEAK DUO BLK-G8+ 340 • INVERTERS: (30) ENPHASE ENERGY: IQ7-60-2-US • RACKING: SNAPNRACK RLU; RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC-00436 • ALL WORK SHALL COMPLY WITH 2020 FBC (7th Ed.) AMENDMENTS TO 2018 IRC/IBC/IEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2017. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2017. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 10.4 AMPS MODULE SHORT CIRCUIT CURRENT. • 16.25 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. #SSTAMPCS #ESTAMPCS LEGEND AND ABBREVIATIONS SCALE: NTS MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) PV LOAD CENTER SUB-PANEL CB ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS SUNRUN METER METAL PIPE VENT DEDICATED PV METER SERVICE ENTRANCE IQ COMBINER BOX HARDSCAPE PROPERTY LINEINTERIOR EQUIPMENT SHOWN AS DASHED PL SOLAR MODULES SNR MOUNT & SKIRT SNR MOUNT MP SP SM PM INV AC DC LC SE DocuSign Envelope ID: FCFE3AB2-3952-44FA-BD45-2193E4A9566F PLPLPLPL PLPLPLPL PL PL PL PLPAGE REV: A 03/01/2022 1000 GILLS DRIVE, STE 200, ORLANDO, FL 32824 PHONE 0 FAX 0 MIGUEL MIRANDAPAGAN 5332 OAKLAND LAKE CIR, FORT PIERCE, FL, 34951 PROJECT NUMBER: 801R-332MIRA SHEET DESIGNER: JASON DITTMAN CUSTOMER RESIDENCE: TEL. (787) 360-7128 APN/TMK #: 1311-800-0029-000-3 EC13007964 (415) 580-6920 ex3 ENGINEER ADDRESS: 225 BUSH ST, SUITE 1400 SAN FRANCISCO, CA 94104 P: 949-383-0993 SITE PLAN ARRAY PITCH PV AREA (SQFT) AR-01 23°251.1 AR-02 23°328.3270° TRUE AZIM MAG AZIM 189°180° 279° PV-2.0 #SSTAMPSP #ESTAMPSP SITE PLAN - SCALE = 1/16" = 1'-0" NOTE: MICRO-INVERTERS INSTALLED UNDER EACH MODULE (N) ARRAY AR-01 (N) ARRAY AR-02 SE MP AC CBSP (E) DRIVEWAY (E) RESIDENCE OAKLAND LAKE CIRHUMMINGBIRD WAYDocuSign Envelope ID: FCFE3AB2-3952-44FA-BD45-2193E4A9566F PAGE REV: A 03/01/2022 1000 GILLS DRIVE, STE 200, ORLANDO, FL 32824 PHONE 0 FAX 0 MIGUEL MIRANDAPAGAN 5332 OAKLAND LAKE CIR, FORT PIERCE, FL, 34951 PROJECT NUMBER: 801R-332MIRA SHEET DESIGNER: JASON DITTMAN CUSTOMER RESIDENCE: TEL. (787) 360-7128 APN/TMK #: 1311-800-0029-000-3 EC13007964 (415) 580-6920 ex3 ENGINEER ADDRESS: 225 BUSH ST, SUITE 1400 SAN FRANCISCO, CA 94104 P: 949-383-0993 D1 - AR-01 - SCALE: 1/8" = 1'-0" PITCH: 23° AZIM: 180° D2 - AR-02 - SCALE: 1/8" = 1'-0" PITCH: 23° AZIM: 270° PV-3.0 LAYOUT #SSTAMP ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max Span OC Spacing Detail Max Landscape OC Spacing Max Landscape Overhang Max Portrait OC Spacing Max Portrait Overhang Configuration AR-01 COMP SHINGLE - RLU 1-Story 2X4 PRE-FABRICATED TRUSSES 6' - 6"24"RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC-00436 6' - 0"2' - 4"NA NA STAGGERED AR-02 COMP SHINGLE - RLU 1-Story 2X4 PRE-FABRICATED TRUSSES 7' - 1" 24" RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC-00436 6' - 0"2' - 4"NA NA STAGGERED DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 152 MPH 3-SEC GUST. S.S.LAG SCREWS: 5/16"X4.5": 2.5" MIN EMBEDMENT STRUCTURAL NOTES: ·INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. ·IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ··ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% ··ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS7'-5"11'-6"10'-1"11'-6"5'-8"1'-1" 13'-8" 7'-5" 6' TYP 9'-3"34'-7"7'-10" 1'-3" 17'-2" 6'-10" 6' TYP ATTACHMENT ALTERNATE OPTION DECK MOUNT DETAIL: SNR-DC-00452 ATTACHMENT SPACING / OVERHANG PORTRAIT: NA / NA LANDSCAPE: 2' - 0" / 0' - 6" ATTACHMENTS PATTERN = STAGGERED OFFSET ATTACHMENTS 1’-0” ROW TO ROW #14 S.S. WOOD SCREWS MUST EMBED FULLY INTO DECK 4'-3" 2'-11"2'-11" 11'-6" 2'-11"2'-11" 5'-9" 11'-7" 2'-1" 11'-6"5'-9"3'-8" Samuel Brown, State of Florida, Professional Engineer, License No. 87830 This item has been electronically signed and sealed by Samuel Brown, PE on 3/3/2022 using a SHA authentication code. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on electronic copies. Signed on: 3/3/2022 DocuSign Envelope ID: FCFE3AB2-3952-44FA-BD45-2193E4A9566F 3/3/2022 EXISTING 200A MAIN PANELFACILITY LOADS FACILITY GROUND EXISTING 200A MAIN BREAKER (END FED) M METER #: FPL ACD4283 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID (N) 40A PV BREAKER AT OPPOSITE END OF BUSBAR (E) 225A SUB PANEL E FEED-THROUGH LUG (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A,2P 120/240VAC 3 JUNCTION BOX OR EQUIVALENT 12 20A BREAKER [A] 20A BREAKER [B] (N) 125A ENPHASE IQ AC COMBINER BOX WITH INTEGRATED 10A ENVOY BREAKER 3CX-IQ-AM1-240-3C (1) BRANCH OF (15) MICRO-INVERTERS [B] (30) HANWHA Q-CELLS: Q.PEAK DUO BLK-G8+ 340 MODULES AND MICRO-INVERTER PAIRS (30) ENPHASE ENERGY: IQ7-60-2-US -- (1) BRANCH OF (15) MICRO-INVERTERS [A] NOTE: TOTAL PV BACKFEED = 38A USED FOR INTERCONNECTION CALCULATIONS 3 CONDUIT SCHEDULE #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG PER ENPHASE Q CABLE BRANCH NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 E EXISTING MODULE CHARACTERISTICS HANWHA Q-CELLS: Q.PEAK DUO BLK-G8+ 340: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 340 W 40.7 V 34.34 V 10.4 A PAGE REV: A 03/01/2022 1000 GILLS DRIVE, STE 200, ORLANDO, FL 32824 PHONE 0 FAX 0 MIGUEL MIRANDAPAGAN 5332 OAKLAND LAKE CIR, FORT PIERCE, FL, 34951 PROJECT NUMBER: 801R-332MIRA SHEET DESIGNER: JASON DITTMAN CUSTOMER RESIDENCE: TEL. (787) 360-7128 APN/TMK #: 1311-800-0029-000-3 EC13007964 (415) 580-6920 ex3 ENGINEER ADDRESS: 225 BUSH ST, SUITE 1400 SAN FRANCISCO, CA 94104 P: 949-383-0993 PV-4.0 ELECTRICAL #ESTAMP Domingo A. Villaruel, State of Florida, Professional Engineer, License No. 85111 This item has been electronically signed and sealed by Domingo A. Villaruel, PE on 3/3/2022 using a SHA authentication code. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on electronic copies. DocuSign Envelope ID: FCFE3AB2-3952-44FA-BD45-2193E4A9566F 3/3/2022 PAGE REV: A 03/01/2022 1000 GILLS DRIVE, STE 200, ORLANDO, FL 32824 PHONE 0 FAX 0 MIGUEL MIRANDAPAGAN 5332 OAKLAND LAKE CIR, FORT PIERCE, FL, 34951 PROJECT NUMBER: 801R-332MIRA SHEET DESIGNER: JASON DITTMAN CUSTOMER RESIDENCE: TEL. (787) 360-7128 APN/TMK #: 1311-800-0029-000-3 EC13007964 (415) 580-6920 ex3 ENGINEER ADDRESS: 225 BUSH ST, SUITE 1400 SAN FRANCISCO, CA 94104 P: 949-383-0993 SIGNAGE PV-5.0 #ESTAMP ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(c), NEC 2017: 705.12(B)(2)(3)(c) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. WARNING! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2019: 705.12(B)(3), NEC 2017: 705.12(B)(3) WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): CEC 2019: 690.56(C)(3), NEC 2017: 690.56(C)(3), IFC 2012: 605.11.1, IFC 2018: 1204.5.3, CFC 2019: 1204.5.3 ELECTRICAL SHOCK HAZARD WARNING LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2019: 690.13(B), NEC 2017: 690.13(B) TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 30.00 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): CEC 2019: 690.56(C)(1)(a), NEC 2017: 690.56(C)(1)(a) 4" 3" Domingo A. Villaruel, State of Florida, Professional Engineer, License No. 85111 This item has been electronically signed and sealed by Domingo A. Villaruel, PE on 3/3/2022 using a SHA authentication code. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on electronic copies. DocuSign Envelope ID: FCFE3AB2-3952-44FA-BD45-2193E4A9566F 3/3/2022